Chromatography Instruments
Filter
Showing 481–510 of 1485 results
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | GC9802-Y |
| Application Scope | General-purpose EO residue testing in medical devices and packaging |
| Detector | Flame Ionization Detector (FID), optional alternative detectors available |
| Detection Limit | ≤3×10⁻¹² g/s (n-hexadecane) |
| Baseline Noise | ≤2×10⁻¹⁴ A |
| Baseline Drift | ≤1×10⁻¹³ A/30 min |
| Column | 30 m × 0.32 mm × 0.5 µm EO-specific capillary column (optional columns available) |
| Headspace Autosampler | 20-position |
| Oven Dimensions | 240 × 210 × 240 mm |
| Temperature Range | 4 °C above ambient to 450 °C (1 °C increments) |
| Temperature Control Accuracy | ±0.1 °C |
| Temperature Gradient Uniformity | ±1% |
| Independent Temperature Zones | 6-channel oven, inlet, detector, and auxiliary zones |
| Programmed Temperature Ramp | Up to 16 steps, ramp rate 0.1–60 °C/min |
| Maximum Runtime Setting | 6000 min |
| Carrier Gas | High-purity nitrogen (99.999%, supplied externally) |
| Hydrogen Generator (optional) | 300 mL/min, purity ≥99.999% |
| Air Generator (optional) | Oil-free, dehydrated & deoiled, 3 L/min |
| Injection System | Split/splitless capillary injector with septum purge |
| Software | Dual-channel Chinese-language chromatography workstation with instrument control, real-time plotting, peak integration, calibration curve generation, PDF report export, and audit-ready data logging |
| Brand | LABORAT |
|---|---|
| Model | LYG-1020 |
| Origin | Hebei, China |
| Instrument Type | High-Temperature GPC System |
| UV Detector Wavelength Range | 190–700 nm |
| Flow Rate (Standard) | 0.01–50.00 mL/min |
| Flow Rate (Optional High-Precision) | 0.001–10.000 mL/min |
| Auto-Sampler Volume (Standard) | 10 mL loop |
| Column Dimensions (Standard) | 25 × 400 mm |
| Fraction Collector | 5-position valve-based system (customizable) |
| Detection Light Source | Deuterium/Tungsten dual-lamp assembly |
| Software | Integrated industrial PC with audit-trail-enabled chromatography control software |
| Brand | GERSTEL |
|---|---|
| Origin | Germany |
| Model | MCS |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Domain | Petrochemical Industry |
| Modular Architecture | Fully Compatible with Agilent GC Platforms |
| Integrated Cryogenic Trapping | Yes |
| EPC-Controlled Column Switching & Flow Management | Yes |
| Software Control | MAESTRO v2.5+ (FDA 21 CFR Part 11 Compliant) |
| Regulatory Compliance | ASTM D6729, ISO 15503, USP <467>, GLP/GMP-Auditable Audit Trail |
| Sample Introduction Compatibility | CIS-4, MPS XT, TDS3, ODP, PFC |
| Brand | GAOMAI |
|---|---|
| Origin | Beijing, China |
| Model | GM Explosion-Proof Analytical Shelter |
| Instrument Type | Portable Gas Chromatograph System Enclosure |
| Application Scope | General-purpose Industrial Process Gas Analysis |
| Explosion Protection Rating | Exd II BT1 to Exd II CT6 (customizable per user specification) |
| Ambient Temperature Control Capability | Integrated HVAC with temperature stabilization |
| Humidity & Dust Protection | IP56-rated enclosure |
| Internal Overpressure Maintenance | 30–100 Pa (gauge) |
| Alarm Function | Audible and visual alarm triggered by hazardous gas concentration exceedance |
| Power Supply | 220 VAC ±10%, 50 Hz |
| Compliance | Designed to meet IEC 60079-1, GB 3836.1–2021, and ISO 8573-1 for compressed air quality in analytical service lines |
| Structural Certification | Fabricated per ASME BPVC Section VIII Div. 1 (optional) |
| [Brand | Golden Promise |
|---|---|
| Origin | Shandong, China |
| Model | GC-2011 |
| Detection Principles | Dual-channel gas chromatography with simultaneous TCD and FID detection |
| Temperature Control | 8°C above ambient to 420°C (±0.1°C ≤200°C |
| Programmed Temperature Ramping | 8-step linear ramping, 0.1–30°C/min (0.1°C increment) |
| Detector Sensitivity | FID: ≤1×10⁻¹¹ g/s (benzene) |
| TCD | ≥3500 mV·mL/mg (benzene) |
| Column Compatibility | Dual-inlet system — packed column inlet (TCD-optimized) + dedicated split/splitless capillary inlet with tail-purge |
| Dimensions | 540 × 455 × 465 mm |
| Weight | 50 kg |
| Power | AC 220 V ±10%, 50 Hz, ~2 kW] |
| [Brand | Golden Promise |
|---|---|
| Origin | Shandong, China |
| Model | GC-7890 |
| Instrument Type | Online Gas Chromatograph |
| Application Field | General-Purpose Industrial Process Analysis |
| Temperature Control Range | 5 °C to 450 °C |
| Oven Temperature Stability | ±0.1 °C (≤200 °C), ±0.2 °C (>200 °C) |
| Ramp Rate | 1–30 °C/min |
| Cooling Rate | Variable, enabled by intelligent back-door temperature modulation |
| Carrier Gas Flow Control | Digital mass flow control (MFC) compatible with He, H₂, N₂ |
| Carrier Gas Pressure Control | Electronic pressure control (EPC) with 0–1000 kPa range |
| Injector Max Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–1000 kPa |
| Total Injector Flow Setting Range | 0–200 mL/min |
| Detectors | FID (MDL ≤1×10⁻¹¹ g/s benzene), TCD (Sensitivity ≥3000 mV·mL/mg benzene), optional ECD/FPD/NPD support |
| Column Compatibility | Dual packed-column inlets + dedicated split/splitless capillary inlet with makeup gas and tail-purge capability |
| Thermal Programming | 5-step programmable ramping |
| Safety Features | Power-fail memory, overtemperature cutoff, carrier gas failure protection, real-time fault diagnostics] |
| Brand | Golden Promise |
|---|---|
| Model | GC-8890 |
| Type | Online Gas Chromatograph |
| Origin | Shandong, China |
| Instrument Category | Domestic |
| Control Architecture | Full EPC/EFC (Optional) |
| Temperature Programming | 0.1–80 °C/min |
| Column Oven Cooling | 350 °C → ambient in ≤3 min |
| Detection Compatibility | Simultaneous FID & TCD operation |
| Injector Precision | RSD ≤2% (n=6) |
| Flow Control Resolution | 0.01 sccm / 0.01 kPa |
| Temperature Stability | ±0.1 °C |
| External Event Channels | 8 |
| Auto-Ignition | Hydrogen/Air intelligent sequencing with flame-out detection |
| Dual Back-Door Mechanism | Motorized, temperature-responsive actuation |
| Safety Protections | Overtemperature cutoff, TCD filament safeguard, gas-loss alarm, power-fail retention, short/open circuit diagnostics |
| Compliance Framework | Designed for GLP-compliant laboratories |
| Brand | Golden Promise |
|---|---|
| Model | GC-8890SD |
| Origin | Shandong, China |
| Weight | 60 kg |
| Dimensions (L×W×H) | 565 × 505 × 500 mm |
| Detection Limit | ≤1×10⁻¹² g/s (n-C₁₆, FID) |
| Connectivity | 10/100M Ethernet (IEEE 802.3) |
| Column Oven Temp Range | 5–400 °C (0.1 °C increment, ±0.1 °C stability) |
| Max Heating Rate | 40 °C/min (programmable up to 20 steps) |
| Cooling Rate | ≤3 min (200 → 100 °C) |
| Detector Options | FID, TCD (configurable) |
| Power Supply | 220 V ±10%, 50 Hz ±0.5 Hz, 2500 W max |
| [Brand | Golden Promise |
|---|---|
| Model | LC-3000 |
| Pump Type | Dual-plunger reciprocating high-pressure gradient system |
| Max Pressure | 42 MPa (P3110), 30 MPa (P3120) |
| Flow Range | 0.002–9.998 mL/min (P3110), 0.01–49.99 mL/min (P3120) |
| Flow Accuracy | ±2% (2–5% of set flow, MeOH/H₂O 80:20) |
| Flow RSD | <0.1% |
| Detector | UV/VIS (UV3000) |
| Wavelength Range | 190–700 nm |
| Wavelength Accuracy | ±2 nm |
| Wavelength Repeatability | 0.4 nm |
| Scan Modes | Programmable stop-flow scanning (start/end/step configurable) |
| Absorbance Range | 0–2 AU |
| Baseline Noise | 2×10⁻⁵ AU/h (1 mL/min, MeOH/H₂O 80:20, 254 nm) |
| Baseline Drift | 15×10⁻⁵ AU/h (1 mL/min, MeOH/H₂O 80:20, 254 nm) |
| Time Constants | 0.1/0.2/0.5/1/2/5/10 s |
| Lamp Options | Deuterium (standard), Tungsten (optional) |
| Display | 320×240 dot-matrix LCD with adjustable blue backlight |
| Communication | RS-232 interface |
| Power | 220 V ±10%, 50 Hz (pump: 400 W |
| detector | 60 W) |
| Dimensions (D×H×W) | 398×149×267 mm |
| Weight | 14 kg |
| GLP Features | Lamp operating time logging, lamp cycle count, lamp replacement history, serial number traceability] |
| [Brand | Golden Promise |
|---|---|
| Model | LC-3000 |
| Type | HPLC-Based Melamine Quantification System |
| Origin | Shandong, China |
| Instrument Class | Benchtop Liquid Chromatograph for Targeted Small-Molecule Analysis |
| Detection Principle | UV-Vis Absorption at 240 nm with Diode Array or Fixed-Wavelength UV Detector |
| Column Compatibility | Reversed-Phase C8/C18 (e.g., 250 mm × 4.6 mm, 5 µm) |
| Flow Rate Range | 0.1–2.0 mL/min |
| Column Oven Temperature Control | Ambient to 60 °C |
| Sample Injection Volume | 5–100 µL (manual or optional autosampler-ready) |
| Regulatory Alignment | Designed for ASTM D7968-19, ISO 17394:2015, and GB/T 22388–2008 compliant workflows |
| Software | PC-based chromatography data system (CDS) with peak integration, calibration curve generation (linear/non-linear), audit trail, and report export (PDF/CSV)] |
| Brand | Golden普 |
|---|---|
| Model | GC-2011 (New Generation) |
| Origin | Shandong, China |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-purpose |
| Oven Temperature Range | Ambient +8°C to 420°C |
| Temperature Control Accuracy | ±0.1°C (≤200°C), ±0.2°C (>200°C) |
| Programmable Temperature Ramping | 5-stage linear ramping |
| Ramp Rate | 1–30°C/min (0.1°C increment) |
| Cooling Rate | 350°C → 100°C in ≤3.5 min |
| Detector Options | FID (Mf ≤2×10⁻¹¹ g/s for benzene) or TCD (S ≥3000 mV·mL/mg for benzene) |
| Dimensions | 540 × 470 × 460 mm |
| Weight | 50 kg |
| Power Supply | AC 220 V ±10%, 50 Hz, 2 kW |
| Brand | Golden普 |
|---|---|
| Model | GC-7890A |
| Type | Laboratory Gas Chromatograph |
| Origin | Shandong, China |
| Temperature Control Range | Ambient +5°C to 400°C (adjustable in 0.1°C increments) |
| Ramp Rate | 0.1–40°C/min (0.1°C increment) |
| Cooling Rate | 450°C → 50°C in ≤6 min |
| Carrier Gas Flow Range & Control | 0–1200 mL/min (7-step programmable) |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Max Operating Temperature | 400°C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Column Oven Temperature Accuracy | ±0.1°C |
| Temperature Uniformity (100–360°C) | ±1°C |
| FID Sensitivity | ≤3×10⁻¹² g/s (benzene, CS₂) |
| FID Baseline Noise | ≤3×10⁻¹⁴ A |
| FID Drift | ≤5×10⁻¹³ A/30 min |
| FID Linear Dynamic Range | ≥10⁶ |
| Dimensions (W×D×H) | 660×460×465 mm |
| Weight | 60 kg |
| Power Supply | AC 220 V ±10%, 2200 W max |
| Brand | Golden普 |
|---|---|
| Origin | Shandong, China |
| Model | OG-2000VA |
| Instrument Type | Portable Gas Chromatograph |
| Application Field | Petroleum & Petrochemical Industry |
| Oven Temperature Range | Ambient +4°C to 450°C |
| Oven Ramp Rate | 0.1–40°C/min |
| Oven Cool-down Rate | 400°C → 50°C in ~6 min |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | Up to 900 kPa |
| Injector Maximum Operating Temperature | 400°C |
| Injector Pressure Setting Range | Up to 900 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| FID Detection Limit (Hydrocarbons) | 0.001 mg HC/g rock |
| FID Baseline Drift | < 0.1 mV/30 min |
| FID Linear Dynamic Range | 10⁶ |
| FID Temperature Stability | 360 ± 0.5°C |
| Pyrolysis Furnace Temperature Stability | 600 ± 0.5°C |
| Programmable Pyrolysis Cycles | 4 (Source Rock, Reservoir Rock, Thermal Simulation, User-Defined) |
| Ramp Linearity Deviation | < 0.5°C/min |
| Brand | GOW-MAC |
|---|---|
| Origin | USA |
| Model | GOW-MAC 1300 |
| Instrument Type | Laboratory Gas Chromatograph |
| Temperature Control Range | 0–450 °C |
| Ramp Rate | 0.1–40 °C/min |
| Cooling Rate | 450 °C to 10 °C in ~5 min |
| Carrier Gas Flow Range & Control | 0–30 mL/min |
| Carrier Gas Pressure Range & Control | 0–100 kPa |
| Injector Max Operating Temperature | 450 °C |
| Injector Pressure Setpoint Range | 0–100 kPa |
| Injector Total Flow Setpoint Range | 0–30 mL/min |
| Detection Limit | 10 ppb (N₂ in He) |
| Detection Principle | Helium Plasma Emission Spectroscopy |
| Output Signal | 4–20 mA analog + dry contact alarms |
| Configuration Options | 0–2/0–20 ppm or 0–20/0–200 ppm dual-range modes |
| Power Options | 115 V AC or 230 V AC |
| Brand | GOW-MAC |
|---|---|
| Origin | USA |
| Model | GOW-MAC 200 |
| Instrument Type | Online Gas Chromatograph |
| Detector Options | TCD, DID, FID, PID, NPD, FPD |
| Column Compatibility | Packed & Micro-packed Columns |
| Sample Introduction | Gas Sampling Valve & Liquid Sampling Valve |
| Valve Configuration | Up to 3 Pneumatically Actuated Valves |
| Oven Temperature Range | +10 °C to 150 °C |
| Software | Clarity PC Chromatography Data System (CDS) |
| Construction | Stainless Steel Flow Path |
| Compliance | Designed for GLP/GMP environments |
| Brand | GOW-MAC |
|---|---|
| Origin | USA |
| Model | GOW-MAC 200C |
| Instrument Type | Online Gas Chromatograph |
| Application Scope | Universal Trace Gas Analysis |
| Detector Options | PDHID, TCD, FID |
| Minimum Detection Limit (CH₄) | <10 ppb |
| Construction | Corrosion-Resistant Wetted Surface Coating |
| Control Interface | High-Resolution Touchscreen LCD |
| Compliance Ready | ASTM D7623, ISO 8573-5, USP <621>, FDA 21 CFR Part 11 (Software Audit Trail Enabled) |
| Brand | GOW-MAC |
|---|---|
| Origin | USA |
| Model | GOW-MAC 582 |
| Instrument Type | Laboratory Gas Chromatograph |
| Temperature Control Range | 0–450 °C |
| Oven Ramp Rate | 0.1–50 °C/min |
| Cool-down Time | ~4 min (450 °C to 10 °C) |
| Carrier Gas Flow Range & Control | 0–45 mL/min |
| Carrier Gas Pressure Range & Control | 0–120 kPa |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–120 kPa |
| Injector Total Flow Setting Range | 0–45 mL/min |
| Brand | GOW-MAC |
|---|---|
| Origin | USA |
| Model | 75-902 |
| Operating Temperature Range | 0–250 °C |
| Maximum Working Pressure | 300 atm |
| Sample Gas Flow Rate | 30–50 mL/min |
| Power Supply | 230 VAC, 500 W |
| Dimensions (D×W×H) | 39.37 cm × 16.51 cm × 30.48 cm |
| Weight | 6.80 kg |
| Inlet Connection | 1/8″ VCR |
| Brand | GOW-MAC |
|---|---|
| Origin | USA |
| Model | GOW-MAC 836 Series |
| Instrument Type | Laboratory Gas Chromatograph |
| Column Configuration | Up to 8 Valves & 10 Columns |
| Oven Temperature Range | Ambient +4°C to 450°C |
| Max Ramp Rate | 120°C/min |
| Cooling Time | 450°C to 50°C in ≤4 min |
| Temperature Resolution | 0.1°C |
| Oven Program Steps | 20–21 ramps |
| Detector Capacity | Up to 3 Independent, Thermally Controlled Detectors |
| Detector Options | DID, TCD, FID, PID, FPD, NPD |
| Flow Control | Electronic Pressure Control (EPC) |
| Dimensions | 58 cm × 54 cm × 56 cm |
| Detection Limits | 5 ppb (CH₄, DID), 20 ppb (CH₄, FID), 2×10⁻⁹ g/mL (CₙHₘ, TCD), 1×10⁻¹² g (C₆H₆, PID), 50 ppb avg. (FPD), 10 ppb avg. (NPD) |
| Response Times | <0.5 s (DID, TCD, PID), 1 ms (FID) |
| Linear Dynamic Ranges | 10⁴–10⁷ (detector-dependent, log-log scale) |
| Brand | GOW-MAC |
|---|---|
| Origin | USA |
| Model | A16 |
| Instrument Type | Laboratory Gas Dilution Calibrator |
| Application Scope | Universal Calibration for Trace Gas Analyzers |
| Dilution Ratio Range | 1:10 to 1:10,000 (typical) |
| Flow Control Accuracy | ±0.5% of setpoint |
| Pressure Regulation Range | 0–100 psig |
| Temperature Stability | ±0.1 °C (ambient-controlled environment) |
| Output Port Configuration | Dual independent calibrated outlets |
| Compliance | ASTM D6420, ISO 6145-3, EPA Method 205 |
| Brand | GOW-MAC |
|---|---|
| Origin | USA |
| Model | Ar 722 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application | Universal (Specialized for Ultra-High-Purity Argon Impurity Profiling) |
| Temperature Control Range | 0–450 °C |
| Ramp Rate | 0.1–40 °C/min |
| Cool-down Time | ~5 min (450 °C → 10 °C) |
| Carrier Gas Flow Range & Control | 0–30 mL/min |
| Carrier Gas Pressure Range & Control | 0–100 kPa |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setpoint Range | 0–100 kPa |
| Injector Total Flow Setpoint Range | 0–30 mL/min |
| Detection Principle | Glow Discharge Photoemission Detection (GD-PED) with Argon as Carrier and Excitation Medium |
| Sensitivity (Typical LODs) | H₂ < 15 ppb |
| Accuracy | ±1% of reading (calibrated against NIST-traceable standards) |
| Brand | GOW-MAC |
|---|---|
| Origin | USA |
| Model | GM 816 TCD |
| Instrument Type | Laboratory Gas Chromatograph |
| Detector Type | Thermal Conductivity Detector (TCD) |
| Application Scope | Universal for Specialty Gas Analysis |
| Dimensions (with valve box) | 82 × 54 × 48.5 cm |
| Dimensions (without valve box) | 58 × 54 × 48.5 cm |
| Analog Outputs | Dual-channel (1 mV and 1 V) |
| Column Configuration Support | Up to 10 columns and 7 valves |
| Baseline Compensation | Single-column dual-channel |
| Corrosion-Resistant Gas Pathway | Yes |
| Diagnostic Capabilities | Real-time circuit, temperature, and leak diagnostics with automated error alerts and remediation guidance |
| Software | Customizable chromatography software package supporting remote instrument control, data acquisition, processing, and report generation |
| Remote Access | Browser-based UI for method/sequence editing, system log access, and real-time status monitoring |
| Compliance Context | Designed for GLP/GMP-aligned environments |
| Brand | GOW-MAC |
|---|---|
| Origin | USA |
| Model | GM 826 Series |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Detector Capacity | Up to Four Detectors (including one TCD) |
| Column Compatibility | Two 105 m × 0.53 mm Capillary Columns |
| Valve Automation | Supports up to 8 Automated Valves in a Single Method |
| Heating Zones | 6 Independent Zones (2 Inlets, 2 Detectors, 2 Auxiliary) |
| EPC Modules | Up to 6 Modules Controlling 16 EPC Channels |
| Sample Sequence Capacity | Up to 550 Samples |
| Communication Interfaces | Ethernet, RS-232/RS-485, Dual Analog Outputs (1 mV / 1 V / 10 V), Remote Start/Stop, Barcode Reader Option |
| Pressure & Temperature Compensation | Atmospheric Pressure and Ambient Temperature Compensation Integrated |
| Flow Path Material | Corrosion-Resistant Optional Flow Path |
| Touchscreen Interface | Integrated Color TFT Display with Intuitive GUI |
| Brand | Hailong |
|---|---|
| Origin | China |
| Manufacturer Type | Authorized Distributor |
| Configuration | Integrated Gas Chromatography (GC) and Liquid Chromatography (LC) Platform |
| EPC Capability | Optional Electronic Pressure Control for GC Carrier/Gas Lines |
| Flow Rate Range (LC) | 0.1–10.0 mL/min |
| Maximum Backpressure (LC) | Up to 30 MPa (≈306 kg/cm²) |
| Column Efficiency | ≥5,000 plates/meter |
| Temperature Program | 7–10 ramp segments with post-run oven cooling |
| Safety Features | Overtemperature cutoff, real-time self-diagnosis, intelligent rear-door airflow control |
| Display | Backlit LCD with Chinese/English bilingual interface |
| Compliance | Designed to support ISO/IEC 17025 workflows, compatible with GLP/GMP data integrity requirements when paired with validated software |
| Brand | HAMILTON |
|---|---|
| Stationary Phase | PSDVB/Trimethylammonium |
| Mode | Anion Exchange |
| Particle Size | 10 µm |
| Pore Size | 100 Å |
| Inner Diameter | 4.1 mm |
| Length | 250 mm |
| Housing Material | Stainless Steel |
| Max. Pressure | 5,000 psi |
| Exchange Capacity | 0.304 meq/column |
| pH Stability Range | 1–13 |
| Mobile Phase Compatibility | 0–100% aqueous/organic (e.g., methanol, acetonitrile) |
| Temperature Limit | 60 °C (at pH 1–7), 50 °C (at pH 8–13) |
| Regeneration Protocol | 50 mL methanol + 1% v/v 6 N HNO₃ |
| Brand | Hanbon |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Manufacturer |
| Region of Origin | Domestic (China) |
| Model | Cs-Prep 1100, Cs-Prep 1200 |
| Application Level | Industrial-Scale Preparative |
| Instrument Type | High-Pressure Preparative Liquid Chromatograph |
| Flow Rate Range | 0–300 L/h |
| Flow Accuracy | ±1.5% |
| Flow Precision (RSD) | ≤0.1% |
| Maximum Operating Pressure | 7 MPa |
| Wavelength Range | ±1 nm |
| Wavelength Repeatability | ±0.2 nm |
| Baseline Noise | ±0.5 × 10⁻⁵ AU at 254 nm |
| Data Acquisition Frequency | 20 Hz |
| Brand | Hanbon |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Manufacturer |
| Region of Origin | Domestic (China) |
| Models | 200, 300, 450, 500, 600, 800, 1000 |
| Application Level | Industrial-Scale Preparative |
| Instrument Type | High-Pressure Preparative Liquid Chromatograph |
| Flow Rate Range | 0–300 L/h |
| Flow Accuracy | ±1.5% |
| Flow Precision (RSD) | ≤0.1% |
| Maximum Operating Pressure | 10 MPa |
| Wavelength Range | ±1 nm |
| Wavelength Repeatability | ±0.2 nm |
| Baseline Noise | ±0.5 × 10⁻⁵ AU (at 254 nm) |
| Data Acquisition Frequency | 20 Hz |
| Brand | Hanbon |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | CS-Prep 1600 |
| Application Level | Industrial Preparative |
| Instrument Type | High-Pressure Preparative Liquid Chromatograph |
| Flow Rate Range | 0–300 L/h |
| Flow Accuracy | ±1.5% |
| Flow Precision (RSD) | ≤0.1% |
| Maximum Operating Pressure | 7 MPa |
| Wavelength Range | 190–800 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | ±0.2 nm |
| Baseline Noise | ±0.5 × 10⁻⁵ AU @ 254 nm |
| Data Acquisition Frequency | 20 Hz |
| Regulatory Compliance | Designed and validated per GAMP5 |
| Brand | Hanbon |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | Intepure-F 200 |
| Application Level | Laboratory-Scale |
| Instrument Type | Medium-to-Low Pressure Preparative HPLC System |
| Flow Rate Range | 1–200 mL/min |
| Flow Accuracy | ±2% |
| Flow Precision (RSD) | ±2% |
| Maximum Operating Pressure | 200 psi |
| Wavelength Range | 200–400 nm or 200–800 nm |
| Wavelength Reproducibility | ±0.5 nm |
| Baseline Noise | ±5 × 10⁻⁵ AU (254 nm, Time Constant 0.75 s) |
| Data Acquisition Rate | 20 Hz |
| Brand | Hanbon |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | Intepure-F 300 |
| Application Level | Laboratory-Scale |
| Instrument Type | Medium-to-Low Pressure Preparative HPLC System |
| Flow Rate Range | 1–300 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ±1% |
| Maximum Operating Pressure | 500 psi |
| Wavelength Range | 200–400 nm or 200–800 nm |
| Wavelength Repeatability | ±0.5 nm |
| Baseline Noise | ±5 × 10⁻⁵ AU (254 nm, Time Constant 0.75 s) |
| Data Acquisition Rate | 20 Hz |