Common Laboratory Equipment
Filter
Showing 481–510 of 16567 results
| Origin | USA |
|---|---|
| Type | Box-Type Muffle Furnace |
| Maximum Temperature | 3000°C (5432°F) |
| Temperature Uniformity | ±3°C |
| Rated Power | 30 kW |
| Heating Rate to Max Temp | ≤60 min |
| Heating Method | Resistive Element (Mo/Ta/W/Graphite Options) |
| Internal Chamber Dimensions | 2.54 cm × 5.08 cm (standard) |
| Vacuum Capability | 10⁻⁵–10⁻⁶ Torr (with turbomolecular pump system) |
| Atmosphere Control | Vacuum, N₂, H₂ (wet/dry), Ar, forming gas |
| Compliance | NFPA 86 (2003 Edition) |
| Brand | Amerlab |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Model | AC XXXL |
| Automation Level | Fully Automatic |
| Cleanliness Level | ppt-level residue |
| Cycle Time | < 8 hours |
| Material Compatibility | PTFE/PFA-wetted path, PP chassis |
| Max Capacity | 252 digestion tubes per full cycle (3 × 84-tube channels) |
| Safety Interlocks | Temperature, pressure, liquid level, pH monitoring |
| Brand | Amerlab |
|---|---|
| Model | AC360 |
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Automation Level | Fully Automated |
| Cleanliness Level | ppt-level residue removal |
| Cycle Time | < 8 hours |
| Construction Materials | Full PTFE/PFA fluid path, PP chassis |
| Safety Features | Multi-point interlocks (temperature, pressure, liquid level, pH) |
| Regulatory Compliance | Designed for GLP/GMP environments |
| Brand | Amerlab |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | AC360 Manual |
| Price Range | USD 1,400 – 14,000 |
| Operation Mode | Semi-Automatic |
| Cleanliness Level | ppb–ppt |
| Cycle Time | 1–4 hours |
| Brand | Amerlab |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | AC360 Semi-Automatic |
| Price Range | USD 14,000–21,000 (FOB) |
| Operation Mode | Semi-Automatic |
| Cleanliness Level | ppt-level trace contamination removal |
| Cycle Time | 1–4 hours |
| Brand | Amerlab |
|---|---|
| Model | AC360M |
| Origin | Guangdong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Automation Level | Fully Automatic |
| Detection Limit | ppt-level cleanliness |
| Cycle Time | < 8 hours |
| Construction Materials | Full PTFE/PFA fluid path, PP chassis |
| Safety Interlocks | Temperature, pressure, liquid level, and pH monitoring |
| Brand | Amerlab |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | AC480 |
| Automation Level | Fully Automatic |
| Cleaning Sensitivity | ppt-level residue control |
| Cycle Time | 30 min acid vapor wash |
| Brand | Amerlab |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | AE100 |
| Instrument Type | Automated Quantitative Concentrator |
| Temperature Range | Ambient to 250 °C |
| Temperature Control Accuracy | ±1 °C |
| Maximum Sample Capacity per Vial | 100 mL |
| Brand | Amerlab |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | AP300 |
| Instrument Type | Fluoropolymer Distillation System |
| Heating Method | PTC Semiconductor Heating |
| Cooling Method | Integrated Closed-Loop Cooler (No External Chiller Required) |
| Distillation Rate | 70 mL/h (for 65% HNO₃) |
| Ramp Time | 60 min (25°C to 110°C) |
| Endpoint Control | Precision Photoelectric Liquid-Level Sensor |
| Heating Element | PTC Semiconductor Heater |
| Material Construction | PFA/PTFE-lined Chamber & Fluid Pathways |
| Safety Features | Dual Liquid-Level Monitoring (Feed/Pure Acid), Dry-Run & Overflow Prevention, Redundant Temperature Sensing, Onboard Acid Gas Neutralization System (99% Efficiency) |
| Dimensions | 38 × 35 × 60 cm (W × D × H) |
| Brand | Amerlab |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | AP300S |
| Instrument Type | Fluoropolymer (PTFE/PFA) Distillation Apparatus |
| Heating Method | PTC Semiconductor Heating |
| Cooling Method | Integrated Air-Cooled Condenser (No External Chiller Required) |
| Distillation Rate | 70 mL/h (for 65% HNO₃) |
| Ramp Time | 60 min (from 25°C to 110°C) |
| Endpoint Control | Precision Photoelectric Liquid-Level Sensor |
| Dual Independent Pump System | Acid Feed + Waste Drain |
| Safety Interlocks | Real-Time Level Monitoring (Crude Acid Low/High, Pure Acid Overflow), RTC Immersion Temperature Sensing, Self-Limiting PTC Thermal Regulation |
| Acid Vapor Recovery Efficiency | >99% (Integrated Neutralization & Adsorption) |
| Dimensions | 38 × 35 × 60 cm (W × D × H) |
| Material Contact Path | PTFE, PFA, and Quartz Only |
| Brand | Amerlab |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | AP400 |
| Instrument Type | Fluoropolymer Distillation System |
| Heating Method | PTC Semiconductor Heating |
| Cooling Method | Integrated Closed-Circuit Cooler (No External Chiller Required) |
| Distillation Rate | 45 mL/h |
| Ramp Time | 60 min (Room Temperature to 110 °C) |
| Endpoint Control | Precision Photoelectric Liquid-Level Sensor |
| Heating Element | PTC Semiconductor Heater |
| Compliance | Designed for ISO/IEC 17025-compliant laboratories |
| Brand | Advanced MicroFluidics (Switzerland) |
|---|---|
| Origin | Switzerland |
| Model | LSPone |
| Instrument Type | Precision Microfluidic Syringe Pump |
| Flow Rate Range | 0.25 nL/min to 30 mL/min |
| Flow Stability | Near-pulseless operation with high repeatability |
| Valve Dead Volume | As low as 1.5 µL |
| Operating Temperature | 5–40 °C |
| Operating Humidity | 20–80% RH (non-condensing) |
| Max System Pressure | 5 bar |
| Pump Drive | Linear encoder-equipped stepper motor with stall detection |
| Resolution | 3000 steps (standard) / 24,000 steps (high-res option) |
| Communication Interfaces | USB Mini-B, RS232, RS485, I²C (customizable) |
| Power Supply | 18–24 VDC, ≤2.2 A |
| Dimensions | 245 × 143 × 85 mm |
| Weight | 2.2 kg |
| Compliance | CE, CB |
| Software Support | Windows 7+, macOS, SDK for C/C++, Python, MATLAB, LabVIEW |
| Brand | AMF / Advanced MicroFluidics |
|---|---|
| Origin | Switzerland |
| Model | RVM |
| Operating Voltage (Low-Pressure Version) | USB-powered (5 V DC) |
| Operating Voltage (High-Pressure Version) | 24 V DC |
| Internal Volume | As low as 3.5 µL |
| Valve Head Interchangeability | Yes — single actuator body supports multiple replaceable valve heads (e.g., 1-to-N, on/off, 2-position 6-way) |
| Dead Volume | Negligible (designed for bubble-free fluid path switching) |
| Brand | Advanced MicroFluidics (AMF) |
|---|---|
| Origin | Switzerland |
| Model | SPM OEM Syringe Pump |
| Instrument Type | Precision Microfluidic Syringe Pump |
| Flow Rate Range | 0.25 nL/min to 30 mL/min (model-dependent) |
| Accuracy | <1% deviation over full stroke |
| Repeatability | High-precision volumetric delivery |
| Dead Volume | <1.5 µL (valve-integrated configurations) |
| Operating Temperature | 5–40 °C |
| Operating Humidity | 20–80% RH, non-condensing |
| Max Back Pressure | 5 bar (pump head) |
| Drive Mechanism | Linear encoder-equipped lead screw actuator |
| Resolution | 3000 steps (standard) / 24,000 steps (high-res option) |
| Communication Interfaces | USB Mini-B, RS232, RS485, I²C (customizable) |
| Power Supply | 18–24 VDC, max 2.2 A |
| Dimensions | 199.7 × 126.3 × 50.5 mm |
| Weight | 1.5 kg |
| Brand | AML |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AWB-04 |
| Pricing | Upon Request |
| Key | Brand: Amptek |
|---|---|
| Origin | USA |
| Model | Mini-X2 |
| Max Power | 4 W or 10 W |
| Max HV | 50 kV or 70 kV |
| Anode Materials | Ag, Rh, Au, W |
| Tube Voltage Range | 10–50 kV or 35–70 kV |
| Tube Current Range | 5–200 µA |
| Anode Thickness | Ag/Rh = 0.75 µm (±0.1 µm), Au/W = 1.00 µm (±0.1 µm) |
| Window Material | Be (127 µm) |
| Focus Size | ~2 mm |
| HV Polarity | Grounded Anode |
| HV Stability | <0.1% |
| Output Flux Stability | <0.3% (temperature-stabilized) |
| Beam Divergence | 120° |
| Cooling | Air-cooled |
| Leakage Radiation | <5 µSv/h at 5 cm with safety plug |
| Operating Temp | −10°C to +50°C |
| Storage Temp | −25°C to +60°C |
| Humidity | 30–90% RH (non-condensing) |
| Interface | USB 2.0 (mini-USB), 12 VDC input, AUX I/O with interlock & status indicators |
| Control Software | Mini-X Control GUI + Mini-X API (C/C++, Python, LabVIEW) |
| Warranty | 1 year or 2000 operating hours, whichever occurs first |
| Brand | SHNTI |
|---|---|
| Origin | Shanghai, China |
| Model | AMT |
| Type | Desktop Active Vibration Isolation System |
| Control Architecture | Digital Adaptive Feedback + Bottom-Mounted Feedforward |
| Sensor Configuration | Triaxial Floor-Mounted + Platform-Mounted Accelerometers |
| Stability | Robust Control Algorithm with Long-Term Drift Compensation |
| Compliance | Designed for ISO 20483 Class 1–2 Laboratory Environments |
| Load Capacity | Up to 50 kg (typical for mid-size AFM, optical interferometers, nanoindenter systems) |
| Interface | Ethernet/USB, Web-Based GUI with Real-Time Monitoring |
| Brand | AMTK |
|---|---|
| Model | HL1406 |
| Origin | Beijing, China |
| Plate Capacity | 12 positions |
| Pipetting Range | 0.3 µL – 5 mL |
| Pipetting Precision | CV < 10% at volumes < 1 µL |
| Sample Throughput Options | 1 / 8 / 16 / 32 samples per run |
| Dimensions (W×D×H) | 50 × 60 × 70 cm |
| Operating Temperature | 23 °C ± 5 °C |
| Power Supply | 110/220 VAC, 50/60 Hz |
| Relative Humidity | 10–90% RH (non-condensing) |
| Brand | AMTK |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LH-1510+ |
| Deck Positions | 3 |
| Pipetting Precision | CV < 5% at 1 µL |
| Pipetting Range | 0.5–1000 µL |
| Throughput | 96-well format (single-tip or multichannel mode) |
| Dimensions | 47 × 27 × 60 cm |
| Weight | 60 kg |
| Power Supply | AC 220 V, 50 Hz, 350 VA |
| Compatible Tip Volumes | 70 µL, 250 µL, and 1000 µL 96-channel disposable tip arrays |
| Actuation Principle | Air-displacement positive displacement pump |
| Tip Compatibility | Proprietary sterilized, low-retention, QC-validated polypropylene tips |
| Brand | AMTK |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LH1209 |
| Price Range | USD 70,000–112,000 (FOB) |
| Deck Capacity | 25 positions |
| Pipetting Precision | CV < 5% (for volumes ≥ 1 µL) |
| Pipetting Range | 0.3–200 µL |
| Sample Throughput | 96-well format per run |
| Dimensions (W×D×H) | 1100 mm × 750 mm × 900 mm |
| Compatible Tips | 10 µL, 30 µL, 70 µL, 250 µL |
| Operating Temperature | 23 °C ± 5 °C |
| Power Supply | 220 VAC, 50 Hz |
| Relative Humidity | 10–90% RH (non-condensing) |
| Brand | AMTK |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LH-1406 |
| Plate Positions | 12 |
| Pipetting Precision | CV < 5% (for volumes > 1 µL) |
| Pipetting Range | 1 µL – 5 mL |
| Sample Throughput Options | 1 / 8 / 16 / 32 samples per run |
| Dimensions | 60 cm × 50 cm × 70 cm |
| Operating Environment | 10–30 °C |
| Power Supply | AC 220 V, 50 Hz |
| Compatible Tips | 10 µL, 30 µL, 70 µL, 250 µL, 1 mL, 5 mL |
| Available Heads | ST (Standard Tip), LT (Low-Volume Tip), XT (Extended-Range Tip), Gripper Module |
| Brand | AMTK |
|---|---|
| Origin | Beijing, China |
| Model | LH1808 |
| Deck Capacity | 30 + 10 (expandable) |
| Pipetting Accuracy | CV < 5% at 2 µL |
| Pipetting Range | 0.5–1000 µL |
| Sample Throughput | 384 samples |
| Dimensions (Main Deck) | 110 × 80 × 90 cm (L×D×H) |
| Dimensions (Rotary Carousel) | 60 × 80 × 70 cm (L×D×H) |
| Power Supply | AC 220 V, 50 Hz, 450 W |
| Weight | 150 kg |
| Compatible Tips | 10 µL, 30 µL, 50 µL, 250 µL, 1 mL |
| SBS-Compliant Vessels | 24-, 96-, and 384-well plates, centrifuge tubes, collection tubes |
| Barcode Scan Time per Tube | < 2.3 s |
| Liquid Level Detection Error | ±0.5 mm |
| Pipetting Accuracy & Precision | 250 µL tip: ±8.0% accuracy / ≤4.0% CV at 10 µL |
| 1000 µL tip | ±2.0% / ≤1.0% at 100 µL |
| Brand | AMTK |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | S-L |
| Plate Positions | 3 |
| Pipetting Accuracy | <5% CV at ≥2 µL |
| Pipetting Range | 0.5 µL – 1 mL |
| Sample Throughput | 96–192 samples per run |
| Dimensions (W×D×H) | 47 × 37 × 60 cm |
| Pipetting Precision | CV <10% at <1 µL |
| Compatible Tips | 10 µL, 30 µL, 70 µL, 250 µL, 1 mL |
| Operating Environment | 23 °C ±5 °C, Relative Humidity 10–90% non-condensing |
| Power Supply | 85–240 VAC, 50/60 Hz |
| Brand | Analab |
|---|---|
| Origin | France |
| Device Type | Sub-boiling Distiller |
| Capacity | 12 × 125 mL |
| Construction | PFA-coated (400 µm thickness) |
| Compliance | ISO Class 1 Cleanroom Certified |
| Heating Uniformity | ±0.5 °C across surface |
| Operating Principle | Controlled sub-boiling evaporation with condensate isolation |
| Brand | Analysis |
|---|---|
| Origin | Spain |
| Manufacturer | Ortoalresa S.L. |
| Model | BIOCEN 22R |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | 200–18,100 rpm |
| Max RCF | 31,865 × g |
| Max Capacity | 8 × 15 mL |
| Temperature Range | –20 °C to +40 °C (1 °C increments) |
| Refrigerant | R-449A (HFO-based, non-CFC) |
| Dimensions (W×D×H) | 276 × 640 × 272 mm |
| Noise Level | <65 dB(A) |
| Compliance | EN 61010-1, EN 61010-2-101, EN 61010-2-020, EN 61326-1, EN 61326-2-6 |
| Safety Certifications | 2011/65/EU (RoHS), 2012/19/EU (WEEE), 2014/30/EU (EMC), 2014/35/EU (LVD), 98/79/EC (IVDR), (EC) No 1005/2009, (EU) No 517/2014 |
| Brand | Analysis |
|---|---|
| Origin | Spain |
| Manufacturer Type | Manufacturer |
| Product Category | Imported |
| Model | Bioprocen 22 R |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | High-Speed (10,000–30,000 rpm) |
| Function | Refrigerated Centrifuge |
| Configuration | Fixed-Angle Rotor Centrifuge |
| Max Capacity | 6 × 50 mL |
| Max Speed | 18,100 rpm |
| Max RCF | 31,865 × g |
| Dimensions (W×D×H) | 410 × 690 × 320 mm |
| Brand | Analysis |
|---|---|
| Origin | Spain |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | CONSUL22 |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | 100–14,300 rpm |
| Maximum RCF | 21,948 × g |
| Maximum Capacity | 4 × 400 mL |
| Dimensions (W×D×H) | 490 × 600 × 400 mm |
| Noise Level | <60 dB(A) |
| Power Supply | 220–230 V / 50–60 Hz or 110–120 V / 50–60 Hz |
| Power Consumption | 620 W |
| Rotor Recognition | Automatic |
| Safety Compliance | EN 61010-1, EN 61010-2-101, EN 61010-2-020, EN 61326-1, EN 61326-2-6 |
| Regulatory Directives | 2011/65/EU (RoHS), 2012/19/EU (WEEE), 2014/30/EU (EMC), 2014/35/EU (LVD), 98/79/EC (IVDD) |
| Brand | Analysis |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | HCV2000 |
| Instrument Category | Other Vacuum Pumps |
| Product Type | Oil-Free Vacuum Pump |
| Pumping Speed | 200 L/min |
| Ultimate Vacuum | –92 kPa |
| External Dimensions | 244 × 128 × 205 mm (L × W × H) |
| Weight | 9 kg |
| Motor Power | 500 W |
| Rated Voltage/Frequency | 220 V / 50 Hz (customizable) |
| Insulation Class | B |
| Thermal Protector | Auto-resetting at 130 ± 5 °C |
| Operating Ambient Temperature | 5–40 °C |
| Inlet/Outlet Port Thread | G1/4″ NPT |
| Hose Connection Diameter | 6 mm × 4 mm |
| Brand | Analysis |
|---|---|
| Origin | Beijing, China |
| Model | HCV300 |
| Pump Type | Oil-Free Diaphragm Vacuum Pump |
| Ultimate Vacuum | -86 kPa |
| Pumping Speed | 55 L/min |
| Motor Power | 200 W |
| Dimensions (L×W×H) | 170 × 124 × 134 mm |
| Weight | 3.5 kg |
| Operating Temperature Range | 5–40 °C |
| Insulation Class | B |
| Thermal Protector | Auto-reset at 130 ± 5 °C |
| Inlet/Outlet Port | G1/4" NPT |
| Tubing Connection | 6 mm × 4 mm (ID × OD) |
| Voltage/Frequency | 220 V / 50 Hz (customizable) |
| Brand | Analysis |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HCV400 |
| Instrument Category | Other Vacuum Pumps |
| Product Type | Oil-Free Diaphragm Vacuum Pump |
| Pumping Speed | 20 L/min |
| Ultimate Vacuum Pressure | ≤ 200 mbar (≤ −0.08 MPa gauge) |
| External Dimensions | 215 × 120 × 235 mm |
| Weight | 7.5 kg |
| Motor Power | 160 W |
| Inlet/Outlet Port Diameter | Ø6 mm |
| Operating Ambient Temperature | 7–40 °C |
| Pump Body Operating Temperature | < 55 °C |
| Noise Level | < 50 dB(A) |
