Chromatography Instruments
Filter
Showing 451–480 of 701 results
| Brand | POSTNOVA |
|---|---|
| Origin | Germany |
| Model | CF2000 |
| Maximum Rotational Speed | 6500 rpm |
| Separation Mechanism | Size-based and Density-based Fractionation |
| Application Focus | Nanomaterial Sizing, Branched vs. Linear Polymer Analysis in Aqueous and Organic Solvents |
| Instrument Type | Centrifugal Field Flow Fractionation System |
| Brand | POSTNOVA |
|---|---|
| Origin | Germany |
| Model | EAF2000 |
| Instrument Type | Asymmetric Flow Field-Flow Fractionation (AF4) with Integrated Electric Field-Flow Fractionation (EF4) |
| Operating Solvent Compatibility | Aqueous only |
| Channel Configuration | Dual-field, orthogonal separation channel module |
| Regulatory Compliance | Designed for GLP/GMP environments |
| Brand | POSTNOVA |
|---|---|
| Origin | Germany |
| Model | GF2000 GS |
| Separation Mode | Gravitational Sedimentation FFF |
| Core Technology | SPLITT (Split Flow Thin Cell Fractionation) |
| Channel Configuration | Horizontal, Membrane-Free, Stationary-Phase-Free |
| Applicable Sample States | Aqueous or Low-Viscosity Suspensions |
| Typical Particle Size Range | 10 nm – 100 µm (dependent on density contrast and flow conditions) |
| Max. Sample Concentration | ≤ 5% w/v (varies by particle density and dispersibility) |
| Flow Rate Range | 0.1–5.0 mL/min (per inlet) |
| Compliance | Designed for GLP-compliant laboratories |
| Brand | POSTNOVA |
|---|---|
| Origin | Germany |
| Model | SC2000 |
| Instrument Type | Ambient-Temperature GPC System |
| Pump Flow Range | 0.001–9.995 mL/min |
| Pump Pressure Limit | 40 MPa |
| RI Detector Drift | 1 × 10⁻⁷ RIU/h |
| RI Detector Cell Volume | 8 µL |
| UV Detector Wavelength Range | 190–800 nm |
| UV Detector Noise | ±0.3 × 10⁻⁵ AU |
| Column Oven Temperature Range | +5 °C to +90 °C |
| Brand | POSTNOVA |
|---|---|
| Origin | Germany |
| Model | TF 2000 |
| Field Type | Thermal |
| Instrument Category | Field Flow Fractionation (FFF) |
| Regulatory Class | Imported Analytical Instrument for Macromolecular & Nanoparticle Characterization |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PRE-2000 |
| Application Level | Industrial-Scale Preparative |
| Instrument Type | High-Pressure Preparative LC |
| Flow Rate Range | 0.1–100 mL/min |
| Flow Accuracy | ±1.0% |
| Flow Precision | ≤0.2% RSD |
| Flow Reproducibility | ≤0.2% RSD |
| Maximum Pressure | 5000 psi |
| Wavelength Range | 190–800 nm (±1 nm) |
| Wavelength Reproducibility | ±0.1 nm |
| Baseline Noise | ≤0.15 × 10⁻⁵ AU |
| Data Acquisition Rate | 100 Hz |
| Pump Configuration | Dual Isocratic or Gradient Capable |
| Gradient Composition Range | 0–100% B |
| Auto-Cleaning Pump Head | Integrated |
| Maintenance Interval | ≥6 months under continuous operation |
| Brand | Prin-Cen |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic |
| Model | ELSpe-2 |
| Pricing | Upon Request |
| Instrument Type | Ultra-High-Performance Liquid Chromatograph (UHPLC) |
| Application Scope | General-Purpose |
| Flow Rate Range | 0.001–10.000 mL/min |
| Maximum Operating Pressure | 50 MPa |
| Autosampler Capacity | 120 positions × 2 mL vials |
| Injection Volume Range | 1–50 µL |
| Column Oven Temperature Range | (Ambient + 10 °C) to 60 °C |
| UV-Vis Detection Wavelength Range | 190–700 nm |
| Data Acquisition Frequency | 50 Hz |
| Brand | PUREN |
|---|---|
| Model | PAGM |
| Instrument Type | Online Ion Chromatograph with Integrated Aerosol Sampling & Pre-treatment System |
| Origin | Shandong, China |
| Manufacturer | PUREN Instrument Co., Ltd. |
| Pump Pressure Rating | 36 MPa |
| Flow Rate Range | 0–9.999 mL/min |
| Eluent Flow Rate | 1.0 mL/min |
| Max Operating Pressure | 15 MPa |
| Operating Temperature Range | 14–35 °C |
| Temperature Reproducibility | ±0.01 °C |
| Eluent Concentration Range | 1.0–5.0 mM |
| Brand | PUREN |
|---|---|
| Model | PIC-10 Dual-System |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Benchtop Ion Chromatograph |
| Application Scope | General-Purpose Anion/Cation Analysis |
| Pump Max Pressure | 0–42.0 MPa (Stainless Steel), 0–36 MPa (PEEK) |
| Flow Rate Range | 0.001–9.999 mL/min (0.001 mL/min increments) |
| Eluent Flow Rate | 0.7–1.5 mL/min |
| Max Operating Pressure | 10 MPa (1500 psi) |
| Temperature Control Range | 5–65 °C |
| Temperature Stability | ±0.004 °C |
| Eluent Concentration Range | 1.92–4.8 mM |
| Brand | PUREN |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | PIC-10 Dual-System Fully Automated |
| Instrument Type | Laboratory Benchtop |
| Application Scope | Universal |
| Pump Maximum Pressure | 0–42.0 MPa (stainless steel), 0–36 MPa (PEEK) |
| Flow Rate Range | 0.001–9.999 mL/min (adjustable in 0.001 mL/min increments) |
| Eluent Flow Rate | 0.7–1.5 mL/min |
| Max Operating Pressure | 10 MPa (1500 psi) |
| Temperature Control Range | 5–65 °C |
| Temperature Reproducibility | ±0.004 °C |
| Eluent Concentration Range | 1.92–4.8 mM |
| Brand | PUREN |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Benchtop Ion Chromatograph |
| Application Scope | General-Purpose Anion/Cation Analysis |
| Maximum Pump Pressure | 0–42.0 MPa (Stainless Steel), 0–35 MPa (PEEK) |
| Flow Rate Range | 0.001–9.999 mL/min (0.001 mL/min increments) |
| Eluent Flow Rate | 0.7–1.5 mL/min |
| Max System Operating Pressure | 10 MPa (1500 psi) |
| Column Oven Temperature Range | 5–65 °C |
| Eluent Concentration Range | 1.92–4.8 mM |
| Brand | PUREN |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic Laboratory Instrument |
| Model | PIC-10A Dual-System |
| Instrument Type | Benchtop Laboratory Ion Chromatograph |
| Application Scope | General-Purpose Quantitative Analysis of Inorganic Ions |
| Pump Max Pressure | 0–42.0 MPa (Stainless Steel), 0–35 MPa (PEEK) |
| Flow Rate Range | 0.001–9.999 mL/min (0.001 mL/min increments) |
| Eluent Flow Rate | 0.7–1.5 mL/min |
| Maximum Operating Pressure | 10 MPa (1500 psi) |
| Operating Temperature Range | 5–65 °C |
| Temperature Reproducibility | ±0.1 °C |
| Eluent Concentration Range | 1.92–4.8 mM |
| Brand | PUREN |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Benchtop IC System |
| Configuration | Dual-Channel Simultaneous Anion/Cation Analysis |
| Pump Material Options | Stainless Steel (Max. 42.0 MPa) / PEEK (Max. 35 MPa) |
| Flow Rate Range | 0.001–9.999 mL/min (0.001 mL/min increments) |
| Eluent Flow Rate | 0.7–1.5 mL/min |
| Max. Operating Pressure | 10 MPa (1500 psi) |
| Column & Detector Oven Temperature Range | 5–65 °C |
| Temperature Stability | ±0.004 °C |
| Eluent Concentration Range | 1.92–4.8 mM |
| Detection Modes | Conductivity (dual-channel), Amperometric (optional), UV-Vis (optional) |
| Integrated Components | Built-in degasser (pre- and post-suppressor), CO₂ removal module, electrochemical suppressor (continuous regeneration), column switching valve, auto-sampler interface, embedded high-resolution LCD control panel with real-time chromatogram display |
| Brand | PUREN |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | PIC-10A (Dual-System Autosampler Configuration) |
| Detection Modes | Conductivity Detection (Standard), Optional Pulsed Amperometric Detection (PAD), DC Amperometric Detection, Integral Amperometric Detection, Differential Pulse Voltammetry |
| Anion Separation Range | F⁻, Cl⁻, NO₂⁻, NO₃⁻, SO₄²⁻, Br⁻, PO₄³⁻, ClO₂⁻, ClO₃⁻, BrO₃⁻ |
| Cation Separation Range | Li⁺, Na⁺, NH₄⁺, K⁺, Ca²⁺, Mg²⁺, Sr²⁺, Ba²⁺ |
| Detector | Dual Conductivity Detector (Simultaneous Anion/Cation Monitoring) |
| Pump System | Dual Microprocessor-Controlled Double-Plunger Reciprocating Pumps |
| Flow Pulsation | Minimized via Intelligent Flow Algorithm |
| Gradient Capability | Binary to Quaternary Gradient Elution |
| Fluidic Path Materials | PEEK (Imported, Acid/Base/100% Organic Solvent Compatible) |
| Suppressor | Auto-Regenerating Membrane Suppressor (pH 0–14, On-Line Regeneration, Low Background Conductivity, Maintenance-Free Operation) |
| Thermostat | Integrated Internal Column & Detector Thermostat (Patent No. 200820019630.3) |
| Data Acquisition | High-Precision Digital-to-Analog Conversion |
| Interface | USB (Workstation Communication), RS-232/485 (Pump & Peripheral Control) |
| Autosampler | Electric-Valve Full-Loop Injection, Trace-Sample Compatible, Residual-Free, High Reproducibility (RSD < 1.2%) |
| Software Functions | Real-Time Parameter Remote Control, Baseline Subtraction, Automatic Peak Integration, Negative Peak Recognition, Fault Diagnostics & Instrument State Monitoring, Report Generation (PDF/CSV/XLS), Audit-Trail Ready Data Logging |
| Brand | PUREN |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Benchtop Ion Chromatograph |
| Application Scope | Universal (Anions & Cations) |
| Maximum Pump Pressure | 0–42.0 MPa (Stainless Steel), 0–36 MPa (PEEK) |
| Flow Rate Range | 0.001–9.999 mL/min (0.001 mL/min increments) |
| Eluent Flow Rate | 0.7–1.5 mL/min |
| Max System Operating Pressure | 10 MPa (1500 psi) |
| Column Oven Temperature Range | 5–65 °C |
| Temperature Reproducibility | ±0.004 °C |
| Eluent Concentration Range | 1.92–4.8 mM |
| Brand | PUREN |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | PIC-20 |
| Instrument Type | Laboratory Benchtop |
| Application Scope | General-Purpose Ion Analysis |
| Pump Maximum Pressure | 0–42.0 MPa (stainless steel), 0–35 MPa (PEEK) |
| Flow Rate Range | 0.001–9.999 mL/min (adjustable in 0.001 mL/min increments) |
| Eluent Flow Rate | 0.7–1.5 mL/min |
| System Operating Pressure Limit | 10 MPa (1500 psi) |
| Column Oven Temperature Range | 5–65 °C |
| Temperature Stability | ±0.004 °C |
| Eluent Concentration Range | 1.92–4.8 mM |
| Brand | PUREN |
|---|---|
| Model | PIC-20 |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Class | Laboratory Benchtop Ion Chromatograph |
| Application Scope | General-Purpose Anion/Cation Analysis |
| Maximum Pump Pressure | 0–36.0 MPa |
| Flow Rate Range | 0.001–9.999 mL/min |
| Eluent Flow Rate | 0.7–1.5 mL/min |
| Max Operating Pressure | 10 MPa (1500 psi) |
| Operating Temperature Range | 5–65 °C |
| Temperature Reproducibility | ±0.1 °C |
| Eluent Concentration Range | 1.92–4.8 mM |
| Detector Configuration | Dual Conductivity Detectors + Optional Amperometric Detector |
| Column Oven | Integrated Peltier-heated Column/Suppressor Compartment (Patent No. ZL200820019630.3) |
| Data Storage | Local SSD + Cloud Synchronization |
| Connectivity | USB 2.0, Wi-Fi, Mobile App Remote Control (iOS/Android) |
| Compliance | Designed for ISO/IEC 17025 environments |
| Brand | PUREN |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | PIC-30 |
| Instrument Type | Laboratory Benchtop System |
| Application Scope | General-Purpose Anion/Cation Analysis |
| Maximum Pump Pressure | 36 MPa |
| Flow Rate Range | 0.001–9.999 mL/min |
| Eluent Flow Rate Range | 0.001–9.999 mL/min |
| Maximum Operating Pressure | 10 MPa |
| Operating Temperature Range | 5–65 °C |
| Temperature Reproducibility | ±0.04 °C |
| Eluent Concentration Range | 0–20 mM |
| Detector Options | Dual-Channel Conductivity Detector / Single-Channel Voltammetric Detector / Dual-Channel UV-Vis Detector |
| Fluidic Path | All-PEEK Non-Metallic Flow Path |
| Integrated Components | Embedded Chromatography Workstation, Auto-Sampler Interface, Onboard Dilution Module, Eluent Generator Compatibility (Optional), Internal Degasser, CO₂ Suppressor, Column Oven with Integrated Conductivity Cell & Suppressor |
| Brand | PUREN |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Portable Ion Chromatograph |
| Model | PIC-60 |
| Pump Pressure Rating | 42 MPa |
| Flow Rate Range | 0.001–9.999 mL/min |
| Eluent Flow Rate Range | 0.001–9.999 mL/min |
| Maximum Operating Pressure | 42 MPa |
| Operating Temperature Range | 0–65 °C |
| Temperature Reproducibility | ±0.01 °C |
| Eluent Concentration Range | 0–80 mmol/L |
| Brand | PUREN |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | PIC-80 |
| Instrument Type | Laboratory Benchtop |
| Application Scope | General-Purpose |
| Pump Max Pressure | 0–42.0 MPa (Stainless Steel) / 0–36 MPa (PEEK) |
| Flow Rate Range | 0.001–9.999 mL/min |
| Eluent Flow Rate | 0.7–1.5 mL/min |
| Maximum Operating Pressure | 10 MPa (1500 psi) |
| Operating Temperature Range | 5–65 °C |
| Temperature Reproducibility | ±0.004 °C |
| Eluent Concentration Range | 1.92–4.8 mM |
| Brand | PUREN |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | PIC-80B |
| Instrument Type | Laboratory |
| Application Scope | General-purpose |
| Pump Pressure Rating | 0–42.0 MPa (stainless steel), 0–36 MPa (PEEK) |
| Flow Rate Range | 0.001–9.999 mL/min |
| Eluent Flow Rate | 0.7–1.5 mL/min |
| Max Operating Pressure | 10 MPa |
| Operating Temperature Range | 5–65 °C |
| Temperature Reproducibility | ±0.004 °C |
| Eluent Concentration Range | 1.92–4.8 mM |
| Brand | PUREN |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Online Analyzer |
| Application | General-Purpose Environmental & Industrial Process Monitoring |
| Pump Pressure Rating | 0–42.0 MPa (Stainless Steel) / 0–35 MPa (PEEK) |
| Flow Rate Range | 0.001–9.999 mL/min (0.001 mL/min increments) |
| Eluent Flow Rate | 0.7–1.5 mL/min |
| Max Operating Pressure | 10 MPa (1500 psi) |
| Temperature Range | 5–65 °C |
| Temperature Reproducibility | ±0.1 °C |
| Eluent Concentration Range | 1.92–4.8 mM |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | PuriMaster-3500C1 |
| Application Level | Laboratory-grade |
| Instrument Type | High-Pressure Preparative Liquid Chromatograph |
| Pump Pressure Rating | 300 bar |
| Flow Rate Range | 0–50 mL/min per pump |
| Flow Stability | ≤2% RSD |
| UV-Vis Detection Wavelength Range | 190–850 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | 0.2 nm |
| Detector Light Source | Dual-lamp system (Deuterium + Tungsten) |
| Fraction Collection | 6-port switching valve (standard) |
| Auto-sampler Quantitative Loop | 3 mL |
| Gradient Capability | Binary high-pressure mixing |
| Brand | Purkinje |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | GC1100 |
| Temperature Control Range | Ambient +6°C to 399°C |
| Oven Ramp Rate | 0–30°C/min |
| Carrier Gas Flow Range | 0–1200 mL/min |
| Carrier Gas Pressure Range | 0–970 kPa |
| Injector Maximum Temperature | 200°C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Column Oven Temperature Accuracy | ±0.1°C |
| Column Oven Temperature Gradient | ±1.5% |
| TCD Sensitivity | ≥4000 mV·mL/mg (n-hexadecane) |
| TCD Noise | ≤0.04 mV |
| TCD Baseline Drift | ≤0.2 mV/30 min |
| FID Detection Limit | ≤8×10⁻¹² g/s (n-hexadecane) |
| FID Noise | ≤0.02 mV |
| FID Baseline Drift | ≤0.2 mV/30 min |
| Dimensions (L×W×H) | 562×550×492.5 mm |
| Weight | 44 kg |
| Brand | Tlyon (Distributor) |
|---|---|
| Origin | Hungary |
| Manufacturer | RotaChrom GmbH |
| Instrument Type | Benchtop Centrifugal Partition Chromatograph |
| Software Components | CPC Simulator, CPC Visualizer |
| Flow Rate Range | 0.1–25 mL/min |
| Sample Load Capacity | 10 mg–5 g per cycle |
| Detection | UV-Vis (200–600 nm), optional ELSD/MS interface |
| Fraction Collection | Automated, timed or peak-triggered |
| Compliance | GLP-ready architecture, audit trail-capable software logging, ISO/IEC 17025-aligned operation |
| Origin | Netherlands |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ROXY |
| Pricing | Available Upon Request |
| Potentiostat | ROXY Potentiostats DCC |
| Autosampler | AS 110 (Cool, Micro, 10-Position Vial) |
| LC Pump | LC 110 |
| Reactor Cell | Integrated with Multi-Electrode Detection (MD) and Gas Collection (GC) Electrodes |
| Organizer | OR 110 |
| Software | Clarity Chromatography Data System |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | ScalePuri-50 |
| Application Level | Pilot-Scale Laboratory |
| Instrument Type | High-Pressure Preparative Liquid Chromatograph |
| Maximum Flow Rate | 0–200 mL/min |
| Flow Accuracy | ±2.0% |
| Pressure Rating | Up to 20 MPa |
| Wavelength Range | 190–850 nm |
| Wavelength Accuracy | ±1 nm |
| Spectral Bandwidth | 8 nm |
| Baseline Noise | ±0.2 mAU (at 254 nm) |
| Baseline Drift | 0.5 mAU (at 254 nm) |
| Detection Modes | Quadruple Wavelength Simultaneous Monitoring |
| Column Compatibility | Axial Compression Columns (DAC50, ID 10–50 mm) |
| Fraction Collection | Volume-, Peak-, Time-, or Threshold-Triggered |
| Software Compliance | 21 CFR Part 11 Ready, Audit Trail, Electronic Signatures, User & Role Management |
| Regulatory Alignment | Designed for GLP/GMP environments, supports IQ/OQ/PQ validation |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Model | BioPhase 8800 + NFD |
| Instrument Type | Capillary Electrophoresis (CE) System |
| Detector | Native Fluorescence Detector (NFD) |
| Sample Format | ANSI/SLAS-compliant 96-well plate |
| CE Modes Supported | CE-SDS, cIEF, CZE |
| Regulatory Compliance | Designed for GLP/GMP environments |
| Linear Dynamic Range | >4 decades |
| Correlation Coefficient (R²) | ≥0.995 |
| Sensitivity | Sub-μg/mL for native protein detection |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Model | SCIEX BioPhase™ 8800 |
| Instrument Type | Capillary Electrophoresis (CE) System |
| Channel Capacity | 8 parallel capillaries |
| Detection Modes | UV-Vis and Laser-Induced Fluorescence (LIF) |
| Sample Format | ANSI/SLAS-compliant 96-well plate |
| Application Focus | Biopharmaceutical characterization (mAb, bispecifics, ADCs, gene therapy vectors) |
| Sensitivity | ≤1 µg/mL (CE-SDS), linear dynamic range >4 orders of magnitude (R² > 0.995) |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Model | C100 HT |
| Instrument Type | Capillary Electrophoresis (CE) |
| Sample Type | Organic Analysis |
| Voltage Range | 1–25 kV |
| Detection Modes | UV and Laser-Induced Fluorescence (LIF) |
| Injection Method | Pressure-driven |
| Pressure Range | 5–100 psi |
| Cooling System | Liquid-based Temperature Control |
| Operating Mode | Constant Current |