Chromatography Instruments
Filter
Showing 511–540 of 1564 results
| Brand | Hanbon |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | CS-Prep 1600 |
| Application Level | Industrial Preparative |
| Instrument Type | High-Pressure Preparative Liquid Chromatograph |
| Flow Rate Range | 0–300 L/h |
| Flow Accuracy | ±1.5% |
| Flow Precision (RSD) | ≤0.1% |
| Maximum Operating Pressure | 7 MPa |
| Wavelength Range | 190–800 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | ±0.2 nm |
| Baseline Noise | ±0.5 × 10⁻⁵ AU @ 254 nm |
| Data Acquisition Frequency | 20 Hz |
| Regulatory Compliance | Designed and validated per GAMP5 |
| Brand | Hanbon |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | Intepure-F 200 |
| Application Level | Laboratory-Scale |
| Instrument Type | Medium-to-Low Pressure Preparative HPLC System |
| Flow Rate Range | 1–200 mL/min |
| Flow Accuracy | ±2% |
| Flow Precision (RSD) | ±2% |
| Maximum Operating Pressure | 200 psi |
| Wavelength Range | 200–400 nm or 200–800 nm |
| Wavelength Reproducibility | ±0.5 nm |
| Baseline Noise | ±5 × 10⁻⁵ AU (254 nm, Time Constant 0.75 s) |
| Data Acquisition Rate | 20 Hz |
| Brand | Hanbon |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | Intepure-F 300 |
| Application Level | Laboratory-Scale |
| Instrument Type | Medium-to-Low Pressure Preparative HPLC System |
| Flow Rate Range | 1–300 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ±1% |
| Maximum Operating Pressure | 500 psi |
| Wavelength Range | 200–400 nm or 200–800 nm |
| Wavelength Repeatability | ±0.5 nm |
| Baseline Noise | ±5 × 10⁻⁵ AU (254 nm, Time Constant 0.75 s) |
| Data Acquisition Rate | 20 Hz |
| Brand | Hanbon |
|---|---|
| Model | NP-7000 Series |
| Type | High-Pressure Preparative Liquid Chromatography Pump |
| Flow Range (NP7030C) | 0.01–300.00 mL/min, Increment: 0.01 mL/min |
| Flow Range (NP7060C) | 0.01–600.00 mL/min, Increment: 0.01 mL/min |
| Flow Range (NP7100C) | 0.1–1000.0 mL/min, Increment: 0.1 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤0.5% |
| Pressure Pulsation | ≤0.5 MPa |
| Max Pressure (NP7030C) | 15 MPa |
| Max Pressure (NP7060C/NP7100C) | 10 MPa |
| Tubing Connection | 1/8″ Standard Fitting |
| Display | 320×240 LCD |
| Control Interface | Front-panel keypad + RS232/USB computer remote control |
| Power Input | 85–264 VAC |
| Power Consumption (NP7030C/NP7060C) | 500 W |
| Power Consumption (NP7100C) | 750 W |
| Brand | Hanbon |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | NP7005-10C |
| Application Level | Industrial-Scale Preparative |
| Instrument Type | Medium-to-Low Pressure Preparative Liquid Chromatography System |
| Flow Accuracy | ±0.5% over full range (0.01–100 mL/min) |
| Flow Pulsation | <0.1% RMS (measured at 1 mL/min, 10 MPa) |
| Maximum Operating Pressure | 10 MPa |
| Display | 4.7-inch TFT LCD (320 × 240 pixels) |
| User Programs | 10 stored gradient methods |
| Communication Interface | Open ASCII-based RS-232/RS-485 protocol compliant with ASTM E1381 and IEEE 11073 standards |
| Column Cleaning Mode | Optional automated back-flush for piston and seal assembly |
| Seal Lifetime Extension | Enabled via programmable solvent rinse during idle and gradient hold phases |
| Brand | Hanbon |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Producer |
| Instrument Type | Conventional HPLC System |
| Flow Rate Range | 0.001–9.999 mL/min |
| Maximum Pressure | 40 MPa |
| Sample Injection Positions | 1 |
| Injection Volume Range | 0–50 µL |
| Temperature Control | Ambient Only |
| Wavelength Range | 190–700 nm |
| Data Acquisition Frequency | 5 Hz |
| Brand | Hanbon |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Manufacturer |
| Region of Origin | Domestic (China) |
| Model | NS4201 |
| Price Range | USD 7,000–14,000 (FOB) |
| Instrument Type | Conventional High-Performance Liquid Chromatograph |
| Application Scope | General-purpose analytical and preparative-scale development |
| Flow Rate Range | 0.001–9.999 mL/min |
| Maximum Operating Pressure | 42 MPa |
| Flow Accuracy | RSD ≤ 0.1% |
| Injection Mode | Manual injection valve (standard) |
| Injection Volume Range | 0–20 µL |
| Column Oven Temperature Control | Ambient only (no active temperature control) |
| UV-Vis Wavelength Range | 190–800 nm |
| Data Acquisition Rate | 5 Hz |
| Brand | Hanbon |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | NS4205 |
| Application Level | Laboratory-Scale |
| Instrument Type | High-Pressure Preparative LC System |
| Flow Rate Range | 0.01–49.99 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤0.1% |
| Maximum Pressure | 25 MPa |
| Wavelength Range | 190–800 nm (±2 nm accuracy) |
| Wavelength Reproducibility | ±0.2 nm |
| Baseline Noise | ≤2×10⁻⁵ AU (254 nm, 1 s time constant) |
| Data Acquisition Rate | 5 Hz |
| Brand | Hanbon |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | NS4210 |
| Price Range | USD 14,000 – 28,000 |
| Application Level | Laboratory-Scale |
| Instrument Type | High-Pressure Preparative LC System |
| Flow Rate Range | 0.01–100 mL/min |
| Flow Accuracy | ±0.5% |
| Flow Precision (RSD) | ≤0.1% |
| Maximum Pressure Rating | 20 MPa |
| Wavelength Range | 190–700 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | ±0.2 nm |
| Baseline Noise | ±0.5 × 10⁻⁵ AU |
| Data Acquisition Frequency | 5 Hz |
| Brand | Hanbon |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | NS43100 |
| Application Level | Industrial-Scale Preparative |
| Instrument Type | High-Pressure Preparative Liquid Chromatography System |
| Flow Rate Range | 0.01–599.99 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤1% |
| Maximum Operating Pressure | 15 MPa |
| Wavelength Range | ±2 nm |
| Wavelength Reproducibility | 0.2 nm |
| Baseline Noise | 2 × 10⁻⁵ AU (254 nm, TC = 1 s) |
| Data Acquisition Frequency | 5 Hz |
| Brand | Hanbon |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | NS4330 |
| Application Level | Laboratory-Scale |
| Instrument Type | High-Pressure Preparative Liquid Chromatography System |
| Flow Rate Range | 0.1–3000.0 mL/min |
| Flow Accuracy | ±1.5% |
| Flow Precision (RSD) | ≤1% |
| Maximum Pressure | 15 MPa |
| Wavelength Range | 0.5 nm |
| Wavelength Reproducibility | 0.1 nm |
| Baseline Noise | ±0.5 × 10⁻⁵ AU |
| Data Acquisition Frequency | 5 Hz |
| Brand | Hanbon |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Producer |
| Product Category | Domestic |
| Model | NS43300 |
| Application Level | Industrial Preparative |
| Instrument Type | High-Pressure Preparative HPLC |
| Flow Rate Range | 0.1–2999.9 mL/min |
| Flow Accuracy | RSD ≤ 1% |
| Flow Precision (Repeatability) | ≤ 1% |
| Maximum Operating Pressure | 10 MPa |
| Wavelength Range | ±2 nm |
| Wavelength Repeatability | 0.2 nm |
| Baseline Noise | 2 × 10⁻⁵ AU |
| Data Acquisition Frequency | 5 Hz |
| Brand | Hanbon |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | NS4360 |
| Application Level | Industrial-Scale Preparative |
| Instrument Type | High-Pressure Preparative Liquid Chromatography System |
| Flow Rate Range | 0.01–599.99 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤1% |
| Maximum Pressure | 15 MPa |
| Wavelength Range | ±2 nm |
| Wavelength Repeatability | 0.2 nm |
| Baseline Noise | 2 × 10⁻⁵ AU (254 nm, TC = 1 s) |
| Data Acquisition Frequency | 5 Hz |
| Brand | Hanbon |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Models | NS8002 / NS8005 / NS80010 |
| Instrument Type | Semi-Preparative |
| Detector Type | UV (optional ELSD) |
| Maximum System Pressure | 25 MPa (42 MPa burst rating) |
| CO₂ Flow Rate Range | 0–100 mL/min |
| Modifier Flow Rate Range | 0–50 mL/min |
| Column ID Range | 10–30 mm |
| Price Range | USD 70,000–112,000 (FOB China) |
| Brand | Hanbon |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | NS8030A |
| Instrument Type | Preparative |
| Detector Type | UV |
| Maximum System Pressure | 20 MPa |
| Flow Rate Range | 0–300 mL/min |
| CO₂ Recovery System | Integrated |
| Collection Technology | Patented Cyclonic Collector |
| Brand | Hanbon |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Preparative |
| Detector Type | UV |
| Maximum Operating Pressure | 20 MPa |
| Flow Rate Range | 0–3000 mL/min |
| Model Variants | NS8030A, NS8030B |
| Brand | Hanbon |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | NS8300A/B |
| Instrument Type | Preparative |
| Detector Type | UV |
| Maximum Operating Pressure | 20 MPa |
| Flow Rate Range | 0–3000 mL/min |
| Brand | Hanbon |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | NS9001S |
| Application Level | Laboratory-Scale |
| Instrument Type | Medium-to-Low Pressure Preparative Liquid Chromatography |
| Flow Rate Range | 0–99.99 mL/min |
| Flow Accuracy | ±0.5% |
| Flow Precision (RSD) | ≤0.1% |
| Maximum Operating Pressure | 1 MPa |
| Wavelength Range | ±1 nm |
| Wavelength Repeatability | ±0.2 nm |
| Baseline Noise | 0.5 × 10⁻⁵ AU |
| Data Acquisition Frequency | 50 Hz |
| Brand | Hanbon |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | NS9002S |
| Application Level | Laboratory-Scale |
| Instrument Type | High-Pressure Preparative Liquid Chromatography System |
| Flow Rate Range | 0–99.99 mL/min |
| Flow Accuracy | ±0.5% |
| Flow Precision (RSD) | ≤0.1% |
| Maximum Operating Pressure | 15 MPa |
| Wavelength Range | ±1 nm |
| Wavelength Repeatability | ±0.2 nm |
| Baseline Noise | 0.5 × 10⁻⁵ AU |
| Data Acquisition Frequency | 50 Hz |
| Brand | Hanbon |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | SFC-Lab20 |
| Instrument Type | Semi-Preparative |
| Detector Type | UV-Vis (190–700 nm) |
| Maximum System Pressure | 25 MPa |
| CO₂ Pump Flow Rate | 4–20 mL/min |
| Co-solvent Pump Flow Rate | ≤10 mL/min |
| Column Oven Temperature Range | Ambient to 70 °C |
| Back Pressure Regulator Range | 0–25 MPa |
| Compatible Column Dimensions | 4.6 × 250 mm (analytical development), 10 × 250 mm (semi-prep separation) |
| Data System | GreenChrom Chromatography Workstation |
| Brand | Kechuang |
|---|---|
| Model | GC2002 |
| Detector Type | Pulsed Discharge Helium Ionization Detector (PDHID) |
| Configuration | Laboratory-Scale Gas Chromatograph |
| Origin | Shanghai, China |
| Intended Use | Universal gas-phase trace noble gas analysis |
| Compliance | Designed for ISO 17025-compliant laboratories |
| Detection Capability | Sub-ppm quantification of Kr and Xe in multi-component gas matrices |
| Carrier Gas | High-purity helium (≥99.999%) |
| Column Compatibility | Capillary columns with porous layer open tubular (PLOT) or molecular sieve stationary phases |
| Operating Temperature Range | Oven: 30–250 °C |
| Detector | 150–350 °C |
| Data Acquisition | Digital signal processing with 24-bit ADC resolution |
| Software Interface | PC-based chromatography data system (CDS) with audit trail and electronic signature support per FDA 21 CFR Part 11 |
| Brand | KeChuang |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic |
| Model | GC2002N/PDHID |
| Price | USD 35,000 (FOB Shanghai) |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Domain | Dedicated to High-Purity Gas Analysis |
| Oven Temperature Range | 0–400 °C |
| Maximum Ramp Rate | 40 °C/min |
| Maximum Cooling Rate | 60 °C/min (achieves 400 °C → 50 °C in ≤4 min) |
| Carrier Gas Flow Range & Control | 0–500 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.4 MPa |
| Injector Maximum Operating Temperature | 300 °C |
| Injector Pressure Setting Range | 0–0.4 MPa |
| Injector Total Flow Setting Range | 0–500 mL/min |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | HQX-101 |
| Price Range | USD 7,000–14,000 (FOB Beijing) |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Application Scope | General-Purpose Analytical GC |
| Oven Temperature Range | Ambient to 450 °C |
| Oven Ramp Rate | 0.1–80 °C/min |
| Oven Cool-Down Rate | 0.1–40 °C/min |
| Carrier Gas Flow Range & Control | 0–200 mL/min |
| Carrier Gas Pressure Range & Control | Up to 5 MPa |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setting Range | Atmospheric (constant-pressure mode) |
| Injector Total Flow Setting Range | Up to 200 mL/min |
| Brand | Henven |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (PRC) |
| Model | HQX-2010 |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Application Scope | General-Purpose Analytical GC |
| Temperature Control Accuracy | Better than ±0.1 °C |
| Oven Ramp Rate | 0.1–40 °C/min |
| Maximum Injector Temperature | 450 °C |
| Injector Temperature Setpoint Range | 5 °C above ambient to 450 °C |
| Injector Total Flow Setting Range | 5 °C above ambient to 450 °C |
| Number of Independent Temperature Zones | 6 |
| Programmed Temperature Ramps | 8-step |
| Column Compatibility | Capillary (including 0.53 mm ID) and Packed Columns |
| Injector Configurations | Dual or triple inlet options (gas/liquid), optional six-port valve and methanizer support |
| Detector Support | Multiple detector modules (FID, TCD, ECD, FPD — detector-specific specs not provided) |
| Brand | HUIFEN Instrument |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | HF-901A |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | Ambient + 5 °C to 450 °C |
| Ramp Rate | 0.1–80 °C/min |
| Cool-Down Rate | 350 °C → 50 °C in <5 min |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Temperature Control Zones | 8 independent zones with over-temperature protection |
| Display | 7-inch industrial color LCD touchscreen |
| Language Support | English & Chinese |
| Programmed Temperature Ramping | Up to 16 steps (expandable) |
| Maximum Run Time | 999.99 min |
| Injection Modes | Split/splitless capillary, packed column, valve injection, auto liquid/gas sampling |
| Detector Capacity | Up to 4 detectors simultaneously |
| Supported Detectors | FID, TCD, ECD, FPD, NPD, PDHID, PED |
| FID Detection Limit | ≤3.0×10⁻¹² g/s (n-hexadecane in iso-octane) |
| FID Linear Dynamic Range | ≥10⁷ |
| TCD Sensitivity | ≥10,000 mV·mL/mg (benzene/toluene) |
| TCD Linear Dynamic Range | ≥10⁵ |
| FPD Detection Limits | S ≤2×10⁻¹¹ g/s, P ≤1×10⁻¹² g/s (methyl parathion) |
| ECD Detection Limit | ≤1.0×10⁻¹⁴ g/mL (γ-HCH) |
| NPD Detection Limits | N ≤1.0×10⁻¹² g/s (azobenzene), P ≤1.0×10⁻¹² g/s (malathion) |
| Brand | Hitachi |
|---|---|
| Origin | Japan |
| Manufacturer | Hitachi High-Tech Corporation |
| Product Type | Imported Instrument |
| Model | ChromAssist Data Station |
| Pricing | Upon Request |
| Brand | Hitachi |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | ChromAssist Database Edition |
| Instrument Type | Conventional High-Performance Liquid Chromatograph (HPLC) System Software |
| Deployment Options | Standalone & Networked |
| Regulatory Compliance | FDA 21 CFR Part 11, ALCOA+ Principles, ISO/IEC 17025 Annex A.3, ICH GCP, USP <1058> Analytical Instrument Qualification |
| Brand | Hitachi |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Conventional HPLC System |
| Flow Rate Range | 0.001–9.999 mL/min at ≤40 MPa |
| Maximum Operating Pressure | 60 MPa |
| Flow Accuracy | ≤0.05% RSD |
| Sample Injection Positions | 200 |
| Injection Volume Range | 0.1–100 µL |
| Column Oven Temperature Range | (Ambient −15 °C) to 85 °C |
| UV-Vis Wavelength Range | 190–900 nm |
| Data Acquisition Rate | 100 Hz |
| Brand | Hitachi |
|---|---|
| Origin | Japan (manufactured by Hitachi High-Tech Corporation) |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Conventional HPLC System |
| Flow Rate Range | 0.001–9.999 mL/min at ≤40 MPa |
| Maximum Pressure | 60 MPa |
| Flow Accuracy | ≤0.05% RSD |
| Injection Volume Range | 0.1–100 µL |
| Autosampler Capacity | 200 positions |
| Column Oven Temperature Range | (Ambient −15 °C) to 85 °C |
| UV-Vis Wavelength Range | 190–900 nm |
| Data Acquisition Rate | 100 Hz |
| Brand | Hitachi |
|---|---|
| Origin | Japan |
| Manufacturer | Hitachi High-Tech Corporation |
| Product Type | Imported Instrument |
| Model | ChromasterUltra Rs |
| Instrument Category | Ultra-High-Performance Liquid Chromatograph (UHPLC) |
| Application Scope | General-Purpose Analytical Platform |
| Flow Rate Range | 0.001–2.5 mL/min |
| Maximum System Pressure | 140 MPa |
| Flow Precision | ≤0.06% RSD |
| Autosampler Capacity | 120 positions |
| Injection Volume Range | 0.1–20 µL |
| Column Oven Temperature Range | (Ambient −15 °C) to 90 °C |
| UV-Vis Wavelength Range | 100–900 nm |
| Data Acquisition Rate | 100 Hz |