| Brand | Femto Science |
|---|---|
| Origin | South Korea |
| Model | CUTE |
| Chamber Dimensions | 140 mm × 200 mm × 110 mm |
| Power Output | Up to 100 W (adjustable, 20–100 kHz RF frequency) |
| Vacuum System | 80 L/min pumping speed, ultimate vacuum ≤ 1 × 10⁻³ Torr, pressure range: atmospheric to 5 × 10⁻⁵ Torr |
| Gas Control | 1 standard MFC-controlled inlet (0–100 sccm, ±1% FS accuracy), 2 additional blank ports for future expansion |
| User Interface | Color TFT touchscreen with graphical workflow interface |
| Operation Modes | Semi-automatic and fully programmable (up to 10 stored recipes, each supporting up to 10 sequential process steps) |
| Chamber Material | Anodized aluminum alloy |
| Operator Levels | 2-tier access control (operator & administrator) |
| Brand | Filtra |
|---|---|
| Origin | Spain |
| Model | U-Series |
| Capacity | 9 L / 12 L |
| Construction | AISI 304 Stainless Steel Tank |
| Heating | Adjustable Thermostat (Room Temp to 80 °C) |
| Timer | Digital, 0–30 min |
| Drain Outlet | Yes |
| Dual-Level Operation | Yes |
| Power Supply | 230 V AC, 50/60 Hz |
| Certifications | CE, RoHS |
| Compliance | Designed for GLP-compliant laboratory environments |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | ZM-100A |
| Instrument Type | Vertical Sterilizer |
| Max Temperature | 135 °C |
| Max Pressure | 0–0.22 MPa (Saturated Steam Pressure) |
| Sterilization Chamber Dimensions | Ø400 mm × 500 mm (H) |
| External Dimensions | Ø500 mm × 560 mm (H) |
| Chamber Volume | 50 L |
| Safety Relief Pressure | 0.23 MPa |
| Back-Pressure Range | 0.14–0.165 MPa |
| Water Replenishment Pressure | ≥0.32 MPa |
| Timer Range | 1–99.59 min |
| Power Supply | AC 220 V, 50 Hz |
| Rated Power | 4.5 kW ±10% |
| Compliance Standards | GB 150.1–2011, GB/T 10004–2008, GB 4793.4–2001, YY 1007–2010 |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | ZM-100B |
| Instrument Type | Vertical |
| Max Temperature | 135 °C |
| Max Pressure | 0–0.22 MPa (Saturated Steam Pressure) |
| Sterilization Chamber Dimensions | Ø400 mm × 500 mm (H) |
| External Dimensions | Ø500 mm × 560 mm (H) |
| Chamber Volume | 50 L |
| Safety Relief Pressure | 0.23 MPa |
| Back-Pressure Range | 0.14–0.165 MPa |
| Time Setting Range | 1–99.59 min |
| Power Supply | AC 220 V, 50 Hz |
| Rated Power | 4.5 kW ±10% |
| Compliance | GB 150.1–2011, GB/T 10004–2008, GB 4793.4–2001, YY 1007–2010 |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Equipment Type | Vertical Sterilizer |
| Model | ZM-100C |
| Max Temperature | 135 °C |
| Max Pressure | 0–0.22 MPa (saturated steam) |
| Chamber Dimensions | Ø400 mm × 500 mm (H) |
| External Dimensions | Ø500 mm × 560 mm (H) |
| Chamber Volume | 50 L |
| Safety Relief Pressure | 0.23 MPa |
| Counter-Pressure Range | 0.14–0.165 MPa |
| Timing Range | 1–99.59 min |
| Power Supply | AC 220 V, 50 Hz |
| Rated Power | 4.5 kW ±10% |
| Compliance | GB 150.1–2011, GB/T 10004–2008, GB 4793.4–2001, YY 1007–2010 |
| Origin | Germany |
|---|---|
| Distribution Model | Authorized Distributor |
| Import Status | Imported |
| Heating Power Range | 20–1000 W |
| Cleaning Medium | Pulsed Fiber Laser (1064 nm) |
| External Dimensions (L×W×D) | 50 × 50 × 70 cm (Mobile Configuration) |
| Cooling Method | Air-Cooled (≤600 W) |
| Control Interface | Touchscreen HMI |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GB12 |
| Pricing | Available Upon Request |
| Brand | Grant |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | UVR-M Series |
| Pricing | Available Upon Request |
| UV Radiation Source | 1 lamp (UVR-M) / 2 lamps (UVR-Mi) |
| UV Airflow Rate | 14 m³/hour |
| UV Irradiance | 18 mW/cm²/s (UVR-M) / 36 mW/cm²/s (UVR-Mi) |
| Timer Range | 1 minute – 24 hours or continuous operation |
| Display | LCD |
| Power Supply | 230 V AC, 125 VA (540 mA) for UVR-M / 110 W (0.5 A) for UVR-Mi |
| Weight | 3.4 kg |
| Wall Mount Bracket | Standard |
| UV Lamp Operational Indicator | Standard |
| Lamp Life Counter | Standard |
| Auto On/Off Switch | Standard |
| Lamp Fault Detection | Standard |
| Optional Accessory | UVR-S Mobile Tripod Stand |
| Origin | UK |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | XUB |
| Price | Upon Request |
| Capacity Options | 4.5–25 L |
| Ultrasonic Power | 100–400 W |
| Operating Frequency | 32–38 kHz |
| Temperature Range | Ambient +5°C to 70°C |
| Heating Power | 150–500 W |
| Frequency Modulation (LEAP) | Yes |
| Digital LCD Control | Yes |
| SD Card Data Logging | Yes |
| Drain Valve | BSP, 3/8" or 1/2" |
| Power Supply | 230 V AC |
| Brand | Grant |
|---|---|
| Origin | United Kingdom |
| Model | XUB5 / XUB10 / XUB12 / XUB18 / XUB25 |
| Capacity | 4.5–25 L |
| Ultrasonic Power | 100–400 W |
| Operating Frequency | 32–38 kHz |
| Temperature Range | Ambient +5 °C to 70 °C |
| Heating Power | 150–500 W |
| Control | Digital LCD with Menu-Driven Interface |
| Data Logging | SD Card with Digital Certification |
| Drain Valve | BSP (3/8" or 1/2") |
| Power Supply | 230 V AC |
| Origin | South Korea |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GUARDiON H2T |
| Dosage Volume | 5 L |
| Airflow Rate | 5 m³/min |
| Sterilization Chamber Capacity | 5 L (generator reservoir) |
| Vaporization Temperature | 25 °C |
| Dehumidification Setpoint | ≤30% RH |
| Filtration Efficiency | ≥99.9999% (HEPA + optional catalytic post-filter) |
| Sterilant | Aqueous hydrogen peroxide (7% w/w) |
| Log Reduction | ≥6-log (≥99.9999%) for Geobacillus stearothermophilus spores and enveloped/non-enveloped viruses |
| Brand | Haier Biomedical |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | HGYX-Y100 |
| Hydrogen Peroxide Delivery Rate | 1–10 mL/min |
| Maximum Vaporization Rate | 500 mL/min |
| Sterilization Cycle Time | <2 h |
| Log Reduction | >6-log (≥99.9999%) for Bacillus atrophaeus and Geobacillus stearothermophilus |
| Sterilization Chamber Compatibility | Up to 100 L (external equipment/volume-dependent) |
| Operating Voltage | 220 V AC |
| Power Consumption | 700 VA |
| Net/Gross Weight | 12/15 kg |
| Dimensions (W×D×H) | 300×300×350 mm |
| Packaging Dimensions (W×D×H) | 410×405×495 mm |
| Surface Finish | Electrostatic Epoxy Powder Coating |
| Compliance | ISO 14644-1 Class 5 compatible operation |
| Brand | Hannuo |
|---|---|
| Origin | Shanghai, China |
| Model | HN10-250C |
| Capacity | 10 L |
| Ultrasonic Frequencies | 25 kHz / 40 kHz |
| Ultrasonic Power | 250 W (fixed output) |
| Temperature Control | Yes (adjustable, digital display) |
| Timer Range | 1–99 min (digital LCD preset) |
| Lid | Acoustic-damping cover included |
| Drain | Manual valve |
| Construction | Stainless steel tank and housing |
| Compliance | Designed for GLP-aligned laboratory workflows |
| Software | Microcontroller-based embedded control system |
| Cumulative operating time counter | Up to 99,999 hours |
| Accessories | Stainless steel mesh basket and lid |
| Brand | Hannuo |
|---|---|
| Origin | Shanghai, China |
| Model | HN10-300C |
| Capacity | 10 L |
| Ultrasonic Frequencies | 25 kHz / 45 kHz |
| Ultrasonic Power | 300 W (0–100% adjustable) |
| Heating Function | Yes (temperature adjustable, 0–80 °C) |
| Timer Range | 1–99 min (digital display with cumulative operation time up to 99,999 h) |
| Construction | Stainless steel tank and housing |
| Lid | Sound-dampening cover included |
| Drain Valve | Manual |
| Compliance | Designed for GLP-compliant laboratory environments |
| Software Control | Microcontroller-based embedded system |
| Accessories | Stainless steel mesh basket included |
| Brand | Hannuo |
|---|---|
| Origin | Shanghai, China |
| Model | HN22-500C |
| Chamber Volume | 22.5 L |
| Heating Power | 500 W |
| Temperature Range | Ambient to 80 °C |
| Cleaning Medium | Aqueous Solutions |
| External Dimensions (L×W×D) | 500 × 300 × 150 mm |
| Frequency Options | 25 kHz / 45 kHz (switchable) |
| Ultrasonic Power Output | 0–100% adjustable |
| Display | LCD with timer memory and real-time temperature monitoring |
| Timer Range | 1–99 min |
| Cumulative Operating Hours Counter | up to 99,999 h |
| Construction | Stainless steel tank and housing |
| Brand | Hannuo |
|---|---|
| Origin | Shanghai, China |
| Model | HN3-120A |
| Capacity | 3 L |
| Ultrasonic Frequency | 40 kHz |
| Ultrasonic Power | 120 W |
| Power Adjustment | Fixed |
| Temperature Control Range | RT–80 °C |
| Timer Range | 1–99 min |
| Sound-Dampening Lid | Included |
| Drain Valve | Manual |
| Construction | Stainless Steel Tank & Housing |
| Control System | Microprocessor-Based Digital Display with Auto-Sweep Frequency |
| Brand | Hannuo |
|---|---|
| Origin | Shanghai, China |
| Model | HN30-800C |
| Capacity | 30 L |
| Ultrasonic Frequency | 25 / 45 kHz |
| Ultrasonic Power | 800 W (0–100% adjustable) |
| Heating Function | Yes (temperature adjustable, real-time digital display) |
| Timer Range | 1–99 min (digital LCD, cumulative operation time up to 99,999 h) |
| Construction | Stainless steel tank and housing |
| Lid | Sound-dampening cover included |
| Drain Valve | Manual |
| Compliance | Designed for GLP-compliant laboratory environments |
| Software Control | Microcontroller-based embedded system |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | BS280CD |
| Chamber Volume | 180 L |
| Heating Power | 6 kW |
| Maximum Wash Temperature | 93 °C |
| Compatible Cleaning Agents | Acidic & Alkaline Liquid Detergents |
| External Dimensions (L×W×D) | 875 (845) × 900 × 710 mm |
| Brand | Hanon |
|---|---|
| Model | BS580D |
| Chamber Volume | 360 L |
| Heating Power | 9 kW |
| Maximum Wash Temperature | 93 °C |
| Wash Solution Compatibility | Acidic & Alkaline Liquid Detergents |
| External Dimensions (L×W×D) | 1800 × 785 × 765 mm |
| Power Supply | 380 V / 50 Hz (3-phase) |
| Control System | Programmable Logic Controller (PLC) with Touchscreen Interface |
| Wash Cycle Duration | Adjustable (Typical Range: 25–60 min) |
| Water Consumption per Cycle | ≤ 80 L |
| Drainage Capacity | ≥ 20 L/min |
| Safety Certification | CE-compliant design, IP54-rated electrical enclosure |
| Material of Chamber | 316L Stainless Steel |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | GS300-L / GS300-H |
| Temperature Range | 100–300 °C |
| Temperature Control Accuracy | ±5 °C |
| Display Resolution | 1 °C |
| Heating Time (to 300 °C) | ≤25 min |
| Power Rating | 120 W (GS300-L) / 250 W (GS300-H) |
| Chamber Dimensions | Φ40 mm × 80 mm (L) / Φ40 mm × 140 mm (H) |
| Glass Bead Capacity | 150 g / 300 g |
| External Dimensions | 176 × 135 × 189.5 mm (L) / 176 × 135 × 249.5 mm (H) |
| Net Weight | 2.5 kg / 3.3 kg |
| Voltage | AC 220 V, 50–60 Hz |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HN-10A |
| Capacity | 10 L |
| Ultrasonic Frequency | 40 kHz |
| Ultrasonic Power | 300 W |
| Adjustable Power | Yes |
| Heating Function | Yes (20–80 °C) |
| Timer Range | 0–30 min |
| Sound-Dampening Lid | Included |
| Drain Valve | Manual |
| Construction | Stainless Steel Tank (304) |
| Dimensions (L×W×H) | 300 × 240 × 150 mm (tank) |
| Net Weight | 8.3 kg |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HN-10AL |
| Tank Capacity | 10 L |
| Internal Tank Dimensions | 300 × 240 × 150 mm |
| Ultrasonic Frequency | 40 kHz |
| Adjustable Ultrasonic Power | 40–100% (240 W nominal) |
| Heating Power | 250 W |
| Temperature Control Range | 20–80 °C |
| Timer Range | 0–30 min |
| Net Weight | 8.3 kg |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HN-14AL |
| Capacity | 14 L |
| Ultrasonic Frequency | 40 kHz |
| Ultrasonic Power | 300 W |
| Power Adjustment Range | 40–100% |
| Temperature Control Range | 10–80 °C |
| Timer Range | 0–30 min |
| Lid with Noise Reduction | Yes |
| Drain Valve | Manual |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HN-15A |
| Capacity | 15 L |
| Ultrasonic Frequency | 40 kHz |
| Ultrasonic Power | 360 W |
| Adjustable Power | Yes |
| Adjustable Heating Temperature | 20–80 °C |
| Adjustable Timer | 0–30 min |
| Sound-Dampening Lid | Included |
| Manual Fill/Drain | Yes |
| Construction | Stainless Steel Tank |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HN-15AL |
| Tank Capacity | 15 L |
| Ultrasonic Frequency | 40 kHz |
| Ultrasonic Power Output | 360 W |
| Power Adjustment Range | 40–100% |
| Heating Power | 400 W |
| Temperature Control Range | 20–80 °C |
| Timer Range | 0–30 min |
| Internal Tank Dimensions (L×W×H) | 330 × 300 × 150 mm |
| External Dimensions (L×W×H) | 360 × 330 × 280 mm |
| Drain Valve | Yes |
| Net Weight | 10.8 kg |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HN-180AL |
| Capacity | 58 L |
| Ultrasonic Frequency | 28 kHz or 40 kHz (selectable, single-frequency) |
| Ultrasonic Power | 1800 W |
| Power Adjustment | Continuously variable (0–100%) |
| Heating Temperature Range | 20–80 °C |
| Timer Range | 1–30 min |
| Lid with Sound-Dampening Design | Yes |
| Manual Fill/Drain | Yes |
| Internal Tank Dimensions | 550 × 350 × 300 mm (L×W×H) |
| External Dimensions | 650 × 400 × 580 mm (L×W×H) |
| Heating Power | 1500 W |
| Weight | 68 kg |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HN-19AL |
| Capacity | 19 L |
| Ultrasonic Frequency | 40 kHz |
| Ultrasonic Power | 400 W |
| Power Adjustment Range | 40–100% |
| Temperature Control Range | Ambient to 80 °C |
| Timer Range | 0–30 min |
| Lid with Sound-Dampening Design | Yes |
| Manual Drain/Refill | Yes |
| Instrument Type | General-Purpose Ultrasonic Cleaner |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HN-22AL |
| Capacity | 22 L |
| Ultrasonic Frequency | 40 kHz |
| Ultrasonic Power | 480 W |
| Power Adjustment | Yes (40–100% stepless) |
| Temperature Control | Yes (20–80 °C) |
| Timer | Yes (0–30 min) |
| Sound-Dampening Lid | Included |
| Drain Valve | Manual |
| Heating Power | 600 W |
| Internal Tank Dimensions | 500 × 300 × 150 mm |
| External Dimensions | 530 × 330 × 280 mm |
| Net Weight | 15.8 kg |
| Compliance | CE-marked for laboratory use per IEC 61010-1 |
| Brand | Hanuo |
|---|---|
| Origin | Shanghai, China |
| Model | HN-30AL |
| Tank Capacity | 30 L |
| Ultrasonic Frequency | 40 kHz |
| Ultrasonic Power Output | 600 W (adjustable 40–100%) |
| Heating Power | 800 W |
| Temperature Range | 20–80 °C (adjustable) |
| Timer Range | 0–30 min (adjustable) |
| Lid with Sound-Dampening Design | Yes |
| Manual Drain Valve | Yes |
| External Dimensions (W×D×H) | 570 × 335 × 320 mm |
| Internal Tank Dimensions (W×D×H) | 500 × 300 × 200 mm |
| Net Weight | 17.8 kg |
| Compliance | CE-marked design principles |
| Brand | Hanuo |
|---|---|
| Model | HN-3AL |
| Type | Benchtop General-Purpose Ultrasonic Cleaner |
| Capacity | 3 L |
| Ultrasonic Frequency | 40 kHz |
| Adjustable Ultrasonic Power | 40–100% (120 W nominal) |
| Adjustable Heating Power | 100 W |
| Temperature Range | 20–80 °C |
| Timer Range | 0–30 min |
| Tank Dimensions (L×W×H) | 240 × 135 × 100 mm |
| Overall Dimensions (L×W×H) | 270 × 170 × 240 mm |
| Net Weight | 3.5 kg |
| Drain Valve | Manual |
| Lid | Sound-Dampening Cover |
| Compliance | CE-marked design principles, compatible with ISO 13485-aligned lab workflows |