Common Laboratory Equipment
Filter
Showing 1081–1110 of 17605 results
| Brand | AVIDITY |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | Cascada II.I |
| Pricing | Upon Request |
| Purified Water Grade | ASTM Type I (Ultra-Pure) |
| Resistivity | 18.2 MΩ·cm @ 25 °C |
| Total Organic Carbon (TOC) | <5 ppb |
| Microbial Count | <0.1 CFU/mL |
| Endotoxin Level | <0.001 EU/mL |
| Particulates (>0.2 µm) | <1 particle/mL |
| Origin | Tianjin, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Classification | Domestic Production |
| Model | AVT |
| Pricing | Available Upon Request |
| Natural Frequency | 2.5–2.7 Hz |
| Vibration Isolation Method | Pneumatic Air Spring Isolation |
| Damping Mechanism | Adjustable Orifice Damping |
| Leveling Method | S-Type — Auto-Leveling via Integrated Precision Inclinometer |
| Load Capacity | 55–70 kg |
| Tabletop Dimensions (W × D × H mm) | 430×530×60±3 |
| Unit Weight | 18–32 kg |
| Standard Accessories | S-Type — 3 m PU Air Hose (Ø6 mm) + Quick-Connect Fitting |
| Brand | AWA |
|---|---|
| Model | AWA5000 |
| Compliance | GB/T 3785.1–2023 / IEC 61672-1:2013 Class 1 |
| Standard Conformance | HJ 907–2017 |
| Dynamic Range | 123 dB |
| Display | 4.3-inch capacitive touchscreen |
| Internal Storage | 16 GB (expandable to 64 GB via microSD) |
| Communication | Wi-Fi, 4G LTE, Bluetooth |
| Positioning | Integrated GPS + network-assisted positioning |
| Audio Recording | High-fidelity time-stamped PCM recording |
| Frequency Analysis | Real-time 1/1 and 1/3-octave band analysis |
| Power Supply | Integrated outdoor-rated power management system |
| Optional Modules | Meteorological sensor suite, traffic flow counter, PTZ camera, LED display panel, acoustic source localization unit |
| Brand | Hangzhou Aihua |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | AWA2000 |
| Pricing | Available Upon Request |
| Translation Stage | Consult Manufacturer |
| Brand | AWL |
|---|---|
| Origin | United Kingdom |
| Model | CFC15 |
| Temperature Range | Ambient to 80 °C (standard configuration) |
| Temperature Control Accuracy | < 0.5 °C |
| Filtration Throughput Options | 2.5 L/h, 6.5 L/h, 25 L/h |
| Filter Media Pore Size | 2–40 µm |
| Filter Disc Material | 316L Stainless Steel or Hastelloy® |
| Operating Vacuum | < 40 mbar (absolute) |
| Compressed Air Requirement | 4–6 bar, 1.0 L/min |
| Wetted Materials | Fully customizable per application |
| Compliance | ISO 9001 certified design and manufacturing |
| Regulatory Alignment | Supports GLP/GMP workflows with audit-ready operation logs |
| Brand | Axetris |
|---|---|
| Origin | Switzerland |
| Model | EMIRS50_AT06T_BT170 |
| Housing | TO-46 metal can with protective cap |
| Emission Spectrum | 2–14 µm (blackbody-like) |
| Modulation Capability | Electrical (chopper-free) |
| Window Options | Sapphire or Barium Fluoride (BaF₂) |
| Typical Radiant Power | ~15 mW @ 5 V |
| Thermal Time Constant | < 10 ms |
| Operating Voltage Range | 3.3–6 V DC |
| Lifetime | > 50,000 hours (at rated conditions) |
| MEMS Structure | Silicon-based microheater with dielectric emissive coating |
| Brand | AXIS-TEC |
|---|---|
| Origin | USA |
| Model | PE-100 |
| RF Frequency | 13.56 MHz |
| RF Power | 0–300 W (automatically adjustable) |
| Chamber Dimensions | 305 × 368 × 305 mm (L×D×H) |
| Chamber Volume | 34 L |
| Chamber Material | T6-aluminum monolithic construction |
| Operating Pressure Range | 1–2000 mTorr |
| Gas Flow Control | 0–50 sccm with precision needle valve |
| Vacuum Gauge | Pirani gauge (0–1 Torr) |
| Gas Inlet | Single or multi-channel configurable |
| Control System | PLC-based HMI automation |
| Configuration Options | Plasma cleaning, isotropic plasma etching, anisotropic RIE, and switchable mode architecture |
| Brand | AXIS-TEC |
|---|---|
| Origin | USA |
| Model | PE-75 |
| RF Frequency | 13.56 MHz |
| Power Output | 0–150 W (automatically regulated) |
| Chamber Dimensions | Cylindrical, ID 273 mm × Depth 254 mm |
| Chamber Volume | 13.8 L |
| Chamber Material | T-6 Aluminum Monolithic Construction |
| Operating Gas | Single- or Multi-Gas Inlet |
| Vacuum Range | 1–2000 mT (via Pirani gauge, 0–1 Torr) |
| Gas Flow Control | 0–25 sccm with Precision Needle Valve |
| Control Mode | Fully Automated |
| Brand | AXIS-TEC |
|---|---|
| Origin | USA |
| Model | PlasmaSTAR100 / PlasmaSTAR200 |
| RF Frequency | 40 kHz (LF) or 13.56 MHz |
| RF Power | 600 W |
| Chamber Volume | 10 L |
| Chamber Material | Anodized Aluminum |
| Maximum Substrate Size | 8-inch wafer |
| Process Gas Pressure | 10 PSI |
| Control Interface | Touchscreen PC with Multi-step Programmable Logic |
| Vacuum System | Rotary Vane Pump (standard), optional Roots-boosted configuration |
| Gas Delivery | Mass Flow Controllers (MFCs) standard, downstream pressure controller optional |
| Brand | AYAN |
|---|---|
| Origin | Zhejiang, China |
| Model | AYAN-100LB |
| Nitrogen Purity | 99.999% |
| Output Flow | 100 L/min |
| Output Pressure | 0.6 MPa |
| Power Supply | 380 V ±10%, 50 Hz ±5% |
| Noise Level | ≤65 dB(A) |
| Dimensions (W×D×H) | 1400 × 950 × 1300 mm |
| Weight | 380 kg |
| Principle | Pressure Swing Adsorption (PSA) |
| Integrated Components | Air Compressor, Refrigerated Dryer, Multi-Stage Filtration System, Carbon Molecular Sieve (CMS) Adsorption Towers, N₂ Buffer Tank, Real-Time Purity Analyzer & Flow Meter |
| Brand | AYAN |
|---|---|
| Origin | Zhejiang, China |
| Model | AYAN-20L |
| Nitrogen Generation Principle | Imported Hollow-Fiber Membrane Separation |
| Output Flow Rate | 20 L/min |
| Output Pressure | 0.6 MPa |
| Nitrogen Purity | 99.9% |
| Dew Point | -40 °C |
| Compliance | CE-marked design (intended for lab use under ISO 8573-1 Class 3/4 air quality input) |
| Brand | AYAN Instruments |
|---|---|
| Origin | Zhejiang, China |
| Model | AYAN-20LG |
| Nitrogen Generation Principle | Pressure Swing Adsorption (PSA) using Carbon Molecular Sieve (CMS) |
| Output Flow Rate | 20 L/min |
| Output Pressure Range | 0–0.6 MPa |
| Nitrogen Purity | 99.9% |
| Dew Point | –45 °C |
| Filtration | Triple-stage filtration (particulates < 0.01 µm, oil aerosol < 0.003 mg/m³) |
| Integrated Air Compressor | Yes |
| Power Supply | 220 V, 50 Hz |
| Total Power Consumption | 2600 W |
| Dimensions (W×D×H) | 500 × 330 × 710 mm |
| Compliance | Designed for GLP-compliant lab environments |
| supports audit-ready operation per ISO 8573-1 | 2010 Class 2 (air quality) and ASTM D6352–18 (gas purity verification) |
| [Brand | AYAN |
|---|---|
| Origin | Zhejiang, China |
| Model | AYAN-35L |
| Nitrogen Generation Principle | Hollow-Fiber Membrane Separation |
| Output Flow Rate | 35 L/min (not mL/h — corrected per industry standard) |
| Output Pressure Range | 0–0.6 MPa (factory-set at 0.3 MPa) |
| Nitrogen Purity | ≥99% (v/v) |
| Dew Point | −45 °C |
| Filtration Stages | Triple-Stage Integrated Filtration (particulate < 0.01 µm |
| Display | Digital N₂ purity & flow readout |
| Control | Fully Automated PLC-based operation with self-diagnostic alerts |
| Safety | Integrated pressure-regulated buffer tank with ASME-compliant safety valve] |
| Brand | AYAN |
|---|---|
| Origin | Zhejiang, China |
| Model | AYAN-500MLG |
| Nitrogen Generation Principle | Electrolytic (Aqueous Alkaline Electrolyte) |
| Output Flow Rate | 500 mL/min |
| Nitrogen Purity | 99.999% |
| Dew Point | −40 °C |
| Integrated Buffer Tank | Yes |
| Safety Valve | Compliant with ISO 4126-1 |
| Mobility | Equipped with Locking Casters |
| Display | Digital LED Flow & Status Monitor |
| Control System | Microprocessor-Based Auto-Control with Self-Diagnostic Logic |
| Brand | AYAN |
|---|---|
| Origin | Zhejiang, China |
| Model | AYAN-60LG |
| Nitrogen Generation Principle | Membrane Separation |
| Output Flow Rate | 60 L/min |
| Output Pressure | 0–0.6 MPa |
| Nitrogen Purity | 99.9% |
| Dew Point | –45 °C |
| Filtration Stages | Three-Stage |
| Power Consumption | 3800 W |
| Input Voltage | 220 V / 50 Hz or 380 V |
| Dimensions (L×W×H) | 500 × 330 × 710 mm (main unit), 400 × 300 × 1300 mm (optional cabinet) |
| Brand | AYAN |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | AYAN-95LB |
| Output Flow Rate | 95 L/min |
| Output Pressure | 0–0.6 MPa |
| Nitrogen Purity | 99% |
| Dew Point | −40 °C |
| Nitrogen Generation Principle | Pressure Swing Adsorption (PSA) |
| Brand | AYAN |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | AYAN-F100-S |
| Price | USD 25,000 (FOB) |
| Feed Rate | 0.5–5.0 L/h |
| Effective Evaporation Area | 0.15 m² |
| Evaporator Internal Diameter | 100 mm |
| Collection Flask Capacity | 2 L |
| Condenser Surface Area | 0.25 m² |
| Brand | AYAN |
|---|---|
| Origin | Zhejiang, China |
| Model | AYAN-F100-S |
| Feed Capacity | 5 L |
| Effective Evaporation Area | 0.5 m² |
| Evaporator Inner Diameter | 220 mm |
| Condensing Area | 0.65 m² |
| Collecting Flask Capacity | 5 L |
| Vacuum Level (No-Load) | ≤10 Pa |
| Heating Temperature Range | Ambient to 200 °C |
| Rotational Speed | ≤450 rpm |
| Motor Power | 120 W |
| Material | 304/316L Stainless Steel & PTFE Seals |
| Cooling | Integrated Chiller |
| Cold Trap | Standard |
| External Condenser | Optional |
| [Brand | ANYAN (Hangzhou Anyan Instrument Co., Ltd.) |
|---|---|
| Origin | Zhejiang, China |
| Model | AYAN-H1000ml |
| Hydrogen Generation Principle | Pure Water Electrolysis (KOH-free PEM-compatible design) |
| Output Flow Rate | 0–1000 mL/min |
| Output Pressure | 0–0.4 MPa (adjustable, factory-set at 0.3 MPa) |
| Hydrogen Purity | ≥99.999% |
| Power Consumption | ≤180 W |
| Input Voltage | 220 V ±10%, 50 Hz ±5% |
| Operating Temperature | 0–50 °C |
| Relative Humidity | ≤85% RH |
| Dimensions (W×D×H) | 310 × 190 × 360 mm |
| Weight | 12 kg |
| Gas Outlet | 1/8″ NPT or Φ3 mm stainless steel tubing |
| Water Refill | Automatic + manual backup |
| Safety Protections | Low-water-level alarm, overpressure shutdown, hydrogen leak detection, dual-stage overcurrent protection |
| Compliance | Designed to meet ISO 8573-1 Class 1 compressed gas purity requirements for GC carrier gas] |
| Brand | AYAN |
|---|---|
| Origin | Zhejiang, China |
| Model | AYJ-2 |
| Feed Rate | 1–100 kg/h |
| Collection Vessels | 2 |
| Tower Material | Borosilicate Glass 3.3 |
| Tower Height | 0.5–2 m (customizable) |
| Heating Temperature Range | Ambient +10 °C to 300 °C |
| Ultimate Vacuum | ≤0.1 mbar |
| Condenser Type | Vertical |
| Effective Packing Height | 1 m |
| Tower Diameter (ID) | 25 mm |
| Flask Volume | 2 L |
| Power Supply | 220 V, 50/60 Hz, 1P |
| Brand | AYAN Instruments |
|---|---|
| Model | B80 |
| Origin | Zhejiang, China |
| Equipment Type | Laboratory-Scale Vacuum Thin-Film Evaporator |
| Application Scope | Solvent Removal, Molecular Distillation, High-Viscosity Feedstock Purification, Heat-Sensitive Compound Concentration |
| Brand | AYAN |
|---|---|
| Origin | Zhejiang, China |
| Model | CY-SXT-02 |
| Temperature Range | Room Temp +5°C to 100°C |
| Channel Capacity | 2/4/6 parallel extraction positions |
| Sample Weight per Vessel | 0.5–20 g |
| Extraction Flask Volume | 500 mL (2-channel) |
| Heating Power | 300 W |
| Power Supply | 220 V ±10 V, 50 Hz |
| Dimensions (W×D×H) | 425×230×840 mm |
| Net Weight | 17 kg |
| Compliance | Designed in accordance with GB 5512–1985 for crude fat determination |
| Brand | AYAN Instruments |
|---|---|
| Origin | Zhejiang, China |
| Model | AYAN-DC30G |
| Heating Method | Dry-block heating |
| Temperature Range | Ambient +5°C to 150°C |
| Temperature Uniformity | ±0.5°C |
| Sample Capacity | 30 positions |
| Tube Diameter Compatibility | 16 mm (optional) |
| Gas Flow Control Range | 0–999 mL/min |
| Programmable Stages | 50 segments |
| Display | 7-inch capacitive touchscreen |
| Heating Block Material | Aerospace-grade aluminum alloy |
| Gas Preheating Function | Yes (~45°C) |
| Sealing System | Dual-seal observation door with internal recirculating fan |
| Data Storage | Internal multi-session logging |
| Gas Distribution | Independent solenoid valve per channel |
| Lift Mechanism | Motorized dual-mode (fine-adjust + rapid) needle positioning |
| Compliance | Designed for GLP-compliant sample preparation workflows |
| Brand | AYAN Instruments |
|---|---|
| Origin | Zhejiang, China |
| Model | DC36S |
| Heating Method | Water Bath |
| Temperature Range | Ambient to 100 °C |
| Temperature Uniformity | ±1 °C |
| Sample Capacity | 36 positions |
| Tube Diameter Compatibility | 16 mm (optional) |
| Gas Flow Control | Independent electromagnetic valve per channel |
| Power Supply | See technical specifications |
| Auto-refill Function | Yes |
| Dual-sealed observation window system | Yes |
| Touchscreen Interface | 7-inch LCD with programmable logic |
| Program Storage | Multiple user-defined protocols (50 segments, 5 modes) |
| Safety Features | Dry-run protection, overflow outlet, lid-open alarm, auto-resume after interruption, acid-resistant surface treatment |
| Brand | AYAN Instruments |
|---|---|
| Origin | Zhejiang, China |
| Model | AYAN-F100 |
| Feed Capacity | 2 L |
| Effective Evaporation Area | 0.16 m² |
| Evaporator Internal Diameter | 100 mm |
| Condenser Area | 0.25 m² |
| Dual Collection Flasks | Yes |
| Operating Vacuum | ≤1 Pa (≤0.0075 mmHg) |
| Heating Temperature Range | Ambient to 300 °C |
| Cooling Temperature | −20 °C (Primary), −5 °C (Secondary) |
| 刮膜转子 Speed | 300 rpm |
| Motor Power | 240 W |
| Film Thickness | <0.5 mm |
| Construction Materials | SS316L + PTFE刮膜 Elements |
| Sealing | Silicone Gaskets (optional PTFE for corrosion resistance) |
| Brand | AYAN |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | AYAN-F80 Wiped-Film Molecular Distiller |
| Price | USD 12,800 (FOB) |
| Feed Rate | 0.5–4.0 L/h |
| Effective Evaporation Area | 0.1 m² |
| Evaporator Internal Diameter | 80 mm |
| Condenser Surface Area | 0.15 m² |
| Collection Vessels | 2 × standard KF-25 or ISO-KF 25 ports |
| Brand | AYAN Instruments |
|---|---|
| Origin | Zhejiang, China |
| Model | AYAN-10L PSA Nitrogen Generator |
| Nitrogen Production Principle | Pressure Swing Adsorption (PSA) |
| Output Flow Rate | 0–10 L/min |
| Output Pressure | 0–0.7 MPa |
| Nitrogen Purity | 99.999% |
| Dew Point | −40 °C |
| Brand | Anyan Instruments |
|---|---|
| Origin | Zhejiang, China |
| Model | AYAN-1LG |
| Nitrogen Generation Principle | Membrane Separation |
| Output Flow Rate | 1 L/min |
| Output Pressure Range | 0–0.6 MPa |
| Nitrogen Purity | 99% |
| Dew Point | ≤ −40 °C (typical for membrane-based systems) |
| Compliance | CE-marked design, ISO 8573-1 Class 3 compressed air input recommended |
| Power Supply | AC 220 V ± 10%, 50 Hz |
| Dimensions (W×D×H) | 360 × 280 × 520 mm |
| Net Weight | ~22 kg |
| Cooling Method | Air-cooled |
| Filtration Stages | Integrated coalescing pre-filter + activated carbon + particulate final filter |
| Brand | AYAN |
|---|---|
| Origin | Zhejiang, China |
| Model | AYAN-20L |
| Nitrogen Generation Principle | Membrane Separation |
| Output Flow Rate | 20 L/min |
| Output Pressure Range | 0–0.6 MPa |
| Nitrogen Purity | 99–99.9% |
| Dew Point | −40 °C |
| Filtration Stages | Triple-Stage Pre-Filtration |
| Brand | AYAN Instruments |
|---|---|
| Origin | Zhejiang, China |
| Model | AYAN-250LB |
| Nitrogen Production Principle | Pressure Swing Adsorption (PSA) |
| Output Flow Rate | 250 L/min |
| Output Pressure Range | 0–0.6 MPa |
| Nitrogen Purity | 99% |
| Dew Point | −40 °C |
