Cleaning & Disinfection Equipment
Filter
Showing 1–30 of 301 results
| Brand | Abner |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Instrument Category | Vacuum Glove Box |
| Application Type | Production-Scale Glove Box |
| Chamber Material | Stainless Steel (304) |
| Dimensions (L×W×H) | 1120 × 740 × 900 mm |
| Condition | Refurbished, 98% New |
| Brand | AIRSENSE |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | COOLJETTER |
| Quotation | Available Upon Request |
| Dimensions | Not Applicable (Wall/Ceiling-Mounted Fixed Installation) |
| Reservoir Capacity | Not Specified |
| 雾化输出速率 | Not Specified |
| Sensing Distance | Not Specified |
| Brand | AIRSENSE |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DRY-FOG |
| Quotation | Upon Request |
| Dimensions | Not Applicable (Wearable, Ergonomic Design) |
| Reservoir Capacity | Integrated Dual-Compartment Cartridge System (Compatible with Standard 1–2 L Disinfectant Cartridges) |
| 雾 Output Rate | ≤2 L/h (Adjustable via Microprocessor-Controlled Pneumatic Atomization) |
| Detection Range | 0–30 cm (Infrared Proximity Sensor, Auto-Triggered Dispensing) |
| Brand | AIRTECH |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ACP-894 (A/B/C/D) |
| Instrument Type | Non-thermal Plasma + UVC Disinfection System |
| Intended Use | Medical & Laboratory Environments |
| Sterilization Efficacy | ≥99.9% reduction of Staphylococcus albus, Escherichia coli, Staphylococcus aureus, and Poliovirus (per Chinese Disinfection Technical Specifications, 2002 Edition) |
| Disinfection Mechanism | Synergistic Non-thermal Plasma + 254 nm UVC + HEPA Filtration + Photocatalytic Oxidation (TiO₂) |
| Airflow Rate | 640 / 470 / 250 m³/h (High/Standard/Silent Mode) |
| Noise Level | ≤54 / ≤45 / ≤38 dB(A) |
| Power Supply | AC 220 V, 1Φ, 50 Hz |
| Rated Power | 100 / 80 / 60 W |
| Dimensions (W×D×H) | 890 × 400 × 1500 mm |
| Net Weight | 55 kg |
| Applicable Volume | ≤80 m³ |
| Primary Germicidal Agents | Low-pressure mercury UVC lamp (254 nm), Class H13 HEPA filter (≥99.95% @ 0.3 µm), TiO₂-based photocatalyst, and dielectric barrier discharge (DBD) plasma generator |
| Brand | Aitesen |
|---|---|
| Origin | Jiangsu, China |
| Model | RSS-L1 |
| Type | Benchtop Sterilizer |
| Max Temperature | 0–150 °C (±0.1 °C) |
| Chamber Volume Capacity | 10–2000 mL |
| Max Working Pressure | 0.3 MPa |
| Total Power | 7.5 kW |
| Sample Capacity | 1–10 vessels |
| Temperature Sensors | ≥3 independent RTD probes |
| Output Parameters | Temperature, Pressure, F₀, Time, Rotation Speed, Steam Flow (where applicable) |
| Brand | Alalis |
|---|---|
| Origin | USA |
| Model | AS03 |
| Capacity | 3 L |
| Ultrasonic Frequency | 40 kHz |
| Ultrasonic Power | 100 W |
| Power Adjustment | Yes, 40–100% |
| Timer Range | 1–199 min |
| Heating Function | No |
| Drain Valve | No |
| Lid (Noise Reduction) | No |
| Tank Material | 304 Stainless Steel |
| Display | Capacitive Touchscreen |
| Safety Features | Built-in Leak Protection, Overload & Overheat Protection |
| Dimensions (W×D×H) | 301 × 163 × 242 mm |
| Internal Tank Size (W×D×H) | 240 × 140 × 100 mm |
| Brand | alalis |
|---|---|
| Origin | USA |
| Model | AS03T |
| Capacity | 3 L |
| Ultrasonic Frequency | 40 kHz |
| Ultrasonic Power | 100 W |
| Power Adjustment Range | 40–100% |
| Temperature Control Range | 20–65 °C |
| Timer Range | 1–199 min |
| Sound-Dampening Lid | Yes |
| Drain Valve | No |
| Heating Power | 90 W |
| Internal Dimensions (L×W×H) | 240 × 140 × 100 mm |
| External Dimensions (L×W×H) | 301 × 163 × 242 mm |
| Display | Touchscreen |
| Leak Protection | Yes |
| Tray | Included |
| Brand | Alalis |
|---|---|
| Origin | USA |
| Model | AS06 |
| Capacity | 6 L |
| Ultrasonic Frequency | 40 kHz |
| Ultrasonic Power | 150 W |
| Power Adjustment | Yes, 40–100% |
| Timer Range | 1–199 min |
| Heating Function | No |
| Drain Valve | No |
| Sound-Dampening Lid | No |
| Tank Material | 304 Stainless Steel |
| Display | Capacitive Touchscreen |
| Safety Features | Built-in Leak Protection, Overload & Overheat Protection |
| Dimensions (W×D×H) | 362 × 180 × 305 mm |
| Internal Tank Size (W×D×H) | 300 × 150 × 150 mm |
| Brand | alalis |
|---|---|
| Origin | USA |
| Model | AS06T |
| Capacity | 6 L |
| Ultrasonic Frequency | 40 kHz |
| Ultrasonic Power | 150 W |
| Power Adjustment | Yes, 40–100% |
| Temperature Control | Yes, 20–65 °C |
| Timer Range | 1–199 min |
| Sound-Dampening Lid | Included |
| Drain Valve | Not equipped |
| Brand | Alalis |
|---|---|
| Origin | USA |
| Model | AS10 |
| Capacity | 10 L |
| Ultrasonic Frequency | 40 kHz |
| Ultrasonic Power | 200 W |
| Power Adjustment | Yes (40–100%) |
| Timer Range | 1–199 min |
| Drain Valve | Yes |
| Tank Material | 304 Stainless Steel |
| Display | Capacitive Touchscreen |
| Safety Features | Built-in Leak Protection, Overload & Overheat Protection |
| Compliance | Meets ASTM D2607 and ISO 13850 for laboratory ultrasonic cleaning systems |
| Software | Non-PC-based embedded control with parameter memory retention after power loss |
| Brand | alalis |
|---|---|
| Origin | USA |
| Model | AS10T |
| Capacity | 10 L |
| Ultrasonic Frequency | 40 kHz |
| Ultrasonic Power | 200 W |
| Power Adjustment | Yes (40–100%) |
| Temperature Control | Yes (20–65 °C) |
| Timer Range | 1–199 min |
| Sound-Dampening Lid | Included |
| Drain Valve & Fill Port | Integrated |
| Brand | Alalis |
|---|---|
| Origin | USA |
| Model | AS15 |
| Capacity | 15 L |
| Ultrasonic Frequency | 40 kHz |
| Ultrasonic Power | 350 W |
| Power Adjustment | Yes, 40–100% |
| Timer Range | 1–199 min |
| Drain Valve | Yes |
| Noise-Reduction Lid | No |
| Heating Function | Not equipped |
| Tank Material | 304 Stainless Steel |
| Display | Capacitive Touchscreen |
| Safety Features | Built-in leak protection, overheat & overload protection |
| Compliance | Meets ASTM D2604 and ISO 13847 requirements for ultrasonic cleaning validation |
| Brand | alalis |
|---|---|
| Origin | USA |
| Model | AS15T |
| Capacity | 15 L |
| Ultrasonic Frequency | 40 kHz |
| Ultrasonic Power | 350 W |
| Power Adjustment | Yes (40–100%) |
| Temperature Control | Yes (20–65 °C) |
| Timer Range | 1–199 min |
| Sound-Dampening Lid | Included |
| Drain & Fill Ports | Equipped |
| Construction | 304 Stainless Steel Tank |
| Display | Capacitive Touchscreen Interface |
| Safety Features | Leak Detection, Overheat & Overload Protection |
| Compliance | Meets ASTM D2276, ISO 13843, and IEC 61000-6-3 for laboratory-grade ultrasonic cleaning systems |
| Brand | alalis |
|---|---|
| Origin | USA |
| Model | AS20 |
| Capacity | 20 L |
| Ultrasonic Frequency | 40 kHz |
| Ultrasonic Power | 400 W |
| Power Adjustment | Yes, 40–100% |
| Timer Range | 1–199 min |
| Drain Valve | Yes |
| Tank Material | 304 Stainless Steel |
| Display | Capacitive Touchscreen Interface |
| Safety Features | Built-in Leak Protection, Overload & Overheat Protection |
| Compliance | Meets ASTM D2607 (Ultrasonic Cleaning Performance Testing), ISO 13485 (Medical Device Manufacturing Support), and GLP-relevant operational traceability requirements |
| Brand | Alalis |
|---|---|
| Origin | USA |
| Model | AS20T |
| Capacity | 20 L |
| Ultrasonic Frequency | 40 kHz |
| Ultrasonic Power | 400 W |
| Power Adjustment Range | 40–100% |
| Temperature Control Range | 20–65 °C |
| Timer Range | 1–199 min |
| Sound-Dampening Lid | Yes |
| Drain & Fill Ports | Yes |
| Construction | 304 Stainless Steel Tank |
| Heating Power | 560 W |
| Display | Capacitive Touchscreen |
| Safety Features | Leak Protection, Overheat & Overload Protection, Auto Diagnostic Function |
| Dimensions (Overall) | 584 × 327 × 327 mm |
| Tank Internal Dimensions | 500 × 300 × 150 mm |
| Compliance | Meets ASTM D2603, ISO 13847, and IEC 61000-6-3 for laboratory ultrasonic equipment |
| Brand | Alalis |
|---|---|
| Origin | USA |
| Model | AS30 |
| Capacity | 30 L |
| Ultrasonic Frequency | 40 kHz |
| Ultrasonic Power | 500 W |
| Power Adjustment | Yes, 40–100% |
| Timer Range | 1–199 min |
| Drain Valve | Yes |
| Tank Material | 304 Stainless Steel |
| Display | Capacitive Touchscreen |
| Safety Features | Built-in Leak Protection, Overload & Overheat Protection |
| Dimensions (W×D×H) | 584 × 327 × 375 mm |
| Internal Tank Size (W×D×H) | 500 × 300 × 200 mm |
| Compliance | Meets ASTM D4296, ISO 13845, and general laboratory equipment safety requirements for non-heated ultrasonic cleaning systems |
| Brand | alalis |
|---|---|
| Origin | USA |
| Model | AS30T |
| Capacity | 30 L |
| Ultrasonic Frequency | 40 kHz |
| Ultrasonic Power | 500 W |
| Power Adjustment Range | 40–100% |
| Temperature Control Range | 20–65 °C |
| Timer Range | 1–199 min |
| Sound-Dampening Lid | Yes |
| Drain & Fill Fitting | Yes |
| Brand | Allentown |
|---|---|
| Origin | Canada |
| Model | C500 |
| Type | Cabinet-style, microprocessor-controlled laboratory cage and bottle washer |
| Construction | Fully welded 316 stainless steel chamber and door with satin finish |
| Spray system | Three hydraulically driven rotating spray arms (left/right/top) |
| Temperature control | Programmable multi-stage heating (wash, rinse, final rinse) with ±1°C stability |
| User interface | 7-inch TFT color touchscreen with 8 pre-programmed cycles |
| Data logging | Optional CF card or Ethernet connectivity for full cycle traceability |
| Safety | Emergency stop button, door interlock, <80 dB(A) operational noise |
| Compliance | Designed to support GLP/GMP workflows |
| Loading capacity | C520 — up to 48 standard mouse cages or 6 rat cages |
| Optional accessories | Bottle washing cart (BWC), VHSS high-capacity rack system, pH neutralization unit, ActivView remote monitoring integration, thermal printer, RS485 interface, factory diagnostic port |
| Brand | Allentown |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Equinox |
| Pricing | Upon Request |
| Brand | Allentown |
|---|---|
| Origin | Canada |
| Model | T200 |
| Construction | Fully Stainless Steel Modular Frame |
| Drive System | Conveyor with Nylon Guide Rails |
| Noise Level | <85 dB(A) |
| Control Interface | 5-inch TFT Color Touchscreen Microprocessor |
| Compliance | Designed for GLP/GMP-aligned laboratory animal facilities |
| Optional Features | Forced-air curtain nozzles, heat recovery exchanger, pH neutralization system, Ethernet connectivity, Activ monitoring integration, automated loading/unloading interface |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | GBS-5000B |
| Convection Type | Natural Convection |
| Temperature Range | 100°C to 300°C |
| Temperature Control Accuracy | ≤ ±5°C |
| Temperature Uniformity | ≤ ±5°C |
| Heating Power | 250 W |
| Internal Chamber Dimensions (W×D×H) | 145 mm × 130 mm × 215 mm |
| Bead Capacity | 300 g (Φ3 mm glass beads) |
| Warm-up Time to 300°C | ≤ 25 min |
| Net Weight | 2.5 kg |
| Voltage Input | AC 100–120 V / 200–240 V, 50/60 Hz |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | HM-3000A |
| Maximum Operating Temperature | 825 °C ± 50 °C |
| Heating Power | 170 W |
| Chamber Dimensions (W×D×H) | 98 mm × 185 mm × 190 mm |
| Max. Sample Diameter | Φ14 mm |
| Heating Zone Length | 150 mm |
| Net Weight | 1.3 kg |
| Input Voltage | AC 220 V / AC 120 V, 50/60 Hz, 1 A |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | HM-3000E |
| Convection Type | Natural Convection |
| Operating Temperature Range | 825°C ± 50°C |
| Temperature Control Accuracy | ≤ ±5°C |
| Temperature Uniformity | ≤ ±5°C |
| Heating Power | 320 W |
| Internal Dimensions (W×D×H) | 100 × 153 × 280 mm |
| Max. Sample Diameter | Φ35 mm |
| Heating Zone Length | 100 mm |
| Net Weight | 1.6 kg |
| Ambient Operating Temperature | −10°C to 50°C |
| Relative Humidity | ≤90% RH |
| Altitude Limit | Unrestricted |
| Brand | ALP |
|---|---|
| Origin | Japan |
| Model | CL-32L / CL-40M |
| Chamber Volume | 54 L (CL-32L), 85 L (CL-40M) |
| Max Operating Temperature | 140 °C (CL-32L), 137 °C (CL-40M) |
| Max Working Pressure | 0.27 MPa (CL-32L), 0.25 MPa (CL-40M) |
| Sterilization Temp Range | 40–140 °C (CL-32L), 40–137 °C (CL-40M) |
| Melting/Insulation Range | 40–99 °C / 40–60 °C |
| Cycle Time | Sterilization/Melting: 0–600 min or continuous |
| Insulation | 0–2880 min |
| Drying Temp Range | 60–180 °C |
| Drying Timer | 0–5940 min or continuous |
| Control System | Microprocessor-based with graphical LCD interface |
| Safety Compliance | ASME BPVC Section VIII Div. 1, PED 2014/68/EU, ISO 17665-1, GB/T 30690–2014, China Special Equipment Manufacturing License (Pressure Vessel) |
| Brand | ALP |
|---|---|
| Origin | Japan |
| Model | CLG-32L / CLG-40M |
| Chamber Dimensions (Ø × Depth) | 320 × 676 mm (32L) / 400 × 672 mm (40M) |
| Chamber Volume | 54 L / 85 L |
| Sterilization Temp Range | 100–140 °C (CLG-32L), 100–137 °C (CLG-40M) |
| Dissolution/Heating Temp Range | 40–99 °C / 40–60 °C |
| Max Operating Pressure | 0.270 MPa / 0.250 MPa |
| Cycle Time | Sterilization/Dissolution: 0–10 h |
| Holding | 0–48 h |
| Programmable Cycles | 10 stored protocols with mode & data logging |
| Vacuum System | Triple-pulse pre-vacuum with high-capacity vacuum pump |
| Air Filtration | 0.2 µm hydrophobic filter for heated air drying |
| Drying Method | Vacuum-assisted hot-air drying post-sterilization |
| Safety Certification | PED 97/23/EC compliant |
| Construction | Inner chamber – SUS304 stainless steel |
| Power Supply | AC 220–240 V, 1-phase, 50/60 Hz |
| Rated Current | 12 A |
| Heating Power | 2.6 / 2.8 / 2.9 kW (model-dependent) |
| Dimensions (W×D×H) | 550 × 550 × 950 mm (CLG-32L) / 620 × 650 × 990 mm (CLG-40M) |
| Weight | 65 kg / 83 kg |
| Control Interface | Backlit LCD display with real-time monitoring of temperature, pressure, phase status, and elapsed time |
| Door Mechanism | Central lever lock with automatic interlock, motor-assisted hinge, and power-dependent electronic safety lock |
| Cooling | Active rapid cooling to <80 °C post-cycle |
| Drainage | Front-mounted manual drain valve and accessible front-positioned waste tank |
| Optional | Integrated product temperature probe port (probe sold separately) |
| Compliance | Meets IEC 61000-6-3 (EMC) and IEC 61000-6-4 (emission) standards |
| Brand | Alphavita |
|---|---|
| Origin | Liaoning, China |
| Model | MVS-3780 |
| Chamber Dimensions (Ø × H) | 370 mm × 795 mm |
| Chamber Volume | 83 L |
| External Dimensions (W × D × H) | 550 × 550 × 1050 mm |
| Net Weight | 83 kg |
| Power Rating | 3100 W |
| Electrical Interface | 16 A plug |
| Safety Compliance | Dual dry-run protection, overcurrent & leakage protection, pressure relief valve, four-point interlock system, chamber overpressure alarm, 98% air removal efficiency |
| Brand | Alphavita |
|---|---|
| Origin | Liaoning, China |
| Model | MVS-60 |
| Sterilization Chamber Dimensions | Φ370 × 610 mm |
| External Dimensions | 550 × 550 × 820 mm |
| Chamber Volume | 55 L |
| Vessel Material | S30408 stainless steel (GB/T 24511–2017), 3 mm wall thickness |
| Design Standard | GB 150–2011 |
| Altitude Rating | Certified for operation up to 4000 m ASL |
| Safety Features | Dual dry-run protection, overcurrent protection, earth-leakage detection, four-point interlocked door system, spring-loaded safety valve, real-time overpressure alarm |
| Exhaust System | Pressure-stabilized air removal (98% air displacement), six-stage adjustable exhaust rate & temperature |
| Cooling | High-capacity external cooling fan (optional internal fan), variable-speed cooling control |
| Control Modes | Four pre-programmed cycles + user-defined program memory + pre-heating cycle + time-scheduled start |
| Brand | Alphavita |
|---|---|
| Origin | Liaoning, China |
| Model | MVS-83 |
| Instrument Type | Vertical Autoclave |
| Max Temperature | 135 °C |
| Max Pressure | 0.3 MPa |
| Chamber Dimensions (W×H) | 370 mm × 795 mm |
| External Dimensions (W×D×H) | 600 mm × 620 mm × 1005 mm |
| Chamber Volume | 83 L (≥75 L effective) |
| Power Rating | 4200 W |
| Net Weight | 90 kg |
| Safety Class | Class I Pressure Vessel |
| Manufacturing License | DI-Class |
| Temperature Sensor | PT100 |
| Pressure Gauge Range | −0.1 to 0.5 MPa |
| Safety Valve Set Point | 0.28 MPa |
| Cooling System | Dual-Cooling (axial + shaded-pole fans + condenser) |
| Exhaust | Adjustable 5-level downward exhaust |
| Operating Altitude Range | 0–3000 m |
| Timer Range | 0–4320 min (1 min resolution) |
| Brand | Alphavita |
|---|---|
| Model | MVS-84 |
| Chamber Volume | 83 L |
| External Dimensions (W×D×H) | 600 × 620 × 1005 mm |
| Internal Dimensions (Ø × H) | Ø370 × 795 mm |
| Net Weight | 100 kg |
| Power Rating | 3100 W |
| Construction Material | S30408-2B stainless steel (3 mm thickness) |
| Compliance | YY/T 1007–2018, GB 150, GB/T 24511–2017 |
| Safety Features | Dual dry-run protection, overcurrent protection, earth leakage protection, quadruple mechanical/electrical interlock, spring-loaded safety valve, chamber overpressure alarm |
| Operating Altitude | Up to 4000 m ASL |
| Power Interface | 16 A standard plug |