Chemical Analysis Instruments
Filter
Showing 2641–2670 of 4426 results
| Origin | Czech Republic |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | MS-96 |
| Price Range | USD 42,000 – 70,000 |
| Origin | Finland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MSHyperSIS-VNIR |
| Price Range | USD 14,000 – 43,000 (FOB) |
| Operating Principle | Push-broom scanning |
| Imaging Mode | 3D spatial-spectral data cube acquisition |
| Deployment Platform | Terrestrial (ground-based) |
| Spectral Range | 400–1000 nm |
| Spectral Resolution | 0.025 nm (FWHM) |
| Spatial Resolution | 1392 × 1040 pixels |
| Total Field of View (TFOV) | 5° |
| Instantaneous Field of View (IFOV) | 0.05° |
| Frame Rate | 25–120 fps |
| Standard Lens Focal Length | 17 mm |
| Vertical FOV | 40° |
| Horizontal FOV | 70° |
| Scan Speed | ≤100 images/s (CCD-dependent) |
| Brand | HUANKONG |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic |
| Model | APK2600C |
| Instrument Type | Multifunctional Autosampler |
| Max Sample Capacity | 60 × 1.8 mL vials (2 racks) |
| Minimum Injection Volume | 0.1 µL |
| Standard Loop Volume | 100 µL |
| Positioning Accuracy | < 0.3 mm |
| Motion Architecture | XYZ Three-Axis |
| Needle Wash Mode | Internal & External Wall Rinse (Unlimited Cycles) |
| Repeat Injection Capability | Unlimited |
| Purge Function | Not Integrated |
| Observation Window | Integrated |
| Particulate Filtration Module | Included |
| Brand | Auniontech (HaoLiang) |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | Nanalysis 100 MHz |
| Operating Frequency | 100 MHz (2.35 T) |
| Magnet Type | Permanent, Cryogen-Free |
| Nuclei Support | Dual-Tuned Probes (e.g., ¹H/¹³C, ¹H/³¹P, ¹H/¹⁹F, ¹H/¹¹B, ¹⁹F/⁷Li) |
| Lock Channel | ¹H or ²H |
| Sample Format | Standard 5 mm NMR tubes |
| Resolution | <1.0 Hz (at 100 MHz) |
| Sensitivity | 220:1 (1% ethylbenzene in CDCl₃) |
| Data Formats | JCAMP-DX, Delta, ACD/Labs, TopSpin, LabVIEW, MATLAB |
| Operating Temperature | 16–28 °C |
| Power Input | 100–240 VAC, 50–60 Hz |
| Dimensions | 37.1 × 41.4 × 65.5 cm (14.6 × 16.3 × 25.8 in) |
| Weight | 84 kg |
| User Interface | Integrated touchscreen PC + remote access capability |
| Compliance | Designed for GLP-compliant environments |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | NanoDrop Eight |
| Optical Design | Dual-beam |
| Detector | CCD Array |
| Wavelength Range | 190–850 nm |
| Wavelength Automation | Fully Automatic |
| Spectral Bandwidth | ≤1.8 nm |
| Wavelength Accuracy | ±1 nm |
| Stray Light | ≤0.01% T |
| Brand | NanoMagnetics |
|---|---|
| Origin | United Kingdom |
| Model | LT-AFM/MFM |
| Cooling System | Cryogen-Free Closed-Cycle Cryostat |
| Temperature Range | 1.5 K – 400 K (base temperature ≤1.5 K) |
| Maximum Magnetic Field | 20 T |
| Vibration Isolation | Active + Passive Vibration-Free Design |
| Operation Mode | Fully Dry, Helium-Free |
| Sample Stage Travel (Z) | 10 mm |
| Sample Stage Travel (XY) | Ø3 mm |
| Sample Positioning Resolution | 2 µm (capacitive encoder) |
| Sample Dimensions (max) | 15 × 15 × 5 mm |
| Electrical Interface | 5-pin sample holder (1 bias + 4 auxiliary channels) |
| Environmental Compatibility | UHV-compatible, exchange-gas capable, PPMS®-integrated, Evercool®-compatible, dilution refrigerator & He-3 system adaptable |
| Brand | NanoMagnetics |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LT-SHPM/STM |
| Pricing | Available Upon Request |
| Temperature Range | 10 mK – 400 K |
| Magnetic Field Range | Up to 20 T |
| Spatial Resolution (Z) | 50–800 nm (stick-slip approach) |
| Scan Range (XY) | Ø3 mm |
| Z-Travel | 10 mm |
| Sample Dimensions | Max. 15 × 15 × 5 mm |
| Magnetic Noise Floor | 10 µT/√Hz @ 300 K, 100 nT/√Hz @ 77 K, 10 nT/√Hz @ 4 K |
| Compatibility | PPMS®, dry magnet systems, dilution refrigerators (DRs), He-3 cryostats |
| Optional Module | 3D-SHPM for vectorial magnetic field mapping |
| Brand | NanoMagnetics |
|---|---|
| Origin | United Kingdom |
| Model | mK-CFM/RAMAN |
| Temperature Range | 10 mK – 300 K |
| Magnetic Field | Up to 31 T |
| Objective | 0.82 NA, 0.95 mm Working Distance APO Cryo-Objective |
| Scan Range (300 K) | 50 × 50 × 25 µm |
| Scan Range (4 K) | 30 × 30 × 15 µm |
| Coarse Approach Range | 6 × 6 × 12 mm (XYZ), Step Size: 50–700 nm |
| Closed-Loop Encoder Resolution | 200 nm |
| Fine Scan Range (300 K) | 7.5 µm |
| Fine Scan Range (4.2 K) | 1 µm |
| Max Sample Dimensions | 10 × 10 × 5 mm |
| Sample Holder | 8-pin electrical feedthrough |
| Environmental Compatibility | Ultra-high vacuum (UHV) or purged gas atmosphere |
| Cryostat Compatibility | Compatible with standard 50 mm cold-finger dilution refrigerators and most commercial cryogenic platforms |
| Brand | NanoMagnetics |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | NV |
| Pricing | Upon Request |
| Objective NA | 0.82 (Achromatic Apochromatic, 0.95 mm clear aperture) |
| Excitation Laser | 532 nm single longitudinal mode, 10 mW |
| Operating Temperature Range | 10 mK – 300 K |
| Scan Range (at 4 K) | 30 × 30 × 15 µm |
| Detector | Avalanche Photodiode (APD) for optical readout |
| Sample Stage | 6 × 6 × 12 mm XYZ piezo nanopositioner |
| NV/QTF Sensor Stage | 4 × 4 × 6 mm XYZ nanopositioner |
| Position Sensing | Resistive sensor, 200 nm resolution |
| Controller | FPGA-based AFM/SPM controller with USB 3.0 interface |
| Real-time Processor | 32-bit, 128 MB DDR SDRAM |
| ADC | Dual-channel 16-bit @ 100 MHz |
| DAC | Dual-channel 16-bit @ 100 MHz |
| On-FPGA PID Loops | 7 independent channels |
| Piezo Driver Channels | 19-channel high-voltage piezo controller |
| Auxiliary ADC | 16-channel 24-bit @ 175 kHz |
| Scan DAC | 24-bit for XYZ raster scanning |
| High-Voltage Amplifier | Low-noise, wide-bandwidth |
| Brand | Metrohm |
|---|---|
| Origin | USA |
| Manufacturer | Metrohm AG |
| Instrument Type | Portable Handheld Raman Spectrometer |
| Spectral Range | 176–2500 cm⁻¹ |
| Excitation Wavelength | 1064 nm |
| Compliance | FDA 21 CFR Part 11, USP <858>, Ph. Eur. 2.2.48, JP 2.26, ChP 2020 Raman Spectroscopy General Chapter |
| Application Focus | GMP-compliant raw material identity testing (RMIT), incoming material verification, counterfeit detection |
| Brand | National Innovation Scientific Instruments |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | SuperXAFS M9000 |
| Price Range | USD 560,000 – 1,400,000 |
| Energy Range | 4.5–20 keV (upgradable to 25 keV) |
| Photon Flux at Sample | ≥4×10⁶ photons/s @ 7–9 keV |
| Energy Resolution | 0.5–1.5 eV @ 7–9 keV |
| Energy Reproducibility | ≤30 meV over 24 h |
| Minimum Energy Step Size | 0.1 eV |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic Laboratory X-ray Spectrometer |
| Model | NatureXAS 1500 |
| Pricing | Upon Request |
| Brand | NC Technologies |
|---|---|
| Origin | Italy |
| Model | ECS 4010 |
| Analysis Principle | High-Temperature Catalytic Combustion (Dumas Method) |
| Elements Determined | C, H, N, S (optional O) |
| Detection Method | Thermal Conductivity Detection (TCD) |
| Chromatographic Separation | Isothermal GC column (30–110 °C) |
| Automation Level | Fully Automated with Microprocessor Control |
| Sample Introduction | Pneumatic or Zero-Blank Electric Autosampler |
| Isotope Ratio Compatibility | Yes (for δ¹³C, δ¹⁵N, δ³⁴S, etc.) |
| Software | PC-based acquisition and reporting suite with audit trail capability |
| Compliance Support | Designed for GLP/GMP environments |
| Brand | NC Technologies |
|---|---|
| Origin | Italy |
| Model | ECS 4010 |
| Analysis Principle | High-Temperature Catalytic Combustion (Dumas Method) |
| Elements Measured | C, H, N, S (optional O) |
| Detection | Thermal Conductivity Detector (TCD), self-calibrating, reference-gas-free |
| Chromatographic Separation | Isothermal GC column (30–110 °C) |
| Automation Level | Fully automated microprocessor-controlled system with PC integration |
| Sample Introduction | Pneumatic and Zero-Blank electric autosamplers |
| Isotope Ratio Compatibility | Yes (MS-coupling enabled) |
| Compliance Framework | Designed for GLP/GMP environments |
| Brand | NC Technologies |
|---|---|
| Origin | Italy |
| Model | ECS 4024 |
| Analysis Principle | High-Temperature Catalytic Combustion (Dumas Method) |
| Elements Determined | C, H, N, S (O optional) |
| Detection Method | Thermal Conductivity Detection (TCD) |
| Gas Separation | Isothermal Chromatographic Column (30–110 °C) |
| Automation Level | Semi-Automatic |
| Software Interface | PC-Connected Dedicated Data Acquisition & Processing Software |
| Isotope Compatibility | Yes (via external MS coupling) |
| Sample Type | Homogeneous Solid or Liquid Organic Samples (Micro-Weighing Compatible) |
| Brand | NC Technologies |
|---|---|
| Origin | Italy |
| Model | ECS 4024 |
| Analysis Principle | High-Temperature Catalytic Combustion (Dumas Method) |
| Elements Determined | C, H, N, S (O optional) |
| Detection Method | Thermal Conductivity Detection (TCD) |
| Chromatographic Separation | Isothermal GC column (30–110 °C) |
| Automation Level | Semi-automatic |
| Software Interface | PC-based dedicated acquisition and reporting software |
| Isotope Compatibility | Compatible with IRMS (Isotope Ratio Mass Spectrometry) coupling |
| Sample Type | Homogeneous solid or liquid organic samples (micro-weighing capable) |
| Regulatory Alignment | Designed for GLP-compliant workflows |
| Brand | NC Technologies |
|---|---|
| Origin | Italy |
| Model | ECS 8020 |
| Analysis Principle | High-Temperature Catalytic Combustion (Dumas Method) |
| Elements Measured | C, H, N, S (O optional) |
| Detection Method | Thermal Conductivity Detection (TCD) |
| Chromatographic Separation | Isothermal GC column (30–110 °C) |
| Automation Level | Fully automated with microprocessor control and PC integration |
| Sample Introduction Options | Manual, Pneumatic, Electric Zero-Blank autosampler |
| Detector Features | Reference-gas-free TCD with auto-calibration |
| Interface Capability | IDMicro EA port for stable isotope ratio mass spectrometry (IRMS) coupling |
| Compliance Context | Designed for GLP/GMP-aligned workflows |
| Brand | NC Technologies |
|---|---|
| Origin | Italy |
| Model | ECS 8020 |
| Analysis Principle | High-Temperature Catalytic Combustion (Dumas Method) |
| Elements Determined | C, H, N, S (O optional) |
| Detection Method | Thermal Conductivity Detection (TCD) |
| Chromatographic Separation | Isothermal GC column (30–110 °C) |
| Automation Level | Fully automated with microprocessor control and PC integration |
| Sample Introduction Options | Manual, Pneumatic, Motorized Zero-Blank Autosampler |
| Detector Features | Reference-gas-free TCD with auto-calibration |
| Software Interface | Dedicated Windows-based acquisition and reporting software with audit trail capability |
| Compliance Support | Designed for GLP/GMP environments |
| Isotope Interface | Integrated IDMicro EA port for coupling to isotope ratio mass spectrometers (IRMS) |
| Power & Gas Management | Standby mode reduces carrier gas consumption (He or Ar), energy use, and idle time |
| Brand | NC Technologies |
|---|---|
| Origin | Italy |
| Model | ECS 8024 NC SOIL SPECIAL |
| Detection Principle | High-Temperature Catalytic Combustion (Dumas Method) |
| Elements Measured | Total Carbon (TC), Total Nitrogen (TN) |
| Optional Coupling | TIC DISCOVER for Total Inorganic Carbon (TIC) |
| Detector Type | Thermal Conductivity Detector (TCD) |
| Column Temperature Range | 30–110 °C |
| Sample Types | Soils, Fertilizers, Sludges, Sediments, Plant Tissues |
| Automation Level | Fully Automated with Motorized/Pneumatic/Manual Sampler Options |
| Software Control | PC-based with Touchscreen Interface |
| Compliance Ready | Supports GLP/GMP audit trails, ASTM D5373, ISO 10694, USP <281>, EN 15936 |
| Brand | NC Technologies |
|---|---|
| Origin | Italy |
| Model | ECS 8040 |
| Analysis Principle | High-Temperature Catalytic Combustion (Dumas Method) |
| Elements Measured | C, H, N, S (O optional) |
| Detection Method | Thermal Conductivity Detection (TCD) |
| Gas Separation | Isothermal Chromatographic Column (30–110 °C) |
| Automation Level | Fully Automated with Microprocessor Control and PC Integration |
| Sample Introduction Options | Manual, Pneumatic, Motorized Zero-Blank Autosampler |
| Compliance Ready | ASTM D5291, ISO 16968, USP <281>, EN 15104, DIN 51725 |
| Software Features | Real-Time Parameter Monitoring, Catalyst Life Tracking, Leak Detection, Audit Trail Logging (21 CFR Part 11–compliant mode available) |
| Brand | NC Technologies |
|---|---|
| Origin | Italy |
| Model | ECS 8040 |
| Analysis Principle | High-Temperature Catalytic Combustion (Dumas Method) |
| Elements Measured | C, H, N, S, O (O optional) |
| Detection Method | Thermal Conductivity Detection (TCD) |
| Gas Separation | Isothermal Capillary Chromatography (30–110 °C) |
| Automation Level | Fully Automated with Microprocessor Control & PC Integration |
| Sample Introduction Options | Manual, Pneumatic, Motorized Zero-Blank Autosampler |
| Detector Configuration | Dual TCD with Reference-Free Operation |
| Software | Dedicated Windows-Based Acquisition & Quantification Suite with Audit Trail Capability |
| Compliance Framework | Designed for GLP/GMP environments |
| Power Supply | 230 V AC, 50/60 Hz |
| Dimensions (W×D×H) | 700 × 650 × 550 mm |
| Weight | ~75 kg |
| Brand | NCS |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Floor-standing |
| Instrument Category | Scanning-type |
| X-ray Tube Power | 4 kW |
| Analyzable Elements | B to U |
| Beryllium Window Thickness | 75 μm (optional ≤75 μm variants) |
| Goniometer Angular Reproducibility | θ–2θ independent drive |
| Scan Ranges | SC (1–118°), PC (10–148°) |
| Step Angles | 0.001°, 0.002°, 0.005°, 0.01°, 0.02°, 0.05°, 0.1° |
| Brand | NCS |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | CS3500 |
| Measurement Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Heating System | High-Frequency Induction Furnace (18 MHz, 2.7 kVA) |
| Carbon Range | Low-C: 0.6 ppm–0.1 % |
| High-C | 0.1 %–50 % |
| Sulfur Range | Low-S: 0.6 ppm–0.3 % |
| High-S | 0.3 %–30 % |
| Sensitivity | 0.01 ppm |
| Precision | C: ±1 ppm or RSD < 0.5 % |
| S | ±1 ppm or RSD ≤ 1.0 % |
| Analysis Time | 30–40 s |
| Detector | Imported Pyroelectric Solid-State IR Detector (Germany) |
| Optical Source | Imported IR Source (USA) |
| Gas Flow Control | Micro-Pressure Differential Electronic Mass Flow Control |
| Catalytic Conversion | CuO Oxidation Furnace (optional), SO₂-to-SO₃ Conversion with SO₃ Trap |
| Software Platform | Windows 10/11 Native GUI with LIMS Integration Support |
| Compliance | Designed for ISO/IEC 17025-compliant labs |
| Brand | NCS |
|---|---|
| Origin | Beijing, China |
| Manufacturer | NCS Jiangsu Testing Technology Institute Co., Ltd. |
| Model | CS3500G |
| Measurement Principle | Infrared Absorption |
| Combustion Systems | High-Frequency Induction Furnace (18 MHz, 2.7 kVA) & Tube-Type Resistance Furnace (up to 1550 °C, max. 20 A) |
| Carbon Range | HF furnace — low C: 0.6 ppm–0.1 wt% |
| high C | 0.1–50 wt% |
| Sulfur Range | HF furnace — low S: 0.6 ppm–0.3 wt% |
| high S | 0.3–30 wt% |
| Resistance furnace — C | 0.01–100 wt%, S: 0.005–100 wt% |
| Sensitivity | 0.01 ppm |
| Precision | Low-C: ±1 ppm or RSD ≤1% |
| High-C | RSD ≤0.5% |
| Analysis Time | HF furnace — 30–40 s |
| Brand | NCS |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | CS4600 |
| Measurement Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Heating System | Vertical Tube Resistance Furnace (Max. 1500 °C, 1 °C Adjustable) |
| Carbon Range | 0.01–100 wt% |
| Sulfur Range | 0.005–100 wt% |
| Sensitivity | 0.1 ppm |
| Precision | C: RSD ≤ 0.5% |
| S | RSD ≤ 1.0% |
| Analysis Time | 60–180 s (user-configurable) |
| Sample Mass | 200–500 mg (coal, typical) |
| Power Supply | 220 VAC ±10%, 50 ±1 Hz, 20 A |
| Dimensions (L×W×H) | 814 × 710 × 1629 mm |
| Weight | ~170 kg |
| Brand | NCS |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | CS5500 |
| Measurement Principle | Infrared Absorption Spectroscopy |
| Heating System | High-Frequency Induction Furnace (13.56 MHz, 2.7 kVA, Adjustable Power) |
| Carbon Range | 0.6 ppm – 6.0% (0.0006–60 mg absolute, based on 1000 mg sample) |
| Sulfur Range | 0.6 ppm – 6.0% (0.0006–60 mg absolute, based on 1000 mg sample) |
| Sensitivity | 0.01 ppm |
| Precision | C: ±0.3 ppm or RSD ≤ 0.5% |
| S | ±0.3 ppm or RSD ≤ 0.5% |
| Analysis Time | Minimum 60 s per cycle |
| Sample Mass Recommendation | 0.1–0.5 g |
| Carrier Gas | Oxygen ≥99.5% purity |
| Assist Gas | Nitrogen or inert gas |
| Power Supply | 220 VAC ±10%, 50/60 Hz ±1 Hz, 16 A |
| Dimensions | 620 × 760 × 800 mm (W × D × H) |
| Weight | 107 kg |
| Brand | NCS |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | H5500 |
| Instrument Type | Oxygen-Nitrogen-Hydrogen Analyzer |
| Hydrogen Analysis Range | Low-H: 0.1–200 ppm |
| High-H | 200–5000 ppm |
| Hydrogen Precision | ±0.2 ppm or RSD ≤ 2.0% |
| Sensitivity | 0.01 ppm |
| Analysis Time | 3 min |
| Pulse Furnace | 0–1500 A, 8.5 kVA, Max Temp: 3500 °C |
| Carrier Gas | Ultra-High-Purity N₂ (≥99.9995%) |
| Dimensions | 63 × 76 × 76 cm (W×D×H) |
| Weight | ~180 kg |
| Brand | NCS |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer | NCS (National Center for Steel & Iron Research) |
| Instrument Type | Floor-standing |
| Excitation Method | Spark Discharge |
| Detector Type | Photomultiplier Tube (PMT) |
| Focal Length | 750 mm |
| Grating Line Density | 2400 lines/mm |
| Wavelength Range | 120–800 nm |
| Number of Analytical Channels | 48 |
| Dispersion | 0.55 nm/mm (1st order), 0.275 nm/mm (2nd order) |
| Optical Resolution | < 0.01 nm |
| Selectable Spectral Lines | 240 |
| Dimensions (W×D×H) | 139 cm × 80 cm × 117 cm |
| Weight | ~400 kg |
| Power Supply | 220 V ±10%, Single-phase, 10 A, 2.5 kVA |
| Brand | NCS (China Iron & Steel Research Institute Group – National Center for Steel Quality Inspection) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Pulse-heated Inert Gas Fusion Nitrogen Analyzer |
| Measurement Principle | Thermal Conductivity Detection (TCD) after High-Temperature Inert Gas Fusion |
| Analysis Range | Low-N: 0.1 ppm – 0.5% |
| High-N | 0.5% – 50% |
| Precision | ±1 ppm or RSD ≤ 1.0% |
| Sensitivity | 0.01 ppm |
| Analysis Time | ~3 min per sample |
| Furnace Power | 0–1500 A, 8.5 kVA, max. temperature 3500 °C |
| Sample Mass | Typically 1 g (adjustable per matrix and concentration) |
| Carrier Gas | Ultra-high-purity helium (≥99.9995%) |
| Dimensions | 63 cm (W) × 76 cm (D) × 76 cm (H) |
| Weight | ~180 kg |
| Brand | NCS |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | NX-200S |
| Pricing | Upon Request |
| X-ray Tube | 70 kV end-window micro-focus tube |
| Detector | Imported integrated Si-PIN detector, energy resolution ≤125 eV at 5.889 keV |
| Sample Form | Dry, homogenized powder (no digestion required) |
| Detection Limits (3σ, mg/kg) | Cd 0.16 |
| Battery Life | 8–10 h per charge (removable Li-ion) |
| Operating Temperature | −20 °C to +40 °C |
| Dimensions | 260 W × 350 L × 300 H mm |
| Weight | <4.5 kg |
| Compliance | GBZ 115–2002 (X-ray safety), GB 15618–2018 (Soil Risk Control Standard) |