| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | MK2000-2E |
| Temperature Range | Ambient +5°C to 100°C |
| Temperature Stability @100°C | ≤0.5°C |
| Block Uniformity @37°C | ±0.2°C |
| Heating Time (25°C to 105°C) | ≤20 min |
| Display Resolution | 0.1°C |
| Dimensions (W×D×H) | 365 mm × 210 mm × 150 mm |
| Net Weight | 4.5 kg |
| Power Supply | AC 220 V / 120 V, 50 / 60 Hz |
| Rated Power | 200 W |
| Dual Independent Heating Zones | Yes |
| Standard Module Quantity | 2 |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | MK2000-2HL Dry Bath Incubator with Heat Lid |
| Temperature Range | Ambient +5°C to 105°C |
| Temperature Stability @100°C | ≤0.5°C |
| Block Uniformity @37°C (within block) | ±0.2°C |
| Block-to-Block Uniformity @37°C | ±0.3°C |
| Heating Time (25°C → 105°C) | ≤20 min |
| Display Resolution | 0.1°C |
| Timer Range | 0–99 h 59 min |
| Power Supply | AC 220V / 120V, 50/60 Hz |
| Rated Power | 200 W |
| Dimensions (W×D×H) | 420 mm × 225 mm × 145 mm |
| Net Weight | 5.5 kg |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | MPC-P25 |
| Instrument Type | Benchtop Centrifuge |
| Category | Low-Speed Centrifuge (≤2,200 rpm) |
| Rotor Configuration | Horizontal Swinging-Bucket Rotor |
| Max Capacity | 2 × microplates (96-well or 384-well PCR/ELISA plates), 24 × 0.2 mL PCR strips, or 192 × 0.2 mL PCR tubes |
| Max Speed | 2,200 rpm |
| Max RCF | 480 × g |
| Timer Range | 0–10 min |
| Dimensions (W×D×H) | 290 × 360 × 140 mm |
| Weight | 3.6 kg |
| Power Supply | AC 120 V / 220 V, 50 / 60 Hz |
| Safety Features | Automatic braking (brake time ≈ 30 s), transparent lid with interlock, soft-start/soft-stop control |
| Brand | Allsheng |
|---|---|
| Model | MTV-100 |
| Orbital Diameter | 3.6 mm |
| Speed Range | 500–2500 rpm |
| Speed Accuracy | ±10 rpm |
| Timer Range | 1 min – 99 h 59 min |
| Max Load Capacity | 4.5 kg |
| Top Panel Dimensions (L×W) | 310 × 180 mm |
| Instrument Dimensions (L×W×H) | 426 × 250 × 480 mm |
| Net Weight | 21.5 kg |
| Power Consumption | 60 W |
| Safety Certification | CE-compliant |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | TD2-24 |
| Quotation | Upon Request |
| Speed Range | 500–1500 rpm |
| RCF Range | 33–294 × g |
| Capacity | 24 columns (6- or 8-column immunohematology cards) |
| Timer Range | 1–20 min |
| Noise Level | ≤55 dB(A) |
| Power Supply | AC 100–240 V, 50/60 Hz, 3 A |
| Power Consumption | 85 W |
| Dimensions (L×W×H) | 530 × 410 × 180 mm |
| Weight | 11.5 kg |
| Brand | ALP |
|---|---|
| Origin | Japan |
| Model | CL-32L / CL-40M |
| Chamber Volume | 54 L (CL-32L), 85 L (CL-40M) |
| Max Operating Temperature | 140 °C (CL-32L), 137 °C (CL-40M) |
| Max Working Pressure | 0.27 MPa (CL-32L), 0.25 MPa (CL-40M) |
| Sterilization Temp Range | 40–140 °C (CL-32L), 40–137 °C (CL-40M) |
| Melting/Insulation Range | 40–99 °C / 40–60 °C |
| Cycle Time | Sterilization/Melting: 0–600 min or continuous |
| Insulation | 0–2880 min |
| Drying Temp Range | 60–180 °C |
| Drying Timer | 0–5940 min or continuous |
| Control System | Microprocessor-based with graphical LCD interface |
| Safety Compliance | ASME BPVC Section VIII Div. 1, PED 2014/68/EU, ISO 17665-1, GB/T 30690–2014, China Special Equipment Manufacturing License (Pressure Vessel) |
| Brand | ALP |
|---|---|
| Origin | Japan |
| Model | CLG-32L / CLG-40M |
| Chamber Dimensions (Ø × Depth) | 320 × 676 mm (32L) / 400 × 672 mm (40M) |
| Chamber Volume | 54 L / 85 L |
| Sterilization Temp Range | 100–140 °C (CLG-32L), 100–137 °C (CLG-40M) |
| Dissolution/Heating Temp Range | 40–99 °C / 40–60 °C |
| Max Operating Pressure | 0.270 MPa / 0.250 MPa |
| Cycle Time | Sterilization/Dissolution: 0–10 h |
| Holding | 0–48 h |
| Programmable Cycles | 10 stored protocols with mode & data logging |
| Vacuum System | Triple-pulse pre-vacuum with high-capacity vacuum pump |
| Air Filtration | 0.2 µm hydrophobic filter for heated air drying |
| Drying Method | Vacuum-assisted hot-air drying post-sterilization |
| Safety Certification | PED 97/23/EC compliant |
| Construction | Inner chamber – SUS304 stainless steel |
| Power Supply | AC 220–240 V, 1-phase, 50/60 Hz |
| Rated Current | 12 A |
| Heating Power | 2.6 / 2.8 / 2.9 kW (model-dependent) |
| Dimensions (W×D×H) | 550 × 550 × 950 mm (CLG-32L) / 620 × 650 × 990 mm (CLG-40M) |
| Weight | 65 kg / 83 kg |
| Control Interface | Backlit LCD display with real-time monitoring of temperature, pressure, phase status, and elapsed time |
| Door Mechanism | Central lever lock with automatic interlock, motor-assisted hinge, and power-dependent electronic safety lock |
| Cooling | Active rapid cooling to <80 °C post-cycle |
| Drainage | Front-mounted manual drain valve and accessible front-positioned waste tank |
| Optional | Integrated product temperature probe port (probe sold separately) |
| Compliance | Meets IEC 61000-6-3 (EMC) and IEC 61000-6-4 (emission) standards |
| Brand | Alpao |
|---|---|
| Origin | France |
| Type | OEM Deformable Mirror |
| Diameter | 50 mm |
| Max. Piston Stroke | 100 µm (P-V) |
| Fitting Error | ≤2% RMS |
| Actuation Principle | Electromagnetic |
| Control Mode | Zernike Mode-Based Open-Loop or Closed-Loop |
| Compatibility | Windows/Linux/macOS, C/C++/Python/MATLAB APIs |
| Power Supply | Low-Voltage DC (<24 V), Low Power Consumption |
| Sensor Integration | Compatible with Shack-Hartmann and Pyramid Wavefront Sensors |
| Brand | Alpha Plasma |
|---|---|
| Origin | Germany |
| Model | Q150 |
| Instrument Type | Imported Microwave Plasma Surface Treater |
| Category | Plasma-Based Sample Preparation Equipment |
| Distribution Status | Authorized Distributor (Non-Manufacturer) |
| Import Classification | Imported Equipment |
| Pricing | Available Upon Request |
| Brand | Alpha |
|---|---|
| Origin | Germany |
| Model | Q-Series |
| Frequency | 2.45 GHz |
| Power Range | 50–1200 W (model-dependent) |
| Chamber Material | Quartz or Borosilicate Glass |
| Max Wafer Size | 8-inch |
| Working Pressure | ≤100 Pa |
| Vacuum System | Integrated dry pump (oil pump optional) |
| Gas Control | Up to 6 MFC channels (2–3 standard) |
| Vacuum Gauges | Pirani (1–1×10⁵ Pa) and/or Baratron (1–1000 Pa) |
| Control Interface | 7"–10.4" TFT touchscreen |
| Operating System | Windows Embedded Compact 2013 |
| Compliance | CE, RoHS, SEMI S2/S8 compatible |
| Dimensions (W×H×D) | 500×370×550 mm to 760×775×775 mm |
| Weight | 40–95 kg |
| Utilities | 3/N/PE AC 240/400 V, 50/60 Hz, 16 A |
| Brand | Alphavita |
|---|---|
| Model | MCC-800 |
| Origin | Liaoning, China |
| Construction | Galvanized steel with epoxy-polyester coating |
| Interior Shelving | Polypropylene (PP) |
| External Dimensions (W×D×H) | 800 × 525 × 1960–2362 mm |
| Internal Dimensions (W×D×H) | ≥796 × 470 × 1752 mm |
| Airflow Rate | 240 m³/h |
| Air Changes per Hour | ≥410 ACH |
| Shelf Load Capacity | ≥180 kg per shelf |
| Filtration Media | Dual standard activated carbon molecular filters (PP housing) |
| Adsorption Capacity | IPA ≥500 g, Cyclohexane ≥750 g, HCl ≥1620 g |
| TVOC Sensor Resolution | 0.1 ppm |
| Display | 3.5-inch LED smart interface |
| Compliance | JG/T 385–2012 |
| Third-Party Liability Insurance | ≥¥5 million RMB |
| Brand | Alphavita |
|---|---|
| Model | MVC-1300 |
| Type | Ductless (Recirculating) Fume Hood |
| Construction | Fully Steel Cabinet with Epoxy-Polyester Coated Galvanized Steel |
| Filter System | Modular Dual-Layer Molecular Filtration (4 Standard PP-Housed Filters) |
| Face Velocity Range | 0.4–0.6 m/s |
| Airflow Volume | 480 m³/h |
| External Dimensions (W×D×H) | 1300 × 790 × 920–1502 mm |
| Internal Dimensions (W×D×H) | ≥1286 × 690 × 760 mm |
| Filter Capacity | IPA ≥500 g, Cyclohexane ≥750 g, HCl ≥1620 g |
| TVOC Detection Resolution | 0.1 ppm |
| Face Velocity Sensing Accuracy | ±0.1 m/s |
| Display | 3.5-inch LED Smart Panel (real-time temp, fan speed, face velocity, filter life countdown, inlet/outlet TVOC) |
| Connectivity | Optional Wi-Fi/4G-enabled EMonitor App (remote monitoring, alarm push notifications, parameter adjustment) |
| Compliance | JG/T 385–2012, GBZ/T 160.55, third-party public liability insurance ≥¥5 million RMB |
| Waste Filter Handling | Certified industrial hazardous waste disposal provider engagement documented |
| Brand | Alphavita |
|---|---|
| Origin | Liaoning, China |
| Model | MVS-3780 |
| Chamber Dimensions (Ø × H) | 370 mm × 795 mm |
| Chamber Volume | 83 L |
| External Dimensions (W × D × H) | 550 × 550 × 1050 mm |
| Net Weight | 83 kg |
| Power Rating | 3100 W |
| Electrical Interface | 16 A plug |
| Safety Compliance | Dual dry-run protection, overcurrent & leakage protection, pressure relief valve, four-point interlock system, chamber overpressure alarm, 98% air removal efficiency |
| Brand | Alphavita |
|---|---|
| Origin | Liaoning, China |
| Model | MVS-60 |
| Sterilization Chamber Dimensions | Φ370 × 610 mm |
| External Dimensions | 550 × 550 × 820 mm |
| Chamber Volume | 55 L |
| Vessel Material | S30408 stainless steel (GB/T 24511–2017), 3 mm wall thickness |
| Design Standard | GB 150–2011 |
| Altitude Rating | Certified for operation up to 4000 m ASL |
| Safety Features | Dual dry-run protection, overcurrent protection, earth-leakage detection, four-point interlocked door system, spring-loaded safety valve, real-time overpressure alarm |
| Exhaust System | Pressure-stabilized air removal (98% air displacement), six-stage adjustable exhaust rate & temperature |
| Cooling | High-capacity external cooling fan (optional internal fan), variable-speed cooling control |
| Control Modes | Four pre-programmed cycles + user-defined program memory + pre-heating cycle + time-scheduled start |
| Brand | Alphavita |
|---|---|
| Origin | Liaoning, China |
| Model | MVS-83 |
| Instrument Type | Vertical Autoclave |
| Max Temperature | 135 °C |
| Max Pressure | 0.3 MPa |
| Chamber Dimensions (W×H) | 370 mm × 795 mm |
| External Dimensions (W×D×H) | 600 mm × 620 mm × 1005 mm |
| Chamber Volume | 83 L (≥75 L effective) |
| Power Rating | 4200 W |
| Net Weight | 90 kg |
| Safety Class | Class I Pressure Vessel |
| Manufacturing License | DI-Class |
| Temperature Sensor | PT100 |
| Pressure Gauge Range | −0.1 to 0.5 MPa |
| Safety Valve Set Point | 0.28 MPa |
| Cooling System | Dual-Cooling (axial + shaded-pole fans + condenser) |
| Exhaust | Adjustable 5-level downward exhaust |
| Operating Altitude Range | 0–3000 m |
| Timer Range | 0–4320 min (1 min resolution) |
| Brand | Alphavita |
|---|---|
| Model | MVS-84 |
| Chamber Volume | 83 L |
| External Dimensions (W×D×H) | 600 × 620 × 1005 mm |
| Internal Dimensions (Ø × H) | Ø370 × 795 mm |
| Net Weight | 100 kg |
| Power Rating | 3100 W |
| Construction Material | S30408-2B stainless steel (3 mm thickness) |
| Compliance | YY/T 1007–2018, GB 150, GB/T 24511–2017 |
| Safety Features | Dual dry-run protection, overcurrent protection, earth leakage protection, quadruple mechanical/electrical interlock, spring-loaded safety valve, chamber overpressure alarm |
| Operating Altitude | Up to 4000 m ASL |
| Power Interface | 16 A standard plug |
| Brand | Alphavita |
|---|---|
| Model | SIM-F140BDL |
| Ice Type | Flake Ice |
| Ice Production Capacity | 130 kg/24h (at 20°C ambient, 15°C water) |
| Storage Capacity | 28 kg (19 kg free-fall output) |
| Water Consumption | 0.16 m³/24h (20°C ambient, 15°C water) |
| Cooling Method | Hermetic Compressor with HFC Refrigerant |
| Power Input | 435 W |
| Net Weight | 72 kg |
| External Dimensions (W×D×H) | 600 × 600 × 800 mm |
| Operating Ambient Temperature | 5–35°C |
| Maximum Inlet Water Temperature | ≤35°C |
| Water Inlet Port | 1/2″ BSP |
| Drain Ports | Ice Maker Drain – 3/4″ BSP |
| Cabinet Materials | Front/Sides – Coated Stainless Steel |
| Inner Bin Material | ABS Resin |
| Brand | Alphavita |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SIM-F140LBSY |
| Ice Storage Capacity | 46 kg |
| Ice Production Rate | 130 kg/day (at 20°C ambient, 15°C water) / 110 kg/day (at 30°C ambient, 25°C water) |
| Water Consumption | 0.16 m³/day (20°C/15°C) / 0.14 m³/day (30°C/25°C) |
| Power Consumption | 435 W |
| Net Weight | 81 kg |
| External Dimensions (W×D×H) | 900 × 600 × 800 mm |
| Motor Life Expectancy | 18,000 hours |
| Ice Output Temperature | ≈ −5°C |
| Material | Antimicrobial Stainless Steel (contact surfaces), Mold-Inhibited Door Gasket |
| Optional Accessory | Flexible Drain Hose |
| Compliance | Designed for GLP-compliant laboratory environments |
| Brand | Altamira Instruments (USA) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | BenchCAT Custom Catalyst Evaluation System |
| Reaction Pressure | 300 bar |
| Reaction Temperature | 1200 °C |
| Catalyst Loading Capacity | mL- to L-scale configurable |
| Brand | Zhongke Aobo |
|---|---|
| Origin | Beijing, China |
| Model | Φ12–300 mm |
| Material Composition | ≥99% Al₂O₃, ≤0.2% R₂O, ≤0.1% Fe₂O₃, ≤0.2% SiO₂ |
| Bulk Density | ≥3.80 g/cm³ |
| Apparent Porosity | <1% |
| Flexural Strength | >350 MPa |
| Compressive Strength | >12,000 MPa |
| Dielectric Constant (1 MHz) | ~9.8 |
| Hardness (HRA) | 88 |
| Max. Input Particle Size | 20 mm |
| Min. Output Particle Size | 0.5 mm |
| Batch Capacity | 100 mL |
| Sample Type | Hard, brittle, non-ferrous, high-purity materials |
| Compliance | Suitable for ISO/IEC 17025-accredited labs requiring inert, non-contaminating sample preparation |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SHT Series Aluminum Block |
| Price | Available Upon Request |
| Brand | AM Systems |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | YUYANBIO |
| Type | AC/DC Differential Amplifier |
| Input Impedance | 10¹¹–10¹⁵ Ω |
| Gain Range | 2–20,000 (Model 3500), 50–10,000 (Model 3000), 100–10,000 (Models 1800 & 1700) |
| Noise | 0.1 fA/√Hz (current noise), 1.0–1.8 µV p-p (10 Hz–10 kHz) |
| Capacitance Compensation | 4–50 pF |
| Filter Options | Adjustable high-pass (0.3 Hz–500 Hz), low-pass (100 Hz–20 kHz), 50/60 Hz notch |
| DC Offset Compensation | ±250 mV |
| Output Range | ±8 V |
| Enclosure | 3U rackmount (Model 3500, 16-channel compatible) |
| Software Control | USB-based Windows GUI with MATLAB® and LabVIEW® SDKs |
| Compliance | GLP/GMP-ready architecture with audit-trail-capable parameter logging |
| Brand | AM Technology |
|---|---|
| Origin | United Kingdom |
| Model | ACR-P200 |
| Reactor Type | Continuous Multistage Agitated Flow Reactor |
| Number of Stages | 10 |
| Total Reaction Volume | 100 mL (10 × 10 mL per stage) |
| Flow Rate Range | 8–80 mL/min |
| Residence Time Range | 30 s to several hours |
| Temperature Range | −40 °C to +140 °C |
| Operating Pressure | 0–10 bar |
| Wetted Materials | Hastelloy, PTFE, FFKM, Ceramic |
| Agitation Mechanism | Lateral oscillation-driven magnetic stir-bar motion |
| Heat Exchange | Integrated stage-matched thermal plates with independent coolant channels |
| Control Interface | Digital PID control, real-time data logging, remote Ethernet/OPC UA connectivity |
| Compliance | Designed for GLP-compliant process development environments |
| Brand | AMAE |
|---|---|
| Origin | Guangdong, China |
| Model | AM-1200 |
| Type | Integrated Acid Digestion & Vacuum Filtration Workstation for ASTM D7687 / GBZ/T 192.4–2018 Compliant Free Silica Analysis |
| Brand | AMAE |
|---|---|
| Origin | Guangdong, China |
| Model | AM-1200 Series |
| Type | Fully Automated Sample Preparation Workstation for Free Silica Determination (Pyrophosphoric Acid Method) |
| Sample Throughput | Up to 5 samples simultaneously (10-sample unattended sequence) |
| Temperature Control | Full-process constant-temperature heating (acid digestion & deionized water rinse) |
| Liquid Transfer Method | Vacuum-assisted non-contact transfer |
| Residual Volume | <0.5% |
| Data Logging | Real-time parameter recording with timestamped audit trail |
| Compliance Support | Designed to meet requirements of GBZ/T 192.4–2018, ISO 13797:2021 (Determination of respirable crystalline silica), and GLP-aligned documentation practices |
| User Interface | 7-inch high-resolution color touchscreen |
| Safety Features | Interlocked access door, integrated silent fume extraction (ductable to lab hood), active cooling, auto-drying function |
| Expandability | Modular architecture supports future integration of alternative digestion modules |
| Firmware Update | USB flash drive–based update protocol |
| Consumables | Standardized 50 mL high-purity quartz or ceramic crucibles (900 °C rated) |
| Brand | AMAE |
|---|---|
| Origin | Guangdong, China |
| Model | AM-1210 |
| Display | 7-inch high-resolution color touchscreen |
| Sample throughput | 5 parallel channels |
| Temperature control accuracy | ±1 °C (resolution: 0.1 °C) |
| Integrated process | automated digestion, liquid transfer, dilution, acid/water washing, vacuum filtration |
| Compliance | designed for ASTM D7521 (determination of free silica by pyrophosphoric acid method), ISO 13791, and OSHA Method ID-142 |
| Software audit trail | GLP-compliant event logging with timestamped operator actions |
| Power supply | 220 V AC, 50/60 Hz |
| Brand | AMAE |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | AM-1860 |
| Pricing | Upon Request |
| Dispensing Range | 0.5–10.0 mL |
| Dispensing Resolution | 0.1 mL |
| Display | High-Resolution Rotating Touchscreen |
| Dispensing Channels | 3 Independent Programmable Channels |
| Bottle Compatibility | Interchangeable Sample Vial Adapters (250 mL, 500 mL, 1 L) |
| pH-Based Dosage Logic | Embedded Algorithm per HJ 494–2009 & GB/T 5750.2–2023 |
| Calibration Mode | User-Adjustable Compensation Function |
| Enclosure Protection | Shock-Absorbing Housing with Illuminated Viewing Window & Leak-Resistant Reservoir Bay |
| Brand | Ambrell |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Industrial Induction Heating Systems |
| Model Series | EKOHEAT® 10/100 to EKOHEAT® 270/100 |
| Frequency Range | 50–150 kHz |
| Input Voltage | 360–520 V AC, 3-phase |
| Power Output Range | 10 kW to 270 kW |
| Input Apparent Power | 12 kVA to 300 kVA |
| Core Architecture | Variable Power Architecture (VPA) |
| Control Software | eVIEW® with real-time temperature monitoring and data logging |
| Compliance | Designed for industrial environments compliant with UL 508A, CE, and RoHS |
| Brand | ARS |
|---|---|
| Origin | USA |
| Model | X-3 |
| Cooling Capacity Options | 4 K (0.1 W @ 4.2 K), 5.5 K (1 W @ 10 K), or 10 K |
| Cold Head Compatibility | DE-202, DE-204, DE-210 series |
| Construction Material | Aluminum (standard), Stainless Steel (customizable) |
| Vacuum Enclosure | Aluminum or stainless steel DMX-3 vacuum shroud optimized for electrical transport measurements |
| Radiation Shield | Aluminum thermal radiation shield |
| Temperature Sensing | ±0.5 K calibrated silicon diode (control), ±12 mK calibrated silicon diode with 4-ft lead (sample-stage metrology) |
| Electrical Interface | 10-pin hermetic feedthrough, four dedicated low-noise measurement leads, electrically isolated sample stage |
| Optional Upgrades | 450 K / 800 K high-temperature insert, custom thermometer mounting, custom wiring harness, custom sample holder geometry |
| Brand | ARS |
|---|---|
| Origin | USA |
| Model | LT3B-OM |
| Operating Temperature Range | 1.7 K (pumped He) to 300 K |
| Base Temperature (liquid helium) | 4.2 K |
| Helium Consumption | 0.7 L/hr at 4.2 K |
| Compatible Cryogens | Liquid helium (4.2 K), pumped helium (1.7 K), liquid nitrogen (77 K) |
| Vibration Level | Nanoscale (sub-10 nm RMS, isolated from cryogen flow) |
| Bakeable to | 150 °C |
| Sealing | Oxygen-free copper gaskets on all UHV flanges |
| Optical Access | Interchangeable windows with customizable materials (e.g., fused silica, CaF₂, sapphire) |
| Sample Stage | Flat, electrically isolated, height-adjustable (±1.52″ range) |
| Temperature Sensing | Calibrated silicon diode (±12 mK accuracy, 4-ft lead), control-grade silicon diode (±0.5 K), 36 Ω foil heater |
| Electrical Feedthrough | 10-pin hermetic connector |
| Radiation Shield | Nickel-plated OFHC copper |
| Included | LT3-OM cold stage, coaxial flow helium transfer line, stainless-steel instrument panel, dewar adapter, flow control board, radiation shield |