| Brand | Hefei Kejing |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | InAs Crystal Substrate |
| Pricing | Available Upon Request |
| Crystal Structure | Cubic, Lattice Constant a = 5.4505 Å |
| Growth Method | Czochralski (CZ) |
| Conductivity Type | N-type |
| Doping | Undoped |
| Carrier Concentration | 2–5 × 10¹⁶ cm⁻³ |
| Electron Mobility | >18,500 cm²/V·s |
| Standard Orientations | <100>, <111> |
| Standard Dimensions | 10 × 10 × 0.5 mm, Ø2″ × 0.5 mm |
| Surface Finish | Single-side or double-side polished |
| Surface Roughness (Ra) | <0.15 nm |
| Cleanroom Packaging | Class 1000 cleanroom processed, sealed in Class 100 cleanroom bags |
| Brand | INESA |
|---|---|
| Origin | Shanghai, China |
| Instrument Type | Flame and Graphite Furnace Atomic Absorption Spectrophotometer |
| Compliance | Meets ISO 11171, ASTM D5185, USP <731>, and GB/T 21187–2007 for AAS methodology |
| Detection Limits | Sub-pptr range for most elements (e.g., Cd: 0.002 µg/L, Pb: 0.02 µg/L in flame mode |
| Cd | 0.1 pg, Pb: 0.5 pg in GF mode) |
| Wavelength Range | 190–900 nm |
| Spectral Bandwidth | 0.1, 0.2, 0.4, 1.0, 2.0 nm selectable |
| Light Source | Hollow Cathode Lamps (HCLs) and Electrodeless Discharge Lamps (EDLs) |
| Detector | High-sensitivity photomultiplier tube (PMT) |
| Data Output | USB 2.0, RS-232, optional Ethernet interface |
| Software | AAWinLab v3.2 with audit trail, user permission levels, and 21 CFR Part 11 compliance modules |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | 3000 Micro GC |
| Pricing | Available Upon Request |
| Brand | Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Beishide Instrument Co., Ltd. |
| Model | BSD-MASS |
| Mass Range | 1–100 amu (standard), optional up to 200 or 300 amu |
| Filament | Dual iridium-coated filaments (hot-swap via software) |
| Resolution | <0.5 ppm at 40 amu |
| Scan Speed | 1.8 ms/amu, step size 0.1 amu |
| Minimum Detectable Partial Pressure | 2 × 10⁻¹⁵ Torr (4 s dwell time) |
| Sample Flow Rate | 0.2–2 SCCM (micro-flow optimized) |
| Response Time | <1 s at ≤2 SCCM |
| Splitting System | High-precision electronic flow splitter |
| Ionization | Electron energy software-adjustable (soft ionization mode supported) |
| Turbomolecular Pump | Edwards nTX85, 85 L/s, 100,000 RPM, base pressure 1 × 10⁻¹² mbar |
| Dry Scroll Pump | 20 L/s, base pressure 1 × 10⁻¹ mbar |
| Chamber | Monolithic heated vacuum chamber (no welds), bake-out temperature 150 °C |
| Inlet | 1.2 m passivated stainless-steel capillary, condensation- and clog-resistant design |
| Software | INFICON Vacuum & Process Suite (English), TCP/IP communication |
| Dimensions | 510 mm (H) × 520 mm (L) × 225 mm (W), Weight: 30 kg |
| Brand | INFICON |
|---|---|
| Origin | USA |
| Model | Fusion |
| Instrument Type | Laboratory Micro Gas Chromatograph |
| Temperature Control Range | Ambient +5°C to 300°C |
| Maximum Ramp Rate | 300°C/min |
| Cooling Rate | 250°C to 50°C in <1 min |
| Carrier Gas Flow Range & Control | 3 mL/min |
| Carrier Gas Pressure Range & Control | 60 PSI |
| Injector Max Operating Temperature | 140°C |
| Injector Pressure Setting Range | 0–20 PSI |
| Injector Total Flow Setting Range | 0–10 mL/min |
| Brand | INFICON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | HAPSITE CDT |
| Instrument Type | Single Quadrupole Mass Spectrometer |
| GC-MS Configuration | Conventional Benchtop-Portable Hybrid GC/MS |
| Mass Range | 1–424 Da |
| Detection Limit | <1 ppb (for target analytes under optimized conditions) |
| Vacuum System | Non-Evaporable Getter (NEG) Pump |
| Battery Operation | Dual hot-swappable Li-ion batteries, >12 h continuous runtime |
| Sample Introduction | Membrane Valve Inlet with Auto-Recognition of Split/Splitless Modes |
| Analysis Time | <5 min per sample (typical) |
| Library | Configurable AMDIS-based spectral library with built-in CWAs, FGAs, TICs, TIMs, VOCs, SVOCs, explosives, and fentanyl analogues |
| Remote Sampling | Integrated TNEX adsorbent trap, 7-day sample stability, UAV-mountable design |
| Compliance | Designed to support GLP/GMP-aligned workflows |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Micro GC Fusion |
| Pricing | Available Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Transpector® RGA Series |
| Pricing | Available Upon Request |
| Brand | InFoMass |
|---|---|
| Origin | Beijing, China |
| Model | L10 |
| Cooling Options | Liquid Nitrogen (−189 °C) or Electronic (−90 °C) |
| Modulation Range | C₄–C₄₅ (LN₂ mode) |
| Column Configuration | Dual-column serial coupling via cryogenic loop modulator |
| Modulation Cycle | Programmable |
| Cold Jet Flow | Precisely controllable |
| Software Compatibility | MDCTM (GC Image LCC) |
| Structural Design | Fixed-angle column routing bracket eliminating manual alignment calibration |
| Moving Parts | None |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Pricing | Upon Request |
| Instrument Category | Spectral Software & Reference Database |
| Brand | INNOTEG |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | EasyNTC |
| Pricing | Available Upon Request |
| Brand | INNOTEG |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | EasyPrep Eco |
| Price | Upon Request |
| Application Level | Laboratory-Scale |
| Instrument Type | Medium-to-Low Pressure Preparative Liquid Chromatography System |
| Flow Rate Range | 0.1–150 mL/min |
| Maximum Operating Pressure | 1.0 MPa |
| UV-Vis Wavelength Selection | 254–800 nm (discrete wavelength options) |
| Brand | INNOTEG |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | EasyPrep HP |
| Instrument Type | High-Pressure Preparative Liquid Chromatograph |
| Solvent Delivery | Binary Gradient |
| Flow Rate Range | Up to 100 mL/min |
| Maximum Pressure | 3000 psi (20.7 MPa) |
| UV Detection Wavelength Options | 200–400 nm or 200–800 nm |
| Column ID Compatibility | 10–50 mm |
| Collection Modes | Full Fraction, Peak-Based, Time-Based |
| Dimensions (L×D×H) | 587 × 400 × 565 mm |
| Safety Features | Leak Detection, Over-Pressure Alarm |
| Software | Real-Time Gradient Editing, Drag-and-Drop Gradient Curve Adjustment, On-the-Fly Flow Rate Modification |
| Tube Rack Recognition | Supported |
| Regulatory Compliance Support | GLP-compliant audit trail logging (software-configurable), FDA 21 CFR Part 11 readiness (user authentication & electronic signature modules available) |
| Brand | INNOTEG |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Regional Category | Domestic (China-Made) |
| Model | INNOTEG EasyPrep MP |
| Instrument Type | Medium- to Low-Pressure Preparative Liquid Chromatography System |
| Flow Rate Range | 1–200 mL/min |
| Flow Accuracy | ≤ ±2% |
| Maximum Operating Pressure | 200 psi |
| UV Detection Wavelength Range | 200–400 nm |
| Baseline Noise | 1 × 10⁻⁴ AU (at 254 nm, water) |
| Brand | Innoteg |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-made) |
| Model | InnoFTIR10 |
| Instrument Type | Laboratory FTIR Spectrometer |
| Wavenumber Range | 7800–350 cm⁻¹ |
| Spectral Resolution | Better than 1.0 cm⁻¹ |
| Signal-to-Noise Ratio (S/N) | 45,000:1 (peak-to-peak, 2100 cm⁻¹, 4 cm⁻¹ resolution, 1-minute acquisition) |
| Beam Diameter | 10 mm |
| Beamsplitter | Imported multi-layer germanium-coated KBr, Ø60 mm with anti-humidity coating |
| Source | Imported high-intensity air-cooled ceramic IR source |
| Detector | Imported low-noise deuterated triglycine sulfate (DLATGS) detector |
| Interferometer | Oscillating-mirror interferometer (space-derived optical architecture) |
| Baseline Flatness | ≤0.1% T |
| Dimensions (W×D×H) | ≥590 × 355 × 185 mm |
| Sample Compartment Size (W×D×H) | ≥200 × 255 × 150 mm |
| Weight | 26 kg |
| Interface | USB |
| Power Supply | AC 220 V / DC 12 V, 40 W |
| Operating System | Windows 10 (64-bit or later) |
| Ambient Temperature | 15–28 °C |
| Relative Humidity | <65% RH (non-condensing) |
| Optional Features | N₂ purge port, built-in desiccant chamber with visual indicator, heater-assisted humidity control, adjustable interferometer energy output |
| Brand | Innoteg |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-made) |
| Model | InnoFTIR15 |
| Instrument Type | Laboratory FTIR Spectrometer |
| Wavenumber Range | 7800–350 cm⁻¹ |
| Spectral Resolution | <1.0 cm⁻¹ |
| Signal-to-Noise Ratio (S/N) | 30,000:1 (peak-to-peak, 2100 cm⁻¹, 4 cm⁻¹ resolution, 60 s acquisition) |
| Beam Diameter | 15 mm |
| Beamsplitter | Multi-layer Ge-coated KBr (imported) |
| Source | High-intensity air-cooled ceramic IR source (imported) |
| Interferometer | Michelson-type, self-compensating, automated alignment |
| Detector | Low-noise deuterated triglycine sulfate (DLATGS) detector (imported) |
| Baseline Flatness | ≤0.1% T |
| Measurement Modes | Transmittance, Absorbance, Radiant Energy |
| Dimensions (W×D×H) | 486 × 406 × 230 mm |
| Sample Compartment Size | 200 × 170 × 145 mm |
| Weight | 23 kg |
| Interface | USB 2.0 |
| Power Supply | AC 220 V / DC 12 V, 40 W |
| OS Compatibility | Windows 10 (64-bit or later) |
| Operating Environment | 15–28 °C, RH <65% (non-condensing) |
| Brand | Innoteg |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | InnoFTIR15C |
| Instrument Type | Laboratory FTIR Spectrometer |
| Wavenumber Range | 4000–400 cm⁻¹ |
| Signal-to-Noise Ratio (S/N) | 15,000:1 (at 4 cm⁻¹ resolution, 1 min scan) |
| Wavenumber Accuracy | ±0.01 cm⁻¹ |
| Optical System | Michelson Interferometer with KBr Multilayer Beam Splitter (Ge-coated, anti-humidity) |
| Detector | High-Sensitivity DLATGS |
| Source | High-Intensity Air-Cooled Ceramic IR Source |
| Enclosure | Electromagnetically Shielded Metal Housing |
| Included Accessory | Integrated Desiccant Dry Box |
| Software | Building Glass Compliance Suite (GB/T 2680–2021, JGJ/T 151–2008 compliant) |
| Spectral Range | 190–3200 nm |
|---|---|
| Bandwidth (UV-VIS) | 0.2, 0.5, 1, 2, 3, 5 nm |
| Bandwidth (NIR) | 0.8, 2, 4, 8, 12, 20 nm |
| Wavelength Accuracy | ±0.5 nm (UV/VIS), ±2.0 nm (NIR) |
| Wavelength Repeatability | ≤0.3 nm (UV/VIS), ≤1.0 nm (NIR) |
| Brand | INNOTEG |
|---|---|
| Origin | China |
| Manufacturer Type | Manufacturer |
| Model | IUS-190 |
| Spectral Range | 190–3200 nm |
| Bandwidth (UV-VIS) | 0.2, 0.5, 1, 2, 3, 5 nm |
| Bandwidth (NIR) | 0.8, 2, 4, 8, 12, 20 nm |
| Wavelength Accuracy | ±0.5 nm (UV/VIS), ±2.0 nm (NIR) |
| Wavelength Repeatability | ≤0.3 nm (UV/VIS), ≤1.0 nm (NIR) |
| Brand | INNOTEG |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | IUS-200-10 |
| Spectral Range | 280–2500 nm |
| Slit Bandwidth | UV-VIS: 0.2, 0.5, 1, 2, 3, 5 nm |
| NIR | 0.8, 2, 4, 8, 12, 20 nm |
| Wavelength Accuracy | ±0.5 nm (UV/VIS), ±2.0 nm (NIR) |
| Wavelength Repeatability | ≤0.3 nm (UV/VIS), ≤1.0 nm (NIR) |
| Brand | INNOTEG |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | IUS-200-15 |
| Spectral Range | 280–2500 nm |
| Slit Bandwidth | UV-VIS: 0.2, 0.5, 1, 2, 3, 5 nm |
| NIR | 0.8, 2, 4, 8, 12, 20 nm |
| Wavelength Accuracy | ±0.5 nm (UV/VIS), ±2.0 nm (NIR) |
| Wavelength Repeatability | ≤0.3 nm (UV/VIS), ≤1.0 nm (NIR) |
| Integrating Sphere Diameter | 150 mm |
| Optical Design | Dual-beam, dual-grating, dual-detector architecture |
| Detector Configuration | Separate optimized detectors for UV/VIS and NIR ranges |
| Software Compatibility | Windows 7/10 |
| Data Export Formats | TXT, CSV, XLSX |
| Compliance Standards | GB/T 2680-2021, JGJ/T 151-2008, ISO 9050:2003, GB/T 22476-2008, GB/T 36261-2018, GB/T 25261-2010, JG/T 235-2014, JGJ/T 287-2014, GJB 798-90, GJB 2502.2-2006 |
| Brand | INNOTEG |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | IUS-200-6 |
| Spectral Range | 280–2500 nm |
| Slit Bandwidth | [UV-VIS] 0.2, 0.5, 1, 2, 3, 5 nm |
| Wavelength Accuracy | ±0.5 nm (UV/VIS), ±2.0 nm (NIR) |
| Wavelength Repeatability | ≤0.3 nm (UV/VIS), ≤1.0 nm (NIR) |
| Brand | INNOTEG |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | T2110 |
| Temperature Range | Ambient to 400 °C |
| Gas Flow Rate | 0–200 mL/min |
| Tube Capacity | 10 tubes |
| Brand | Innov-X |
|---|---|
| Origin | USA |
| Model | DELTA Series |
| Portability | Handheld |
| Elemental Range | Mg to U |
| Detection Limit | 1 ppm |
| Quantification Range | 1 ppm – 99.99% |
| Energy Resolution | <165 eV |
| Repeatability | ≥95% |
| Excitation Source | Micro-focus X-ray Tube (10–40 kV) |
| Detector | High-Performance Silicon Drift Detector (SDD) |
| Weight | <1.5 kg |
| Operating System | Microsoft Windows Embedded CE |
| Battery Life | >4 hours continuous operation |
| Hot-Swap Battery Support | Yes |
| Display | 32-bit color touchscreen |
| Sample Targeting | Integrated camera + collimated beam optics |
| Trigger Options | Mechanical trigger, Deadman safety trigger, or external PC control |
| Brand | Innov-X |
|---|---|
| Origin | USA |
| Model | XDD-5000 Series |
| Elemental Range | Mg to U |
| Detection Limit | 1 ppm – 99.99% |
| Energy Resolution | <165 eV |
| Repeatability | 95% |
| Weight | <12 kg |
| Excitation Source | 10 W Microfocus X-ray Tube |
| Detector | High-Performance Silicon Drift Detector (SDD) |
| Operating System | Windows XP |
| Configuration | Benchtop or Floor-Standing |
| Distribution Type | Imported Instrument via Authorized Distributor |
| Brand | INNUO |
|---|---|
| Origin | Shanghai, China |
| Model | SYTP-1 |
| Operating Frequency | 10 MHz |
| Mass Sensitivity | 2.26 × 10⁸ Hz/(g/cm²) |
| Mass Detection Range | 4.42 × 10⁻⁹ g/cm² to 4.42 × 10⁻⁴ g/cm² |
| Temperature Control Range | −196 °C to +70 °C |
| Vacuum Compatibility | Down to 1 × 10⁻⁵ Pa |
| Temperature Stability | ±0.1 °C |
| Frequency Resolution | ±1 Hz |
| Power Input | 100–240 VAC, 50/60 Hz |
| Interface Options | USB 2.0, Ethernet (RJ45), USB Flash Drive Data Export |
| Brand | INNYAO |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | IC-100 |
| Instrument Type | Discrete Flow Analyzer |
| Wavelength Range | 340–880 nm |
| Sample Capacity | 200 positions (standard carousel) / 100 positions (optional dual-rack configuration) |
| Reagent Positions | 4 |
| Cuvette Path Length | 10 mm |
| Light Source | Single-beam halogen lamp (6 V / 10 W) |
| Optical System | Fixed-wavelength photometric detection with selectable filters |
| Brand | Hefei Kejing |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | InP Crystal Substrate |
| Pricing | Available Upon Request |
| Crystal Structure | Single-Crystal Indium Phosphide |
| Doping | Undoped / Sn / S / Fe / Zn |
| Conductivity Type | N-type (Sn, S, Fe) / Semi-Insulating (Fe, Zn) / P-type (Zn) |
| Hardness | 3.0 Mohs |
| Density | 4.78 g/cm³ |
| Refractive Index | 3.45 (at 10.6 µm) |
| Carrier Concentration | 1–2×10¹⁶ cm⁻³ (undoped), 1–3×10¹⁸ cm⁻³ (Sn-doped), 1–4×10¹⁸ cm⁻³ (S-doped), 6–4×10¹⁸ cm⁻³ (Fe-doped) |
| Dislocation Density | <5×10⁴ cm⁻² |
| Growth Method | Liquid Encapsulated Czochralski (LEC) |
| Melting Point | 1072 °C |
| Elastic Modulus | 7.1×10¹¹ dyn·cm⁻² |
| Standard Orientations | <100> |
| Standard Dimensions | 10 mm × 10 mm × 0.5 mm |
| Surface Finish | Single-Side or Double-Side Polished |
| Surface Roughness (Ra) | <15 Å |
| Cleanroom Handling | Packaged in Class 100 cleanroom bags within Class 1000 cleanroom environment |
| Brand | INSA Optics |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Laboratory FTIR Spectrometer |
| Spectral Range | 8000–350 cm⁻¹ (extendable to 12800–4000 cm⁻¹ in NIR |
| Spectral Resolution | 0.2 cm⁻¹ |
| Scan Speed | 2.5–60 kHz |
| Signal-to-Noise Ratio (SNR) | 40,000:1 (at 4 cm⁻¹, 1 min scan, MCT detector) |
| Wavenumber Accuracy | < ±0.1 cm⁻¹ |
| Vacuum Level | ≤ 0.2 mbar |
| Optical Design | All-metal vacuum-sealed cast-aluminum interferometer housing with independent optical chamber |
| Brand | Hefei Kejing |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | InSb Crystal Substrate |
| Pricing | Upon Request |
| Doping | None / Te / Ge |
| Conductivity Type | N / N / P |
| Carrier Concentration | 1–5 × 10¹⁴ cm⁻³ / 1–2 × 10¹⁵ cm⁻³ |
| Dislocation Density | < 2 × 10² cm⁻² |
| Standard Dimensions | 2″ (50.8 mm) diameter × 0.5 mm thickness |
| Surface Roughness (Ra) | < 15 Å |
| Packaging | Class 1000 cleanroom processed |