| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Type | Portable Gas Chromatograph |
| Application Scope | General-purpose Environmental Emission Monitoring |
| Compliance Standards | HJ 1012, HJ 38, HJ 604, GB 37822–2019 |
| Detection Principle | High-Temperature Heated Sample Transfer + Flame Ionization Detection (FID) |
| Detection Limit | Sub-ppb Level for Total Hydrocarbons, Methane, and BTEX |
| Integrated Power Supply | Rechargeable Lithium Battery (≥4 h continuous operation with heated line) |
| Data Output | Raw Chromatograms & Quantitative Results Exportable in Standard Formats (e.g., .csv, .cdf) |
| Certification | China Metrology Accreditation (CPA), Compatible with CMA Reporting Requirements |
| Sample Introduction | Dual-Stage Filtered Sampling Pump + Fixed-Volume Loop Injection |
| Column Configuration | Capillary GC Column Optimized for C1–C8 Hydrocarbons |
| Detector Temperature | Up to 180 °C |
| Sample Line Temperature | Heated to 180 °C |
| Dimensions & Portability | Integrated All-in-One Chassis with Carrying Handle |
| Optional Accessories | Android Tablet Interface, High-Pressure Gas Cylinders, Metal Hydride Hydrogen Generators |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Category | Domestic Lab-Scale Gas Chromatograph |
| Model | GC-2000 Universal |
| Application Scope | General-Purpose Analytical Chemistry |
| Control Interface | Full-Touch Color LCD Display |
| Pneumatic Control | Electronic Pressure and Flow Control (EPC) |
| Software Architecture | Modular Workstation with Method-Driven Workflow |
| Microfluidic Capability | Valveless Flow Switching for Column Back-Flush, Detector Selection, and GC-MS Parallel Operation |
| Compliance Context | Designed for GLP/GMP-aligned laboratories |
| Brand | Fuli |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | F60 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-purpose |
| Detector Options | FID, FPD |
| Control Interface | 7-inch TFT capacitive touchscreen |
| Gas Control | Mechanical valves with electronic pressure & flow monitoring |
| Column Oven | Dual-sensor temperature monitoring, thermal fuse protection, flame-retardant materials (UL94 V-0 rated) |
| Compliance | Designed to support GLP/GMP workflows, ASTM D3606/D1319, ISO 17025-aligned operation |
| Brand | Fuli |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | F70 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose Analysis |
| Control Architecture | Dual-AFC (Carrier Gas & Detector Auxiliary Gas) or Full-AFC Mode |
| Detection Systems | FID, FPD (Wide-Range Configurable) |
| Injection Options | Multiple Configurable Inlet Types |
| Software Platforms | FL97Plus, MyLab Chromatography Data Systems (CDS) |
| Compliance Framework | Designed for GLP/GMP-aligned workflows with audit trail-ready CDS options |
| Human-Machine Interface | 7-inch capacitive touchscreen with real-time multi-channel status visualization |
| Maintenance Intelligence | Consumables tracking (septa, liner, split cold trap), usage-based alerts, and automated leak-check protocol |
| Brand | Fuli |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | F70 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | 6 °C to 400 °C |
| Maximum Ramp Rate | 120 °C/min |
| Cooling Rate | <7.0 min from 350 °C to 50 °C |
| Carrier Gas Flow Range & Control | 0–450 mL/min |
| Carrier Gas Pressure Range & Control | 0–100 psi |
| Electronic Pressure Control (EPC), pressure setting resolution | 0.01 psi |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–100 psi |
| Injector Total Flow Setting Range | 0–450 mL/min |
| Brand | Fuli |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Class | Ultra-High-Performance Liquid Chromatograph (UHPLC) |
| Application Scope | General-Purpose LC Analysis |
| Model | L75 |
| Pricing | Upon Request |
| Brand | Fuli |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Category | Domestic |
| Model | LC5090Plus |
| Pricing | Upon Request |
| Instrument Type | Ultra-High Performance Liquid Chromatograph (UHPLC) |
| Application Scope | General-Purpose Analytical Use |
| Brand | Fuli |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | LC5190 |
| Instrument Type | Conventional High-Performance Liquid Chromatograph (HPLC) |
| Application Scope | General-Purpose Analytical Instrument |
| Flow Rate Accuracy | ≤0.1% RSD |
| Pressure Range | Up to 60 MPa |
| Wavelength Range (UV Detector) | 190–900 nm |
| Injection Volume Precision | ±0.1 µL |
| Column Temperature Control Range | 5–85 °C (with cooling & heating) |
| Detection Modes Supported | UV-Vis, DAD, FL, ELSD, RI |
| Brand | Fulit |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | F60 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Temperature Control Range | 6°C to 400°C |
| Maximum Ramp Rate | 120°C/min |
| Cooling Time | <7.0 min (from 350°C to 50°C) |
| Carrier Gas Flow Control | Electronic Flow Display |
| Carrier Gas Pressure Control | Electronic Pressure Display |
| Injector Maximum Operating Temperature | 400°C |
| Brand | Fulit |
|---|---|
| Origin | Zhejiang, China |
| Model | F70pro |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-purpose |
| Oven Temperature Range | 6 °C to 400 °C |
| Maximum Ramp Rate | 120 °C/min |
| Cooling Rate | <3.0 min from 200 °C to 100 °C |
| Carrier Gas Flow Range & Control | 0–450 mL/min with Electronic Pressure Control (EPC) for carrier gas and Automatic Flow Control (AFC) for auxiliary gases |
| Carrier Gas Pressure Range & Control | 0–100 psi with EPC |
| pressure control resolution | 0.001 psi |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–100 psi |
| Injector Total Flow Setting Range | 0–450 mL/min |
| Brand | Fulit |
|---|---|
| Origin | Zhejiang, China |
| Model | F80 |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Application Scope | General-Purpose GC Analysis |
| Oven Temperature Range | 4 °C to 450 °C |
| Maximum Ramp Rate | 250 °C/min |
| Cooling Rate | <5.0 min from 450 °C to 50 °C |
| Carrier Gas Flow Range & Control | 0–1250 mL/min (H₂ or He), 0–500 mL/min (N₂) |
| Carrier Gas Pressure Range & Control | 0–100 psi (standard), optional 0–150 psi |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–100 psi (standard), optional 0–150 psi |
| Injector Total Flow Setting Range | 0–1250 mL/min (H₂/He), 0–500 mL/min (N₂) |
| Control System | Integrated high-resolution touchscreen interface with embedded real-time GC control firmware |
| Brand | Huazhun Chromatography |
|---|---|
| Model | GC-2021plus |
| Origin | Jiangxi, China |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-purpose |
| Oven Temperature Range | 5 °C to 450 °C |
| Maximum Ramp Rate | 250 °C/min |
| Cooling Rate | ≤8 min (from 350 °C to 50 °C at 25 °C ambient) |
| Carrier Gas Flow Control Range | 0–200 mL/min (N₂), 0–1250 mL/min (H₂ or He) |
| Carrier Gas Pressure Control Range | 0–1035 kPa (0–150 psi) |
| Injector Maximum Operating Temperature | 420 °C |
| Brand | GBC |
|---|---|
| Origin | Australia |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LC 3000 |
| Pricing | Upon Request |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | GC-4008B |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Application Domain | Coal Mining Safety & Spontaneous Combustion Monitoring |
| Detection Systems | TCD, Dual FID, ECD, FPD |
| Column Configuration | Four Dedicated Capillary/Packed Columns |
| Temperature Program | 10-Stage Programmable Ramp |
| Carrier Gases | Helium (TCD), Hydrogen/Air (FID), Nitrogen (ECD/FPD) |
| Minimum Detectable Concentrations | CO, C₂H₂ ≤ 0.5 ppm |
| [Brand | Lunan Ruihong |
|---|---|
| Origin | Shandong, China |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | 4 °C to 450 °C |
| Ramp Rate | 0.1–80 °C/min |
| Cool-down Rate | ≤3 min (200 °C → 100 °C) |
| Carrier Gas Flow Control Range | 0–1000 mL/min |
| Carrier Gas Pressure Control Range | 0–100 psi |
| Injector Max Temp | 450 °C |
| Injector Pressure Setpoint Range | 0–100 psi |
| Temperature Zones | 8 independent zones |
| Programmed Temperature Steps | up to 16 ramps |
| Detector Options | FID, TCD, ECD, FPD, NPD (up to 3 simultaneously)] |
| Brand | LABORAT |
|---|---|
| Model | LYG-1020 |
| Origin | Hebei, China |
| Instrument Type | High-Temperature GPC System |
| UV Detector Wavelength Range | 190–700 nm |
| Flow Rate (Standard) | 0.01–50.00 mL/min |
| Flow Rate (Optional High-Precision) | 0.001–10.000 mL/min |
| Auto-Sampler Volume (Standard) | 10 mL loop |
| Column Dimensions (Standard) | 25 × 400 mm |
| Fraction Collector | 5-position valve-based system (customizable) |
| Detection Light Source | Deuterium/Tungsten dual-lamp assembly |
| Software | Integrated industrial PC with audit-trail-enabled chromatography control software |
| Brand | GERSTEL |
|---|---|
| Origin | Germany |
| Model | MCS |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Domain | Petrochemical Industry |
| Modular Architecture | Fully Compatible with Agilent GC Platforms |
| Integrated Cryogenic Trapping | Yes |
| EPC-Controlled Column Switching & Flow Management | Yes |
| Software Control | MAESTRO v2.5+ (FDA 21 CFR Part 11 Compliant) |
| Regulatory Compliance | ASTM D6729, ISO 15503, USP <467>, GLP/GMP-Auditable Audit Trail |
| Sample Introduction Compatibility | CIS-4, MPS XT, TDS3, ODP, PFC |
| Brand | HAMILTON |
|---|---|
| Stationary Phase | PSDVB/Trimethylammonium |
| Mode | Anion Exchange |
| Particle Size | 10 µm |
| Pore Size | 100 Å |
| Inner Diameter | 4.1 mm |
| Length | 250 mm |
| Housing Material | Stainless Steel |
| Max. Pressure | 5,000 psi |
| Exchange Capacity | 0.304 meq/column |
| pH Stability Range | 1–13 |
| Mobile Phase Compatibility | 0–100% aqueous/organic (e.g., methanol, acetonitrile) |
| Temperature Limit | 60 °C (at pH 1–7), 50 °C (at pH 8–13) |
| Regeneration Protocol | 50 mL methanol + 1% v/v 6 N HNO₃ |
| Brand | Hanbon |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | NS8030A |
| Instrument Type | Preparative |
| Detector Type | UV |
| Maximum System Pressure | 20 MPa |
| Flow Rate Range | 0–300 mL/min |
| CO₂ Recovery System | Integrated |
| Collection Technology | Patented Cyclonic Collector |
| Brand | Hitachi |
|---|---|
| Origin | Japan |
| Manufacturer | Hitachi High-Tech Corporation |
| Instrument Type | Post-Column Derivatization Amino Acid Analyzer |
| Model | LA8080 |
| Pump Flow Rate | 0.000–1.000 mL/min |
| Maximum Pump Pressure | 34 MPa |
| Autosampler Injection Volume | 0–100 µL |
| Autosampler Temperature Control | 4 °C and 10 °C |
| Post-Column Reactor Temperature Range | 50–140 °C |
| Detection Wavelengths | 570 nm and 440 nm |
| Flow Cell Volume | 8 µL |
| Brand | HiTech |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | HT-1010 |
| Instrument Type | Post-Column Derivatization System |
| Pump Flow Rate | 0.000–9.999 mL/min |
| Maximum Pump Pressure | 40 MPa |
| Autosampler Injection Volume | 0–100 µL |
| Autosampler Temperature Control | 4–25 °C (optional) |
| Post-Column Reactor Temperature Range | Ambient to 150 °C |
| Detection Wavelengths | 570 nm and 440 nm |
| Flow Cell Volume | 8 µL |
| Brand | HMC |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | L-3000 |
| Instrument Type | Post-Column Derivatization System |
| Pump Flow Rate | 0.001–10.000 mL/min |
| Maximum Pump Pressure | 6000 psi |
| Autosampler Injection Volume | 1–500 µL |
| Autosampler Temperature Control | +5 °C (±1 °C) to 70 °C |
| Post-Column Reactor Temperature Range | Ambient to 150 °C |
| Detector Wavelength Range | 190–800 nm |
| Flow Cell Volume | 8 µL |
| Brand | HMC |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | L-3000plus |
| Instrument Type | Post-Column Derivatization System |
| Pump Flow Rate | 0.01–9.99 mL/min |
| Maximum Pump Pressure | 6000 psi (41.4 MPa) |
| Autosampler Injection Volume | 1–500 µL |
| Autosampler Temperature Control | +5 °C (±1 °C) to 70 °C |
| Post-Column Reactor Temperature Range | Ambient to 150 °C |
| Detection Wavelength Range | 190–800 nm |
| Flow Cell Volume | 8 µL |
| Brand | HMC |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (PRC) |
| Model | L-3000pro |
| Instrument Type | Post-Column Derivatization System |
| Pump Flow Rate | 0.001–10.000 mL/min |
| Maximum Pump Pressure | 6000 psi |
| Autosampler Injection Volume | 1–500 µL |
| Post-Column Reactor Temperature Range | Ambient to 150 °C |
| Detection Wavelength Range | 190–800 nm |
| Flow Cell Volume | 4 µL |
| Brand | HuaiAi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Origin | Domestic (China) |
| Model | GC-9560-HT |
| Price Range | USD 7,000 – 14,000 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | Ambient +8°C to 399°C |
| Maximum Ramp Rate | 40°C/min |
| Cooling Rate | 350°C → 50°C in <5 min |
| Carrier Gas Flow Range & Control | 0–500 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.4 MPa |
| Injector Maximum Operating Temperature | 399°C |
| Injector Pressure Setting Range | 0–0.4 MPa |
| Injector Total Flow Setting Range | 0–500 mL/min |
| Brand | HuaiAi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Origin | Domestic (China) |
| Model | GC-9760B |
| Price Range | USD 42,000 – 70,000 |
| Analysis Cycle | <20 min |
| Measurement Error | <3% |
| Thermal Stabilization Time | <30 min |
| Operating Ambient Temperature | −10 °C to +50 °C |
| Oven Temperature Range | 8 °C above ambient to 399 °C |
| Oven Temperature Accuracy | ±0.1 °C |
| Detector Temperature Range | 8 °C above ambient to 399 °C |
| Detector Temperature Accuracy | ±0.1 °C |
| Dimensions | 380 × 450 × 180 mm |
| Weight | <15 kg |
| Power Supply | 220 V ± 22 V, 50 Hz |
| Max. Power Consumption | ≤2 kW |
| Brand | HUANKONG |
|---|---|
| Model | PB-350 |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Detection Limit | <1 ppb (for target VOCs) |
| Repeatability | Compliant with ISO 8573-1 and ASTM D6420 standard requirements |
| Weight | ≤3.5 kg |
| Dimensions | 305 × 160 × 127 mm |
| Interface | USB 2.0, Ethernet, Bluetooth 5.0 |
| Power Supply | Internal Li-ion battery (≥8 h continuous operation), 12 V DC input |
| Brand | Elite |
|---|---|
| Particle Size | 5 µm |
| Dimensions | 4.6 mm × 250 mm |
| Stationary Phase | Hypersil GOLD C18 |
| Carbon Load | 10% |
| Pore Size | 175 Å |
| Silica Type | High-Purity Deactivated Silica |
| Endcapped | Yes |
| pH Stability Range (tested) | 1.8–10.6 |
| Aqueous Mobile Phase Compatibility | Stable in 100% aqueous conditions |
| Brand | 1124123/13213112 |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Laboratory Benchtop System |
| Application Scope | General-Purpose Ion Analysis |
| Maximum Operating Pressure | 42 MPa |
| Fluidic Path Material | Full-PEEK & PTFE/PEEK/PP Non-Metallic Construction |
| Pump Configuration | Integrated Quaternary Gradient Pump with Electrolytic Eluent Generation |
| Detector Options | Conductivity, Pulsed Amperometric (PAD), UV-Vis, Fluorescence |
| Compliance Support | ASTM D4327, ISO 10304-1/-3, USP <645>, EPA Methods 300.0/317.0/321.8 |
| Brand | InFoMass |
|---|---|
| Origin | Beijing, China |
| Model | L10 |
| Cooling Options | Liquid Nitrogen (−189 °C) or Electronic (−90 °C) |
| Modulation Range | C₄–C₄₅ (LN₂ mode) |
| Column Configuration | Dual-column serial coupling via cryogenic loop modulator |
| Modulation Cycle | Programmable |
| Cold Jet Flow | Precisely controllable |
| Software Compatibility | MDCTM (GC Image LCC) |
| Structural Design | Fixed-angle column routing bracket eliminating manual alignment calibration |
| Moving Parts | None |