| Brand | Metrohm |
|---|---|
| Origin | Netherlands |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Multi Autolab/M204 |
| Instrument Type | Electrochemical Workstation |
| Number of Channels | Up to 12 independent channels |
| Current Range | 10 mA to 10 nA (7 decades) |
| Current Accuracy | ±0.2% of reading |
| Potential Accuracy | ±0.2% of full scale |
| Potentiostatic Range | ±10 V |
| EIS Frequency Range | 10 µHz to 1 MHz |
| Origin | Netherlands |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | NOVA |
| Pricing | Available Upon Request |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer | Metrohm AG |
| Product Type | Imported Instrument |
| Model | OMNIS |
| Instrument Category | General-Purpose Potentiometric Titrator |
| Application Scope | Universal |
| Measurement Range | –2400 to +2400 mV |
| Meter Accuracy | ±0.2% of full scale |
| Meter Resolution | 0.1 mV |
| Titration Accuracy | ±0.2 mV |
| Titration Resolution | 1 part in 100,000 |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer | Metrohm AG |
| Import Category | Imported Instrument |
| Model | OMNIS KF Oven |
| Instrument Type | Automated Sample Processor for Electrochemical Moisture Analysis |
| Maximum Heating Temperature | 300 °C |
| Sample Capacity | Up to 100 × 6 mL vials (unattended) |
| Compatible Vial Standards | ISO 8362 (2R–30R), plus standard 6 mL crimp-top and 8 mL screw-cap vials |
| Heating Modules | Configurable with 1 or 2 independent oven modules |
| Carrier Gas Options | Dry ambient air or nitrogen, with integrated large-capacity molecular sieve dryer |
| Needle Depth Adjustment | Motorized, programmable syringe needle extension for optimal vial penetration |
| Optional Integration | OMNIS Liquid Handling Module for automatic reagent replenishment (KF reagent and methanol) |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer | Metrohm AG |
| Type | Volumetric Karl Fischer Titrator |
| Titration Mode | Fully Automated |
| Measurement Range | –2400 to +2400 mV |
| Accuracy | ±3 µg (for 10–1000 µg water) |
| Minimum Dispense Volume | 10 µg |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | OMNIS NIR |
| Instrument Type | Benchtop Laboratory Spectrometer |
| Principle | Fixed-grating array-detector non-scanning design |
| Wavelength Range | 1000–2250 nm |
| Scan Speed | 300 spectra/s |
| Data Sampling Interval | 0.5 nm |
| Sample Modes | Diffuse Reflectance / Transmission / Transflection |
| Chemometrics Software | OMNIS Platform |
| Brand | Metrohm |
|---|---|
| Origin | Netherlands |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | PGSTAT 302F |
| Instrument Type | Electrochemical Workstation |
| Channel Configuration | Multi-Channel Workstation |
| Current Range | 10 nA – 1 A |
| Current Accuracy | ±0.2% of reading or range |
| Potential Accuracy | ±0.2% of reading |
| Potentiostatic Range | ±10 V |
| Electrochemical Impedance Spectroscopy (EIS) Frequency Range | 10 µHz – 1 MHz |
| Floating Mode Capability | Yes (dual-mode operation: grounded and floating) |
| Input Bias Current (25°C) | <1 pA |
| Potential Resolution | 300 nV |
| Current Resolution (at 10 nA range) | 30 fA |
| Compatible FRA Module | FRA32M (±2 A max output, ±30 V max output, 9 current ranges) |
| Brand | Metrohm |
|---|---|
| Origin | Netherlands |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PGSTAT128N |
| Channel Configuration | Single-Channel Workstation |
| Current Range | 10 nA – 100 mA (7 decades) |
| Current Accuracy | ±0.2% of reading and range |
| Potential Range | ±10 V |
| Potential Accuracy | ±2 mV or ±0.2% of set value |
| Potentiostat Bandwidth | >500 kHz |
| Rise/Fall Time (1 V step, 10–90%) | <500 ns |
| Input Bias Current (25 °C) | <1 pA |
| Input Impedance | >100 GΩ |
| Coulometric Bandwidth | >4 MHz |
| EIS Frequency Range | 10 µHz – 1 MHz |
| Sampling Rate | Up to 50 kHz (standard), up to 750 kHz with ADC750 module |
| Potential Resolution | 150 µV (applied), 30/300 µV (measured) |
| Current Resolution | 0.0003% of range (e.g., 30 fA at 10 nA range) |
| Brand | Metrohm |
|---|---|
| Origin | Sweden |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | PRO Online NIR |
| Instrument Type | Online Process Analyzer |
| Application Field | Petrochemical Industry |
| Operating Principle | Fixed Grating with Diode Array Detector (Non-Scanning) |
| Wavelength Range | 1100–1650 nm (Reflectance), 850–1050 nm (Transmittance) |
| Scan Speed | 0.5 s per spectrum |
| Spectral Sampling Interval | 0.5 nm |
| Sample Interface Modes | Diffuse Reflectance (Solids), Transflectance (Liquids), Transmission (Liquids) |
| Chemometrics Software | Vision with ISIcal™ |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | SECM |
| Instrument Type | Multichannel Electrochemical Workstation |
| Current Range | 10 pA – 100 pA |
| Current Resolution | 0.3 fA |
| Potential Accuracy | ±0.3 µV |
| Potentiostatic Range | ±30 V |
| EIS Frequency Range | 10 µHz – 1 MHz |
| Positioning System | XYZ Stepper Motor Control |
| Scan Volume (Standard) | 25 × 25 × 25 mm |
| Max Linear Scan Speed | 10 mm/s |
| Spatial Resolution | 20 nm |
| Operating Modes | Feedback Mode, Generation-Collection (GC) Mode, Direct Mode, AC-SECM (Local Impedance), 4D Mode, Shear-Force Mode |
| Scan Types | 2D, 3D, Equidistant, Fast Equidistant, User-Defined Electrochemical Protocol Scans |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | SPELEC RAMAN |
| Instrument Type | Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Range | ±40 mA |
| Current Accuracy | ≤0.5% of full scale |
| Potential Accuracy | ±0.2% of full scale |
| Potentiostatic Range | ±4 V |
| AC Impedance Frequency Range | Not specified |
| Optical Detection Range | 350–1050 nm (UV/VIS spectrometer integrated) |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer | Metrohm AG |
| Import Status | Imported |
| Model | SPELEC |
| Instrument Type | Electrochemical Workstation |
| Channel Configuration | Single-Channel |
| Current Range | ±40 mA |
| Current Accuracy | ≤0.5% |
| Potential Accuracy | ±0.2% |
| Potentiostatic Range | ±4 V |
| EIS Frequency Range | 10 mHz – 1 MHz |
| Optical Detection Ranges | 200–900 nm or 350–1050 nm (user-selectable) |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | SPELECNIR |
| Instrument Type | Multichannel Electrochemical Workstation |
| Current Range | ±1 nA to ±10 mA |
| Current Accuracy | ±0.5 % of reading |
| Potential Accuracy | ±0.2 % of full scale |
| Potentiostatic Range | ±4 V |
| Impedance Frequency Range | Not applicable (dedicated EC–NIR coupling system, not EIS-capable) |
| Brand | Metrohm |
|---|---|
| Origin | USA |
| Manufacturer | Metrohm AG |
| Product Type | Portable/Handheld Raman Spectrometer |
| Model | TacticID-1064 |
| Spectral Range | 176–2900 cm⁻¹ |
| Spectral Resolution | 9 cm⁻¹ |
| Spatial Resolution | 1 µm (lateral), 1 µm (axial) |
| Minimum Wavenumber | 176 cm⁻¹ |
| Spectral Repeatability | ±1 cm⁻¹ |
| Brand | Metrohm |
|---|---|
| Origin | USA |
| Manufacturer | Metrohm AG |
| Product Type | Portable/Handheld Raman Spectrometer |
| Model | TacticID-N |
| Spectral Range | 176 – 2900 cm⁻¹ |
| Spectral Resolution | ~9 cm⁻¹ at 912 nm |
| Compliance | Designed for forensic field use in accordance with ISO/IEC 17025–aligned operational protocols |
| Software | Embedded spectral library with remote update capability |
| Detection Technology | Conventional Raman + optional SERS (via TacPac™ accessory) |
| Brand | Metrohm |
|---|---|
| Origin | Netherlands |
| Manufacturer | Metrohm Autolab |
| Type | Electrochemical Workstation |
| Model | VIONIC |
| Current Range | ±6 A |
| Current Accuracy | ±0.2% |
| Potential Accuracy | ±0.2% |
| Potentiostatic Range | ±10 V |
| Galvanostatic Range | ±6 A |
| EIS Frequency Range | 10 µHz – 10 MHz |
| Compliance Voltage | ±50 V |
| Minimum Sampling Interval | 1 µs |
| Floating Mode | Optional |
| Dual Reference Electrode Support (S2) | Yes |
| Electrochemical Cell Isolation | Yes |
| Oscillation Protection | Yes |
| Independent Cell Switch | Yes |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Instrument Type | Coulometric Karl Fischer Titrator |
| Model | C20S / C30S |
| Titration Mode | Fully Automatic |
| Measurement Resolution | 0.1 mV |
| Water Content Range | 10 µg – 200 mg H₂O |
| Accuracy | ±0.3% (for samples containing >1 mg H₂O) |
| Minimum Charge Delivery | 0.1 mC |
| Titration Control Precision | 0.1 mC |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Titration Mode | Fully Automated |
| Measurement Resolution | 0.1 mV |
| Water Content Range | 10 µg – 200 mg H₂O |
| Accuracy | ±0.3% (for samples containing >1 mg H₂O) |
| Minimum Dosing Increment | 0.1 mC |
| Titration Control Precision | 0.1 mC |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | C20S / C30S |
| Compliance | GLP/GMP-ready, FDA 21 CFR Part 11–capable (with LabX Server) |
| Electrode Options | Membrane-free or membrane-separated coulometric electrolysis cell |
| Interface | 7-inch full-color capacitive touchscreen with One Click™ UI |
| Language Support | English, Chinese, German, French, Spanish, Italian, Russian, Polish, Korean, Portuguese |
| Connectivity | USB 2.0 (printer, flash drive), Ethernet (TCP/IP), RS232 (optional) |
| User Management | 4-tier permission hierarchy with password protection and audit trail logging |
| Software Integration | LabX Express (standalone), LabX Server (networked, multi-instrument, compliant archiving) |
| Automation Ready | Compatible with InMotion KF Heating Oven Autosampler (C30S only) |
| Solvent Handling | Integrated Solvent Manager with automated reagent dispensing and waste evacuation |
| Certifications | CE, UL, RoHS |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | China |
| Manufacturer Type | Authorized Distributor |
| Model | HC103 |
| Heating Source | Halogen Lamp |
| Display | Capacitive Touchscreen |
| Construction | Stainless Steel Housing |
| Dimensions (W×D×H) | 210 × 340 × 180 mm |
| Weight | ~6.5 kg |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | DispenSix |
| Measurement Range | −2000 mV to +2000 mV |
| Potentiometric Resolution | 0.1 mV |
| Potentiometric Accuracy | ±0.1 mV |
| Dispensing Precision | ±0.42 µL |
| Dispensing Resolution | 1/120,000 |
| Volume Range | 10 µL – 500 mL |
| Compliance | ISO 8655-3 |
| Brand | METTLER TOLEDO |
|---|---|
| Model | DL22 |
| Application Scope | Chloride, Ascorbic Acid, Iodine Value, Peroxide Value, Total Hardness, Free SO₂, Glucose, Kjeldahl Nitrogen, Reducing Sugars, Ca²⁺/Mg²⁺/K⁺, Organic Acids |
| Titration Modes | Endpoint & Equivalence Point Detection |
| Dispensing Modes | Dynamic & Fixed-Volume |
| Burette Resolution | 1/10,000 |
| Potential Resolution | 0.1 mV |
| Data Storage | 100 Sample Results |
| Stirring Options | Magnetic & Propeller |
| Burette Volumes | 1 mL, 5 mL, 10 mL, 20 mL |
| Compliance | GLP/GMP/FDA 21 CFR Part 11–Ready Reporting |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Product Type | OEM-Approved Thermal Analysis Accessories |
| Compatibility | DMA/SDTA 1+, TMA/SDTA 2+ Platforms |
| Regulatory Compliance | CE, ISO 9001–Certified Manufacturing |
| Software Integration | STARe Excellence Suite v16.0+ |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | Easy Na |
| Measurement Principle | Potentiometric Standard Addition Method (Sodium-Selective Electrode, Non-Calibration Required) |
| Compliance | Designed for GB 28050–2011 nutritional labeling requirements |
| Software Integration | EasyDirect™ Data Acquisition Software |
| Reagent System | NaCl-based ISA (no AgNO₃ required) |
| Target Matrix | Food & Beverage samples (liquid, homogenized, or acid-digested) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Easy UV |
| Price | Upon Request |
| Wavelength Range | 190–1000 nm |
| Photometric Accuracy (K₂Cr₂O₇) | ±0.005 A |
| Wavelength Accuracy | ±1.5 nm |
| Stray Light (KCl, 198 nm) | ≤2.5% |
| Light Source | Xenon Flash Lamp |
| Optical Path Lengths | 10 mm, 16 mm, 20 mm, 30 mm, 40 mm, 50 mm (1 inch equivalent) |
| Display | 4.3-inch capacitive touchscreen |
| Dimensions (H×W×D) | 176 × 201 × 362 mm |
| Weight | 4.25 kg |
| Max. Stored Methods | 80 |
| User-Defined Quick Keys | 10 |
| Supported Languages | English, Spanish, French, German, Italian, Portuguese, Polish, Japanese, Korean, Chinese, Thai, Indonesian |
| Colorimetric Standards | CIELAB, APHA, Gardner (30 pre-programmed color scales) |
| Compliance | Designed to support pharmacopeial workflows (USP <85>, EP 2.2.25, JP 2.04) |
| Connectivity | USB port for printer (USB-P25), barcode scanner (SQKitReader™), and peripheral storage |
| Sample Handling | Fixed cuvette holder (no autosampler or cuvette changer) |
| Application Scope | Quantitative analysis, spectral scanning, water quality testing (Spectroquant® integration), color measurement |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | Easy VIS |
| Wavelength Range | 330–1000 nm |
| Photometric Accuracy (K₂Cr₂O₇) | ±0.005 A |
| Wavelength Accuracy | ±1.5 nm |
| Light Source | Tungsten Halogen Lamp |
| Optical Path Options | 10, 16, 20, 30, 40, 50 mm (1 inch) |
| Display | 4.3-inch capacitive touchscreen |
| Dimensions (H × W × D) | 176 × 201 × 362 mm |
| Weight | 4.25 kg |
| User-Defined Methods | Up to 80 |
| Quick Access Keys per User | 10 |
| Supported Languages | English, Spanish, French, German, Italian, Portuguese, Polish, Japanese, Korean, Chinese, Thai, Indonesian |
| Barcode Reader Compatibility | SQKitReader™ handheld scanner (optional) |
| Printer Interface | USB-P25 |
| USB Host Port | Yes |
| Cuvette Changer | Not integrated |
| Pharmacopeia Compliance | Not specified |
| Colorimetric Standards | 25 pre-programmed methods (CIELAB, APHA, Gardner, etc.) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic (China-manufactured) |
| Models | ET18 / ET28 / ET38 / ET58 / Easy Na |
| Price Range | USD 700 – 7,000 (FOB) |
| Instrument Type | General-purpose Potentiometric Titrator |
| Application Scope | Universal |
| Measurement Ranges | pH: 1–14 |
| mV | 0–2000 mV |
| Temperature | 0–100 °C |
| Meter Accuracy | ±0.2% of full scale |
| Resolution | pH: 0.01 pH |
| mV | 0.1 mV |
| Temperature | 0.1 °C |
| Titration Stability | (±0.3 mV ±1 digit) over 3 hours |
| Origin | Switzerland |
|---|---|
| Model | EM120 |
| Maximum Capacity | 124 g |
| Readability | 0.001 g / 0.01% |
| Pan Diameter | 90 mm |
| Repeatability | ±0.2% (1 g sample), ±0.02% (10 g sample) |
| Heating Source | Halogen lamp |
| Temperature Range | 30–230 °C |
| Temperature Increment | 1 °C |
| Heating Mode | Boost function (140% target temperature for first 3 min) |
| Termination Criteria | Automatic, semi-automatic (user-defined mass change per second), or time-based (0.1–240 min) |
| Data Output Interval | 0.1–10.0 min |
| Stored Methods | 5 user-defined profiles |
| Security | Password-protected settings, physical lock slot |
| Interface | RS232 |
| Firmware Update | Network-enabled via PC connection |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | ET Series (ET08/ET12/ET15/ET18/ET28/ET38/ET58) |
| Type | Benchtop Automatic Potentiometric Titrator |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Software Interface | EasyDirect™ (PC-based), iTitrat™ intelligent calculation engine |
| Titration Drive Resolution | 12,000 steps per full stroke |
| Display | Capacitive touchscreen interface |
| Liquid Handling | Motorized burette with programmable dosing modes (fixed-volume dispensing, manual titration assist, auto-titration) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | ET08 |
| Instrument Type | Coulometric & Volumetric Karl Fischer Titrator |
| Moisture Measurement Range | 100 ppm – 100% (w/w) |
| Voltage Input Range | 0–2000 mV |
| Polarization Current Resolution | ±0.1 µA |
| Minimum Detectable Water Content | 100 ppm |
| Dimensions (W×D×H) | 170 × 220 × 350 mm |
| Weight | 1.9 kg (instrument only), +0.8 kg (magnetic stirrer base) |
| Display | 4.3-inch RGB touchscreen (480 × 272 pixels) |
| Power Supply | 24 VDC / 1.25 A |
| Input | 100–240 VAC ±10%, 50/60 Hz |
| Operating Environment | 5–40 °C, ≤80% RH at 31 °C |
| Communication Interfaces | USB-A (high/low speed), USB-B (high/low speed) |