| Brand | Paratronix |
|---|---|
| Origin | USA |
| Model | V494 (Vertical) / H1092 (Horizontal) |
| Voltage Options | Internal Transformer Supported |
| Cooling | Integrated Mechanical Chiller (LN₂-Free) |
| Control System | PLC with Touchscreen HMI (Rotating & Tilting Pod), USB & Ethernet Connectivity |
| Operation Modes | Manual, Semi-Automatic Batch, Recipe-Driven Deposition |
| Safety Features | Over-Temperature Cut-off, Vacuum-Level Interlock, Alarm History Logging |
| Compliance | UL 508A (US/CAN), CE Marked |
| Warranty | 1 Year |
| Brand | Park Accurion |
|---|---|
| Origin | Germany |
| Model | Accurin i4 |
| Isolation Start Frequency | 0.6 Hz |
| Peak Isolation Performance | −40 dB at 10 Hz (99% vibration attenuation) |
| Settling Time | 0.3 s |
| Degrees of Freedom | 6-DOF active compensation |
| Power Supply | Standard AC outlet (no compressed air required) |
| Load Auto-Adaptation | Yes |
| Transport Lock | Integrated and automatic |
| Structural Stiffness | High intrinsic rigidity for positional stability |
| Compliance | Designed for ISO 14644-1 Class 5–8 cleanroom environments and compatible with GLP/GMP-aligned lab infrastructure |
| Brand | Park Accurion |
|---|---|
| Origin | Germany |
| Model | Accurion Nano Series |
| Type | Active 6-DOF Vibration Isolation System |
| Operating Frequency Range | Active isolation from 0.7 Hz, passive isolation up to 200 Hz |
| Setup Time | < 0.3 s |
| Power Supply | Standard AC mains (no compressed air required) |
| Controller | External low-heat, EMI-isolated electronics unit |
| Structural Frame | Optional welded steel support table with high horizontal & vertical stiffness |
| Compliance | Designed for ISO 14644-1 Class 5 cleanroom-compatible environments and GLP/GMP-aligned lab infrastructure |
| Sample Load Capacity | Optimized for light-weight, high-sensitivity instruments (e.g., AFM, optical interferometers, nanoindenter stages) |
| Brand | Park SYSTEMS |
|---|---|
| Origin | Germany |
| Model | i4 |
| Dimensions | 400 × 500 × 90 mm |
| Payload Capacity | 0–120 kg |
| Active Isolation Bandwidth | 0.6/1 Hz to 200 Hz |
| Degrees of Freedom | 6-DOF |
| Settling Time | ≤ 0.3 s |
| Power Supply | Standard AC Mains (No Compressed Air Required) |
| Stiffness at 1 Hz | 20–30× Higher Than Passive Air Tables |
| Brand | Parker |
|---|---|
| Origin | USA |
| Model | CDAS HL 65 |
| Flow Rate | 55–300 m³/h |
| Operating Pressure | 4–16 bar |
| Pressure Dew Point | –20 °C to –70 °C |
| Filter Certification | ISO 8573-1 compliant (OIL-X series) |
| Desiccant Cartridge Lifetime | 5 years |
| Warranty | 10 years |
| Installation | Pallet-truck compatible |
| End Cap Type | Threaded |
| Purge Control | Tool-free adjustable minimum operating pressure setting |
| Flow Optimization | Low-pressure-drop valve architecture with robust cylinder design |
| Brand | Parker DH |
|---|---|
| Origin | United Kingdom |
| Model | HFX |
| Nitrogen Generation Principle | Membrane Separation |
| Output Flow Rate | 40–1200 L/min |
| Output Pressure | 4–10 bar |
| Nitrogen Purity | 95–99.5% |
| Dew Point | −50 °C |
| Brand | Parker DH |
|---|---|
| Origin | United Kingdom |
| Model | LCMS20-0 |
| Nitrogen Generation Principle | Pressure Swing Adsorption (PSA) |
| Output Flow Rate | 20 L/min |
| Output Pressure | 100 psi (7 bar) |
| Nitrogen Purity | ≥99.9% |
| Dew Point | −40 °C |
| Dimensions (W×H×D) | 510×705×555 mm |
| Weight | 89 kg |
| Compressor Integration | Air-integrated (LCMS20-1 variant available) |
| Compliance | ISO 9001 certified design, CE marked, compliant with IEC 61010-1 for laboratory equipment safety |
| Brand | Parker |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | 20H / 40H / 60H |
| Hydrogen Generation Principle | Pure Water Electrolysis |
| Output Flow Rate | 160–500 mL/min (model-dependent) |
| Output Pressure | 5–100 psi (adjustable) |
| Hydrogen Purity | ≥99.9999% |
| Power Consumption | 50 W (at nominal load) |
| Gas Outlet | 1/8″ Swagelok® compression fitting |
| Dimensions (W×H×D) | 245 × 643 × 724 mm |
| Weight | 34 kg |
| Dryer Type | Integrated desiccant-based purification module |
| Safety Certifications | CE, UKCA, UL-compliant design architecture |
| Compliance | Designed to meet ISO 8573-1:2010 Class 1 for gaseous impurities (H₂O, O₂, total hydrocarbons), compatible with GLP/GMP laboratory environments and FDA 21 CFR Part 11 data integrity requirements when integrated with validated software |
| Brand | Parker DH |
|---|---|
| Origin | United Kingdom |
| Model | G6 / G7 |
| Nitrogen Flow Rate | 0.6 L/min (G6), 3.0 L/min (G7) |
| Air Flow Rate | 1.5–3.0 L/min (G6), 3.0 L/min (G7) |
| Nitrogen Purity | ≥99.999% |
| Dew Point (Air) | ≤–40 °C |
| Outlet Pressure | 5 bar |
| Dimensions (W×H×D) | 345×842×413 mm (G6), 345×874×663 mm (G7) |
| Weight | 54 kg (G6), 80 kg (G7) |
| Integrated Oil-Free Compressor | Yes |
| Brand | Parker DH |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | H-MD |
| Hydrogen Generation Principle | Deionized Water Electrolysis |
| Hydrogen Purity | 99.99995% |
| Power Consumption | 100 W |
| Flow Rates | 160 / 250 / 500 / 1100 mL/min |
| Dryer Technology | Regenerable Dual-Column Micro Dryer |
| Moisture Content | <1 ppm |
| Safety | 7-Mode Fault Protection System |
| Compliance | ISO 9001 Certified Design |
| Brand | Parker Domnick Hunter DH |
|---|---|
| Origin | United Kingdom |
| Model | Hunter H |
| Hydrogen Generation Principle | Pure Water Electrolysis |
| Output Pressure | 5–100 psi |
| Hydrogen Purity | >99.99995% |
| Power Consumption | 100 W |
| Certifications | CE, UL |
| Water Reservoir Capacity | 5 L |
| Continuous Operation | 24/7, 365 days/year |
| Safety Features | Automatic H₂ Leak Detection, Water Level & Conductivity Monitoring, Self-Diagnostic System, Eco-Friendly Filter |
| Optional | Auto-Refill Function |
| Compliance | ISO 9001 certified manufacturer |
| Brand | Parker Domnick Hunter |
|---|---|
| Origin | United Kingdom |
| Model | LCMS64/65 (Hunter Series) |
| Nitrogen Generation Principle | Pressure Swing Adsorption (PSA) with Carbon Molecular Sieve |
| Output Flow Rate | 18 L/min |
| Output Pressure | 7 bar |
| Nitrogen Purity | >99.999% (for collision gas stream) |
| Dew Point | −40 °C |
| Certifications | CE, UL |
| Compliance | ISO 9001 certified manufacturing |
| Phthalate-Free Construction | Yes |
| Integrated Oil-Free Compressor | Yes |
| Control Interface | LCD microprocessor-based controller |
| Monitoring | Five inline pressure gauges |
| Maintenance Alerts | Automated system diagnostics and service prompts |
| Brand | Parker DH |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | NITROSOURCE PSA |
| Nitrogen Generation Principle | Pressure Swing Adsorption (PSA) |
| Output Flow Rate | 55–2600 L/min |
| Output Pressure | 4–11 bar |
| Nitrogen Purity | 95%–99.9995% |
| Dew Point | −40 °C |
| Brand | Supelco |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | 18L |
| Flow Rate | 18 L/min |
| Output Pressure | 7 bar (100 psig) |
| Nitrogen Purity | 99.5% |
| Dew Point | ≤ −50 °C |
| Inlet Air Pressure | 8.5 bar (125 psig) |
| Power Supply | 110 VAC, 50–60 Hz, 50 W |
| Dimensions (H×W×D) | 84 × 36 × 46 cm |
| Weight | 75 kg |
| Connection | 1/4" Swagelok® |
| Technology | Pressure Swing Adsorption (PSA) with Carbon Molecular Sieve (CMS) |
| Compressor | Integrated oil-free air compressor |
| Brand | Parker DH |
|---|---|
| Origin | United Kingdom |
| Model | UHP-10ZA-S, UHP-35ZA-S, UHP-50ZA-S, UHP-75ZA-S, UHP-150ZA-S, UHP-200ZA-S, UHP-300ZA-S |
| Hydrocarbon Content | < 0.1 ppm |
| Output Flow Rate | 1.0–30.0 L/min |
| Dew Point | ≤ –40 °C (typical, after integrated drying) |
| Inlet Connection | 1/8″ or 1/4″ Swagelok® |
| Outlet Connection | 1/8″ or 1/4″ Swagelok® |
| Dimensions (W×H×D) | 340 × 455 × 425 mm (UHP-10ZA-S to UHP-75ZA-S) |
| Weight | 10.2–14.2 kg |
| Filtration Stages | OIL-X EVOLUTION A0 (coalescing), catalytic oxidation unit, OIL-X EVOLUTION AA (0.01 µm final particulate) |
| Brand | Parker DH |
|---|---|
| Origin | United Kingdom |
| Model | UHPN2-550C-E / UHPN2-750C-E / UHPN2-1500C-E / UHPN2-3000C-E |
| Nitrogen Purity | >99.9995% |
| Flow Rate | 0.55–3.0 L/min |
| Outlet Pressure | 5–7 bar (adjustable) |
| Integrated Oil-Free Compressor | Yes |
| Air Inlet Requirement (for non-C models) | 3–11.7 L/min @ 9 bar |
| Dimensions (W×H×D) | 345×869×417 mm (UHPN2-550/750-C) / 345×869×667 mm (UHPN2-1500/3000-C) |
| Weight | 44–93 kg |
| Compliance | ISO 9001 certified design, CE marked, meets IEC 61000-6-3/6-4 EMC requirements |
| Brand | Parker Domnick Hunter |
|---|---|
| Origin | United Kingdom |
| Model | UHPN2 |
| Nitrogen Generation Principle | Pressure Swing Adsorption (PSA) |
| Output Flow Rate | 1 L/min |
| Output Pressure | 100 psi (5 bar) |
| Nitrogen Purity | >99.9995% |
| Dew Point | −62 °C |
| Hydrocarbon Content | <0.1 ppm |
| Particulate Class | ISO 8573-1:2010 Class 2 |
| Certifications | CE, UL |
| Compressor Type | Integrated Oil-Free Modular Air Compressor |
| Control Interface | LCD Microprocessor Controller |
| Operating Mode | ECO Adaptive Demand-Based Operation |
| Regeneration | Fully Auto-Regenerating PSA System |
| Molecular Sieve Technology | Snowstorm™ Packing |
| Noise Reduction | Acoustically Enclosed Compressor Housing |
| Monitoring | Three Independent Pressure Gauges |
| Maintenance Alert | Real-Time Predictive Maintenance Notification |
| Brand | Parker |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | UHPZN2-1000C-E |
| Nitrogen Generation Principle | Pressure Swing Adsorption (PSA) |
| Output Flow Rate | 1.0 L/min |
| Output Pressure | 5–7 bar (adjustable) |
| Nitrogen Purity | ≥99.9995% (v/v) |
| Hydrocarbon Content | <0.1 ppm (as CH₄ equivalent) |
| Dew Point | ≤–70 °C (at 5 bar) |
| Integrated Oil-Free Compressor | Yes |
| Dimensions (W×H×D) | 534 × 586 × 966 mm |
| Weight | 79.6 kg |
| Brand | Parker |
|---|---|
| Origin | USA |
| Model | FID-2500 |
| Output Purity | 99.9995% H₂ |
| Zero Air THC | <0.1 ppm |
| Capacity | Supports up to 11 FID detectors |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Dimensions | 483 × 584 × 356 mm (W × D × H) |
| Weight | 42 kg |
| Compliance | CE, UL 61010-1, ISO 8573-1 Class 1 for compressed air feed |
| Brand | Parker |
|---|---|
| Origin | USA |
| Model | MGG-400 |
| Gas Purity | <0.05 ppm THC (as methane) |
| Output Capacity | Sufficient for 5–6 FID detectors |
| Regulatory Compliance | Designed for GLP/GMP-aligned laboratories |
| Noise Level | <45 dB(A) |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Dimensions | 43.2 × 48.3 × 27.9 cm (W×D×H) |
| Weight | 22.7 kg |
| Brand | Parker |
|---|---|
| Origin | USA |
| Model Series | NitroFlow Lab, N2-04 / N2-14 / N2-22 / N2-35 / N2-45 / N2-80 / N2-135 |
| Flow Rate Range | 4–467 L/min |
| Nitrogen Purity | ≥99.5% (standard models), up to 99.999% (LCMS-SF series) |
| Technology | Hollow-Fiber Membrane Separation |
| Power Requirement | None (for air-fed split-system configurations) |
| Compliance | Phthalate-free, VOC-free, MS-compatible design |
| Brand | Parker |
|---|---|
| Origin | USA |
| Model | TOC-1250 |
| Gas Output Purity | < 0.1 ppm HC, < 0.5 ppm CO₂ |
| Flow Rate | Up to 12 L/min |
| Operating Pressure | 5–10 bar (adjustable) |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Dimensions (W×D×H) | 320 × 500 × 580 mm |
| Weight | 28 kg |
| Compliance | CE, UL 61010-1, ISO 8573-1 Class 1 for hydrocarbons and CO₂ |
| Brand | Parker |
|---|---|
| Origin | USA |
| Model | UHPN2-1100UK / HPN2-2000UK |
| Flow Rate | 1.1 L/min (UHPN2-1100UK), 2.0 L/min (HPN2-2000UK) |
| Purity | 99.9999% (UHPN2-1100UK), 99.99% (HPN2-2000UK) |
| Input | Compressed Air |
| Certification | CE, UKCA, ISO 9001-compliant design |
| Dimensions | Compact benchtop footprint (<450 mm W × 400 mm D × 500 mm H) |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Brand | Parr |
|---|---|
| Origin | USA |
| Model | Parr Modular Reaction System (MRS) with 16-Station High-Throughput Configuration |
| Reactor Type | Benchtop Batch/Parallel Autoclave Reactor |
| Heating Method | Electric Cartridge Heaters with Aluminum Block Thermal Management |
| Control Architecture | Dual 4871 Process Controllers with 16 × 4875 Power Modules |
| Pressure Rating | Up to 2000 psi (13.8 MPa) |
| Temperature Range | Ambient to 350 °C |
| Vessel Capacity | Standard 4560 Microreactors (25–100 mL) |
| Stirring | Magnetic or Mechanical Drive Options |
| Safety Features | Rupture Discs, Pressure Relief Valves, Interlocked Access Doors |
| Compliance | Designed per ASME BPVC Section VIII Div. 1, CE Marked for EU Lab Use |
| Software Interface | Parr PC-Based Control Suite (Supports ASTM E2500-19, FDA 21 CFR Part 11 Audit Trail & Electronic Signature Ready) |
| Brand | PARR |
|---|---|
| Origin | USA |
| Model | 3900 Series |
| Operating Pressure | Up to 5 atm |
| Max. Temperature | 80 °C |
| Drive Mechanism | Motorized Oscillating Motion |
| Heating Method | External Electric Heating Jacket |
| Temperature Control | PID Controller with Internal Thermocouple Feedback |
| Safety Certification | Explosion-Proof Options Available |
| Compliance | Designed for GLP-compliant hydrogenation research in pharmaceutical development |
| Brand | PARR |
|---|---|
| Origin | USA |
| Model | 4500 Series |
| Vessel Capacity | 0.075–2 L |
| Construction Material | 316 Stainless Steel |
| Maximum Operating Pressure | 3000–5000 psi (207–345 bar) |
| Vacuum Capability | Yes (rated for full vacuum to full positive pressure) |
| Drive Type | Magnetic Coupling or Gear-Driven Stirring |
| Temperature Range | Up to 540 °C |
| Certifications | ASME Section VIII Div. 1, UL/cUL, CSA, CE, ISO 9001 |
| Brand | PARR |
|---|---|
| Origin | USA |
| Manufacturer Authorization | Authorized Distributor |
| Import Status | Imported |
| Model | 4520 |
| Volume Range | 1000 mL – 2000 mL |
| Maximum Operating Pressure | 130 atm (13.2 MPa) |
| Maximum Operating Temperature | 350 °C |
| Construction Materials | 316 Stainless Steel, Hastelloy® C-276, Hastelloy® C-2000 |
| Certifications | ASME BPVC Section VIII Div. 1, CSA, CE, ISO 9001, uV Listed |
| Vacuum Capability | Not Designed for Vacuum Service |
| Regulatory Compliance | Compliant with ASTM G187 (High-Pressure Reaction Vessel Safety), FDA-relevant design principles for pharmaceutical process development |
| Brand | Parr |
|---|---|
| Origin | USA |
| Model | 4530 Series |
| Vessel Capacity | 1000 mL / 2000 mL |
| Max Operating Temperature | 350 °C |
| Max Operating Pressure | 130 atm (13.2 MPa) |
| Construction Materials | 316 Stainless Steel, Hastelloy® C-276, Hastelloy® C-2000 |
| Certifications | ASME BPVC Section VIII Div. 1, CSA, CE, ISO 9001, uV Listed |
| Brand | PARR |
|---|---|
| Origin | USA |
| Model | 4540 Series |
| Vessel Capacity | 600 mL / 1200 mL |
| Max Operating Temperature | 350 °C |
| Max Operating Pressure | 345 atm (5000 psi) |
| Construction Materials | 316 Stainless Steel, Hastelloy® C-276, Hastelloy® C-2000 |
| Certifications | ASME BPVC Section VIII Div. 1, CSA, CE, ISO 9001, uV Listed |
| Configuration | Benchtop & Floor-Standing Options |
| Brand | Parr |
|---|---|
| Origin | USA |
| Model | 4550 Series |
| Volume Options | 3.75 L (1 gal) and 7.5 L (2 gal) |
| Max Operating Temperature | 350 °C |
| Max Operating Pressure | 130 atm |
| Construction Materials | 316 Stainless Steel, Hastelloy® C-276, Hastelloy® C-2000 |
| Certifications | ASME BPVC Section VIII Div. 1, CSA, CE, uV, ISO 9001 |