Chemical Analysis Instruments
Filter
Showing 2611–2640 of 10669 results
| Brand | East & West Analysis |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Sequential Scanning ICP-OES |
| Detection Limit | Sub-ppb level |
| Precision (RSD) | ≤1.0% |
| Long-term Stability (RSD) | ≤2.0% |
| Wavelength Range | 180–500 nm |
| Optical Resolution | ≤0.012 nm |
| Brand | East & West Analysis |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | ICP-7760HP |
| Instrument Type | Full-Spectrum Direct-Reading ICP-OES |
| Price Range | USD 70,000–100,000 (FOB Beijing) |
| Brand | East & West Analysis |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | ICP-7762 |
| Price | Upon Request |
| Wavelength Range | 165–800 nm |
| Observation Mode | Vertical Torch Dual-View Configuration |
| Detector | CCD with Auto-Adaptive Purge |
| Purge Gas System | Independent Dual-Path Purging (CCD + Optics Chamber) |
| Purge Gas Options | Argon or Nitrogen (Selectable) |
| Brand | East & West Analytical |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Regional Classification | Domestic (China) |
| Model | GC-4100 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | (Ambient + 5) °C to 400 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Oven Cool-Down Rate | 400 °C → 50 °C (typical) |
| Carrier Gas Flow Control Range | 1–500 mL/min (EPC) |
| Carrier Gas Pressure Control Range | 0–145 psi (EPC) |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–145 psi (EPC) |
| Injector Total Flow Setting Range | 1–500 mL/min (EPC) |
| Origin | Italy |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | EasyChem Plus |
| Price | Upon Request |
| Brand | Easysensor |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DF-H-05 |
| Price | USD 165 (FOB) |
| Target Analytes | Fe, Cd, Co, Cu, Mn, Zn, Pb, Ni, P, As, Cr, Mo, Sb, Se, V, W |
| Binding Layer | ZrO₂–Chelex composite gel, thickness 0.40 mm, dimensions 150 × 20 mm |
| Filter Membrane | PVDF, 0.10 mm thick, 150 × 20 mm |
| Diffusive Gel | Agarose-based, nominal thickness 0.80 mm |
| Sampling Area | 3000 mm² (150 × 20 mm) |
| Packaging | Individually sealed in sterile, light-blocking aluminum foil pouches under moist conditions |
| Shelf Life | 12 months at room temperature, protected from light and desiccation |
| Brand | Easysensor |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ZG-SPAMS 1000 (01) |
| Price | Upon Request |
| Particle Size Range | 0.15–9 μm (selectable modes: 0.15–5 μm or 0.3–9 μm) |
| Sample Flow Rate | 0.1–0.5 L/min |
| Particle Throughput | Up to 20,000 particles/sec |
| Laser Wavelengths | 405 nm (dual-step aerodynamic sizing), 266 nm (laser ionization), 355 nm (LIF excitation) |
| Mass Analyzer | Bipolar Time-of-Flight (TOF-MS) |
| Mass Resolution | ≥1000 (at Pb⁺, m/z 208) |
| Mass Range | 1–900 amu |
| Detection Limit | 0.001 particles/cm³ |
| Fluorescence Module | Integrated Laser-Induced Fluorescence (LIF) for biological particle pre-screening |
| Dimensions | 1160 × 780 × 560 mm |
| Weight | 140 kg |
| Brand | Easysensor |
|---|---|
| Model | ZG-SPAMS 1000 (02) |
| Origin | Jiangsu, China |
| Particle Size Range | 0.15–9 µm (airborne aerodynamic diameter) |
| Detection Rate | up to 20,000 particles/sec |
| Mass Range | 1–900 amu |
| Mass Resolution | 1000 @ Pb⁺ |
| Laser Wavelengths | 405 nm (size), 266 nm (ionization), optional 355 nm (LIF) |
| Flow Rate Options | 0.1–0.5 L/min |
| Dimensions | 1160 × 780 × 560 mm |
| Weight | 140 kg |
| Minimum Detectable Concentration | 0.001 particles/cm³ |
| Brand | Easysensor |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ZG-SPAMS 1000 |
| Pricing | Upon Request |
| Brand | Easysensor |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ZG-SPAMS 1000(15) |
| Pricing | Upon Request |
| Particle Size Range | 0.15–9 μm (selectable modes: 0.15–5 μm or 0.3–9 μm) |
| Sample Flow Rate | 0.1–0.5 L/min |
| Particle Throughput | Up to 20,000 particles/sec |
| Sizing Method | Dual-step 405 nm aerodynamic laser scattering |
| Fluorescence Detection | Integrated 266/355 nm LIF module for bio-aerosol pre-screening |
| Ionization | 266 nm Nd:YAG pulsed laser |
| Mass Analyzer | Bipolar reflectron time-of-flight (TOF-MS) |
| Mass Resolution | ≥1000 (FWHM at Pb⁺) |
| Mass Range | 1–900 Da |
| Detection Limit | 0.001 particles/cm³ |
| Data Acquisition Rate | 60 single-particle mass spectra/sec |
| Dimensions | 1160 × 780 × 560 mm |
| Weight | 140 kg |
| Brand | Unimicro Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | Easysep-1050 |
| Instrument Type | Binary Pump |
| Flow Mode | Dual-Piston Reciprocating in Series |
| Flow Rate Range | 0.001–9.999 mL/min |
| Flow Resolution | 0.001 mL/min |
| Max Operating Pressure | 42 MPa (pressure upper/lower limit programmable with auto-alarm) |
| Flow Accuracy | ≤ ±0.3% |
| Flow Precision | ≤ 0.075% RSD |
| Pressure Pulsation | ≤ 0.1 MPa |
| Brand | EasyTest |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | FOM/mts |
| Measurement Principle | Time-Domain Reflectometry (TDR) |
| Volumetric Water Content Range | 0–100% |
| Temperature Range | −20 to +50 °C |
| Bulk Electrical Conductivity Range | 0.000–1 S/m |
| VWC Accuracy | ±2% of reading |
| Temperature Accuracy | ±0.5 °C |
| EC Accuracy | ±0.01 S/m |
| VWC Resolution | 0.1% |
| Temperature Resolution | 0.1 °C |
| EC Resolution | 0.001 S/m |
| Measurement Time | <5 s |
| Operating Temperature | 0–50 °C |
| Dimensions | 180 × 85 × 58 mm |
| Weight | 0.35 kg (with battery) |
| Display | 160 × 128 pixel monochrome LCD |
| Pulse Shape | sin² waveform |
| Rise Time | 200 ps |
| Data Storage | 1,000 labeled measurements |
| Battery | 3.6 V, 1600 mAh Li-ion (no memory effect, auto-charging with overcharge protection) |
| Cable Length Options | 1.5–6.0 m |
| Storage Temp. | −10 to +50 °C |
| Maintenance Interval | Recharge every 3–4 months |
| Brand | easyXAFS |
|---|---|
| Origin | USA |
| Model | XAFS300 / XAFS300+ |
| X-ray Source Power | XAFS mode: 2500 W |
| XES mode | 100 W |
| Monochromatic X-ray Flux | 3–4 × 10⁶ photons/sec |
| Elemental Energy Range | 4.5–25 keV |
| Energy Resolution | 0.5–1.5 eV |
| Testable Elements | ~70 elements |
| Brand | easyXAFS |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | XES150 |
| X-ray Source Power | XAFS Mode: 1.2 kW (Mo/W anode, for XRD-compatible operation) |
| XES Mode | 100 W (Pd/W anode, air-cooled microfocus tube) |
| Monochromatic X-ray Flux | XAFS: 300,000–500,000 photons/s (7–9 keV) |
| XES | 100,000–150,000 photons/s (7–9 keV) |
| Minimum Detectable Elemental Concentration | 0.1 wt% |
| Tunable X-ray Absorption Energy Range | 4.9–20.5 keV |
| XAFS Scan Speed | 0.1–2.0 eV/s |
| Brand | East & West Analytical Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer | East & West Analytical Instruments Co., Ltd. |
| Instrument Type | TOF Mass Spectrometer |
| Resolution | ≥2500 (FWHM) |
| Sensitivity | 250 amol/μL Febrinopeptide Human B (S/N ≥50:1) |
| Mass Stability | ≤300 ppm relative deviation in m/z over 8 h |
| Sampling Rate | 2 GS/s |
| Mass Accuracy | ≤200 ppm (internal calibration), ≤300 ppm (external calibration) |
| Brand | East & West Analytical Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | TOF Mass Spectrometer |
| Model | Ebio Reader 3700 |
| Resolution | ≥2500 (FWHM) |
| Sensitivity | 250 amol/μL for Human Fibrinopeptide B |
| Mass Stability | ≤300 ppm relative mass drift over 8 hours |
| Sampling Rate | 2 GS/s |
| Mass Accuracy | ≤200 ppm (internal calibration), ≤300 ppm (external calibration) |
| Laser | N₂ laser, 337 nm, 1–60 Hz repetition rate, lifetime ≥9×10⁷ shots |
| Flight Tube Material | Low-thermal-expansion alloy |
| Vacuum System | Oil-free diaphragm pump |
| Data Acquisition | FPGA-accelerated digitizer with on-board spectral preprocessing |
| Ion Mode | Positive-mode standard |
| Brand | GKINST |
|---|---|
| Model | EC120 |
| Temperature Range | –50 °C to +120 °C |
| Max. Heating/Cooling Rate | 30 °C/min |
| Temp. Stability | < 0.05 °C |
| Temp. Resolution | 0.01 °C |
| Sensor | PT100 Platinum Resistance Thermometer |
| Control Algorithm | PID Dynamic Regulation |
| Compatibility | Liquid-phase electrochemical cells (e.g., coin-cell, pouch-cell, fuel cell configurations) |
| Compliance | Designed for integration with X-ray diffractometers (XRD), synchrotron beamlines, and in situ/operando electrochemical characterization platforms |
| Brand | GKInst |
|---|---|
| Origin | Anhui, China |
| Model | EC150 |
| Temperature Range | −50 °C to +150 °C |
| Max. Heating/Cooling Rate | 30 °C/min |
| Temp. Stability | < 0.05 °C |
| Temp. Resolution | 0.01 °C |
| Sensor | PT100 Platinum Resistance Thermometer |
| Control Algorithm | PID Dynamic Regulation |
| Compliance | Designed for ASTM D3418, ISO 11357, and IEC 62660-2 thermal cycling protocols in electrochemical cell characterization |
| Brand | ECH |
|---|---|
| Origin | Germany |
| Model | MobilGC 2 |
| Detection Range | 1 ppm to 100 % |
| Repeatability | ±0.1 ppm |
| Weight | 23 kg |
| Dimensions | 500 × 457 × 305 mm (W × H × D) |
| Detectors | FID and TCD/WLD |
| Column Support | Capillary, packed, and micro-packed columns |
| Column Heating | Independent, programmable up to 250 °C (isothermal or temperature gradient) |
| Carrier Gases | Argon, nitrogen, helium, or hydrogen |
| Integrated Gas Supply | Sufficient for ~40 hours of continuous operation |
| Methanizer | Optional CO/CO₂-to-CH₄ conversion module |
| Data Acquisition | Digital, real-time |
| Software | Integrated control, automated peak integration (single & total), application-specific expert evaluation routines |
| Compliance | Designed for GLP-compliant workflows |
| Brand | ECI Technology |
|---|---|
| Origin | USA |
| Model | CVS V10 / V20 / V30 |
| Application | Electrochemical Analysis of Organic Additives & Inorganic Components in PCB and Advanced Metal Deposition Baths |
| Measurement Principle | Cyclic Voltammetric Stripping (CVS), Modified Linear Anodic Stripping (MLAT), Dual Titration (DT), Reverse Dual Titration (RDT), Chronoamperometry (CA), Chronopotentiometry (CP) |
| Optional Modules | Potentiometric Titration, Conductivity, UV-Vis Spectrophotometry |
| Automation Capacity | 0–42 Samples per Run |
| Temperature Control | Integrated Peltier-regulated Cell Holder (±0.1 °C) |
| Software Compliance | FDA 21 CFR Part 11–ready Audit Trail, Electronic Signatures, GLP/GMP Data Integrity Framework |
| Communication | TCP/IP, LIMS Integration via ASTM E1384 / ISO/IEC 17025–compatible API |
| Brand | AZ (Beijing Aozuo) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Benchtop |
| Integration | Fully Integrated System |
| Laser Source | Nd:YAG, 200 mJ @ 1064 nm (266 nm optional) |
| Repetition Rate | 20 Hz |
| Pulse Width | <6 ns |
| Spot Size | 20–200 µm (motorized adjustment) |
| Spectral Range | 190–1040 nm |
| Detector | Back-illuminated CCD with auto-height alignment |
| Safety Class | I (interlocked laser enclosure) |
| Software | ElementLIBS & NIST spectral libraries, PLS/PCA modeling, mapping, autofocus, dual-lens control (wide-field + magnified), gas flow regulation, soil/plant calibration databases |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Regional Origin | Domestic (PRC) |
| Model | Ecodrone® |
| Pricing | Upon Request |
| Operating Principle | Push-broom Scanning |
| Imaging Method | Dispersive Optics |
| Deployment Mode | Airborne |
| Spectral Range | 400–1000 nm / 900–1700 nm (Hyperspectral), 905 nm (LiDAR) |
| Spectral Resolution | 5.5 nm (VNIR) |
| Ground Sampling Distance (GSD) | 3.5 cm @ 50 m AGL |
| Total Field of View (TFOV) | 38° |
| Instantaneous Field of View (IFOV) | 1024 × 640 pixels |
| Frame Rate | 330 FPS (HSI), 670 FPS (LiDAR) |
| Origin | Shaanxi, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | Ecodrone®-Kestrel |
| Pricing | Upon Request |
| Operating Principle | Push-broom |
| Imaging Method | Dispersive (Prism-based) |
| Deployment Mode | Ground-based & Airborne Compatible |
| Spectral Range | 400–1000 nm |
| Spectral Resolution | 2.6 nm (FWHM) |
| Spatial Resolution (Detector Array) | 2048 pixels per line |
| Total Field of View (TFOV) | 40° |
| Instantaneous Field of View (IFOV) | 2048 × 1 pixel array (sensor-native sampling) |
| Frame Rate | 100 Hz |
| Brand | Ecom (Czech Republic) |
|---|---|
| Origin | Czech Republic |
| Model | PREPBOX A3L8E |
| Application Level | Industrial-Scale Preparative |
| Instrument Type | High-Pressure Preparative HPLC System |
| Flow Rate Range | 50–250 mL/min |
| Flow Rate Reproducibility | ±0.5% RSD (at 500 mL/min) |
| Maximum Pressure | 30 MPa |
| Wavelength Range | 200–800 nm |
| Wavelength Accuracy | ±0.4 nm |
| Detector Type | TOY18DAD 800L Four-Channel UV-Vis Diode Array Detector |
| Gradient Capability | Low-Pressure Quaternary Mixing (up to 4 solvents) |
| Fraction Collection | 10-position Valve-Based Fraction Collector |
| Control Software | ECOMAC v4.x (Embedded PC Platform) |
| Dimensions (W×H×D) | 405 × 490 × 525 mm |
| Weight | 55 kg |
| Power Supply | 100–240 V AC, 400 W |
| Interfaces | 5× USB, HDMI, 2× RS232, LAN, VGA |
| Brand | EcoTech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | Ecodrone-LiHT |
| Pricing | Upon Request |
| Operating Principle | Push-broom |
| Imaging Method | Dispersive |
| Deployment Mode | Airborne |
| Spectral Range | 400–1000 nm |
| Spectral Resolution | 5.5 nm |
| Spatial Resolution (Hyperspectral) | 1024 pixels per line |
| Field of View (TFOV) | 38° |
| Frame Rate | 230 Hz |
| Thermal Sensor Resolution | 640 × 512 (standard), up to 1266 × 1010 (IR high-res mode) |
| Thermal Sensitivity | ≤0.03 °C |
| LiDAR Accuracy | 2.5 cm (standard), optional upgrade to 0.5 cm |
| LiDAR Return Channels | Up to 3 (standard), up to 15 (optional) |
| Point Density at 50 m AGL | ≥700 pts/m² |
| Brand | EdgeTech |
|---|---|
| Origin | USA |
| Model | DPS |
| Type | Online Dew Point Meter |
| Principle | Chilled-Mirror Condensation |
| Operating Temperature Range | 20–99 °C |
| Accuracy | ±0.2 °C |
| Repeatability | ±0.05 °C |
| Brand | Edinburgh Analytical |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | DB30 |
| Instrument Architecture | Dual-Beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.1 nm |
| Wavelength Repeatability | ±0.1 nm |
| Spectral Bandwidth | 0.5, 1.0, 1.5, 2.0, 4.0 nm |
| Stray Light | ≤0.1% |
| Automation Level | Automatic Wavelength Scanning |
| Scan Speed | Up to 6000 nm/min |
| Brand | Edinburgh Analytical |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Steady-State Fluorescence Spectrometer |
| Wavelength Range | 200–900 nm |
| Excitation Source | Xenon Arc Lamp |
| Monochromator | Grating-Based |
| Slit Width | Adjustable (Multiple Bandwidths) |
| Spectral Resolution | 1.0 nm |
| Wavelength Accuracy | ±2.0 nm |
| Signal-to-Noise Ratio (S/N) | 15,000:1 |
| Maximum Scan Speed | 60,000 nm/min |
| Software | Spectracle™ |
| Brand | Edinburgh Analytical |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Laboratory Benchtop FTIR Spectrometer |
| Wavenumber Range | 350–8000 cm⁻¹ |
| Spectral Resolution | 0.5 cm⁻¹ |
| Signal-to-Noise Ratio (SNR) | 20,000:1 (at 4 cm⁻¹, 1 min scan, MCT detector) |
| Wavenumber Accuracy | ±0.05 cm⁻¹ |
| Optical Design | Michelson Interferometer with KBr Beamsplitter and Dynamically Aligned Mirror Drive |
| Brand | Edinburgh Instruments |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | FLS1000 |
| Dispersion Element | Grating Monochromator |
| Instrument Type | Steady-State and Time-Resolved Fluorescence Spectrometer |
| Slit Width (Spectral Bandpass) | 0–30 nm |
| Optical Resolution | 0.05 nm |
| Sensitivity | 35,000:1 (RMS method) |
| Wavelength Accuracy | ±0.2 nm |