Common Laboratory Equipment
Filter
Showing 1051–1080 of 17605 results
| Brand | Autoscience |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | AS2060B |
| Price Range | USD 140–700 (FOB) |
| Instrument Type | General-Purpose Ultrasonic Cleaner |
| Tank Capacity | 2 L |
| Ultrasonic Frequency | 40 kHz |
| Ultrasonic Power Output | 60 W |
| Power Adjustment | Yes, 50–100% in discrete steps |
| Temperature Control | Not available |
| Timer Range | 5–30 min (mechanical timer), continuous mode supported |
| Sound-Dampening Lid | Included |
| Drain/Refill | Manual valve-controlled drainage |
| Brand | Autoscience |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | ASE-12 / ASE-16 / ASE-24 |
| Price Range | USD 420 – 690 |
| Automation Level | Semi-Automatic |
| Channel Count | 12 / 16 / 24 Parallel Channels |
| Extraction Format | Cartridge-Based Column SPE |
| Flow Rate Control | 0.1–30 mL/min (adjustable per channel via precision needle valve) |
| Solvent Compatibility | Multiple organic and aqueous solvents (e.g., methanol, acetonitrile, ethyl acetate, hexane, water, buffer solutions) |
| Sample Throughput | Simultaneous processing of 12 / 16 / 24 samples |
| Cartridge Dimensions Supported | Max. OD 15 mm × L ≤ 105 mm (compatible with 1 mL, 3 mL, 5 mL, and 6 mL SPE cartridges) |
| Solvent-Wetted Materials | Borosilicate glass vacuum manifold, PTFE-coated stainless steel valves, chemically resistant elastomer seals |
| Brand | Autoscience |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | ATBM-400B |
| Instrument Type | Stomacher (Paddle-Beating) |
| Dimensions (W×D×H) | 217 × 240 × 364 mm |
| Sample Volume Range | 30–400 mL |
| Adjustable Plate Gap | 2–10 mm (1 mm/rev) |
| Beat Frequency | 5–9 SPS (selectable) |
| Timer Modes | Preset (30–360 s) + Fine Adjustment (5–999 s) |
| Power Supply | 220 V / 50 Hz, 200 W |
| Weight | 17 kg |
| Brand | Autoscience |
|---|---|
| Origin | Tianjin, China |
| Model | UH-500B |
| Output Power | 500 W |
| Adjustable Amplitude Range | 20–100% |
| Pulse Duty Cycle | 1–90% |
| Sample Volume Capacity | 250 µL – 500 mL |
| Input Particle Size | <15 mm |
| Output Particle Size | <40 µm |
| Final Particle Distribution | 0.01–0.5 mm |
| Compatible Probe Sizes | 1/8", 3/16", 1/4", 1/2" |
| Operating Modes | Continuous & Pulsed |
| External Control Interface | Yes |
| Footswitch Optional | Yes |
| Brand | Autosense |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | APTC Series |
| Quotation | Available Upon Request |
| Temperature Range | 25°C below ambient to 80°C |
| Setpoint Range | 2°C to 70°C |
| Temperature Accuracy | ±0.5°C |
| Temperature Stability | ±0.2°C |
| Power Consumption | 180 W |
| Electrical Supply | 220 V AC, 50 Hz |
| Dimensions (W×H×D) | 220 × 185 × 282 mm |
| Net Weight | 6.5 kg |
| Brand | Autosense |
|---|---|
| Model | APTC-2 |
| Temperature Range | 25°C below ambient to 80°C |
| Setpoint Range | 2–70°C |
| Temperature Stability | ±0.2°C |
| Control Accuracy | ±0.5°C |
| Power Consumption | 180 W |
| Input Voltage | 220 V ±10%, 50 Hz |
| Dimensions (W×H×D) | 220 × 185 × 282 mm |
| Weight | 6.5 kg |
| Brand | Autosense |
|---|---|
| Model | AT-330 |
| Origin | Tianjin, China |
| Heating Method | Silicone Rubber Flexible Heater (WATLOW) |
| Temperature Control Accuracy | ±0.1 °C |
| Display | Dual 4-digit LED (Setpoint & Actual) |
| Mounting Options | Vertical or Horizontal Orientation |
| Chamber Access | Magnetic-latch Lid with Tempered Glass Viewing Window |
| Column Capacity | 1–2 columns (stainless steel spring-mounted brackets) |
| Leak Containment | Removable Drip Tray |
| Structural Stability | Optional Wide Base Plate for Vertical Configuration |
| Inlet/Outlet Routing | Chamfered Fluid Path Openings |
| Valve Mounting | Adjustable Height Injection Valve Bracket |
| Compliance | Designed for ISO/IEC 17025-compliant laboratories |
| Brand | Autosense |
|---|---|
| Model | ATP-3200 |
| Flow Rate Range | 0.25–2060 mL/min (dependent on tubing size) |
| Speed Range | 1–460 rpm, continuously adjustable |
| Speed Resolution | 0.1 rpm |
| Speed Stability | ≤ ±0.3 rpm |
| Tubing Compatibility | 14#, 16#, 25#, 17#, 18# (Pharmed®/Norprene®-equivalent silicone or thermoplastic elastomer tubing) |
| Max Fluid Pressure | 1.5 kg/cm² (≈147 kPa) |
| Operating Temperature | –10°C to 100°C (fluid), 0°C to 50°C (ambient) |
| Relative Humidity | <80% RH |
| Power Supply | 220 V ±15%, 50/60 Hz |
| Power Consumption | 150 W |
| Dimensions (W×H×D) | 120 × 230 × 270 mm |
| Net Weight | 5.5 kg |
| Direction Control | Forward/Reverse |
| Display | 4-digit LED, showing speed and flow (for three standard tubing sizes) |
| External Interface | TTL/RS-232-compatible control port for programmable automation |
| Compliance | Designed for GLP-compliant lab environments |
| Brand | Autosense |
|---|---|
| Origin | Tianjin, China |
| Model | MTN-2800D |
| Heating Method | Dry-block heating |
| Temperature Range | Ambient +5°C to 180°C |
| Temperature Stability | ±0.1°C |
| Sample Tube Diameter Compatibility | 10–30 mm |
| Nitrogen Flow Rate | 0–15 mL/min |
| Sample Positions | 12 / 24 / 40 |
| Heating Power | 350 W |
| Brand | Autosense |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MTN-2800D |
| Heating Method | Dry-block heating |
| Temperature Range | +5°C to 180°C |
| Temperature Stability | ±0.1°C |
| Sample Tube Diameter Compatibility | 10–30 mm |
| Nitrogen Flow Rate | 0–15 mL/min |
| Sample Positions | 12 |
| Heating Power | 350 W |
| Block Dimensions (Standard) | 95 W × 70 H × 75 L mm |
| External Dimensions (excl. support rod) | 240 W × 130 H × 215 D mm |
| Operating Ambient Temperature | 5–35°C |
| Power Supply | 220 V / 50 Hz |
| Safety Protections | Dual-mode overtemperature protection (upper-limit setpoint or deviation-based), integrated spill containment tray, continuous-duty thermal architecture |
| Brand | Autosense |
|---|---|
| Origin | Tianjin, China |
| Model | MTN-2800W |
| Heating Method | Water Bath |
| Temperature Range | Ambient +5°C to 100°C |
| Temperature Stability | ±0.1°C |
| Tube Diameter Compatibility | 13–19 mm |
| Nitrogen Flow Rate | 0–15 L/min |
| Sample Positions | 12 / 24 / 40 |
| Heating Power | 350 W |
| Over-Temperature Protection | 110°C |
| Timer Range | 0–99 h 59 min |
| Display | Dual digital display for set/actual temperature and timer modes (count-up/count-down) |
| Dimensions (W×H×D, main unit only) | 240 × 130 × 215 mm |
| Heating Block Size | 210 × 95 × 150 mm |
| Power Supply | 220 V / 50 Hz |
| Brand | Autosense |
|---|---|
| Origin | Tianjin, China |
| Model | MTN-2810D |
| Heating Method | Dry-block heating |
| Temperature Range | Ambient +5°C to 300°C |
| Temperature Stability | ±0.1°C |
| Sample Capacity | 8 or 12 positions |
| Tube Diameter Compatibility | 10–29 mm |
| Nitrogen Flow Rate | 0–15 L/min |
| Heating Power | 1350 W |
| Timer Range | 10 min to 99 h 59 min |
| Over-Temperature Protection | Dual-mode (upper-limit & deviation-based) |
| Temperature Output Interface | Analog signal output (0–5 V or 4–20 mA, configurable) |
| Dimensions (W×L×H, excluding support rod) | 268 × 230 × 165 mm |
| Operating Ambient | 5–35°C |
| Power Supply | 220 V / 50 Hz |
| Brand | Autosense |
|---|---|
| Origin | Tianjin, China |
| Model | MTN-5800D Electric |
| Heating Method | Water Bath |
| Temperature Range | Ambient to 96 °C (water) |
| Temperature Stability | ±0.2 °C |
| Sample Capacity | 12-position (for vessels Φ30–55 mm) / 24-position (for tubes Φ10–29 mm) |
| Gas Flow Rate | 0–25 L/min (adjustable) |
| Heating Power | 1000 W |
| Vertical Travel | Sample Tray 0–100 mm |
| Internal Tank Dimensions | Φ320 × H170 mm |
| Overall Dimensions | Φ355 × L402 × H620 mm |
| Display | LCD |
| Gas Consumption per Needle | 330 mL/min |
| Water Level Sensor | Integrated with auto-shutoff and alarm |
| Drain Valve | Yes |
| Needle Options | Disposable polypropylene or stainless steel |
| Flow Visualization | Float-type gas flow meter |
| Sample Holder Rotation | 360° continuous |
| Brand | Autosense |
|---|---|
| Model | WB Series |
| Temperature Range | Ambient to 90 °C |
| Temperature Stability | ±0.2 °C |
| Temperature Setting Resolution | 0.1 °C |
| Over-Temperature Protection Range | 25–130 °C |
| Heating Power | 1000 W |
| Oscillation Frequency | 40–100 Hz/min |
| Oscillation Amplitude | 18 mm (horizontal) |
| Bath Capacity | 20 L |
| External Dimensions | 600 mm × 300 mm × 300 mm (W × D × H) |
| Timer Range | 10–90 min |
| Display | Dual 4-digit LED (set & actual temperature) |
| Brand | AUWII® |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Regional Classification | Domestic (China) |
| Model | AR Series Industrial Circulating Chiller |
| Instrument Type | Integrated Unit |
| Cooling Method | Air-Cooled |
| Temperature Control Range | 5–35 °C |
| Refrigeration Capacity | 18–190 kW |
| Temperature Stability | ±1 °C |
| Circulating Pump Pressure | 19–55 m H₂O |
| Circulating Pump Flow Rate | 1–32 m³/h |
| Reservoir Volume | 150–900 L |
| Operating Principle | Compressor-Based Vapor-Compression Refrigeration |
| Brand | Avantium |
|---|---|
| Origin | Netherlands |
| Model | Flowrence® |
| Maximum Operating Pressure | 200 bar |
| Maximum Operating Temperature | 850 °C |
| Catalyst Bed Volume | 25–1000 µL |
| Number of Parallel Reactors | 16 (4 modules × 4 reactors) |
| Reactor Inner Diameter | 2.0–2.6 mm |
| Isothermal Zone Length | 5–15 cm (standard), up to 50 cm (custom) |
| Feed Configuration | Up to 5 gases + 2 liquids |
| Catalyst Form | Extrudates (intact or crushed) |
| Downstream Phase Separation | Capillary-free gas–liquid separation |
| Automated Liquid Sampling | Integrated |
| Temperature Control | Independent per module (4 zones) |
| Brand | Avestin |
|---|---|
| Origin | Canada |
| Model | EF-B15 |
| Instrument Type | High-Pressure Homogenizer |
| Dimensions (W×D×H) | 335 × 280 × 650 mm |
| Sample Volume per Cycle | 3–15 mL |
| Construction Material | 316L Stainless Steel |
| Sterilization | Steam-Sterilizable |
| Cooling Option | Optional Heat Exchanger |
| Pressure Adjustment | Continuously Variable |
| Brand | AVESTIN |
|---|---|
| Origin | Canada |
| Model | EmulsiFlex |
| Instrument Type | High-Pressure Homogenizer |
| Dimensions (W×D×H) | 335 × 280 × 650 mm |
| Processing Volume Range | 15–1,000,000 mL |
| Wetted Materials | Metal-to-Metal & Metal-to-Ceramic Seals Only |
| Sterilization | SIP-Compatible (Steam-in-Place), All Wetted Parts Autoclavable |
| Temperature Control | Stainless Steel Heat Exchanger Included |
| Regulatory Compliance | Designed for GLP/GMP Environments, Supports 21 CFR Part 11 Audit Trail Configuration (via optional software package) |
| Brand | AVESTIN |
|---|---|
| Origin | Canada |
| Model | B15 |
| Instrument Type | High-Pressure Homogenizer |
| Dimensions (W×D×H) | 335 × 280 × 650 mm |
| Sample Volume Range | 3–15 mL |
| Operating Pressure | 45,000 psi (3,100 bar) |
| Air Supply | 5–10 bar |
| Residual Volume | < 0.1 mL |
| Drive Mechanism | Pneumatic Single Plunger |
| Weight | 37 kg |
| Construction Material | ASTM-certified 316L stainless steel |
| Compliance | FDA-compliant materials, GMP-compatible design, no elastomeric seals in product path |
| Brand | Avestin |
|---|---|
| Origin | Canada |
| Model | EF-C3 |
| Instrument Type | High-Pressure Homogenizer |
| Dimensions (W×D×H) | 530 mm × 460 mm × 760 mm |
| Processing Capacity | 0.07–3 L/h |
| Maximum Pressure | 30,000 psi |
| Minimum Sample Volume | 7 mL |
| Sterilization | Autoclavable & SIP-Compatible (Steam-in-Place) |
| Construction | Metal-to-Metal & Metal-to-Ceramic Seals, O-Ring-Free Fluid Path |
| Brand | AVESTIN |
|---|---|
| Origin | Canada |
| Model | EmulsiFlex-C3 |
| Instrument Type | High-Pressure Homogenizer |
| Dimensions (W×D×H) | 530 × 460 × 760 mm |
| Processing Volume Range | 7–3000 mL |
| Maximum Operating Pressure | 200 MPa (30,000 psi) |
| Sterilization | Direct Steam-in-Place (SIP) |
| Construction Materials | FDA-compliant 316L stainless steel |
| Compliance | Designed for GMP environments, SIP-capable, seal-free fluid path |
| Brand | Avestin |
|---|---|
| Origin | Canada |
| Model | EF-C5 |
| Instrument Type | High-Pressure Homogenizer |
| Dimensions (W×D×H) | 430 × 160 × 320 mm |
| Processing Capacity | 7 mL – 5 L/h |
| Maximum Pressure | 30,000 psi |
| Sterilization | Fully Autoclavable & SIP-Compatible |
| Valve Design | Metal-to-Metal / Metal-to-Ceramic Sealing |
| Power Requirement | None (Hydraulically Actuated) |
| Temperature Control | Integrated Jacketed System |
| Optional Integration | In-Line Extrusion Module with 50/100/200/400 nm Track-Etched Membranes |
| Brand | AVESTIN |
|---|---|
| Origin | Canada |
| Manufacturer | Avestin Inc., Ottawa, Canada |
| Model | EmulsiFlex-C5 |
| Instrument Type | High-Pressure Homogenizer |
| Operating Pressure Range | 500–30,000 psi (3.4–207 MPa) |
| Sample Volume Range | 7–5,000 mL |
| Flow Rate | 1–5 L/h |
| Dimensions (W×D×H) | 100 × 200 × 300 mm |
| Drive System | Pneumatic Single Plunger |
| Homogenizing Valve | Wear-Resistant Ceramic |
| Temperature Control Range | −25 to 200 °C (via external bath) |
| Sterilization | SIP (Steam-in-Place) and CIP (Clean-in-Place) compliant |
| Materials | Electropolished 316L stainless steel and FDA-compliant ceramic components |
| Regulatory Compliance | Designed and validated per GMP, FDA 21 CFR Part 11 (audit trail capable), ISO 13485, and USP <1043> for sterile processing equipment |
| Brand | Avestin |
|---|---|
| Origin | Canada |
| Model | EmulsiFlex-C50 |
| Maximum Operating Pressure | 30,000 psi (200 MPa) |
| Flow Rate | 15–50 L/h |
| Minimum Sample Volume | 25 mL |
| Drive Type | Pneumatic Dual-Piston |
| Chamber Material | ASTM-certified 316L stainless steel |
| Sterilization | In-line steam sterilization (SIP) |
| Compliance | FDA-compliant materials, GMP-compatible design |
| Dimensions (W×D×H) | 450 × 760 × 500 mm |
| Sample Compatibility | Aqueous & organic suspensions, liposomes, emulsions, nanocrystals, cell lysates |
| Brand | Avestin |
|---|---|
| Origin | Canada |
| Manufacturer | Avestin Inc., Ottawa, Canada |
| Model | EmulsiFlex-C55 |
| Instrument Type | High-Pressure Homogenizer |
| Dimensions (W×D×H) | 600 × 430 × 540 mm |
| Processing Volume Range | 30–55,000 mL |
| Maximum Operating Pressure | 30,000 psi (207 MPa) |
| Flow Rate | Up to 55 L/h |
| Minimum Sample Volume | 7 mL |
| Drive Mechanism | Pneumatic Dual-Piston |
| Material Construction | Electropolished ASTM F899 316L Stainless Steel |
| Sterilization | SIP/CIP-Compatible Design |
| Regulatory Compliance | FDA 21 CFR Part 11–ready architecture, GMP-compliant construction, USP <1043> and <1207> aligned |
| Brand | Avestin |
|---|---|
| Origin | Canada |
| Manufacturer | Avestin Inc., Ottawa, Canada |
| Model | EmulsiFlex-D20 |
| Instrument Type | High-Pressure Homogenizer |
| Operating Pressure | 35,000 psi (2,413 bar), typical working pressure up to 30,000 psi (2,070 bar) |
| Flow Rate | 20 L/h |
| Minimum Sample Volume | 50 mL |
| Residual Volume | < 1 mL |
| Drive System | Electric single-plunger pump |
| Dimensions | 730 × 600 × 640 mm |
| Weight | 120 kg |
| Power Supply | 3-phase, 50/60 Hz, 230/400 V |
| Safety Features | Automatic circuit cutoff, transient overpressure tolerance up to +20% |
| Construction Material | 316L stainless steel (entire fluid path) |
| Compliance | GMP-compliant design, FDA-compliant materials per 21 CFR Part 11 and USP <1058>, zero elastomeric seals in product-contact zones |
| Optional Accessories | Sterile filtration extruder, integrated heat exchanger |
| Brand | AVESTIN |
|---|---|
| Origin | Canada |
| Model | LF-1 |
| Type | Manual Piston-Driven Extrusion Device |
| Dimensions (W×D×H) | 280 × 40 × 40 mm |
| Sample Volume Range | 0–1 mL |
| Membrane Compatibility | Polycarbonate (PC) Track-Etched Filters (common pore sizes: 100 nm, 200 nm, 400 nm, 800 nm, 1 µm) |
| Construction | Stainless Steel Housing & Anodized Aluminum Components |
| Residual Volume | < 5 µL |
| Regulatory Compliance | Designed for GLP-compliant lab environments |
| Brand | Avestin |
|---|---|
| Origin | Canada |
| Model | LF-50 |
| Instrument Type | High-Pressure Extrusion System |
| Dimensions (W×D×H) | 280 × 460 × 260 mm |
| Sample Volume Range | 5–50 mL per run |
| Compatible Membrane Pore Sizes | 10 nm – 1.0 µm (polycarbonate track-etched membranes) |
| Maximum Operating Pressure | 10,000 psi (69 MPa) |
| Material Contact Path | 316 Stainless Steel, PTFE, and Anodized Aluminum |
| Compliance | Designed for GLP-compliant lab environments |
| Brand | AVESTIN |
|---|---|
| Origin | Canada |
| Model | LiposoFast LF1 |
| Actuation | Manual |
| Sample Volume per Extrusion | 1 mL (2 × 500 µL syringes) |
| Minimum Sample Volume | 0.1 mL |
| Residual Volume | 0 µL |
| Available Membrane Pore Sizes | 50, 100, 200, 400, 800, and 1000 nm |
| Optional Temperature Control | Water-bath compatible |
| Weight | <2 kg |
| Compliance | Designed for GLP-compliant lab environments |
| Brand | AVESTIN |
|---|---|
| Origin | Canada |
| Model | LipoSofast |
| Sample Volume per Cycle | 1 mL (2 × 500 µL syringes) |
| Minimum Sample Volume | 0.1 mL |
| Residual Volume | 0 µL |
| Available Polycarbonate (PC) Membrane Pore Sizes | 50, 100, 200, 400, and 800 nm |
| Temperature Compatibility | Water-bath compatible for thermal control (e.g., 4–40 °C) |
| Weight | < 2 kg |
| Construction | Borosilicate glass syringes, stainless steel housing, chemically resistant seals |