Chemical Analysis Instruments
Filter
Showing 1351–1380 of 4351 results
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | LRGA-3200EX |
| Spectral Range | 400–700 nm |
| Spectral Resolution | 0.01% |
| Spatial Resolution | 1 µm (lateral), 2 µm (axial) |
| Minimum Wavenumber | 10 cm⁻¹ |
| Spectral Repeatability | 1% F.S. |
| Measurement Accuracy | ±1% F.S. |
| Operating Pressure | up to 4 MPa |
| Explosion Protection | Ex d II C T4 Gb |
| IP Rating | IP65 |
| Power Supply | 100–240 VAC, 50–60 Hz |
| Max Power Consumption | <200 W |
| Communication Interfaces | RS-232, RS-485, TCP/IP, USB, 4–20 mA analog output |
| Probe Quantity | 4 |
| Standard Fiber Length | 5 m (customizable) |
| Dimensions (L×W×H) | 540 × 300 × 900 mm |
| Weight | 75 kg |
| Ambient Operating Temperature (Analyzer) | 10–35 °C |
| Probe/Process Temperature | −20 to +200 °C |
| Relative Humidity | 0–95% RH (non-condensing) |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | LRGA-6000 |
| Price Range | USD 140,000–280,000 |
| Instrument Type | Grating-Based Raman Spectrometer |
| Spectral Range | 400–700 nm |
| Spectral Resolution | 0.01% |
| Minimum Wavenumber | 10 cm⁻¹ |
| Spectral Repeatability | Not Specified |
| Spatial Resolution | Not Applicable |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LRGA-6000 |
| Instrument Type | Grating-Based Raman Spectrometer |
| Spectral Range | 400–700 nm |
| Spectral Resolution | 0.01% |
| Spatial Resolution | 1 µm (lateral), 2 µm (axial) |
| Minimum Wavenumber | 10 cm⁻¹ |
| Spectral Reproducibility | ≤1% (dependent on configured measurement range) |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | LRGA-6000 |
| Spectrometer Type | Grating-Based Raman Spectrometer |
| Spectral Range | 400–700 nm |
| Spectral Resolution | 0.01% |
| Spatial Resolution | 1 µm (lateral), 2 µm (axial) |
| Minimum Wavenumber | 10 cm⁻¹ |
| Spectral Repeatability | ≤1% (dependent on configured measurement range) |
| Measurement Range | 0–10% to 0–100% (gas concentration, full-scale) |
| Linearity Error | ≤±1% F.S. |
| Response Time | ≤30 s |
| Dimensions | 1000 × 800 × 1780 mm |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LRGA-6000 |
| Instrument Type | Grating-Based Raman Spectrometer |
| Spectral Range | 400–700 nm |
| Spectral Resolution | 0.01% |
| Spatial Resolution | 1 µm (lateral), 2 µm (axial) |
| Minimum Wavenumber Shift | 10 cm⁻¹ |
| Spectral Repeatability | ≤1% (dependent on configured concentration range) |
| Measurement Range | 0–10% to 0–100% (gas volume %) |
| Linearity Error | ≤±1% FS |
| Response Time | ≤30 s |
| Dimensions | 1000 × 800 × 1780 mm |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | LRGA-6000 |
| Spectrometer Type | Grating-based Raman Spectrometer |
| Spectral Range | 400–700 nm |
| Spectral Resolution | 0.01% |
| Spatial Resolution | 1 µm (lateral), 2 µm (axial) |
| Minimum Wavenumber | 10 cm⁻¹ |
| Spectral Repeatability | ≤1% (dependent on configured measurement range) |
| Measurement Range | 0–10% to 0–100% (gas concentration, full-scale) |
| Linearity Error | ≤±1% F.S. |
| Response Time | ≤30 s |
| Dimensions | 1000 × 800 × 1780 mm |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | LRGA-6000 |
| Spectrometer Type | Grating-based Raman Spectrometer |
| Spectral Range | 400–700 nm |
| Spectral Resolution | 0.01% |
| Spatial Resolution | Lateral 1 µm, Axial 2 µm |
| Minimum Wavenumber Shift | 10 cm⁻¹ |
| Spectral Repeatability | ≤1% (dependent on configured measurement range) |
| Measurement Range | 0–10% to 0–100% (user-selectable per gas) |
| Linearity Error | ≤±1% FS |
| Response Time | ≤30 s |
| Dimensions | 1000 × 800 × 1780 mm |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Type | Online Dew Point Analyzer |
| Accuracy | ±2% F.S. |
| Repeatability | ≤1.5% F.S. |
| Measurement Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Measurement Range | 0–6000 ppmv H₂O |
| Resolution | 0.1 ppmv |
| Explosion Protection | Ex db IIC T6 Gb / Ex tb IIIC T80°C Db |
| Ingress Protection | IP66 |
| Operating Temperature | −10°C to +50°C |
| Operating Humidity | 0–98% RH (non-condensing) |
| Sample Pressure | Inlet: 140–310 kPa |
| Measurement Cell | 800–1200 mbara |
| Power Supply | 24 VDC ±20% or 100–240 VAC ±10%, 50/60 Hz, 10 W |
| Communication Interfaces | RS-485, 4–20 mA, Modbus RTU/TCP, Ethernet |
| Dimensions (L×W×H) | 400 × 400 × 250 mm |
| Weight | 36 kg |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Model | AxiChrom 50/300 |
| Column Internal Diameter | 50 mm |
| Column Height (Max. Packing Height) | 300 mm |
| Construction Material | USP Class VI–compliant polymers, animal-free origin, FDA 21 CFR 177 compliant |
| Regulatory Support | IQ/OQ documentation packages available |
| Sterilization | Steam-in-place (SIP) compatible |
| Column Operation | Low-pressure preparative chromatography (≤ 5 bar typical) |
| Packing Method | Automated slurry packing via ÄKTA systems and UNICORN software |
| Scale-up Platform | Process development to GMP manufacturing (50–200 mm i.d. range) |
| Origin | Sweden |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AxiChrom |
| Pricing | Available Upon Request |
| Brand | Cytiva |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | BioProcess IC 1.5-inch |
| Pricing | Available Upon Request |
| Brand | Cytiva |
|---|---|
| Origin | Sweden |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FineLINE Pilot 35 |
| Price | Upon Request |
| Brand | GKINST |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | D-POWER |
| Price Range | USD 42,000 – 210,000 |
| Instrument Type | Powder X-ray Diffractometer |
| Configuration | Floor-standing |
| Power Rating | 3 kW |
| Angular Accuracy | 0.0001° |
| Brand | D&T |
|---|---|
| Origin | Tianjin, China |
| Model | EX-FH104A |
| Heating Source | Halogen Lamp |
| Weighing Range | 120 g |
| Readability | 0.1 mg |
| Repeatability (2 g sample) | 0.05% SD, ±0.1% |
| Repeatability (10 g sample) | 0.01% SD, ±0.05% |
| Moisture Readability | 0.001% MC |
| Calibration | Fully Automatic Internal Calibration |
| Drying Temperature Range | Single-Glass Mode: 40–160 °C |
| Dual-Glass Mode | 40–200 °C |
| Increment | 1 °C |
| Pan Diameter | Φ90 mm |
| Dimensions (W × D × H) | 200 × 385 × 120 mm |
| Moisture Range | 0.01–100% MC |
| Method Storage | 300 methods |
| Result Storage | 3000 records |
| Heating Programs | Standard, Stepwise, Rapid |
| Drying Termination Modes | Timed, Auto (5 preset weight-loss thresholds + user-defined threshold) |
| Warm-up Time | 20–30 min |
| Display Modes | %MC, %DC, g |
| Output Interfaces | RS232/RS485, LAN, USB1 (data export/firmware update), USB2 (dedicated printer) |
| Touchscreen | 7-inch capacitive |
| Sensor Type | Integrated electromagnetic force compensation sensor |
| Design | Separated weighing and display units |
| Brand | NCA |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Norlite |
| Instrument Type | Dynamic Axial Compression (DAC) System |
| Material Certification | USP Class VI (USP 87 & USP 88), FDA 21 CFR 177.1010, TSE-Free, Animal-Origin-Free |
| Base Material | Medical-Grade Polymethyl Methacrylate (PMMA) |
| Brand | GKINST |
|---|---|
| Model | DAC-HTP700 |
| Origin | Anhui, China |
| Press Type | BX90 (optional) |
| Press Material | Inconel 718 superalloy |
| Temperature Range | RT to 700 °C |
| Temperature Control Accuracy | ±1 °C |
| DAC Components | Tungsten Carbide gasket, Type-Ia diamond anvils |
| Temperature Regulation | PID dynamic feedback control |
| Thermocouple | K-type |
| Vacuum Chamber Leak Rate | <1×10⁻⁸ Pa·L/s |
| Brand | DAJ |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (PRC) |
| Model | WGJ-III |
| Pricing | Upon Request |
| Brand | China Innovation Instrument (CII) |
|---|---|
| Model | DBDI-200 |
| Ionization Principle | Dielectric Barrier Discharge (DBD) Coupled with SPME |
| Compatibility | Universal MS Interfaces (ESI, APCI, and Atmospheric Pressure Inlet Ports) |
| Origin | Zhejiang, China |
| Regulatory Compliance | Designed for GLP/GMP-aligned workflows |
| Pricing | Available upon technical consultation |
| Brand | DC-Energies |
|---|---|
| Model | DC 780 |
| Origin | Hubei, China |
| Manufacturer | Wuhan DC-Energies New Energy Co., Ltd. |
| Type | Benchtop Electrolyzer Test System |
| H₂/O₂ Flow Measurement Accuracy | ±1% FS |
| Operating Pressure Range | 1–10 bar (adjustable via high-precision back-pressure regulator) |
| Temperature Control Stability | ±0.5 °C |
| Data Acquisition Rate | 5 Hz |
| Flow Control | Mass Flow Controllers (MFCs) for H₂ and O₂ |
| Software Compliance | Audit Trail Ready, User Access Levels, Test Parameter Locking (GLP/GMP-aligned architecture) |
| Brand | dc-energies |
|---|---|
| Model | DC TP-100 |
| Max. Hydraulic Force | 10 t (≈39.2 MPa on 5×5 cm² area) |
| Temperature Range | 50–350 °C (dual-zone heating) |
| Pressure Control | Digital Display, Four-Column Uniform Load Architecture |
| Compliance | Designed for PEM Fuel Cell MEA Fabrication per ASTM D7263, ISO 14687, and DOE Hydrogen Program Best Practices |
| Brand | DE |
|---|---|
| Origin | United Kingdom |
| Model | DE Spectrum HPCCC |
| Configuration | Analytical to Semi-Preparative |
| Column Volume | 20–125 mL |
| Sample Load per Run | 50–1250 mg |
| Mobile Phase Flow Rate | 1–10 mL/min |
| Rotational Speed | 1600 rpm |
| Phase System | Liquid–Liquid Biphasic Solvent System |
| Solvent Consumption | ~10% w/w relative to crude sample mass |
| Brand | DeChem-Tech |
|---|---|
| Origin | Germany |
| Model | CleverChem 380 |
| Product Type | Discrete Analyzer |
| Wavelength Range | 400–900 nm |
| Sample Volume per Vial | 5 mL |
| Reagent Positions | 49 |
| Cuvette Path Length | 10 mm |
| Light Source | Tungsten-Halogen Lamp |
| Brand | DeChem-Tech |
|---|---|
| Origin | Germany |
| Instrument Type | Discrete Analyzer (Flow-Based Spectrophotometric Analyzer) |
| Model | CleverChem F.U.V. |
| Wavelength Range | 200–850 nm |
| Sample Volume per Test | 10 mL |
| Reagent Positions | N/A (Reagent-free operation for core wine parameters) |
| Flow Cell Pathlength | 0.20 mm |
| Light Source | Deuterium + Tungsten-Halogen UV/Vis Lamp (2000 h lifetime) |
| FTIR Resolution | < 0.4 cm⁻¹ |
| UV-Vis Spectral Resolution | 0.25 nm |
| Detector | 2048-pixel CCD array (200 × 14 µm/pixel) |
| Temperature Control Range | 5–35 °C |
| Dimensions (Analyzer Unit) | 35 × 28 × 26 cm (W×D×H) |
| Weight | 10 kg |
| Compliance | Designed for GLP-compliant wine laboratories |
| Brand | DECTRIS |
|---|---|
| Origin | Switzerland |
| Model | EIGER2 R |
| Detector Module Count | 1 / 2 / 4 |
| Active Area (W×H) | 77.2×38.6 mm² / 77.1×79.7 mm² / 155.1×162.2 mm² |
| Pixel Size | 75×75 µm² |
| Point Spread Function | 1 pixel |
| Energy Thresholds | 2 |
| Threshold Range | 3.5–30 keV |
| Maximum Count Rate | 6.9×10⁸ cps/mm² |
| Counter Depth | 2×16 bit per threshold |
| Frame Rate | 50 / 100 / 20 Hz |
| Readout Mode | Simultaneous read/write, zero dead time |
| Image Bit Depth | 32 bit |
| Vacuum Compatibility | Optional |
| Cooling | Air / Water / Water |
| Dimensions (W×H×D) | 100×140×93 mm³ / 114×133×240 mm³ / 235×235×372 mm³ |
| Weight | 1.8 / 4.7 / 15 kg |
| Brand | DELEITE |
|---|---|
| Origin | Beijing, China |
| Instrument Type | Single-beam Visible Spectrophotometer |
| Model Series | 721 / 722 / 722N / 722S |
| Wavelength Range | 320–1100 nm |
| Spectral Bandwidth | 2 nm (722S), 4–6 nm (721/722/722N) |
| Wavelength Accuracy | ±2 nm (721/722/722N), ±1 nm (722S/723 series) |
| Wavelength Repeatability | ≤0.2–1 nm |
| Stray Light | ≤0.05%T @ 360 nm |
| Photometric Accuracy | ±0.3–0.5%T |
| Photometric Repeatability | ±0.2%T |
| Baseline Linearity | ≤0.2%T |
| Drift | ≤0.001–0.004 A/h @ 500 nm |
| Noise | ≤0.1–0.3%T |
| Optical System | Czerny-Turner monochromator with 1200 lines/mm grating |
| Detector | Imported silicon photodiode |
| Light Source | Imported tungsten halogen lamp |
| Display | 128×64 dot-matrix LCD |
| Data Output | RS-232 (optional), parallel port (optional), USB (via YOKE 3.0 software interface) |
| Sample Compartment | Accommodates cuvettes from 5 mm to 100 mm pathlength |
| Compliance | Designed for routine QC/QA in accordance with ISO 6425, ASTM E275, and USP <857> spectrophotometric validation principles |
| Brand | DELEITE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Model | AAS-9000G |
| Quotation | Upon Request |
| Optical Design | Single-beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 185–190 nm |
| Wavelength Automation | Motorized Auto-Scanning & Peak Search |
| Spectral Bandwidth | 0.1, 0.2, 0.4, 0.7, 1.4, 2.0 nm (6-step motorized selection) |
| Brand | DELEITE |
|---|---|
| Origin | Shanghai, China |
| Model | AKN-3240 |
| Automation Level | Fully Automated |
| Nitrogen Determination Range | 0.01–240 mg N per sample |
| Distillation Time | 0–9 min/sample |
| Titration Precision | RSD < 0.0012 µL/step |
| Minimum Titration Volume | 1–20 µL/step (auto-adjusted based on standard acid concentration) |
| Recovery Rate | >99.5% |
| Power Adjustment Range | 0–1500 W |
| Linearity | RSD <1.0% across 1× to 4× sample mass (same matrix) |
| Repeatability (RSD) | <0.5% |
| Digestion Tube Compatibility | Ø42 × 300 mm (supports both 300 mL and 650 mL tubes) |
| Data Storage Capacity | ≥200,000 sample records (≥7 years at typical lab throughput) |
| Compliance | Supports audit-trail-enabled operation per GLP/GMP requirements |
| Brand | DELEITE |
|---|---|
| Origin | Shanghai, China |
| Model | APT300 |
| Instrument Type | General-Purpose Potentiometric Titrator |
| Measurement Range | 0 to ±1999 mV, 0 to 14.00 pH |
| Accuracy | 0.1% F.S. (mV), ±0.01 pH |
| Control Precision | ±0.03 pH, ±3 mV |
| Input Impedance | >10¹² Ω |
| Operating Temperature | 5–40 °C |
| Relative Humidity | <85% RH |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Power Consumption | 20 W |
| Weight | 6 kg |
| Brand | DELEITE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | DarkS-300B |
| Optical Design | Single-beam |
| Detector Type | Photocell |
| Wavelengths | 254 nm and 365 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | ≤±1 nm |
| Stray Light | ≤0.1% |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Dimensions (L×W×H) | 300 × 300 × 270 mm |
| Illuminated Area | 250 × 250 mm |
| Filter Size | 150 × 50 mm |
| Weight | 3 kg |
| Brand | DELEITE |
|---|---|
| Origin | Shanghai, China |
| Model | DLT-6500 |
| Optical System | Dual-beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Spectral Bandwidth | 2 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ±0.1 nm |
| Stray Light | ≤0.05%T |
| Photometric Range | 0–200%T, –0.3–3 A |
| Photometric Accuracy | ±0.5%T, ±0.004 A (0–0.5 A), ±0.008 A (0.5–1 A) |
| Photometric Repeatability | ±0.5%T, ±0.004 A (0–0.5 A), ±0.008 A (0.5–1 A) |
| Baseline Stability | ±0.002 A (500 nm, 3 min) |
| Display | 7-inch TFT-LCD touchscreen (1024 × 768) |
| Interfaces | USB 2.0, Bluetooth 4.2, Wi-Fi 802.11 b/g/n |
| Software Compatibility | PC-based spectral analysis suite (optional), cloud-enabled IoT firmware (standard) |