Chromatography Instruments
Filter
Showing 181–210 of 662 results
| Brand | Beifen Ruili |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (PRC) |
| Model | SP-3510 |
| Price Range | USD 14,000–21,000 (FOB Beijing) |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | 5 °C above ambient to 450 °C |
| Maximum Ramp Rate | 50 °C/min |
| Cooling Capability | Forced-air cooling (no cryogenic option) |
| Carrier Gas Flow Control Range | 0–1000 mL/min (H₂) |
| Carrier Gas Pressure Control Range | 0–100 psi |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–150 psi |
| Injector Total Flow Setting Range | 0–1000 mL/min (H₂) |
| Heating Zones | 9 independent temperature-controlled zones |
| Simultaneous Inlets/Detectors | Up to 3 inlets and 3 detectors operational concurrently |
| Detector Options | FID, TCD, ECD, FPD, TSD, AFD |
| Brand | Beifen Ruili |
|---|---|
| Origin | Beijing, China |
| Model | SP-5220 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Regulatory Compliance | CE-marked per EN 61010-1, IEC 61326-1 (EMC), ISO/IEC 17025-compatible operation |
| Control System | Linux-based embedded platform with Ethernet and USB 2.0 interfaces |
| Pressure Control Accuracy | ±0.001 psi (EPC) |
| Temperature Program Reproducibility | ±0.5% (RSD) |
| MTBF | >12,000 hours |
| Safety Certification | UL 61010-1 / GB 4793.1 compliant |
| Electromagnetic Compatibility | Tested to IEC 61326-1 Class A |
| Brand | Beifen Ruili |
|---|---|
| Origin | Beijing, China |
| Model | SP3400 |
| Temperature Control Range | Ambient +12 °C to 420 °C |
| Maximum Oven Ramp Rate | >33 °C/min (100 °C to 200 °C in <3 min) |
| Injector Max Operating Temperature | 420 °C |
| Injector Pressure Setting Range | 0–0.6 MPa |
| Detector Options | TCD, FID, ECD, FPD, TSD |
| Injector Types | Packed Column Injector, Split/Splitless Capillary Injector |
| Method Storage Capacity | 4 methods |
| Compliance | Designed to meet ISO/IEC 17025 operational prerequisites for routine GC analysis |
| Brand | Beifen Ruili |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (PRC) |
| Model | SY-9100 |
| Price Range | USD 14,000–28,000 |
| Instrument Type | Conventional HPLC System |
| Application Scope | General-purpose analytical use |
| Flow Rate Range | 0.001–9.999 mL/min (0.001 mL/min increment) |
| Maximum Operating Pressure | 42 MPa |
| Flow Precision | <0.1% RSD |
| Sample Tray Capacity | 96 positions (1.5 mL vials) |
| Injection Volume Range | 1–100 µL |
| Column Oven Temperature Range | Ambient +5 °C to 100 °C |
| UV-Vis Wavelength Range | 190–800 nm |
| Data Acquisition Frequency | 50 Hz |
| Brand | Beifen Ruili |
|---|---|
| Origin | Beijing, China |
| Model | SY9230 |
| Instrument Type | Laboratory Benchtop Ion Chromatograph |
| Application Scope | General-Purpose Anion and Cation Analysis |
| Pump Pressure Range | 0–35 MPa |
| Flow Rate Range | 0–9.999 mL/min |
| Eluent Flow Rate Accuracy | 0.1–5.0 mL/min |
| Max Operating Pressure | 35 MPa |
| Column Oven Temperature Range | Ambient +5 °C to 60 °C |
| Temperature Stability | ±0.2 °C |
| Eluent Concentration Range | 0.1–100 mM |
| Fluidic Path Material | Full-PEEK (Polyetheretherketone) |
| Eluent Generation | On-Demand Electrolytic Eluent Generator (EG) with Water-Only Input |
| Degassing | Integrated Low-Pressure Membrane Degasser + Gas-Liquid Separator |
| Safety Features | Real-Time Pressure Monitoring, Leak Detection, Eluent Reservoir Level Sensing, Auto-Shutdown Protocol |
| Consumables Monitoring | Column & Suppressor Usage Tracking with Auto-Recognition of New Units |
| Compliance Support | Designed for GLP/GMP environments |
| Brand | Beifen Sanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic Laboratory GC |
| Model | GC-2010F |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose / Forensic Toxicology |
| Oven Temperature Range | 420 °C |
| Maximum Ramp Rate | 40 °C/min |
| Cool-down Time | ~8 min (from 420 °C to 50 °C) |
| Carrier Gas Flow Range & Control | 0–800 mL/min |
| Carrier Gas Pressure Range & Control | 0–600 kPa |
| Injector Maximum Operating Temperature | 420 °C |
| Injector Pressure Setting Range | 0–600 kPa |
| Injector Total Flow Setting Range | 0–800 mL/min |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | BioLogic DuoFlow System |
| Maximum Pressure | 3500 psi (23 MPa) |
| Flow Rate Range | 0.01–80 mL/min (configurable via pump head selection) |
| UV Detection Wavelengths | Fixed 254/280 nm |
| Conductivity Range | 1–500 mS/cm |
| UV Sensitivity | 0.0001–2.0 OD |
| Fraction Collection Modes | Time-based (0.03–999 min), Drop-based (0–9999 drops), Volume-based, Large-volume (20 positions, up to 500 mL each) |
| Temperature-Controlled Operation | Compatible with chromatography cold cabinets (4–10 °C) |
| System Biocompatibility | Fully bio-inert fluidic path (PEEK, titanium, sapphire, fused silica) |
| Software Platform | BioLogic System Controller v5.x (Windows-based, FDA 21 CFR Part 11 compliant audit trail option) |
| Brand | Biochrom |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Biochrom 30+ |
| Price Range | USD 92,000 – 132,000 (based on exchange rate and configuration) |
| Instrument Type | Post-Column Derivatization System |
| Pump Flow Rate | 0–130 mL/hr |
| Maximum Pump Pressure | 45 MPa |
| Autosampler Injection Volume | 1–5000 µL |
| Autosampler Temperature Control | 4 °C to ambient, continuously adjustable |
| Post-Column Reactor Temperature Range | 40–145 °C |
| Detection Wavelengths | 570 nm and 440 nm (dual-wavelength, self-calibrating, parallel signal output with summation capability) |
| Flow Cell Volume | 8 µL |
| Brand | Biostep |
|---|---|
| Origin | Germany |
| Model | AS30 |
| Instrument Type | Thin-Layer Chromatography (TLC) Sample Spotter |
| Spotting Method | Non-contact spray spotting with programmable overlap capability |
| Wavelength Accuracy | ±0.5 nm |
| Wavelength Repeatability | <0.2 nm |
| Stage Dimensions | 500 × 380 × 180 mm |
| Spotting Speed | 3–120 s/µL (solvent-dependent) |
| Minimum Spotting Volume | 0.1 µL |
| Volume Range Options | 0.1–10 µL and 0.1–100 µL |
| Spotting Precision | ±0.5 nL |
| Programmable Methods | Up to 10 stored protocols |
| Sample Capacity (optional autosampler) | 144 vials |
| Brand | Biostep |
|---|---|
| Origin | Germany |
| Model | CD60 |
| Instrument Type | HPTLC Densitometer |
| Operation Mode | Fully Automated |
| Detection Modes | Absorption, Reflection, Fluorescence, Transmission |
| Wavelength Range | 190–900 nm |
| Light Sources | Deuterium Lamp, Tungsten-Halogen Lamp, Mercury Lamp |
| Monochromator | Stepper Motor-Driven Holographic Grating (1200 lines/mm) |
| Spectral Bandwidth | 5–260 nm |
| Wavelength Accuracy | < ±0.1 nm |
| Wavelength Repeatability | < ±0.2 nm |
| Minimum Spatial Resolution | 0.025 mm |
| Imaging Wavelength Range | 190–900 nm |
| Sample Stage Dimensions | 265 × 200 mm |
| Scan Speed | 20 mm/s |
| Brand | Biostep |
|---|---|
| Origin | Germany |
| Model | SG1 / DS20 |
| Spray Method | Programmable, Quantitative, Region-Specific Aerosol Deposition |
| Droplet Size | 1–10 µm |
| Spray Platform Area | 20 × 20 mm |
| Scan Speed | 50–200 mm/s |
| Wavelength Range | 2–4 mm (Note: This value is physically inconsistent with optical spectroscopy |
| likely refers to spray nozzle orifice diameter — corrected to “Nozzle Orifice | 2–4 mm”) |
| Light Sources | Deuterium lamp, Tungsten-halogen lamp, Mercury lamp |
| Wavelength Reproducibility | < 0.2 nm (applicable to integrated UV/Vis detection module, not spray function) |
| Compliance | GxP-ready software architecture with audit trail capability |
| Brand | Biostep |
|---|---|
| Origin | Germany |
| Model | DD80 |
| Instrument Type | Automated TLC Imaging & Densitometry System |
| Operation Mode | Fully Automatic |
| Detection Mode | Low-Fluorescence Substance Imaging |
| Wavelength Options | 254 nm and 366 nm UV |
| Light Sources | White LED, UV Fluorescent Lamps, UV LEDs |
| Imaging Sensor | 24-Megapixel Full-HD Digital Camera |
| Spectral Bandwidth Management | Auto Background Correction & Real-Time Image Optimization |
| Wavelength Accuracy | ±0.1 nm |
| Wavelength Repeatability | ±0.1 nm |
| Spatial Resolution | 7560-pixel RGB + IR Photometric Detection System |
| Focusing Mechanism | 19-Point Cross-Hair Autofocus Array |
| Stage Dimensions | 400 × 500 × 440 mm (W × D × H) |
| Frame Rate | 50 fps Continuous Capture |
| Brand | Biotage |
|---|---|
| Origin | Sweden |
| Model | Isolera Dalton 2000 |
| Application Level | Laboratory |
| Instrument Type | Medium-to-Low Pressure Preparative Liquid Chromatography System |
| Flow Rate Range | 1–200 mL/min |
| Flow Accuracy | RSD ≤ 0.5% |
| Flow Precision | RSD ≤ 0.2% |
| Maximum Operating Pressure | 145 psi |
| Wavelength Accuracy | ≤ ±1 nm |
| Wavelength Repeatability | 0.1 nm |
| Baseline Noise | ≤ 2 × 10⁻⁵ AU (peak-to-peak, methanol, 1 mL/min, 254 nm, 20 °C) |
| Data Acquisition Rate | 10 Hz |
| Mass Range | m/z 80–2000 |
| Ionization Modes | Simultaneous Positive/Negative APCI (ESI optional) |
| Brand | Biotage |
|---|---|
| Origin | Sweden |
| Model | Isolera LS |
| Application Level | Laboratory-scale |
| Instrument Type | Medium-to-Low Pressure Preparative Liquid Chromatography |
| Flow Rate Range | 50–500 mL/min |
| Flow Accuracy | RSD ≤ 0.5% |
| Flow Precision | RSD ≤ 0.2% |
| Maximum Operating Pressure | 145 psi (10 bar) |
| Wavelength Range | 200–400 nm (standard UV), optional 200–800 nm (UV-Vis) |
| Wavelength Reproducibility | ±0.1 nm |
| Baseline Noise | ≤2×10⁻⁵ AU (peak-to-peak, methanol, 1 mL/min, 254 nm, 20 °C) |
| Data Acquisition Rate | 10 Hz |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Imported |
| Model | Pure Essential System |
| Application Level | Laboratory Grade |
| Instrument Type | Medium-to-Low Pressure Preparative LC |
| Flow Rate Range | 0–300 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision | ±1% at 5–250 mL/min |
| Maximum Pressure | 50 bar |
| UV Wavelength Options | Fixed wavelengths at 254, 275, 325, and 365 nm |
| Brand | CAMAG |
|---|---|
| Origin | Switzerland |
| Model | ADC 3 |
| Instrument Type | Automatic Thin-Layer Chromatography (TLC) Development System |
| Operation Mode | Fully Automated |
| Sample Format | HPTLC plates up to 20 × 10 cm |
| Chamber Configuration | Dual-saturation chambers with integrated RH control |
| Compliance | cGMP/GLP, FDA 21 CFR Part 11 compliant |
| Software Control | visionCATS v3.x or later |
| Brand | CAMAG |
|---|---|
| Origin | Switzerland |
| Model | AMD 2 |
| Instrument Type | Thin-Layer Chromatography (TLC) Multiple Development System |
| Compliance | GLP/GMP-Compliant |
| Control | Programmable, CCD-Monitored |
| Solvent Capacity | Up to 5 solvents |
| Development Stages | Multi-step, Gradient Elution Capable |
| Max. Separation Density | ~40 components within 80 mm |
| Automation Level | Fully Automated Pre-saturation, Development, Drying |
| Brand | CAMAG |
|---|---|
| Origin | Switzerland |
| Model | ATS 4 |
| Instrument Type | Automatic Thin-Layer Chromatography Sampler |
| Sampling Modes | Contact (spot) and Non-contact Pneumatic Spray (band/square) |
| Sample Volume Range | 100 nL – 1 mL |
| Precision | ±1 nL / ±2 nL / ±10 nL (for 10 µL / 25 µL / 100 µL syringes) |
| Plate Capacity | Up to 20 × 20 cm, thickness up to 4 mm |
| X-axis Resolution | 0.1 mm/step (80 steps/mm), travel 5–195 mm |
| Y-axis Resolution | 0.1 mm/step (40 steps/mm), travel 5.0–195.0 mm |
| Sample Carrier | 66 × 2 mL vials (12 × 32 mm) or optional 96-well microtiter plate |
| Operating Pressure | 4–6 bar (65–87 psi), compressed air or nitrogen |
| Gas Flow Rate | 0.2–0.3 L/min (spot mode) |
| Integrated Heating Function | Yes |
| Syringe Options | 10 µL, 25 µL, 100 µL |
| Onboard Microprocessor Control | Yes |
| Software Interface | winCATS v1.4.12 or higher |
| Brand | CAMAG |
|---|---|
| Origin | Switzerland |
| Model | BioLuminizer® 2 |
| Instrument Type | TLC Imaging System |
| Detector Technology | Cooled CCD with 65% Quantum Efficiency |
| Data Depth | 16-bit |
| Pixel Resolution | High Spatial Resolution (Optimized for TLC Plate Detail Capture) |
| Application Focus | Bioluminescent Bioautography Coupled with Planar Chromatography |
| Brand | CAMAG |
|---|---|
| Origin | Switzerland |
| Model | Derivatizer |
| Operation Mode | Automatic |
| Instrument Type | Preparative Thin-Layer Chromatography System |
| Compliance | Designed for GLP-compliant laboratories |
| Solvent Compatibility | All conventional organic and aqueous solvents |
| Reagent Consumption | ~3 mL for 20 × 10 cm plates, ~4 mL for 20 × 20 cm plates |
| Enclosure | Sealed, fume-controlled chamber |
| Brand | CAMAG |
|---|---|
| Origin | Switzerland |
| Model | HPTLC PRO |
| Instrument Type | Preparative TLC System |
| Operation Mode | Fully Automatic |
| Sample Capacity | Up to 75 samples per run |
| Plate Capacity | Up to 5 TLC plates simultaneously |
| Solvent Systems | Up to 3 different developing solvents in one sequence |
| Software Compliance | FDA 21 CFR Part 11 compliant |
| Module Dimensions | 384 × 550 × 510 mm (W × D × H) |
| Brand | CAMAG |
|---|---|
| Origin | Switzerland |
| Model | Linomat 5 |
| Instrument Type | Thin-Layer Chromatography (TLC) Sample Spotter |
| Regulatory Compliance | IQ/OQ Qualified |
| Software Integration | visionCATS v3.x or later |
| Application Environment | GLP/GMP-Compliant Laboratories |
| Brand | CAMAG |
|---|---|
| Origin | Switzerland |
| Kit Type | Standard TLC Basic Toolset |
| Application | Preparative and Analytical TLC |
| Compliance | Designed to Support ASTM D7925, ISO 17025–Compliant Workflows |
| Software Integration | Compatible with CAMAG VisionCats (Optional) |
| Brand | CAMAG |
|---|---|
| Origin | Switzerland |
| Model | TLC Scanner 4 |
| Measurement Modes | Reflectance Absorption, Reflectance Fluorescence, Transmission Absorption, Transmission Fluorescence |
| Wavelength Range | 190–900 nm |
| Light Sources | Deuterium Lamp, Tungsten-Halogen Lamp, High-Pressure Mercury Lamp (automatically switchable) |
| Wavelength Reproducibility | < 0.2 nm |
| Minimum Spatial Resolution | 25 µm |
| Sample Stage Dimensions | 200 × 200 mm |
| Scanning Speed | 1–100 mm/s |
| Regulatory Compliance | Fully compliant with FDA 21 CFR Part 11 for electronic records and signatures |
| Brand | CAMAG |
|---|---|
| Origin | Switzerland |
| Model | TLC Visualizer 3 |
| Light Sources | 254 nm short-wave UV (epi-illumination), 366 nm long-wave UV (epi-illumination), white light (epi-illumination and trans-illumination) |
| Camera Sensor | High-resolution industrial CMOS |
| Software Platform | visionCATS v3.x or later |
| Compliance | Designed for GLP-compliant laboratories |
| Brand | CAMAG |
|---|---|
| Origin | Switzerland |
| Model | TLC-MS Interface 2 |
| Instrument Type | TLC–MS Coupling Interface |
| Compatibility | Universal LC-MS Systems (ESI, APCI, MALDI sources) |
| Operation Mode | Online and Offline Elution |
| Solvent Consumption | Low (≤ 200 µL per band) |
| Positioning Accuracy | ≤ ±50 µm |
| Washout Function | Integrated reverse-flow purge to prevent channel clogging |
| Sample Recovery | Direct collection into vials (1.5 mL or 2 mL) for downstream analysis (NMR, FTIR, ESI-MS, MALDI-MS) |
| Brand | -- |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | Capel-205 |
| Pricing | Upon Request |
| Instrument Type | Capillary Electrophoresis (CE) System |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Cathodeon |
| Pricing | Available Upon Request |
| Brand | CEM |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | Prodigy 2.0 |
| Application Level | Laboratory Grade |
| Instrument Type | High-Pressure Preparative Liquid Chromatograph |
| Flow Rate Range | 4–250 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤1% |
| Maximum Pressure | 300 bar |
| Wavelength Range | 190–500 nm |
| Wavelength Repeatability | ±3 nm |
| Data Acquisition Frequency | 50 Hz |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | HS-1000 |
| Instrument Type | Fast Liquid Chromatography System |
| Flow Rate Range | 0.1–100.0 mL/min (0.1 mL/min increment) |
| Maximum Operating Pressure | ≤20 MPa |
| Fraction Collection Options | F1–F4 standard tube racks (13 mm, 15 mm, 18 mm, 25 mm OD), F5 conical flask rack (up to 100 mL |
| Sample Injection Volume Range | up to 1 L |
| Temperature Control | Ambient only |
| Wavelength Range | Dual-channel UV-Vis detection at 200–400 nm and 200–800 nm (simultaneously selectable) |
| Data Acquisition Rate | Not specified |