| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | TP-304 |
| Price | Upon Request |
| Brand | Spectrolight |
|---|---|
| Origin | Switzerland |
| Model | IRsweep IRis-F1 |
| Instrument Type | Laboratory Benchtop Laser-Based Infrared Spectrometer |
| Light Source Technology | Dual Quantum Cascade Laser (QCL) Frequency Comb |
| Time Resolution | 1 µs |
| Spectral Resolution | 0.25–0.5 cm⁻¹ |
| Spectral Range | Mid-Infrared (Typical 1,200–3,000 cm⁻¹, configurable) |
| Compliance | CE, RoHS, ISO 9001-certified manufacturing |
| Software Environment | IRsweep Control Suite v4.x (Windows-based, FDA 21 CFR Part 11-ready audit trail option) |
| Brand | IRsweep |
|---|---|
| Origin | Switzerland |
| Model | IRis-F1 |
| Technology | Dual-Comb Quantum Cascade Laser (QCL) Infrared Spectroscopy |
| Time Resolution | 1 µs |
| Spectral Resolution | 0.25–0.5 cm⁻¹ |
| Spectral Range | Mid-IR (typically 1200–2200 cm⁻¹, configurable) |
| SNR | High (optimized for trace-level detection) |
| Sample Compatibility | Solid, Liquid, Gas |
| Compliance | CE, RoHS, ISO 9001-certified manufacturing |
| Brand | ISCO |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CombiFlash EZ Prep |
| Application Level | Laboratory Grade |
| Instrument Type | High-Pressure Preparative Liquid Chromatography System |
| Flow Rate Range | 0–200 mL/min |
| Flow Rate Precision | RSD ≤ 1% |
| Maximum Operating Pressure | 3500 psi (240 bar) |
| Wavelength Range | 200–400 nm (UV), 200–800 nm (UV-VIS) |
| Wavelength Accuracy | ±1 nm |
| Baseline Noise | 1 × 10⁻⁵ AU |
| Data Acquisition Rate | 200 Hz |
| Column Compatibility | Up to 50 mm ID, down to 5 µm particle size packing |
| Solvent Switching | Fully Automated, User-Initiated or Method-Triggered (Normal-Phase to Reversed-Phase) |
| Brand | ISCO |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CombiFlash NextGen |
| Application Level | Laboratory Grade |
| Instrument Type | Medium-to-Low Pressure Preparative LC |
| Flow Rate Range | 1–300 mL/min |
| Flow Accuracy | RSD ≤ 0.01% |
| Flow Precision | RSD ≤ 0.1% |
| Maximum Operating Pressure | 300 psi (20 bar) |
| Wavelength Range | 190–800 nm (UV-Vis) |
| Wavelength Reproducibility | ±1 nm |
| Baseline Noise | ≤1 × 10⁻⁵ AU |
| Data Acquisition Rate | 5 Hz |
| Detection Options | UV, UV-Vis, ELSD, Mass Spectrometry (MS)-compatible interface |
| Brand | ISCO |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CombiFlash Torrent |
| Application Level | Industrial-Scale Preparation |
| Instrument Type | Medium-to-Low Pressure Preparative LC |
| Flow Rate Range | 1 L/min |
| Flow Accuracy | <1% |
| Flow RSD | <1% |
| Maximum Operating Pressure | 100 psi |
| Wavelength Range | 190–800 nm (UV-Vis) |
| Wavelength Accuracy | ±1 nm |
| Wavelength Reproducibility | ±1 nm |
| Sample Capacity | Up to 600 g per run |
| Column Compatibility | RediSep® (80 g – 3 kg), glass columns, third-party cartridges |
| Software | PeakTrak™ v5.0 with real-time gradient editing, method scaling, and RFID-enabled column recognition |
| Detection | Dual-wavelength UV/Vis detector with auto-zero baseline correction |
| Fraction Collection | Foxy R2 fraction collector or motorized 6-port switching valve |
| Safety Systems | Integrated pressure transducer, solvent vapor sensor, automatic shutdown on fault |
| Fluidic Architecture | Fully grounded stainless-steel and PEEK tubing, large-bore flow path |
| Brand | ISCO |
|---|---|
| Model | R1/R2 |
| Instrument Type | Liquid-Phase Fraction Collector |
| Collection Modes | Volume-, Time-, Drop-, and Peak-Triggered |
| Maximum Flow Rate | 100 mL/min |
| Dimensions (R1) | 31 × 33 × 35.5 cm |
| Dimensions (R2) | 31 × 53 × 38 cm |
| Weight (R1, without rack) | 7.7 kg |
| Weight (R2, without rack) | 10.6 kg |
| Power Supply | 115 VAC or 230 VAC, 50/60 Hz |
| Tube Rack Options | 144-12, 144-13, 100-16, 72-18, 36-25, 60-1.5, 36-50, 96-well plate compatible |
| Safety Features | Leak detection, electrical insulation protection |
| Mounting | Optional instrument stand for space optimization |
| Origin | Sweden |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Isolera™ One |
| Price Range | USD 42,000–56,000 (est.) |
| Application Level | Laboratory-Scale Purification |
| Instrument Type | Medium-Pressure Preparative LC System |
| Flow Rate Range | 1–200 mL/min |
| Maximum Operating Pressure | 200 psi (13.8 bar) |
| UV Detection Wavelength Range | 200–400 nm |
| Gradient Capability | Binary with Optional Tertiary Solvent Addition (Constant-Ratio Modifier Injection) |
| Column Compatibility | Biotage SNAP, SNAP Ultra, ZIP, and ZIP Sphere columns (5 g to 750 g) |
| Brand | Princeton Instruments (Teledyne) |
|---|---|
| Origin | USA |
| Model | IsoPlane SCT-320, IsoPlane 160 |
| Focal Length | 320 mm (SCT-320), 203 mm (160) |
| Aperture Ratio | f/4.6 (SCT-320), f/3.88 (160) |
| Spectral Resolution (PMT) | 0.05 nm (SCT-320), 0.10 nm (160) |
| Spectral Resolution (CCD, 1200 gr/mm, 435 nm, 20 µm pixels, 10 µm slit) | 0.08 nm (SCT-320), 0.15 nm (160) |
| Grating Mount | Motorized triple-grating turret with auto-recognition |
| Wavelength Range | UV to mid-IR (193 nm–>5 µm, depending on grating & detector) |
| Optical Coating Options | Acton #1900 enhanced Al (193 nm–mid-IR), protected Ag (>98% avg. reflectance), Au (NIR/SWIR) |
| Detector Compatibility | PIXIS, ProEM, PI-MAX4, NIRvana series |
| Software Platform | LightField v8+ (64-bit), supports LabVIEW, MATLAB, EPICS, and FDA 21 CFR Part 11-compliant audit trail modules |
| (brand | Pri-eco |
|---|---|
| origin | Beijing, China |
| manufacturer | Pri-eco |
| type | benchtop isotope ratio mass spectrometer |
| model | Isotope5 CNS |
| measurement range | δ¹³C, δ¹⁵N, δ³⁴S, δ³²S |
| resolution | >75 at m/z 29) |
| Brand | ISOTOPX |
|---|---|
| Origin | United Kingdom |
| Model | NGX-600 |
| Instrument Type | Rare Gas Isotope Ratio Mass Spectrometer |
| Mass Range | 1–200 Da |
| Resolution | 400–600 |
| Detection System | Configurable Faraday Cup and Ion Counter Electron Multiplier Array |
| Standard Amplifier | ATONA Amplifier |
| Vacuum System | Compact Static Vacuum Gauge |
| Ion Source | High-Sensitivity Nier-Type Source |
| Brand | ISPEC |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Regional Classification | Domestic |
| Model | Analytical System |
| Quotation | Upon Request |
| Instrument Category | Spectral Software & Database Suite |
| Instrument Type | Laboratory-Based |
| Wavenumber Range | 4000–400 cm⁻¹ |
| Resolution | 1 cm⁻¹ |
| Brand | ISS |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Hpcell-00 |
| Price Range | USD 2,800 – 7,000 |
| Maximum Pressure | 400 MPa (4 kbar / 43,500 psi) |
| Optical Windows | Three 10 mm diameter fused silica windows, 90° angular distribution |
| Optional Window Material | Sapphire |
| Configurable Window Count | 3 or 4 |
| Compatible With | Fluorescence spectroscopy, time-resolved fluorescence, UV-Vis absorption spectroscopy |
| Integration Method | Direct mounting on optical tables or fiber-coupled interface with commercial spectrometers |
| Brand | COX Analytical Systems |
|---|---|
| Origin | Sweden |
| Model | Itrax XRF FleXRay |
| Form Factor | Benchtop/Floor-Standing |
| Application Domain | Geological & Mining Core Analysis |
| Elemental Range | Na–U |
| Detection Principle | Energy-Dispersive X-Ray Fluorescence (ED-XRF) |
| Optical Resolution | High-Resolution RGB Imaging System |
| Surface Topography Compensation | Integrated Laser Distance Sensor (8 mm Fixed Working Distance) |
| Data Acquisition Speed | 0.2 s per measurement point |
| Sensitivity | Sub-ppm for heavy and transition metals |
| Calibration Approach | Pre-loaded Standard Reference Material Libraries |
| Compliance Context | Designed for GLP-compliant sediment core laboratories |
| Origin | Sweden |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | XRF Scanner |
| Price Range | USD 27,000 – 68,000 (FOB) |
| Brand | Bunkoukeiki (Japan) |
|---|---|
| Origin | Japan |
| Model | IUV-25CP-1 |
| Wavelength Range | ~240 nm (continuous irradiation band) |
| Irradiation Area (Vertical) | 89 mm (5–13 adjustable steps) |
| Irradiation Area (Wavelength Direction) | 80 mm (~240 nm spectral span) |
| Exposure Time | 0.01–1200 s |
| Exposure Steps | 1–13 |
| Light Sources | Deep UV Mercury Lamp (line spectrum) + Xenon Arc Lamp (broadband continuum) |
| Brand | IVEA |
|---|---|
| Origin | France |
| Model | easyLIBS |
| Instrument Type | Handheld |
| Integration | Modular |
| Laser Source | Dual-Pulse Nd:YAG, 1064 nm |
| Spot Size | ~300 µm |
| Detection Limit | 1–500 ppm (element-dependent) |
| Weight (system with case) | <7 kg |
| Power Supply | Integrated portable battery pack |
| Software | AnaLIBS (included on dedicated laptop) |
| Optical Collection | Co-aligned laser focusing & plasma signal collection optics |
| Imaging | Built-in CMOS camera for real-time sample surface visualization |
| Fiber Spectrometer Options | User-selectable, multiple wavelength ranges available |
| Brand | IVEA |
|---|---|
| Origin | France |
| Model | MEEPLIBS |
| Instrument Type | Online LIBS System |
| Integration | Fully Integrated |
| Spatial Resolution | Down to 4 µm (Standard Apertures: 15 µm and 18 µm) |
| Operating Environment | Ambient Air at Room Temperature (Configurable for Controlled Atmospheres) |
| Laser Source | Q-Switched Nd:YAG, 266 nm UV, Software-Tunable Pulse Energy with Beam Shaping & Attenuation |
| Sample Handling | Motorized XYZ Translation Stage with Real-Time CCD Imaging Feedback |
| Elemental Coverage | H to U (All Elements, Including Light Elements) |
| Sample Preparation | None Required |
| Brand | IVEA |
|---|---|
| Origin | France |
| Model | YAG 266 nm, 20 Hz |
| Form Factor | Benchtop |
| Integration | Fully Integrated |
| Laser Type | Q-switched Nd:YAG (4th harmonic) |
| Wavelength | 266 nm |
| Repetition Rate | 20 Hz |
| System Architecture | Modular (4 units, ~30 kg each) |
| Sample Compatibility | Solids, Liquids, Gases, Opaque & Transparent Materials |
| Optical Path | Motorized Focus Adjustment |
| Detection Range | Typically 190–850 nm (configurable per spectrometer module) |
| Compliance | CE-marked, RoHS-compliant |
| Brand | Ivium |
|---|---|
| Origin | Netherlands |
| Model | CompactStat.h |
| Instrument Type | Portable Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Range | ±1 pA to ±10 mA (12 ranges: 1 pA, 10 pA, 100 pA, 1 nA, 10 nA, 100 nA, 1 µA, 10 µA, 100 µA, 1 mA, 10 mA) |
| Current Accuracy | ±0.2% of reading |
| Potential Accuracy | ±0.2% of reading |
| Potentiostatic Range | −10 V to +10 V |
| EIS Frequency Range | 10 µHz to 3 MHz |
| Current Resolution | down to 0.6 aA (at selected range) |
| Potential Resolution | down to 0.07 nV (at selected range) |
| Applied Signal Resolution | 0.00013% |
| Measurement Resolution (current) | 0.00006% of selected range |
| Brand | Ivium |
|---|---|
| Origin | Netherlands |
| Model | CompactStat.h10800 |
| Instrument Type | Portable Electrochemical Workstation |
| Number of Channels | Single-Channel |
| Current Range | 1 pA, 10 pA, 100 pA, 10 nA, 100 nA, 1 µA, 10 µA, 100 µA, 1 mA, 10 mA, 100 mA, 1 A (13 ranges) |
| Current Accuracy | 0.00006% of selected range, minimum 0.6 aA |
| Potential Accuracy | 0.003% of selected range, minimum 16 nV |
| Potentiostatic Range | −10 V to +10 V |
| EIS Frequency Range | 10 µHz to 3 MHz |
| Brand | Ivium |
|---|---|
| Origin | Netherlands |
| Model | CompactStat.h20250 |
| Instrument Type | Portable Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Range | ±1 pA to ±250 mA |
| Current Accuracy | ±0.2% of reading |
| Potential Accuracy | ±0.003% of range (minimum 16 nV) |
| Potentiostatic Range | −20 V to +20 V |
| Impedance Frequency Range | 10 µHz to 3 MHz |
| Potential Resolution | 0.00001% of selected range (min. 0.15 nV) |
| Current Resolution | 0.00006% of selected range (min. 0.6 aA) |
| Applied Current Resolution | 0.00013% |
| Applied Potential Resolution | 16 nV |
| Brand | Ivium |
|---|---|
| Origin | Netherlands |
| Model | Current Interrupt Module |
| Instrument Type | Electrochemical Instrument Accessory |
| Application | iR Compensation via Current Interruption Method |
| Connectivity | Direct integration with Ivium potentiostat electrode cable assemblies |
| Compliance Context | Designed for use in ASTM G102-compliant corrosion testing and ISO 17475 electrochemical impedance validation workflows |
| Key | Brand: Ivium |
|---|---|
| Origin | Netherlands |
| Model | HE80 |
| Channel Count | Single-Channel |
| Current Range | 0–80 A |
| Current Accuracy | ±0.3 mA |
| Potential Accuracy | ±14 nV |
| Potentiostatic Range | +0.5 V to +20 V |
| EIS Frequency Range | 10 µHz–10 kHz |
| Maximum Data Acquisition Rate | 300,000 pts/s |
| Minimum Time Interval | 3.33 µs (0.125 µs resolution) |
| Real-Time Sampling Rate | Up to 500 pts/s |
| Dimensions | 44 × 37 × 8.8 cm |
| Weight | 15 kg |
| Electrode Configuration | 4-Electrode Connection |
| Integrated FRA/EIS | Yes |
| Brand | Ivium |
|---|---|
| Origin | Netherlands |
| Model | HiMUX.XR |
| Instrument Type | Electrochemical Sample Switcher |
| Channel Capacity | 8 independent channels |
| Max Current (WE–CE) | 5 A |
| Electrode Configuration per Channel | 4-electrode (WE, CE, RE, SE) |
| Compatible Systems | IviumStat, CompactStat series |
| Independent Galvanostats per Channel | Yes |
| Leakage Capacitance | Ultra-low |
| High-Frequency Performance | Uncompromised |
| Software Control | Automatic channel selection integrated in IviumSoft |
| Brand | Ivium |
|---|---|
| Origin | Netherlands |
| Model | IviumBoost |
| Type | Electrochemical Instrument Accessory |
| Output Voltage/Current/Frequency Ranges | IviumBoost1001 — 100 V / 0.5 A / 250 kHz |
| Brand | Ivium |
|---|---|
| Origin | Netherlands |
| Model | MultiWE32 |
| Electrode Channel Capacity | 32 working electrodes (expandable to 256) |
| Compatible Systems | Ivium potentiostats/galvanostats |
| Measurement Modes | Simultaneous LSV, CV, and EIS on all channels |
| Reference/Counter Electrode Configuration | Shared RE/CE pair |
| Compliance | Designed for ISO/IEC 17025-compliant electrochemical labs |
| Brand | Ivium |
|---|---|
| Origin | Netherlands |
| Model | Octo Stat |
| Max Current per Channel | ±200 mA / ±5 A (selectable) |
| Max Voltage | ±10 V |
| Current Range | ±10 nA to ±100 mA (standard), extendable to ±10 A |
| EIS Frequency Range | 10 µHz – 100 kHz |
| Onboard Data Storage | 20 million data points per channel |
| Interface | USB 2.0 & 10/100 Mbps Ethernet |
| Rack Mount | 19-inch standard |
| Standalone Operation | Yes (fully embedded control firmware) |
| Software | IviumSoft (battery cycling, EIS, polarization, corrosion analysis modules) |
| Brand | Ivium |
|---|---|
| Origin | Netherlands |
| Model | Peripheral Differential Amplifier |
| Input Impedance | >1000 GΩ |
| Differential Input Range | ±2 V |
| Channels per Module | 8 |
| Expandable to | 64 channels |
| Instrument Type | Electrochemical Instrument Accessory |
| Category | Electrochemical Instrument Accessories |
| Brand | Ivium |
|---|---|
| Origin | Netherlands |
| Model | Peripheral Port Expander |
| Type | Electrochemical Instrument Accessory |
| Function | External Signal I/O Expansion Module |
| Analog Inputs | 8 channels |
| Analog Outputs | 2 channels |
| Digital Inputs | 2 channels |
| Digital Outputs | 3 channels |
| Dedicated Outputs | Current (I-out), Potential (E-out), AC Output (ACout) |
| Impedance Input Channels | X and Y (for lock-in or phase-sensitive detection) |
| Connector Type | Standard BNC and screw-terminal interfaces |
| Compatibility | Designed exclusively for Ivium electrochemical workstations (e.g., IviumStat, CompactStat, Vertex series) |