| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Category | Domestic Lab-Scale Gas Chromatograph |
| Model | GC-2000 Universal |
| Application Scope | General-Purpose Analytical Chemistry |
| Control Interface | Full-Touch Color LCD Display |
| Pneumatic Control | Electronic Pressure and Flow Control (EPC) |
| Software Architecture | Modular Workstation with Method-Driven Workflow |
| Microfluidic Capability | Valveless Flow Switching for Column Back-Flush, Detector Selection, and GC-MS Parallel Operation |
| Compliance Context | Designed for GLP/GMP-aligned laboratories |
| Brand | Fuli |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | F60 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-purpose |
| Detector Options | FID, FPD |
| Control Interface | 7-inch TFT capacitive touchscreen |
| Gas Control | Mechanical valves with electronic pressure & flow monitoring |
| Column Oven | Dual-sensor temperature monitoring, thermal fuse protection, flame-retardant materials (UL94 V-0 rated) |
| Compliance | Designed to support GLP/GMP workflows, ASTM D3606/D1319, ISO 17025-aligned operation |
| Brand | Fuli |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | F70 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose Analysis |
| Control Architecture | Dual-AFC (Carrier Gas & Detector Auxiliary Gas) or Full-AFC Mode |
| Detection Systems | FID, FPD (Wide-Range Configurable) |
| Injection Options | Multiple Configurable Inlet Types |
| Software Platforms | FL97Plus, MyLab Chromatography Data Systems (CDS) |
| Compliance Framework | Designed for GLP/GMP-aligned workflows with audit trail-ready CDS options |
| Human-Machine Interface | 7-inch capacitive touchscreen with real-time multi-channel status visualization |
| Maintenance Intelligence | Consumables tracking (septa, liner, split cold trap), usage-based alerts, and automated leak-check protocol |
| Brand | Fuli |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | F70 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | 6 °C to 400 °C |
| Maximum Ramp Rate | 120 °C/min |
| Cooling Rate | <7.0 min from 350 °C to 50 °C |
| Carrier Gas Flow Range & Control | 0–450 mL/min |
| Carrier Gas Pressure Range & Control | 0–100 psi |
| Electronic Pressure Control (EPC), pressure setting resolution | 0.01 psi |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–100 psi |
| Injector Total Flow Setting Range | 0–450 mL/min |
| Brand | Fuli |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Class | Ultra-High-Performance Liquid Chromatograph (UHPLC) |
| Application Scope | General-Purpose LC Analysis |
| Model | L75 |
| Pricing | Upon Request |
| Brand | Fuli |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Category | Domestic |
| Model | LC5090Plus |
| Pricing | Upon Request |
| Instrument Type | Ultra-High Performance Liquid Chromatograph (UHPLC) |
| Application Scope | General-Purpose Analytical Use |
| Brand | Fuli |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | LC5190 |
| Instrument Type | Conventional High-Performance Liquid Chromatograph (HPLC) |
| Application Scope | General-Purpose Analytical Instrument |
| Flow Rate Accuracy | ≤0.1% RSD |
| Pressure Range | Up to 60 MPa |
| Wavelength Range (UV Detector) | 190–900 nm |
| Injection Volume Precision | ±0.1 µL |
| Column Temperature Control Range | 5–85 °C (with cooling & heating) |
| Detection Modes Supported | UV-Vis, DAD, FL, ELSD, RI |
| Brand | Fulit |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | F60 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Temperature Control Range | 6°C to 400°C |
| Maximum Ramp Rate | 120°C/min |
| Cooling Time | <7.0 min (from 350°C to 50°C) |
| Carrier Gas Flow Control | Electronic Flow Display |
| Carrier Gas Pressure Control | Electronic Pressure Display |
| Injector Maximum Operating Temperature | 400°C |
| Brand | Fulit |
|---|---|
| Origin | Zhejiang, China |
| Model | F70pro |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-purpose |
| Oven Temperature Range | 6 °C to 400 °C |
| Maximum Ramp Rate | 120 °C/min |
| Cooling Rate | <3.0 min from 200 °C to 100 °C |
| Carrier Gas Flow Range & Control | 0–450 mL/min with Electronic Pressure Control (EPC) for carrier gas and Automatic Flow Control (AFC) for auxiliary gases |
| Carrier Gas Pressure Range & Control | 0–100 psi with EPC |
| pressure control resolution | 0.001 psi |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–100 psi |
| Injector Total Flow Setting Range | 0–450 mL/min |
| Brand | Fulit |
|---|---|
| Origin | Zhejiang, China |
| Model | F80 |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Application Scope | General-Purpose GC Analysis |
| Oven Temperature Range | 4 °C to 450 °C |
| Maximum Ramp Rate | 250 °C/min |
| Cooling Rate | <5.0 min from 450 °C to 50 °C |
| Carrier Gas Flow Range & Control | 0–1250 mL/min (H₂ or He), 0–500 mL/min (N₂) |
| Carrier Gas Pressure Range & Control | 0–100 psi (standard), optional 0–150 psi |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–100 psi (standard), optional 0–150 psi |
| Injector Total Flow Setting Range | 0–1250 mL/min (H₂/He), 0–500 mL/min (N₂) |
| Control System | Integrated high-resolution touchscreen interface with embedded real-time GC control firmware |
| Brand | GAOMAI |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | GM Explosion-Proof Enclosure |
| Price Range | USD 70,000 – 140,000 |
| Instrument Type | External Protective Enclosure for Portable Gas Chromatographs |
| Application Scope | General-Purpose Hazardous Area Deployment |
| Explosion Protection Rating | Exdp II BT1 to Exdp II CT6 (GB 3836 Compliant) |
| IP Rating | IP65 |
| Internal Pressure Range | 30–100 Pa |
| Power Supply | 220 VAC ±10%, 50 Hz |
| Construction Materials | EP-grade stainless steel tubing (welded or VCR-fitted) |
| Viewing Window | Shatter-resistant explosion-proof borosilicate glass |
| Certification Basis | GB 3836.1–2010, GB 3836.5–2017 |
| Brand | Huazhun Chromatography |
|---|---|
| Model | GC-2021plus |
| Origin | Jiangxi, China |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-purpose |
| Oven Temperature Range | 5 °C to 450 °C |
| Maximum Ramp Rate | 250 °C/min |
| Cooling Rate | ≤8 min (from 350 °C to 50 °C at 25 °C ambient) |
| Carrier Gas Flow Control Range | 0–200 mL/min (N₂), 0–1250 mL/min (H₂ or He) |
| Carrier Gas Pressure Control Range | 0–1035 kPa (0–150 psi) |
| Injector Maximum Operating Temperature | 420 °C |
| [Brand | Jinpu |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GC-7890 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | Ambient +5°C to 450°C (adjustable in 0.1°C increments) |
| Ramp Rate | 0.1–40°C/min (0.1°C increment) |
| Cooling Rate | 450°C → 50°C in ≤6 min |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Operating Temperature | 400°C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Temperature Stability (≤180°C) | ±0.01°C |
| Column Configuration Support | Dual packed columns + one capillary column, or dual capillary columns |
| Detector Compatibility | Dual TCD, dual FID, or simultaneous TCD/FID operation |
| Programmed Temperature | 8-step ramping across 6 independently controlled zones |
| Auto-Ignition | Yes (patented) |
| Automatic Sample Injection | Yes (patented) |
| Power Supply | 220 V ±10%, 2200 W max |
| FID Sensitivity | ≤3×10⁻¹² g/s (benzene on CS₂), Noise: ≤3×10⁻¹³ A, Drift: ≤5×10⁻¹³ A/30 min, Linearity: ≥10⁶] |
| [Brand | Huai Ai |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Regional Category | Domestic (China) |
| Model | GC-9560-HD |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Power Industry-Specific |
| Temperature Control Range | Ambient to 400 °C |
| Maximum Ramp Rate | 40 °C/min |
| Cooling Rate | 350 °C to 50 °C |
| Carrier Gas Flow Range & Control | 0–500 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.4 MPa |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–0.4 MPa |
| Injector Total Flow Setting Range | 0–800 mL/min] |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | TP101 |
| Application Scope | General-Purpose |
| Carrier Gas | Nitrogen (standard configuration) |
| Detection Principle | Partition/Adsorption Equilibrium in Gas-Solid or Gas-Liquid Systems |
| Column Compatibility | Capillary and Packed Columns |
| Operating Mode | Temperature-Programmed and Isothermal Elution |
| Detection Systems Supported | FID, TCD (configurable per application) |
| Brand | GBC |
|---|---|
| Origin | Australia |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LC 3000 |
| Pricing | Upon Request |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | BJ-GC128 |
| Price | USD 22,000 (FOB Guangdong) |
| Touchscreen | 7-inch color capacitive display |
| Control Architecture | Dual-mode—embedded real-time OS + PC-based bidirectional software control |
| EFC/EPC | Electronic Flow Control / Electronic Pressure Control on all inlets and detectors |
| Inlet Zones | 2 independently heated (up to 400 °C), compatible with packed columns (φ3/φ4) and split/splitless capillary inlets |
| Detector Options | FID (MDL ≤ 2.5×10⁻¹² g/s n-hexadecane, dynamic range 10⁷), TCD (sensitivity ≥ 5000 mV·mL/mg n-hexadecane, baseline drift ≤ 0.15 mV/30 min), ECD (⁶³Ni source, MDL ≤ 80 fg/s, γ-HCH ≤ 8×10⁻¹⁴ g/mL, dynamic range 10³), FPD (P: MDL ≤ 2×10⁻¹² g/s, S: ≤ 4×10⁻¹¹ g/s, methyl parathion, P/S dynamic range 10³/10²) |
| Oven Specifications | Internal dimensions 280 × 310 × 160 mm |
| operating range | ambient +4 °C to 420 °C |
| Auxiliary Heaters | 2 additional zones (max 400 °C) |
| External Event Ports | 8 TTL-compatible digital I/O channels for valve sequencing, autosampler triggering, or thermal desorption synchronization |
| Connectivity | RS-232 serial port, LAN (LAM protocol), 20 method storage slots |
| Safety Features | Automatic oven fan & heater shutdown upon column chamber door opening |
| Power Requirements | 220 VAC ±10%, 50/60 Hz, 3000 W max |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Category | Domestic HPLC System |
| Model | GB-LC01 |
| Price Range | USD 1,400 – 4,200 |
| Instrument Type | Laboratory-Scale Analytical & Semi-Preparative HPLC System |
| Primary Application Field | Food Safety & Quality Control |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic |
| Model | GC-9802 |
| Price Range | USD 7,000–14,000 (FOB) |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | 400 °C |
| Oven Ramp Rate | 0–40 °C/min |
| Oven Cooling Time | ~6 min (from 450 °C to 50 °C) |
| Carrier Gas Flow Control Range | 0–1200 mL/min |
| Carrier Gas Pressure Control Range | 0–970 kPa |
| Injector Maximum Temperature | 400 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Detector | FID (Hydrogen Flame Ionization Detector), Mt ≤ 1×10⁻¹¹ g/s (n-hexadecane), Baseline Drift ≤ 0.02 mV/h, Noise ≤ 0.02 mV |
| Column | OV-1701 Capillary Column (50 m × 0.32 mm ID × 0.5 μm film thickness), Max Temp 400 °C |
| Injector Type | Split/Splitless Capillary Injector (optional packed column inlet) |
| Oven Dimensions | 240 × 210 × 240 mm (W × D × H) |
| Temperature Resolution | 0.1 °C |
| Temperature Stability | ±0.1% of setpoint |
| Carrier Gases | High-purity N₂ (99.99%, 0.4 MPa, dry), H₂ (99.99%, 0.4 MPa, dry), clean oil-free air (0.4 MPa, dry) |
| Gas Line Interface | Φ3 mm tubing |
| External Dimensions | 500 × 550 × 500 mm (H × W × D) |
| Compliance | QBT 2929, GB/T 10004–2008, YBB 00132002 |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | GC-9802-A |
| Price Range | USD 14,000–21,000 |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Application Field | Food Industry-Specific Analysis |
| Oven Temperature Range | Up to 400 °C |
| Ramp Rate | 0–40 °C/min |
| Injector Maximum Operating Temperature | 400 °C |
| Detector | FID (Hydrogen Flame Ionization Detector), Optional TCD/ECD/NPD |
| FID Sensitivity | Mt ≤ 1 × 10⁻¹¹ g/s (n-Hexadecane) |
| Baseline Drift | ≤ 0.02 mV/h |
| Noise | ≤ 0.02 mV |
| Column | OV-1701 Capillary Column (50 m × 0.32 mm × 0.5 µm), Max Temp 400 °C |
| Injector Type | Split/Splitless Capillary Injector (Optional Packed Column Injector) |
| Oven Dimensions | 240 × 210 × 240 mm |
| Temperature Resolution | 0.1 °C |
| Temperature Control Accuracy | ±0.1% of setpoint |
| Carrier Gas | High-Purity N₂ (99.99%, 0.4 MPa, dry), H₂ (99.99%, 0.4 MPa, dry), Clean Air (0.4 MPa, oil-free, particle-free) |
| Gas Line Connection | Φ3 mm tubing |
| External Dimensions | 500 × 550 × 500 mm (H × W × D) |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic Lab-Scale Gas Chromatograph |
| Model | GC-9802-P |
| Price Range | USD 14,000–21,000 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Environmental & Medical Device Compliance Testing |
| Detector | Hydrogen Flame Ionization Detector (FID) |
| Detection Limit | ≤3×10⁻¹² g/s (n-Hexadecane) |
| Baseline Noise | ≤2×10⁻¹⁴ A |
| Baseline Drift | ≤1×10⁻¹³ A/30 min |
| Column | EO-Specific Capillary Column (30 m × 0.32 mm × 0.5 µm) |
| Oven Temperature Range | 4 °C above ambient to 450 °C (1 °C increments) |
| Temperature Control Accuracy | ±0.1 °C |
| Temperature Gradient Uniformity | ±1% |
| Independent Temperature Zones | 6 |
| Programmable Temperature Ramp Stages | 16 |
| Ramp Rate | 0.1–60 °C/min |
| Maximum Run Time | 6000 min |
| Injection Mode | Split/Splitless with Septum Purge |
| Optional Accessories | 20-Position Headspace Autosampler, Oil-Free Air Generator (3 L/min), H₂ Generator (300 mL/min, 99.999% purity), High-Purity N₂ Cylinder (99.999%) with Regulator |
| Software | Dual-Channel Chinese-Language GC Workstation with Instrument Control, Real-Time Chromatogram Display, Zoom/Scroll Functionality, PDF Report Export, and Manual Trigger Button Support |
| Brand | GBPI |
|---|---|
| Model | GC-9802A |
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | 40–400 °C |
| Temperature Ramp Rate | 0–40 °C/min |
| Cool-Down Time | ~6 min (450 °C → 50 °C) |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Detector | FID (Hydrogen Flame Ionization Detector), Mt ≤ 1×10⁻¹¹ g/s (n-Hexadecane), Baseline Drift ≤ 0.02 mV/h, Noise ≤ 0.02 mV |
| Column | OV-1701 Capillary Column (50 m × 0.32 mm × 0.5 µm), Max Temp 400 °C |
| Column Oven Dimensions | 240 × 210 × 240 mm |
| Temperature Resolution | 0.1 °C |
| Temperature Stability | ±0.1% of setpoint |
| Display | Integrated LCD with real-time temperature and status monitoring |
| Power Supply | 220 VAC, 50 Hz |
| Dimensions (H×W×D) | 500 × 550 × 500 mm |
| Compliance Standards | QB/T 2929, GB/T 10004–2008, YBB 00132002 |
| Brand | GBPI |
|---|---|
| Model | GC-9802B |
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Application Scope | General-purpose, with optimized configuration for residual solvent quantification |
| Oven Temperature Range | 40–400 °C |
| Temperature Ramp Rate | 0–40 °C/min |
| Cool-down Time | ~6 min (from 450 °C to 50 °C) |
| Carrier Gas Flow Control Range | 0–1200 mL/min |
| Carrier Gas Pressure Control Range | 0–970 kPa |
| Injector Maximum Temperature | 400 °C |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Detector | FID (Flame Ionization Detector), Mt ≤ 1×10⁻¹¹ g/s (n-hexadecane), Baseline Drift ≤ 0.02 mV/h, Noise ≤ 0.02 mV |
| Column | OV-1701 fused-silica capillary column (50 m × 0.32 mm ID × 0.5 µm film thickness), max. operating temperature 400 °C |
| Data System | Integrated chromatography data workstation with real-time acquisition, baseline correction, peak integration, calibration curve generation, PDF report export, and audit-trail-ready operation log |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Application Scope | General-Purpose Organic Solvent Analysis |
| Oven Temperature Range | 40–400 °C |
| Maximum Ramp Rate | 0–40 °C/min |
| Cooling Rate | 450 °C → 50 °C in ~6 min |
| Carrier Gas Flow Control Range | 0–1200 mL/min |
| Carrier Gas Pressure Control Range | 0–970 kPa |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Detector | FID (Hydrogen Flame Ionization Detector), Mt ≤ 1×10⁻¹¹ g/s (n-hexadecane), Baseline Drift ≤ 0.02 mV/h, Noise ≤ 0.02 mV |
| Column | OV-1701 Capillary Column (50 m × 0.32 mm ID × 0.5 µm film thickness), Max Temp: 400 °C |
| Display | Integrated LCD with Real-Time Temperature Monitoring |
| Data System | PC-Based Workstation with Chromatographic Acquisition & Quantitative Analysis Software |
| Compliance | QBT 2929, GB/T 10004–2008, YBB 00132002 |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | GC9802-K |
| Price Range | USD 14,000–21,000 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Environmental & Medical Device Testing |
| Detector | Hydrogen Flame Ionization Detector (FID) |
| Detection Limit | ≤3×10⁻¹² g/s (n-Hexadecane) |
| Baseline Noise | ≤2×10⁻¹⁴ A |
| Baseline Drift | ≤1×10⁻¹³ A/30 min |
| Column | EO-Specific Capillary Column (30 m × 0.32 mm × 0.5 µm) |
| Oven Temperature Range | 4 °C above ambient to 450 °C (1 °C increments) |
| Temperature Control Accuracy | ±0.1 °C |
| Temperature Gradient Uniformity | ±1% |
| Independent Temperature Zones | 6 |
| Programmable Temperature Ramping | 16 steps |
| Ramp Rate | 0.1–60 °C/min |
| Maximum Run Time | 6000 min |
| Injection Mode | Split/Splitless with Septum Purge |
| Optional Accessories | Zero-Air Generator (3 L/min, oil-free, dehydrated/deoiled), H₂ Generator (300 mL/min, 99.999% purity), High-Purity N₂ Supply (99.999%, cylinder + regulator), EO Certified Reference Standards |
| Software | Dual-Channel Chinese GUI Workstation with Instrument Control, Real-Time Chromatogram Display, Zoom/Pan Functionality, PDF Report Export, Audit-Trail-Ready Data Logging |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | GC9802-K1 |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Application Scope | General-Purpose Quantitative Analysis of Volatile Organic Compounds |
| Detector | Flame Ionization Detector (FID), Optional Alternative Detectors Available |
| Detection Limit | ≤3×10⁻¹² g/s (n-Hexadecane) |
| Baseline Noise | ≤2×10⁻¹⁴ A |
| Baseline Drift | ≤1×10⁻¹³ A/30 min |
| Column | EO-Specific Capillary Column (30 m × 0.32 mm × 0.5 µm), Optional Alternate Columns Supported |
| Autosampler | 20-Position Headspace Sampler |
| Oven Dimensions | 240 × 210 × 240 mm |
| Temperature Range | 4 °C above ambient to 450 °C (1 °C increments) |
| Temperature Control Accuracy | ±0.1 °C |
| Temperature Gradient Uniformity | ±1% |
| Independent Temperature Zones | 6 |
| Programmable Temperature Ramps | Up to 16 steps |
| Ramp Rate | 0.1–60 °C/min |
| Maximum Runtime Setting | 6000 min |
| Optional Accessories | Oil-Free Air Generator (3 L/min, with oil/water removal), Hydrogen Generator (300 mL/min, 99.999% purity), High-Purity Nitrogen Cylinder (99.999%, regulator included, locally sourced) |
| Calibration Standard | Certified Ethylene Oxide Reference Material |
| Data System | Dual-Channel Chinese-Language GC Workstation with Instrument Control, Real-Time Chromatogram Display, Zoom/Pan Functionality, PDF Report Export, and Manual Start Button Integration |
| Injection System | Split/Splitless Capillary Injector with Septum Purge Function |
| Safety Features | Dual-Layer Over-Temperature Protection (Software + Hardware), Advanced Acoustic Damping |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | GC9802-K2 |
| Price Range | USD 7,000–14,000 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-purpose |
| Detector | Flame Ionization Detector (FID), optional alternative detectors |
| Detection Limit | ≤3×10⁻¹² g/s (n-hexadecane) |
| Baseline Noise | ≤2×10⁻¹⁴ A |
| Baseline Drift | ≤1×10⁻¹³ A/30 min |
| Column | EO-specific capillary column (30 m × 0.32 mm × 0.5 µm), optional alternate columns |
| Headspace Sampler | 20-position |
| Oven Dimensions | 240 × 210 × 240 mm |
| Temperature Range | 4 °C above ambient to 450 °C (1 °C increments) |
| Temperature Control Accuracy | ±0.1 °C |
| Temperature Gradient Uniformity | ±1% |
| Independent Temperature Zones | 6 |
| Programmable Temperature Ramp Stages | 16 |
| Ramp Rate | 0.1–60 °C/min |
| Maximum Runtime Setting | 6000 min |
| Optional Air Generator | Oil-free, with oil/water removal, 3 L/min |
| Optional H₂ Generator | 300 mL/min, purity ≥99.999% |
| Carrier Gas | High-purity nitrogen (99.999%), supplied via cylinder with regulator (local procurement) |
| Certified EO Standard | Included |
| Data System | Dual-channel Chinese-language chromatography workstation with instrument control |
| Injection System | Split/splitless capillary inlet with septum purge function |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | GC9802-UO |
| Price Range | USD 7,000 – 14,000 |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Primary Application Field | Environmental & Medical Device Residue Testing |
| Detector | Flame Ionization Detector (FID), optional alternative detectors available |
| Detection Limit | ≤3×10⁻¹² g/s (n-hexadecane) |
| Baseline Noise | ≤2×10⁻¹⁴ A |
| Baseline Drift | ≤1×10⁻¹³ A/30 min |
| Column | EO-specific capillary column (30 m × 0.32 mm × 0.5 µm), optional columns supported |
| Headspace Sampler | 20-position automated unit |
| Oven Dimensions | 240 × 210 × 240 mm |
| Temperature Range | 4 °C above ambient to 450 °C (1 °C increments) |
| Temperature Control Accuracy | ±0.1 °C |
| Temperature Gradient Uniformity | ±1% |
| Independent Temperature Zones | 6 |
| Programmed Temperature Ramping | Up to 16 steps |
| Ramp Rate | 0.1–60 °C/min |
| Maximum Runtime Setting | 6000 min |
| Optional Accessories | Oil-free air generator (3 L/min, with oil/water removal) |
| Injection System | Split/splitless capillary inlet with septum purge |
| Data System | Dual-channel Chinese-language chromatography workstation with instrument control, real-time chromatogram display, zoom/pan functionality, automated report generation (PDF export), and manual hardware start trigger |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | GC-4008B |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Application Domain | Coal Mining Safety & Spontaneous Combustion Monitoring |
| Detection Systems | TCD, Dual FID, ECD, FPD |
| Column Configuration | Four Dedicated Capillary/Packed Columns |
| Temperature Program | 10-Stage Programmable Ramp |
| Carrier Gases | Helium (TCD), Hydrogen/Air (FID), Nitrogen (ECD/FPD) |
| Minimum Detectable Concentrations | CO, C₂H₂ ≤ 0.5 ppm |
| [Brand | Chrom |
|---|---|
| Origin | Zhejiang, China |
| Model | GC-5190PDD |
| Instrument Type | Laboratory Gas Chromatograph |
| Application | Ultra-High-Purity Gas Analysis |
| Oven Temperature Range | 4°C above ambient to 450°C |
| Max. Ramp Rate | 60°C/min |
| Carrier Gas Flow Control Range | 30–35 mL/min |
| Carrier Gas Pressure Control Range | 0.35–0.55 MPa |
| Injector Max. Temp. | 450°C |
| Injector Pressure Setting Range | 0–100 psi |
| Injector Total Flow Setting Range | 0–1000 mL/min |
| PDHID Detection Limit (CH₄) | ≤3.5×10⁻¹³ g/mL |
| PDHID Dynamic Linear Range | ≥10⁷ |
| PDHID Noise | <0.1 pA |
| PDHID Drift | ≤1.0 pA/30 min |
| PDHID Repeatability (CH₄) | ≤3.0% RSD |
| Column Oven Temp. Stability | ±0.02°C |
| Programmable Temperature Steps | 9 ramps / 10 plateaus |
| Max. Program Duration | 9999.9 min] |