Chromatography Instruments
Filter
Showing 151–180 of 662 results
| Brand | Aotsaisiens |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic Chromatography Column |
| Model Range | 150 × 4.6 mm, 200 × 4.6 mm, 250 × 4.6 mm |
| Particle Size | 5 µm, 7 µm (C18 only), 10 µm |
| Pore Size | 100 Å |
| Surface Area | 340 m²/g |
| Pore Volume | 0.9 mL/g |
| Carbon Load | 19% (3.2 µmol/m²) |
| pH Stability | 1.5–9.5 |
| Max. Operating Pressure | 700 bar (10,000 psi) |
| End-Capping | Fully end-capped (C18) |
| Metal Impurities (AAS) | Na < 10 ppm, Al < 10 ppm, Fe < 10 ppm |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | APL-GC-901A |
| Temperature Control Range | Ambient +4°C to 450°C |
| Maximum Ramp Rate | 80°C/min |
| Cooling Time | <7 min (250°C to 50°C) |
| Carrier Gas Flow Range | 0–500 mL/min |
| Carrier Gas Pressure Range | 0–0.6 MPa |
| Injector Maximum Temperature | 350°C |
| Injector Pressure Setting Range | 0–0.4 MPa |
| Total Injector Flow Setting Range | 0–1000 mL/min |
| Temperature Zones | 8 independently controlled zones |
| Programmed Temperature Ramping | Up to 16 steps |
| Ramp Rate Adjustable | 0.1–60°C/min |
| Temperature Stability | ±0.1°C |
| Display | 7-inch capacitive touchscreen LCD |
| Detector Compatibility | FID, TCD, ECD, FPD, NPD (up to 3 simultaneously installed) |
| Injection Options | Packed column, capillary column, dual-capillary, valve-based gas injection, headspace, thermal desorption, autosampler-ready |
| Column Oven Dimensions | 260 × 270 × 235 mm |
| Communication Interface | Ethernet (IEEE 802.3) |
| External Events | 8 inputs, 2 auxiliary outputs |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | GC-7890 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | 5 °C above ambient to 420 °C (1 °C increment programmable) |
| Maximum Oven Operating Temperature | 400 °C |
| Heating Rate | Up to 40 °C/min |
| Cooling Rate | 280 °C → 50 °C in ≤8 min |
| Carrier Gas Flow Control Range | 0–50 mL/min |
| Carrier Gas Pressure Control Range | 0–0.35 MPa |
| Injector Maximum Temperature | 400 °C |
| Injector Pressure Setting Range | 0–0.35 MPa |
| Total Injector Flow Setting Range | 0–500 mL/min |
| Temperature Stability (≤180 °C) | ±0.01 °C |
| Temperature Stability (full range) | ±0.1 °C |
| Programmable Temperature Ramping | 7-stage |
| Independent Temperature Control | Dual vaporizers (capillary & packed column) |
| Detector Configuration | FID (Hydrogen Flame Ionization Detector) |
| FID Detection Limit | ≤5×10⁻¹² g/s (n-hexadecane) |
| FID Noise | ≤5×10⁻¹⁴ A |
| FID Drift | ≤1×10⁻¹³ V/h |
| FID Linear Dynamic Range | ≥10⁷ |
| Column Compatibility | Up to three packed columns or two capillary columns simultaneously |
| Detector Capacity | Up to three detectors + methanizer |
| Optional Features | Integrated AD conversion circuit, cryogenic oven operation (dry ice/liquid nitrogen), dual rear doors with intelligent control, ceramic or quartz jet nozzles |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | APL-GC-901 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | Ambient to 450 °C |
| Oven Ramp Rate | 0.1–80 °C/min |
| Oven Cool-Down Rate | 0.1–80 °C/min |
| Carrier Gas Flow Range & Control | 0–100 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.6 MPa |
| Injector Maximum Operating Temperature | Ambient to 450 °C |
| Injector Pressure Setpoint Range | 0–0.6 MPa |
| Injector Total Flow Setpoint Range | 0–100 mL/min |
| Temperature Zones | 8 independently controlled zones |
| Programmable Temperature Steps | 16 stages |
| External Event Inputs | 6 channels |
| Auxiliary Outputs | 2 channels |
| Detector Capacity | Up to 3 detectors (FID, TCD, ECD, FPD, NPD selectable) |
| Injection Modes | Packed column, capillary column, valve injection, headspace (with optional autosampler), thermal desorption |
| EPC/EFC Modes | Constant-flow and constant-pressure |
| Supported Gases | N₂, H₂, Air, He, Ar |
| EPC Pressure Resolution | 0.01 psi |
| EPC Flow Resolution | 0.01 mL/min |
| Communication Interface | 10/100 M adaptive Ethernet with embedded TCP/IP stack |
| Software | iBrainChrom workstation supporting up to 253 concurrent GC systems, 21 CFR Part 11 compliance (audit trail, role-based user permissions, electronic signatures), Modbus RTU protocol for DCS integration |
| Brand | APL |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Temperature Control Range | 8°C above ambient to 425°C |
| Oven Ramp Rate | Up to 75°C/min |
| Carrier Gas Pressure Control Range | 0–689.47 kPa (0–100 psi) |
| Injector Maximum Operating Temperature | 400°C |
| Injector Pressure Setting Range | 0–689.47 kPa |
| Injector Total Flow Setting Range | 0–100 psi |
| Brand | Arun Technology Ltd. |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | PGC Industrial Online Gas Chromatograph |
| Pricing | Available Upon Request |
| Brand | ASD |
|---|---|
| Origin | Canada |
| Model | KA5800 |
| Instrument Type | Online Analyzer |
| Application Scope | General-Purpose |
| Operating System | Embedded Linux with Touchscreen Interface |
| Detection Principle | Dual-Polarity Pulsed Electrochemical Conductivity Detection |
| Data Acquisition | Real-Time Asynchronous Parallel Chromatography |
| Sample Introduction | Automated Multi-Channel Switching with Integrated Pre-Treatment Module |
| Calibration Method | Single-Point Standard-Based Auto-Calibration |
| Detection Enhancement | eLOD Noise-Filtering Algorithm (3–5× Sensitivity Gain) |
| Gas Capture Technology | Multi-Threaded Aeration Trapping (KA5800-EIC Variant, Patent Pending) |
| Analysis Cycle | <30 min per Full Sequence |
| Sample Volume Requirement | ≤1.5 L for ppb-Level Analysis |
| Compliance Framework | Designed for GLP/GMP Environments |
| Temperature Control | Digital Precision Dual-Zone Column & Detector Thermostat |
| Brand | ASD |
|---|---|
| Origin | Canada |
| Model | Ka6000 Plus |
| Instrument Type | Online Gas Chromatograph |
| Temperature Control Range | Ambient +4 °C to 450 °C |
| Maximum Ramp Rate | 75 °C/min |
| Cooling Rate | ~6 min (from 400 °C to 50 °C) |
| Carrier Gas Flow Range | 30–100 mL/min |
| Carrier Gas Pressure Range | 90–100 psig |
| Injector Max Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 3–25 psig |
| Injector Total Flow Setting Range | 5–200 mL/min |
| Column Oven Zones | Up to 4 independently controlled zones |
| Valves | Up to 5 programmable PLSV valves |
| Detectors | Up to 2 gas-phase detectors (e.g., EPD) |
| Detection Limit (LOD) | <1 ppb (stable, compound-dependent) |
| Brand | ASD |
|---|---|
| Origin | Canada |
| Model | KA8000 |
| Instrument Type | Online Gas Chromatograph |
| Temperature Control Range | Ambient + 4 °C to 450 °C |
| Ramp Rate | 30–60 °C/min |
| Cool-down Rate | 30–60 °C/min |
| Carrier Gas Flow Range & Control | 20–50 mL/min |
| Carrier Gas Pressure Range & Control | 90–100 psig |
| Injector Maximum Operating Temperature | 200 °C |
| Injector Pressure Setting Range | 5–15 psig |
| Injector Total Flow Setting Range | 20–30 mL/min |
| Brand | ASD |
|---|---|
| Origin | Canada |
| Model | KA8000plus-S |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Hydrogen Fuel Purity Analysis |
| Temperature Control Range | Ambient +4 °C to 450 °C |
| Maximum Ramp Rate | 75 °C/min |
| Cooling Rate | ~6 min (400 °C → 50 °C) |
| Carrier Gas Flow Range & Control | 30–100 mL/min |
| Carrier Gas Pressure Range & Control | 90–100 psig |
| Injector Max Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 3–25 psig |
| Injector Total Flow Setting Range | 5–200 mL/min |
| Detector | SePDD (Sulfur-Enhanced Plasma Discharge Detector) |
| Valve Configuration | PLSV Inert 6-Port Valve with 2 mL Inert Quantitative Loop |
| Carrier Gas Requirement | Ultra-High-Purity Helium (≥5.0, purified to <1 ppb total impurities via ASDPure gas purifier) |
| Detection Limit | <0.5 ppb (as H₂S equivalent, direct injection) |
| Brand | ASD |
|---|---|
| Origin | Canada |
| Model | PAD |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Coal Industry-Specific |
| Temperature Control Range | −4 °C to 450 °C |
| Oven Ramp Rate | 30–60 °C/min |
| Oven Cool-Down Rate | 30–60 °C/min |
| Carrier Gas Flow Range & Control | 20–50 mL/min |
| Carrier Gas Pressure Range & Control | 90–100 psig |
| Injector Maximum Operating Temperature | 200 °C |
| Injector Pressure Setting Range | 5–15 psig |
| Injector Total Flow Setting Range | 20–30 mL/min |
| Brand | ASDevices |
|---|---|
| Origin | Canada |
| Model | CYPPB-01 |
| Instrument Type | Online Gas Chromatograph |
| Application Scope | General-Purpose |
| Dilution Ratio Range | 1:2 to 1:3500 (customizable up to 1:10,000) |
| Relative Accuracy | < 0.5% |
| Certified Traceability | NIST-traceable calibration certificate |
| Core Technology | Critical-Orifice-Based Sonic Nozzle Dynamic Dilution |
| Construction | All-welded stainless steel flow path |
| Temperature-Controlled Path | Up to 200 °C |
| Pressure Regulation | Dual EPC with temperature compensation |
| Flow Configuration Options | Direct-coupled or high-integrity bypass |
| Purification Module | iGCSASDPure integrated gas purifier |
| Compliance | Designed for ISO/IEC 17025-compliant calibration labs and GLP/GMP environments |
| Brand | ASD |
|---|---|
| Origin | Canada |
| Model | IC-KA5800 |
| Instrument Type | Online Analyzer |
| Application Scope | Universal Gas Impurity Analysis |
| Compliance Framework | ASTM D7622, ISO 14687-2, GB/T 37244–2018, USP <645> (for total ionizable impurities) |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | Aseeker-100Plus |
| Instrument Category | Fast Liquid Chromatography System |
| Flow Rate Range | 0.001–10 mL/min |
| Maximum Pressure Rating | 50 MPa |
| Sample Injection Volume | 1–60 µL |
| Injection Vial Capacity | 2 mL |
| Temperature Control Range | 10–50 °C |
| Wavelength Detection Range | 100–700 nm |
| Data Acquisition Frequency | 100 Hz |
| Extraction Temperature Range | Ambient to 200 °C (±1 °C) |
| Pressure Range | 0–20 MPa (±0.3 MPa) |
| Pump Flow Range | 0.1–50 mL/min |
| Standard Extraction Cell Volume | 40 mL (optional: 10 mL / 20 mL) |
| Standard Collection Vial Volume | 250 mL (optional: 60 mL) |
| Solvent Mixing Capability | Up to 4 solvents |
| Typical Extraction Duration | 20–30 min |
| Solvent Consumption | ~10 mL per 10 g sample |
| Required Gas Supply | Nitrogen, 0.4–1 MPa |
| Max Power Consumption | 600 W |
| Electrical Input | 100–240 VAC ±10%, 50–60 Hz |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | Aseeker-350Plus |
| Flow Rate Range | 0.001–10 mL/min |
| Maximum Pressure | 50 MPa |
| Sample Injection Volume | 1–60 µL |
| Temperature Control Range | 10–50 °C |
| Wavelength Range | 100–700 nm |
| Data Acquisition Frequency | 100 Hz |
| Extraction Cell Volume (Standard) | 120 mL |
| Pressure Accuracy | ±0.3 MPa |
| Temperature Accuracy | ±0.5 °C |
| Solvent Channels | 4 |
| Simultaneous Extraction Positions | 5 |
| Extraction Time per Batch (5 samples) | ≤20 min |
| Power Consumption | ≤1.7 kW |
| Gas Supply Requirement | N₂, 0.4–1 MPa |
| Brand | Asicotech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | M3 |
| Price Range | USD 14,000 – 280,000 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | −30 °C to 450 °C |
| Oven Ramp Rate | 0–150 °C/min |
| Cooling Rate | 0–150 °C/min |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–150 psi |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setpoint Range | 0–150 psi |
| Injector Total Flow Setpoint Range | 0–1000 mL/min |
| Brand | Asicotech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Regional Classification | Domestic (China) |
| Model | Asicotech M6 GC System |
| Price Range | USD 21,000 – 280,000 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | −30 °C to 460 °C |
| Oven Ramp Rate | 0–200 °C/min |
| Oven Cool-Down Rate | 0–150 °C/min |
| Carrier Gas Flow Range & Control | 0–100 mL/min |
| Carrier Gas Pressure Range & Control | 0–150 psi |
| Injector Maximum Operating Temperature | 460 °C |
| Injector Pressure Setting Range | 0–150 psi |
| Injector Total Flow Setting Range | 0–2000 mL/min |
| Brand | Asicotech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | M8 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Temperature Control Range | Ambient +4 °C to 450 °C |
| with Liquid Nitrogen Cooling | −80 °C to 450 °C |
| with CO₂ Cooling | −40 °C to 450 °C |
| Oven Ramp Rate | Up to 120 °C/min |
| Oven Cool-Down | 450 °C → 50 °C in 3.5 min |
| Carrier Gas Flow Range & Control | N₂: 0–200 mL/min (optional 500 mL/min) |
| He/H₂ | 0–1250 mL/min |
| Carrier Gas Pressure Range & Control | 0–150 PSI |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–150 PSI |
| Injector Total Flow Setting Range | N₂: 0–200 mL/min (optional 500 mL/min) |
| He/H₂ | 0–1250 mL/min |
| Brand | Asicotech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Model | P6000+ |
| Detection Limit | ≤0.03 ppm (for target VOCs) |
| Repeatability | <1% RSD |
| Operating System | Embedded Linux |
| Power & Carrier Gas Consumption | <10% of conventional benchtop GC systems |
| Modular Interface | Standardized electrical, pneumatic, and data ports for plug-and-play detector and injector modules |
| Remote Control Capability | Full web-based instrument control and real-time data streaming via Ethernet/Wi-Fi |
| Brand | Autoscience |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | UF-9100 |
| Pricing | Upon Request |
| Brand | Axel Semrau |
|---|---|
| Origin | Germany |
| Model | CHRONECT LC-GC |
| Temperature Control Range | 4–450 °C |
| Oven Ramp Rate | up to 120 °C/min |
| Oven Cool-down Rate | up to 100 °C/min |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa (7 pressure segments) |
| Injector Max Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Brand | BANFF |
|---|---|
| Model | Da Vinci I |
| Type | Portable Gas Chromatograph with FID |
| Origin | Zhejiang, China |
| Manufacturer | BANFF Biotechnology |
| Application Domain | Environmental Monitoring |
| Compliance Standards | HJ 38-2017, HJ 1012-2018, HJ 604-2017, GB/T 31705-2015, JJG 700-2016, JJF (Su) 225-2019 |
| Certification Framework | RB/T 214, HJ 630 |
| Connectivity | Wi-Fi & 4G remote control |
| Detection Principle | Gas Chromatography–Flame Ionization Detection (GC-FID) |
| Operational Modes | Lab-based stationary analysis & field-deployable on-site analysis (including explosion-proof environments) |
| Data Output | Auto-generated audit-trail-compliant reports |
| Brand | BANFF |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | Da Vinci MINI |
| Instrument Type | Portable Gas Chromatograph |
| Application Field | Environmental Monitoring |
| Detection Principle | Gas Chromatography with Flame Ionization Detection (GC-FID) |
| Target Analytes | Total Hydrocarbons (THC), Methane (CH₄), Non-Methane Hydrocarbons (NMHC), BTEX, Halogenated VOCs |
| Compliance Standards | HJ 1012–2018, HJ 38–2017, DB11/1367–2016, DB12/524–2020, DB51/2377–2017, JJG 700–2016, JJF (Su) 225–2019 |
| Brand | Banff |
|---|---|
| Model | P100 |
| Type | Portable Gas Chromatograph |
| Detection Principle | Microfluidic GC with PID Detection |
| Detection Limit | Sub-ppb (VOCs) |
| Sample Introduction | Ambient Air / Headspace / Canister via Integrated Microtrap |
| Compliance | Aligned with GB/T 18883–2022 (Indoor Air Quality Standard) |
| Software | Embedded Real-Time Analysis Engine with Auto-Report Generation |
| Calibration | Onboard Method Calibration & Multi-Point Standard Gas Support |
| Maintenance | Automated Post-Run Trap & Flow Path Purge |
| Power | Rechargeable Li-ion Battery (≥4 h continuous operation) |
| Dimensions | 295 × 220 × 145 mm |
| Weight | 3.2 kg |
| Operating Temperature | 5–40 °C |
| Humidity Range | 10–90% RH (non-condensing) |
| Brand | BCT |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (PRC) |
| Model | P6100 |
| Pricing | Upon Request |
| Brand | Beifen Ruili |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Regional Category | Domestic (PRC) |
| Model | MAS-100 |
| Pricing | Upon Request |
| Brand | Beifen Ruili |
|---|---|
| Origin | Beijing, China |
| Model | SP-2110 |
| Instrument Type | Dedicated Gas Chromatograph for Dissolved Gas Analysis (DGA) in Transformer Oil |
| Compliance | Designed to meet GB/T 17623–2017, DL/T 703–2015, and IEC 60567 requirements |
| Interface | USB 2.0 |
| Data Acquisition | Integrated with Transformer Oil DGA-Specific Chromatography Workstation |
| Injection System | Manual syringe injection with micro-switch trigger activation |
| Gas Control | Equipped with digital pressure and mass flow sensors for carrier gas (N₂, H₂, or Ar) and detector gases |
| Detector Configuration | Dual-TCD (Thermal Conductivity Detector) or TCD+FID (optional) |
| Column | Pre-packed stainless-steel capillary or packed column optimized for C₁–C₅ hydrocarbons and CO/CO₂ separation |
| Brand | Beifen Ruili |
|---|---|
| Origin | Beijing, China |
| Model | SP-2120 |
| Temperature Control Range | 20–400 °C above ambient |
| Ramp Rate | 0.5–35 °C/min |
| Cool-down Time | <5 min (250 °C → 50 °C) |
| Carrier Gas Pressure Range & Control | 0–0.8 MPa |
| Injector Max Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–0.8 MPa |
| Detection Limits | H₂ ≤5 ppm, CO ≤0.5 ppm, O₂/N₂ ≤0.05 vol%, CH₄/CO₂/C₂H₄/C₂H₆/C₂H₂ ≤0.1 ppm |
| Total Analysis Time | ≤7 min (single injection, 9-component full profile) |
| Simultaneous Active Detectors | 3 (TCD + dual FID) |
| Flow Sensors | 4-channel digital gas flow monitoring |
| Valve Configuration | High-reliability imported 10-port rotary valve |
| Explosion Risk Assessment | Real-time calculation per GB/T 20964–2007 and AQ 1018–2006 |
| Compliance | Designed for GLP-compliant coal mine safety labs |
| Brand | Beifen Ruili |
|---|---|
| Origin | Beijing, China |
| Model | SP-3420A |
| Temperature Control Range | Ambient +12 °C to 400 °C |
| Maximum Oven Ramp Rate | >35 °C/min (100 °C to 200 °C in <3 min) |
| Injector Maximum Temperature | 400 °C |
| Injector Pressure Setting Range | 0–0.6 MPa |
| Compatible Detectors | TCD, FID, ECD, FPD, TSD |
| Injection Systems | Packed Column Injector, Split/Splitless Capillary Injector |
| Method Storage Capacity | 4 pre-programmed methods |
| Diagnostic Capability | Real-time self-diagnostic with fault localization |
| Safety Protections | TCD carrier-gas failure protection, overtemperature shutdown, FPD light-leak detection |
| Brand | Beifen Ruili |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | SP-3500 |
| Price Range | USD 14,000–21,000 (FOB) |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | 5°C above ambient to 450°C |
| Maximum Ramp Rate | 50°C/min |
| Carrier Gas Flow Control | 0–1000 mL/min (H₂) |
| Carrier Gas Pressure Control | 0–100 psi |
| Injector Maximum Operating Temperature | 400°C |
| Injector Pressure Setting Range | 0–100 psi |
| Injector Total Flow Setting Range | 0–1000 mL/min (H₂) |