Chromatography Instruments
Filter
Showing 211–240 of 1564 results
| Brand | Beifen Ruili |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Regional Category | Domestic (PRC) |
| Model | MAS-100 |
| Pricing | Upon Request |
| Brand | Beifen Ruili |
|---|---|
| Origin | Beijing, China |
| Model | MAS-100 |
| Detection Principle | Purge-and-Trap GC-Cold Vapor Atomic Fluorescence Detection (GC-AFD) |
| Compliance | HJ 977–2018 |
| Detector Type | Integrated Miniaturized Cold Vapor Atomic Fluorescence Detector (AFD) |
| Column Compatibility | Capillary GC columns |
| Auxiliary Detectors Supported | FID, ECD, TCD, FPD, TSD |
| Mercury Speciation | Methylmercury, Ethylmercury |
| Sample Matrix | Aqueous solutions |
| Derivatization Reagent | Sodium Tetrapropylborate (NaBPr₄) |
| Trapping Medium | Tenax® sorbent tube |
| Carrier Gas | Argon |
| Post-Detector Mercury Capture | Gold-coated Wire Trap with Active Vacuum Pump |
| Optical Design | Multi-stage stray-light suppression fluorescence cell |
| High-Temperature Module | 950 °C pyrolysis with nano-scale thermal insulation |
| Footprint | <120 mm × 100 mm × 80 mm (AFD unit only) |
| Brand | Beifen Ruili |
|---|---|
| Origin | Beijing, China |
| Model | SP-2110 |
| Instrument Type | Dedicated Gas Chromatograph for Dissolved Gas Analysis (DGA) in Transformer Oil |
| Compliance | Designed to meet GB/T 17623–2017, DL/T 703–2015, and IEC 60567 requirements |
| Interface | USB 2.0 |
| Data Acquisition | Integrated with Transformer Oil DGA-Specific Chromatography Workstation |
| Injection System | Manual syringe injection with micro-switch trigger activation |
| Gas Control | Equipped with digital pressure and mass flow sensors for carrier gas (N₂, H₂, or Ar) and detector gases |
| Detector Configuration | Dual-TCD (Thermal Conductivity Detector) or TCD+FID (optional) |
| Column | Pre-packed stainless-steel capillary or packed column optimized for C₁–C₅ hydrocarbons and CO/CO₂ separation |
| Brand | Beifen Ruili |
|---|---|
| Origin | Beijing, China |
| Model | SP-2120 |
| Temperature Control Range | 20–400 °C above ambient |
| Ramp Rate | 0.5–35 °C/min |
| Cool-down Time | <5 min (250 °C → 50 °C) |
| Carrier Gas Pressure Range & Control | 0–0.8 MPa |
| Injector Max Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–0.8 MPa |
| Detection Limits | H₂ ≤5 ppm, CO ≤0.5 ppm, O₂/N₂ ≤0.05 vol%, CH₄/CO₂/C₂H₄/C₂H₆/C₂H₂ ≤0.1 ppm |
| Total Analysis Time | ≤7 min (single injection, 9-component full profile) |
| Simultaneous Active Detectors | 3 (TCD + dual FID) |
| Flow Sensors | 4-channel digital gas flow monitoring |
| Valve Configuration | High-reliability imported 10-port rotary valve |
| Explosion Risk Assessment | Real-time calculation per GB/T 20964–2007 and AQ 1018–2006 |
| Compliance | Designed for GLP-compliant coal mine safety labs |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | SP-3420 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Focus | Pharmaceutical Analysis |
| Oven Temperature Range | Ambient +20°C to 400°C |
| Ramp Rate | 0.1–50°C/min |
| Cool-down Time | ~6 min (450°C → 50°C) |
| Carrier Gas Flow Control Range | 0–1200 mL/min |
| Carrier Gas Pressure Control Range | 0–970 kPa |
| Injector Max Operating Temperature | 450°C |
| Injector Pressure Setpoint Range | 0–970 kPa |
| Injector Total Flow Setpoint Range | 0–1200 mL/min |
| Column Oven Programmable Steps | 4×4 ramp/hold |
| Temperature Stability | ±0.1°C |
| Detector Options | TCD, FID, ECD, FPD, TSD |
| Injector Options | Packed Column, Split/Splitless Capillary |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Power Consumption | 1650 W |
| Net Weight | 50 kg |
| Dimensions (H×W×D) | 500 × 588 × 550 mm³ |
| Brand | Beifen Ruili |
|---|---|
| Origin | Beijing, China |
| Model | SP-3420A |
| Temperature Control Range | Ambient +12 °C to 400 °C |
| Maximum Oven Ramp Rate | >35 °C/min (100 °C to 200 °C in <3 min) |
| Injector Maximum Temperature | 400 °C |
| Injector Pressure Setting Range | 0–0.6 MPa |
| Compatible Detectors | TCD, FID, ECD, FPD, TSD |
| Injection Systems | Packed Column Injector, Split/Splitless Capillary Injector |
| Method Storage Capacity | 4 pre-programmed methods |
| Diagnostic Capability | Real-time self-diagnostic with fault localization |
| Safety Protections | TCD carrier-gas failure protection, overtemperature shutdown, FPD light-leak detection |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | SP-3420A |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | Ambient to 450 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Oven Cooling Rate | 450 °C to 50 °C in ≤8 min |
| Carrier Gas Flow Range & Control | 0–1200 mL/min (electronic pressure/flow control) |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Detector Options | TCD, FID, ECD, FPD, TSD |
| Injector Types | Packed Column Injector, Split/Splitless Capillary Injector |
| Control Interface | Microprocessor-based, full-keyboard operation with 32-digit LED display |
| Diagnostic Capability | Real-time self-diagnostic system with fault localization and remediation guidance |
| Method Storage | Up to 4 pre-programmed analytical methods |
| Safety Protections | TCD carrier gas failure protection, overtemperature cutoff, FPD light leakage detection |
| Valve Switching | Automated valve sequencing with dual signal switching capability |
| Brand | Beifen Ruili |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | SP-3500 |
| Price Range | USD 14,000–21,000 (FOB) |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | 5°C above ambient to 450°C |
| Maximum Ramp Rate | 50°C/min |
| Carrier Gas Flow Control | 0–1000 mL/min (H₂) |
| Carrier Gas Pressure Control | 0–100 psi |
| Injector Maximum Operating Temperature | 400°C |
| Injector Pressure Setting Range | 0–100 psi |
| Injector Total Flow Setting Range | 0–1000 mL/min (H₂) |
| Brand | Beifen Ruili |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (PRC) |
| Model | SP-3510 |
| Price Range | USD 14,000–21,000 (FOB Beijing) |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | 5 °C above ambient to 450 °C |
| Maximum Ramp Rate | 50 °C/min |
| Cooling Capability | Forced-air cooling (no cryogenic option) |
| Carrier Gas Flow Control Range | 0–1000 mL/min (H₂) |
| Carrier Gas Pressure Control Range | 0–100 psi |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–150 psi |
| Injector Total Flow Setting Range | 0–1000 mL/min (H₂) |
| Heating Zones | 9 independent temperature-controlled zones |
| Simultaneous Inlets/Detectors | Up to 3 inlets and 3 detectors operational concurrently |
| Detector Options | FID, TCD, ECD, FPD, TSD, AFD |
| Brand | Beifen Ruili |
|---|---|
| Origin | Beijing, China |
| Model | SP-5220 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Regulatory Compliance | CE-marked per EN 61010-1, IEC 61326-1 (EMC), ISO/IEC 17025-compatible operation |
| Control System | Linux-based embedded platform with Ethernet and USB 2.0 interfaces |
| Pressure Control Accuracy | ±0.001 psi (EPC) |
| Temperature Program Reproducibility | ±0.5% (RSD) |
| MTBF | >12,000 hours |
| Safety Certification | UL 61010-1 / GB 4793.1 compliant |
| Electromagnetic Compatibility | Tested to IEC 61326-1 Class A |
| Brand | Beifen Ruili |
|---|---|
| Origin | Beijing, China |
| Model | SP3400 |
| Temperature Control Range | Ambient +12 °C to 420 °C |
| Maximum Oven Ramp Rate | >33 °C/min (100 °C to 200 °C in <3 min) |
| Injector Max Operating Temperature | 420 °C |
| Injector Pressure Setting Range | 0–0.6 MPa |
| Detector Options | TCD, FID, ECD, FPD, TSD |
| Injector Types | Packed Column Injector, Split/Splitless Capillary Injector |
| Method Storage Capacity | 4 methods |
| Compliance | Designed to meet ISO/IEC 17025 operational prerequisites for routine GC analysis |
| Brand | Beifen Ruili |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (PRC) |
| Model | SY-9100 |
| Price Range | USD 14,000–28,000 |
| Instrument Type | Conventional HPLC System |
| Application Scope | General-purpose analytical use |
| Flow Rate Range | 0.001–9.999 mL/min (0.001 mL/min increment) |
| Maximum Operating Pressure | 42 MPa |
| Flow Precision | <0.1% RSD |
| Sample Tray Capacity | 96 positions (1.5 mL vials) |
| Injection Volume Range | 1–100 µL |
| Column Oven Temperature Range | Ambient +5 °C to 100 °C |
| UV-Vis Wavelength Range | 190–800 nm |
| Data Acquisition Frequency | 50 Hz |
| Brand | Beifen Ruili |
|---|---|
| Origin | Beijing, China |
| Model | SY9230 |
| Instrument Type | Laboratory Benchtop Ion Chromatograph |
| Application Scope | General-Purpose Anion and Cation Analysis |
| Pump Pressure Range | 0–35 MPa |
| Flow Rate Range | 0–9.999 mL/min |
| Eluent Flow Rate Accuracy | 0.1–5.0 mL/min |
| Max Operating Pressure | 35 MPa |
| Column Oven Temperature Range | Ambient +5 °C to 60 °C |
| Temperature Stability | ±0.2 °C |
| Eluent Concentration Range | 0.1–100 mM |
| Fluidic Path Material | Full-PEEK (Polyetheretherketone) |
| Eluent Generation | On-Demand Electrolytic Eluent Generator (EG) with Water-Only Input |
| Degassing | Integrated Low-Pressure Membrane Degasser + Gas-Liquid Separator |
| Safety Features | Real-Time Pressure Monitoring, Leak Detection, Eluent Reservoir Level Sensing, Auto-Shutdown Protocol |
| Consumables Monitoring | Column & Suppressor Usage Tracking with Auto-Recognition of New Units |
| Compliance Support | Designed for GLP/GMP environments |
| [Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | AH3S-20A Plus |
| Carrier Gas Pressure Range & Control | 14.5 psi |
| Maximum Injector Temperature | 260 °C |
| Detector Configuration | Dual FID |
| Compatible Sample Introduction | Automated Headspace Sampler (AHS-20A Plus) |
| Column Compatibility | HP-1 and HP-1wax capillary columns |
| Operating Standard | YC/T 207–2006] |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | AHS-20A PLUS |
| Instrument Type | Laboratory Headspace Sampler |
| Application Scope | General-Purpose |
| Temperature Control Range | 100–350 °C |
| Heating Rate | 0.1–40 °C/min |
| Cooling Time | ~6 min (from 100 to 350 °C) |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injection Port Max Operating Temperature | 100–350 °C |
| Injection Port Pressure Setting Range | 0–970 kPa |
| Total Injection Port Flow Setting Range | 0–1000 mL/min |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | ASH-20A Plus + GC9860-5C |
| Temperature Control Range | 100–350 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Cool-down Time | ~6 min (from 350 °C to 100 °C) |
| Carrier Gas Flow Range | 0–1200 mL/min |
| Carrier Gas Pressure Range | 0–970 kPa |
| Injector Maximum Temperature | 100–350 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Total Injector Flow Setting Range | 0–1000 mL/min |
| Detection Method | Headspace-GC/FID |
| Compliance Standards | GB 5749–2006, GB 3838–2002, GB 8537–2008 |
| [Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Thermal Desorption System |
| Model | ATDS-20B |
| Sample Capacity | Dual 20-position (40 total) |
| Sample Tube Specification | 1/4″ × 3.5″ (ASTM D6196-compliant) |
| Injection Mode | Motor-driven 6-port valve |
| Primary Desorption Temp Range | Ambient to 450 °C |
| Secondary Desorption (Cold Trap) Temp Range | –35 °C to ambient (Peltier-cooled) |
| Transfer Line Temp Range | Ambient to 300 °C |
| Valve & Interface Temp Range | Ambient to 300 °C |
| Temperature Control Accuracy | < ±0.5 °C |
| Heating Rate (2nd Stage) | >3000 °C/min |
| Simulated Sampling Flow | 0–160 mL/min (adjustable) |
| Purge/Backflush Flow | 0–100 mL/min (adjustable) |
| Desorption Recovery | >99% (compound-dependent) |
| RSD | ≤2.5% (benzene at 0.05 μg in methanol) |
| Enrichment Time | 0–60 min |
| Injection Time | 0–60 min |
| Dimensions | 350 × 450 × 550 mm |
| Weight | ~40 kg] |
| [Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | ATDS-3420HP |
| Temperature Control Range | 100–450 °C |
| Oven Ramp Rate | 0.1–80 °C/min |
| Oven Cool-down Time | ~7 min (from 450 °C to 100 °C) |
| Carrier Gas Flow Range & Control | 0–1000 mL/min |
| Carrier Gas Pressure Range & Control | 0–400 kPa |
| Injector Maximum Temperature | 450 °C |
| Injector Pressure Setting Range | 0–400 kPa |
| Injector Total Flow Setting Range | 0–100 mL/min] |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Yes |
| Type | Domestic |
| Model | BFS-9860 |
| Pricing | Upon Request |
| Detection Gases | H₂ (0–2000 µL/L, LOD 2 µL/L, RSD ≤10%), CO (0–5000 µL/L, LOD 25 µL/L, RSD ≤10%), CH₄ (0–1000 µL/L, LOD 0.5 µL/L, RSD ≤10%), C₂H₄ (0–1000 µL/L, LOD 0.5 µL/L, RSD ≤10%), C₂H₆ (0–1000 µL/L, LOD 0.5 µL/L, RSD ≤10%), C₂H₂ (0–1000 µL/L, LOD 0.5 µL/L, RSD ≤10%), H₂O (optional, 2–100% RH, LOD 2% RH, RSD ≤10%), CO₂ (optional, 0–15000 µL/L, LOD 25 µL/L, RSD ≤10%) |
| Analysis Cycle | ≥1 hour (user-configurable) |
| Data Retention | 10 years |
| Temperature Control Accuracy | ±0.1°C |
| Operating Ambient | −40°C to +70°C, 5–95% RH (non-condensing) |
| Power Supply | AC 220 V ±10%, 50 Hz, THD <5% |
| Carrier Gas | High-purity compressed air (≥400 analyses per cylinder) |
| Mechanical Robustness | Compliant with GB/T 14537 (Shock, Class I) and GB/T 11287 (Vibration, Class I) |
| EMC Compliance | GB/T 17626, IEC 61000, Q/GDW 535–2010 |
| Communication Interfaces | RS-485, Ethernet, Fiber Optic, CAN bus, GPRS/CDMA |
| Network Scalability | Up to 16 field units per central server |
| Alarm Output | Dual-level (audible/visual), remote signal transmission |
| Software Platform | SQL Server 2000, role-based access control, IEC 61850 support, TCP/IP native |
| [Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application | Environmental Emission Monitoring (Fixed Sources & Ambient Air) |
| Oven Temperature Range | 15–380 °C |
| Oven Ramp Rate | 15–23 °C/min |
| Oven Cool-down Rate | 320 °C → 45 °C |
| Carrier Gas Flow Range | 0–672 mL/min (electronically controlled) |
| Carrier Gas Pressure Range | 0–850 kPa (pressure-programmable) |
| Injector Max Temp | 320 °C |
| Injector Pressure Setting Range | 0–540 kPa |
| Injector Total Flow Setting Range | 0–820 mL/min |
| Detection Principle | Flame Ionization Detection (FID) with Dual-Packed Column Configuration (Total Hydrocarbons Column + Methane-Specific Column) |
| Compliance | HJ 38–2017, HJ 604–2017 |
| Column Configuration | Dual 2 m × 4 mm Stainless Steel Packed Columns (THC and CH₄ separation) |
| Injection System | Ten-Port Valve for Direct Gas Sampling |
| Data Acquisition | Integrated GC Workstation with Audit Trail Support] |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | G11C-9860 |
| Temperature Control Range | 100–350 °C |
| Heating Rate | 0.1–40 °C/min |
| Cooling Time | ~6 min (from 350 °C to 100 °C) |
| Carrier Gas Flow Range | 0–1200 mL/min |
| Carrier Gas Pressure Range | 0–970 kPa |
| Injector Maximum Temperature | 100–350 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1000 mL/min |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Food Industry-Specific Fatty Acid Profiling |
| Compliance | GB/T 17376–2008 & GB/T 17377–2008 |
| Detector | FID with Auto-Ignition |
| Column Compatibility | FFAP Capillary Column (30 m × 0.32 mm) |
| Temperature Control | 10-zone, ±0.1–0.2 °C accuracy, up to 450 °C |
| Programmed Heating | 16-step, 0.1–40 °C/min ramp rate |
| Data System | Built-in GC control and acquisition software with valve timing control |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | GC-2010 |
| Temperature Control Range | +8 °C to 400 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Cooling Rate | ~6 min (400 °C → 50 °C) |
| Carrier Gas Flow Range | 0–1200 mL/min |
| Carrier Gas Pressure Range | 0–970 kPa |
| Injector Max Temp | 400 °C |
| Injector Pressure Setpoint Range | 0–970 kPa |
| Injector Total Flow Setpoint Range | 0–1200 mL/min |
| Temperature Accuracy | ±0.1 °C (≤200 °C), ±0.2 °C (>200 °C) |
| Programmed Temperature Ramping | 8-step linear |
| Minimum Temp Increment | 0.1 °C |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | GC-2010 |
| Instrument Type | Laboratory Gas Chromatograph |
| Temperature Control Range | 5 °C above ambient to 400 °C |
| Max. Oven Ramp Rate | 40 °C/min |
| Cooling Rate | 320 °C/min (with intelligent back-door system) |
| Carrier Gas Flow Range & Control | 0–856 mL/min |
| Carrier Gas Pressure Range & Control | 0–621 psi |
| Injector Max. Operating Temperature | 420 °C |
| Injector Pressure Setting Range | 0–532 psi |
| Total Injector Flow Setting Range | 0–452 mL/min |
| Detection System | FID with optimized hydrocarbon response |
| Column Configuration | 50 m × 0.53 mm ID × 0.25 µm PLOT capillary column |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Pharmaceutical Analysis |
| Oven Temperature Range | Ambient to 400°C |
| Ramp Rate | 0.1–40°C/min |
| Cool-down Rate | 400°C to 50°C in ≤6 min |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–800 kPa |
| Injector Maximum Temperature | 400°C |
| Injector Pressure Setting Range | 0–800 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Pharmaceutical Analysis |
| Oven Temperature Range | Ambient to 400 °C |
| Ramp Rate | 0.1–40 °C/min |
| Cooling Rate | 400 °C → 50 °C in ≤6 min |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–800 kPa |
| Injector Maximum Temperature | 400 °C |
| Injector Pressure Setting Range | 0–800 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Pharmaceutical Analysis |
| Oven Temperature Range | Up to 420 °C |
| Maximum Ramp Rate | 40 °C/min |
| Cooling Rate | 420 °C → 50 °C in ~6 min |
| Carrier Gas Flow Range & Control | 0–999 mL/min |
| Carrier Gas Pressure Range & Control | 0–990 kPa |
| Injector Temperature | Up to 420 °C |
| Injector Pressure Setting Range | 0–990 kPa |
| Total Injector Flow Setting Range | 0–999 mL/min |
| [Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Domain | Forensic Alcohol Testing & Clinical Toxicology |
| Temperature Control Range | 295 °C |
| Maximum Ramp Rate | 26 °C/min |
| Cooling Rate | 374 °C/min |
| Carrier Gas Flow Range & Control | 0–487 mL/min |
| Carrier Gas Pressure Range & Control | 0–472 kPa |
| Injector Maximum Operating Temperature | 276 °C |
| Injector Pressure Setting Range | 0–492 kPa |
| Total Injector Flow Setting Range | 0–560 mL/min] |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic Laboratory GC |
| Model | GC-2010F |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose / Forensic Toxicology |
| Oven Temperature Range | 420 °C |
| Maximum Ramp Rate | 40 °C/min |
| Cool-down Time | ~8 min (from 420 °C to 50 °C) |
| Carrier Gas Flow Range & Control | 0–800 mL/min |
| Carrier Gas Pressure Range & Control | 0–600 kPa |
| Injector Maximum Operating Temperature | 420 °C |
| Injector Pressure Setting Range | 0–600 kPa |
| Injector Total Flow Setting Range | 0–800 mL/min |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic (China) |
| Model | GC-2011A |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Pharmaceutical Analysis |
| Oven Temperature Range | Ambient to 400 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Oven Cooling Rate | 400 °C → 50 °C in ≤6 min |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–800 kPa |
| Injector Maximum Temperature | 400 °C |
| Injector Pressure Setting Range | 0–800 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |