Chromatography Instruments
Filter
Showing 361–390 of 701 results
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Conventional HPLC System |
| Model | Anters-1200V |
| Flow Rate Range | 0.001–5 mL/min |
| Maximum Pressure | 40 MPa |
| Sample Tray Capacity | 144 positions (2 mL vials) |
| Injection Volume Range | 0.1–100 µL |
| Column Oven Temperature Range | −20 °C to 100 °C |
| UV-Vis Wavelength Range | 190–850 nm |
| Data Acquisition Rate | 100 Hz |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Post-Column Derivatization System |
| Model | Anters-1500A |
| Pump Flow Rate | 0.01–9.99 mL/min |
| Maximum Pump Pressure | 40 MPa |
| Autosampler Injection Volume | 1–5000 µL |
| Autosampler Temperature Control Range | 5–70 °C |
| Post-Column Reactor Temperature Range | Ambient to 199 °C |
| Detection Wavelength | 570 nm (dual-wavelength detection at 440 nm & 570 nm) |
| Flow Cell Volume | 8 µL |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | FlashDoctor-2500 |
| Instrument Type | Fast Liquid Chromatography System |
| Application Scope | General-purpose |
| Flow Rate Range | 0–200 mL/min |
| Maximum Pressure | 5 MPa |
| Flow Accuracy | 0.1% RSD |
| Wavelength Range | 190–850 nm |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | TLC Scanner |
| Operation Mode | Fully Automatic |
| Measurement Modes | Reflectance, Fluorescence (optional), Absorbance |
| Wavelength Range | 190–700 nm (auto-configurable) |
| Light Source | Deuterium Lamp + Tungsten-Halogen Lamp |
| Monochromator | Holographic Grating |
| Spectral Bandwidth | 5 nm |
| Wavelength Accuracy | ≤ ±1 nm |
| Wavelength Repeatability | RSD ≤ 2.0% |
| Minimum Spatial Resolution | 25 µm |
| Imaging Wavelength Range | 190–700 nm |
| Sample Stage Capacity | Accommodates 200 mm × 200 mm TLC plates |
| Maximum Scan Speed | 100 mm/s |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | KH-2300 |
| Instrument Type | TLC Scanner |
| Operation Mode | Fully Automatic |
| Measurement Modes | Reflectance, Fluorescence (optional), Absorbance |
| Wavelength Range | 190–700 nm (automatically programmable) |
| Light Source | Deuterium Lamp + Tungsten Halogen Lamp |
| Monochromator | Holographic Grating |
| Spectral Bandwidth | 5 nm |
| Wavelength Accuracy | ≤ ±1 nm |
| Wavelength Repeatability | RSD ≤ 2.0% |
| Minimum Spatial Resolution | 25 µm |
| Imaging Wavelengths | 254 nm, 365 nm, White Light |
| Sample Stage Capacity | Up to 20 × 30 cm TLC plates of arbitrary thickness |
| Scanning Speed | 0–50 mm/s |
| Auto-sampler Capacity | 96 × 2 mL vials |
| Minimum Spot Volume | 10 nL |
| Spotting Modes | Circular, Band, Square |
| Band Length Range | 5–195 mm |
| Heating Base Temperature Range | 30–60 °C (±1 °C) |
| Optional Accessories | TS-II Dual-Nozzle Electrospray Nebulizer, TD-II Automated TLC Plate Coater, TK-10 Electronic Development Chamber |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | KH-3000 |
| Instrument Category | TLC Scanner |
| Wavelength Range | 190–900 nm (continuously adjustable) |
| Light Sources | Deuterium lamp & tungsten-halogen lamp (auto-switching) |
| Monochromator | Holographic grating (1200 lines/mm) |
| Spectral Bandwidth | 10 nm |
| Wavelength Accuracy | ±0.5 nm |
| Minimum Resolution | 25–50 µm |
| Sample Stage | Accommodates 200 mm × 200 mm TLC plates |
| Scan Speed | 0–120 mm/s |
| Detection Modes | Absorbance & optional Fluorescence |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | TLC Densitometer |
| Measurement Modes | Reflectance Absorption, Reflectance Fluorescence, Transmission Absorption, Transmission Fluorescence, Chemiluminescence |
| Wavelength Range | 190–900 nm (continuously adjustable) |
| Light Sources | Tungsten-halogen lamp, Deuterium lamp, Mercury lamp (auto-switching) |
| Monochromator | Holographic grating (1200 lines/mm) with nitrogen purge capability |
| Spectral Bandwidth | 5 nm / 10 nm / 20 nm (user-selectable |
| Wavelength Accuracy | ±0.5 nm |
| Wavelength Repeatability | <0.1 nm |
| Minimum Spatial Resolution | 10–25 µm |
| Imaging Wavelengths | 254 nm, 365 nm, White Light (fully automated control) |
| Sample Stage Capacity | Accommodates 200 mm × 200 mm TLC plates (customizable up to 300 mm × 200 mm) |
| Scan Speed | 0–120 mm/s |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | TLC Scanner |
| Measurement Mode | Absorption (Fluorescence optional) |
| Wavelength Range | 190–800 nm |
| Light Sources | Xenon lamp, Tungsten-halogen lamp, High-pressure Mercury lamp |
| Monochromator | Holographic grating (1200 lines/mm) with nitrogen purge capability |
| Spectral Bandwidth | 5 nm |
| Wavelength Accuracy | < ±1 nm |
| Wavelength Repeatability | < ±0.2 nm |
| Minimum Resolution | 25 µm |
| Imaging Wavelengths | 254 nm, 365 nm, White light |
| Sample Stage Capacity | 200 mm × 200 mm TLC plate |
| Maximum Scan Speed | 100 mm/s |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | TLC Scanner |
| Measurement Modes | Reflectance Absorption, Reflectance Fluorescence, Transmittance Absorption, Transmittance Fluorescence, Chemiluminescence |
| Wavelength Range | 190 nm – 1000 nm |
| Light Sources | Tungsten-Halogen Lamp, Deuterium Lamp, Mercury Lamp (Auto-Switching) |
| Monochromator | Holographic Grating (1200 lines/mm) with Nitrogen Purge Function |
| Spectral Bandwidth | 5 nm / 10 nm / 20 nm (Selectable) |
| Wavelength Accuracy | ±0.5 nm |
| Wavelength Reproducibility | < 0.1 nm |
| Minimum Spatial Resolution | 10–25 µm |
| Imaging Wavelengths | 254 nm, 365 nm, White Light (Fully Automated Control) |
| Sample Stage | Accommodates 200 mm × 200 mm TLC plates (customizable to 300 mm × 200 mm) |
| Scan Speed | 0–120 mm/s |
| A/D Converter | 24-bit, 8-channel, 20 µs dual conversion |
| Slit Dimensions | Length 0–8 mm, Width 0–4 mm (Continuously Variable, PC-Controlled) |
| Fluorescence Filters | Standard set of six (K320, K360, K400, K450, K510, K550) |
| Detector | Photomultiplier Tube (PMT) |
| Data Acquisition Rate | 30,000 data points per second |
| Communication Interface | USB 2.0 |
| Compliance | Fully supports 21 CFR Part 11, electronic signatures, and IQ/OQ/PQ validation protocols |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Preparative Thin-Layer Chromatograph |
| Model | KH-CTLC-II |
| Wavelengths | 254 nm and 365 nm (UV) |
| Light Source | Dual-band UV Lamp |
| Sample Platform | Rotating Circular TLC Plate (Ø245 mm) |
| Flow Rate Range | 0–15 mL/min |
| Flow Accuracy | ±1% |
| Separation Capacity | 100 mg–2 g per run |
| Rotational Speed | 100–1450 rpm |
| Plate Thickness Options | 1, 2, 3, 4, 6, 8 mm |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | SP-20E |
| Instrument Type | Automated TLC Sample Spotter |
| Detection Modes | Reflectance Absorption, Reflectance Fluorescence, Transmission Absorption, Transmission Fluorescence |
| Wavelength Range | 190–800 nm |
| Light Sources | Xenon Lamp, Tungsten-Halogen Lamp, High-Pressure Mercury Lamp |
| Monochromator | Holographic Grating (1200 lines/mm) with Nitrogen Purge Capability |
| Spectral Bandwidth | 5 nm |
| Wavelength Accuracy | < 1 nm |
| Wavelength Repeatability | < 0.2 nm |
| Minimum Spatial Resolution | 25 µm |
| Imaging Wavelengths | 254 nm, 365 nm, White Light |
| Sample Stage Capacity | Up to 200 mm × 200 mm TLC Plates |
| Maximum Scanning Speed | 100 mm/s |
| Spotting Mode | Contactless Linear Band Deposition |
| Spotting Length | 5–195 mm (customizable) |
| Spotting Volume | 1–20 µL (customizable up to higher volumes) |
| Flow Rate Options | 0.5, 1, 2, 5, 10 µL/min |
| Power Supply | 220 V, 50 Hz, 90 W |
| Software Platform | Windows 7/10 Compatible Dedicated TLC Spotting Workstation |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | SP-20Start |
| Instrument Type | Thin-Layer Chromatography (TLC) Sample Spotter |
| Spotting Mode | Non-contact |
| Spot Shape | Circular or Linear Band |
| Maximum Spotting Length | 150 mm |
| Plate Size Compatibility | 200 mm × 200 mm |
| Spotting Volume Range | 1–20 µL (customizable up to 100 µL) |
| Spotting Accuracy | < 0.2% RSD |
| Spotting Reproducibility | < 0.5% RSD |
| Minimum Band Width | 0.2 mm |
| Syringe Options | 10, 25 (standard), 50, and 100 µL |
| X-Axis Resolution | 200 steps/mm |
| Y-Axis Resolution | 400 steps/mm |
| Syringe Drive Resolution | 3200 steps/mm (6400 steps/µL for 25 µL syringe) |
| Operating Pressure | 0.4 MPa (N₂ or compressed air) |
| Gas Flow Rate | 2–3 L/min |
| Heating Stage Temperature Range | Ambient to 60 °C (±1 °C stability) |
| Power Supply | 220 V, 50 Hz, 90 W |
| Control Interface | Integrated 7-inch capacitive touchscreen |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | SP-30E |
| Instrument Category | TLC Sample Spotter |
| Measurement Modes | Reflectance Absorption, Reflectance Fluorescence, Transmission Absorption, Transmission Fluorescence |
| Wavelength Range | 190–800 nm |
| Light Sources | Xenon Lamp, Tungsten-Halogen Lamp, High-Pressure Mercury Lamp |
| Monochromator | Holographic Grating (1200 lines/mm) with Nitrogen Purge Capability |
| Spectral Bandwidth | 5 nm |
| Wavelength Accuracy | <1 nm |
| Wavelength Repeatability | <0.2 nm |
| Minimum Resolution | 25 µm |
| Imaging Wavelengths | 254 nm, 365 nm, White Light |
| Sample Stage Capacity | Up to 200 mm × 200 mm TLC Plates |
| Maximum Scanning Speed | 100 mm/s |
| Spotting Volume Range | 10 nL – 2 mL |
| Spotting Precision | ±1.25 nL (with 25 µL syringe) |
| Syringe Options | 10 µL, 25 µL (standard), 50 µL, 100 µL |
| X/Y/Axial Drive Resolution | 200 steps/mm (X), 400 steps/mm (Y), 3200 steps/mm (syringe) |
| Heating Stage Range | Ambient to 60 °C (±1 °C) |
| Heated Nozzle | 30–80 °C |
| Auto-sampler Capacity | 96 × 2 mL vials |
| Gas Supply | 0.4 MPa, N₂ or compressed air |
| Flow Rate | 2–3 L/min |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | SP-II |
| Instrument Category | TLC Sample Spotter |
| Sample Application Modes | Circular Spot & Linear Band |
| Spotting Range | 0–200 mm |
| Spotting Temperature Range | Ambient to 100 °C |
| Heating Platform Temperature Range | Ambient to 200 °C |
| Heating System | CNC Digital Display Heated Stage with Uniform Heat Distribution Plate |
| Drive Mechanism | High-Reliability Shanghai Brand Stepper Motor Assembly |
| Spotting Precision | Contact-Based, Non-Sticking Needle Interface |
| Compliance | Designed for GLP-aligned laboratory workflows and compatible with ISO 17025 traceability requirements |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | TBOX-I |
| Instrument Category | TLC Auxiliary Equipment |
| Sample Plate Size | 200 × 200 mm |
| Airflow Capacity | 4000 L/min |
| Construction Materials | Stainless Steel Enclosure, Corrosion-Resistant Gas Conduit, Integrated Spray Stand |
| Noise Level | Low-Noise Operation |
| Compliance | Designed for ISO/IEC 17025-aligned laboratory safety workflows |
| Software Interface | None (Standalone Mechanical System) |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | TD-I |
| Plate Width Compatibility | 50 mm, 100 mm, 200 mm |
| Adjustable Coating Thickness Range | 0–2.5 mm |
| Plate Size Support | Standard 200 mm × 200 mm (customizable to 300 mm × 200 mm) |
| Construction | CNC-machined stainless steel and anodized aluminum components |
| Includes | Multi-size carrier tray, adjustable slurry reservoir, integrated mini slurry homogenizer, precision thickness gauge |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Model | TD-II |
| Plate Thickness Range | 0–3 mm (continuously adjustable) |
| Plate Width Options | 100 mm & 200 mm |
| Coating Cycle Time | ≤10 seconds per plate |
| Single-Batch Capacity | 4×(200×200 mm), 8×(200×100 mm), or 16×(100×100 mm) plates |
| Power Supply | 220 V, 50 Hz, 10 W (main unit only) |
| Construction | Stainless steel frame and wetted components |
| Compliance | Designed to meet Chinese Pharmacopoeia 2015 Edition requirements for quantitative TLC |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic (China-made) |
| Model | TH-II |
| Instrument Type | TLC Ancillary Equipment |
| Detection Modes | Reflectance Absorption, Reflectance Fluorescence, Transmittance Absorption, Transmittance Fluorescence |
| Wavelength Range | 190–800 nm |
| Light Sources | Xenon Lamp, Tungsten-Halogen Lamp, High-Pressure Mercury Lamp |
| Monochromator | Holographic Grating (1200 lines/mm), Nitrogen Purge Capable |
| Spectral Bandwidth | 5 nm |
| Wavelength Accuracy | < 1 nm |
| Wavelength Repeatability | < 0.2 nm |
| Minimum Spatial Resolution | 25 µm |
| Imaging Wavelengths | 254 nm, 365 nm, White Light |
| Sample Stage Capacity | 200 mm × 200 mm TLC Plate |
| Maximum Scan Speed | 100 mm/s |
| Temperature Range | 0–200 °C |
| Temperature Accuracy | ≤ ±1 °C |
| Heating Platform Dimensions | 300 mm × 250 mm |
| Power Supply | 220 V AC, 600 W |
| Heating Element | Cast-Aluminum Block with Uniform-Heat Plate |
| Construction | Stainless Steel Sample Tray, Digital PID Temperature Controller |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Forced-Flow TLC Development System |
| Model | TK-10 |
| Wavelength Options | 254 nm or 365 nm |
| Maximum Plate Size | 200 mm × 200 mm |
| Development Distance Range | 10–200 mm |
| Development Distance Accuracy | ≤1 mm |
| Interface | USB |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Automated TLC Development System |
| Model | TK-20E |
| Operation Mode | Fully Automatic |
| Maximum Plate Size | 200 mm × 200 mm |
| Development Distance Range | 40–180 mm |
| Development Distance Accuracy | ≤1 mm |
| Humidity Control Range | 10–90% RH (65–90% RH requires optional humidification module) |
| Gas Flow Rate | 0–16 L/min |
| Solvent Consumption | ≤20 mL per run |
| Interface | RS232 / USB |
| Temperature & Humidity Monitoring | Real-time onboard sensors |
| Compliance Support | GLP/GMP workflows and FDA 21 CFR Part 11 audit trail capability via software |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic (PRC-Made) |
| Model | TK-II |
| Price Range | USD 1,400 – 4,200 (FOB Shanghai) |
| Instrument Type | TLC Ancillary Equipment Suite |
| UV Wavelengths | 254 nm & 365 nm |
| Max Plate Size Supported | 200 × 200 mm |
| Min Plate Size Supported | 25 × 75 mm (development), 50 × 50 mm (storage) |
| Imaging Platform | Integrated dark chamber with dual-band UV illumination |
| Resolution | Single-band spectral isolation via fixed-wavelength UV lamps |
| Scan Capability | Visual observation and photographic documentation only (no motorized scanning or densitometry) |
| Plate Handling | Manual positioning |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | TM-200 |
| Instrument Type | TLC–MS Interface |
| Measurement Mode | Transmission Absorption |
| Wavelength Range | 190–800 nm |
| Light Source | Laser |
| Laser Power | 5 mW |
| Spectral Bandwidth | 5 nm |
| Wavelength Accuracy | < 1 nm |
| Wavelength Repeatability | < 0.2 nm |
| Minimum Spatial Resolution | 25 µm |
| Imaging Wavelength | 254 nm |
| Maximum TLC Plate Size | 200 × 200 mm |
| Solvent Flow Rate | 0.05–0.3 mL/min |
| Pneumatic Source | N₂ or Compressed Air |
| Sealing Force | Up to 500 N |
| Extraction Probe Options | Ø4 mm, Ø5 mm (circular), 4 × 2 mm (elliptical) |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | Domestic (China) |
| Model | TS-I |
| Price Range | USD 140–700 |
| Instrument Category | TLC Auxiliary Equipment |
| Spray Nozzle Diameter | 0.2 mm |
| Operating Pressure Range | 10–30 PSI |
| Maximum Spray Distance | 50 cm |
| Construction Material | Full Stainless Steel |
| Compressor Type | Imported Compact Oil-Free Air Compressor |
| Noise Level | Low-Noise Operation |
| Nozzle Replaceability | Quick-Swap Design |
| Waste Minimization | Optimized Reagent Delivery System |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | TS-II |
| Instrument Category | TLC Auxiliary Equipment |
| Detection Modes | Reflectance Absorption, Reflectance Fluorescence, Transmission Absorption, Transmission Fluorescence |
| Wavelength Range | 190–800 nm |
| Light Sources | Xenon Lamp, Tungsten-Halogen Lamp, High-Pressure Mercury Lamp |
| Monochromator | Holographic Grating (1200 lines/mm) with Nitrogen Purge Capability |
| Spectral Bandwidth | 5 nm |
| Wavelength Accuracy | < 1 nm |
| Wavelength Repeatability | < 0.2 nm |
| Minimum Spatial Resolution | 25 µm |
| Imaging Wavelengths | 254 nm, 365 nm, White Light |
| Sample Stage Capacity | Accommodates TLC Plates up to 200 mm × 200 mm |
| Maximum Scan Speed | 100 mm/s |
| Nozzle Orifice Diameters | 0.2 mm (Nozzle B), 0.3 mm (Nozzle A) |
| Spray Distance Range | 0–500 mm |
| Operating Pressure | 30 psi |
| Aerosol Particle Size Distribution | 0.1–3 µm |
| Included Components | Dedicated Low-Noise Micro Air Pump, PTFE-Coated Nozzle A, Ultrafine Stainless-Steel Nozzle B |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | TY-10 |
| Instrument Category | TLC Auxiliary Equipment |
| Maximum Plate Size | 200 × 100 mm (standard), 200 × 200 mm (customizable) |
| Immersion Speed | 0–10 mm/s (adjustable) |
| Configuration Includes | Reagent Reservoir Tank, Main Derivatization Unit, TLC Plate Holder Assembly, Dedicated Control Software |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | TY-I |
| Instrument Category | TLC Imaging & Derivatization System |
| Light Sources | UV 254 nm, UV 365 nm, Visible White Light |
| Imaging Resolution | ≥4 MP |
| Maximum Sample Platform Size | 200 × 200 mm |
| Derivatization Modes | Immersion and Spray |
| Immersion Chamber Options | 200 mm and 100 mm formats |
| Compliance | Designed for GLP-compliant manual derivatization workflows in analytical laboratories |
| Brand | KEZHE / KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | SP-III |
| Instrument Category | Thin-Layer Sample Applicator |
| Operation Mode | Automatic |
| Measurement Modes | Reflectance Absorption, Reflectance Fluorescence, Transmission Absorption, Transmission Fluorescence |
| Wavelength Range | 190–800 nm |
| Light Sources | Xenon Lamp, Tungsten-Halogen Lamp, High-Pressure Mercury Lamp |
| Monochromator | Holographic Grating (1200 lines/mm), Nitrogen Purge Compatible |
| Spectral Bandwidth | 5 nm |
| Wavelength Accuracy | < 1 nm |
| Wavelength Repeatability | < 0.2 nm |
| Minimum Spatial Resolution | 25 µm |
| Imaging Wavelengths | 254 nm, 365 nm, White Light |
| Sample Stage Capacity | Up to 200 mm × 200 mm TLC Plates |
| Scanning Speed | Up to 100 mm/s |
| Spotting Length | 0–200 mm |
| Spotting Width | 0.7–3 mm (Standard: 1–2 mm) |
| Spotting Temperature Range | Ambient to 100 °C |
| Heating Platform Temperature Range | Ambient to 200 °C |
| Spotting Modes | Circular Spot, Linear Strip, Contact & Non-Contact |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TS-20E |
| Operation Mode | Fully Automatic |
| Measurement Modes | Reflectance Absorption, Reflectance Fluorescence, Transmittance Absorption, Transmittance Fluorescence |
| Wavelength Range | 190–800 nm |
| Light Sources | Xenon Lamp, Tungsten-Halogen Lamp, High-Pressure Mercury Lamp |
| Monochromator | Holographic Grating (1200 lines/mm) with Nitrogen Purge Capability |
| Spectral Bandwidth | 5 nm |
| Wavelength Accuracy | < 1 nm |
| Wavelength Repeatability | < 0.2 nm |
| Minimum Spatial Resolution | 25 µm |
| Imaging Wavelengths | 254 nm, 365 nm, White Light |
| Sample Stage Capacity | Accommodates TLC Plates up to 200 mm × 200 mm |
| Maximum Scanning Speed | 100 mm/s |
| Syringe Volume Range | 0.2–10 mL |
| Liquid Handling Speed | 0.1–25 mL/min (Aspiration/Dispense/Clean) |
| Pre-spray Area (X/Y) | 0–100 mm / 0–200 mm |
| Full Spray Area (X/Y) | 0–200 mm / 0–200 mm |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic (China-Made) |
| Model | TU-I |
| Price Range | USD 140–700 (FOB) |
| Instrument Class | TLC Ancillary Device |
| UV Wavelengths | 254 nm & 365 nm |
| Filter Dimensions | 150 × 50 mm |
| Portability | Handheld, Compact Design |
| Compliance | Designed for laboratory-grade TLC plate inspection per standard analytical workflows |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | TU-II |
| Price Range | USD 140 – 700 (FOB) |
| Instrument Type | TLC Auxiliary Equipment |
| UV Wavelengths | 254 nm & 365 nm |
| Max Sample Size | 200 × 200 mm TLC Plate |
| Design | Portable, Light-Tight Enclosure |
| UV Lamp Configuration | Dual-Wavelength Integrated Fluorescent Lamps |