Common Laboratory Equipment
Filter
Showing 11281–11310 of 17931 results
| Brand | Otisience |
|---|---|
| Origin | Tianjin, China |
| Model | AS701KDT |
| Capacity | 70 L |
| Ultrasonic Frequency | 20 / 40 / 60 kHz |
| Ultrasonic Power Output | 700 W / 1000 W |
| Power Adjustment Range | 10–100% (pulse width & amplitude modulation) |
| Heating Temperature Range | RT + 5 °C to 80 °C |
| Heating Power | 2400 W |
| Timer Range | 1–99 min |
| Lid with Acoustic Damping | Yes |
| Manual Fill/Drain | Yes |
| External Dimensions (W×L×H) | 750 × 450 × 800 mm |
| Tank Dimensions (W×L×D) | 550 × 400 × 320 mm |
| Housing Material | Anodized Aluminum |
| Brand | Otisience |
|---|---|
| Model | AS7240BDT |
| Type | General-purpose ultrasonic cleaner |
| Capacity | 7 L |
| Ultrasonic frequency | 40 kHz / 60 kHz dual-frequency selectable |
| Ultrasonic power | 240 W (adjustable from 1% to 100%) |
| Heating power | 400 W |
| Temperature range | +5 °C to 80 °C above ambient |
| Timer range | 1–999 min |
| Noise-reduction lid | Included |
| Manual drain valve | Yes |
| Tank dimensions (W×L×D) | 470 × 135 × 100 mm |
| External dimensions (W×L×H) | 530 × 160 × 270 mm |
| Construction | Stainless steel tank and housing |
| Degassing mode | Adjustable |
| Accessories | Stainless steel mesh basket and acoustic lid |
| Brand | Otisience |
|---|---|
| Model | ASM |
| Type | Benchtop Ultrasonic Processor for Pharmacopoeial Applications |
| Capacity | 4 L |
| Ultrasonic Frequency | 40 kHz |
| Nominal Ultrasonic Power | 100 W |
| Power Adjustment | Yes (Continuously Variable) |
| Temperature Control Range | Ambient to 80 °C |
| Timer Range | 1–99 min |
| Lid with Acoustic Damping | Yes |
| Manual Fill/Drain | Yes |
| Compliance | Designed to meet extraction parameter requirements specified in Chinese Pharmacopoeia (ChP) 2020 Edition and United States Pharmacopeia (USP) <561> and <701> |
| Brand | Otisience |
|---|---|
| Model | MH-2800A |
| Origin | Tianjin, China |
| Temperature Range | Ambient +5 °C to 200 °C |
| Temperature Stability | ±0.1 °C |
| Temperature Accuracy | ±0.15 °C |
| Over-Temperature Protection | 200 °C |
| Deviation Alarm Threshold | Setpoint +5 °C |
| Timer Range | 1–999 min |
| Display | Dual 4-digit LED (setpoint & actual temperature) |
| Block Capacity | 2 standard blocks or 1 double-size block |
| Heating Power | 400 W / 220 V / 50 Hz |
| External Dimensions | 240 mm (W) × 92 mm (H) × 215 mm (D) |
| Chamber Dimensions | 150 mm (W) × 51 mm (H) × 95 mm (D) |
| Brand | Otisience |
|---|---|
| Model | MH-2800E |
| Temperature Range | Ambient +5°C to 200°C |
| Temperature Stability | ±0.1°C |
| Temperature Accuracy | ±0.15°C |
| Over-Temperature Protection | 200°C |
| Deviation Alarm Threshold | Setpoint +5°C |
| Timer Range | 1–999 min |
| Display | Dual 4-digit LED (Set & Actual) |
| Chamber Dimensions (W×H×D) | 150 × 51 × 95 mm |
| External Dimensions (W×H×D) | 240 × 92 × 215 mm |
| Heating Capacity | 400 W @ 220 V, 50 Hz |
| Standard Block Capacity | 2 blocks (single-height) or 1 block (double-height) |
| Dual-Timer Function | Simultaneous display of “Set Timer” and “Elapsed Time” |
| Brand | Otisience |
|---|---|
| Model | MH-2810D |
| Temperature Range | Ambient +5 °C to 200 °C |
| Temperature Stability | ±0.1 °C |
| Temperature Accuracy | ±0.15 °C |
| Over-Temperature Protection | 200 °C |
| Deviation Alarm Threshold | Setpoint +5 °C |
| Timer Range | 1–999 min |
| Display | Dual 4-digit LED (PV/SV) |
| Heating Power | 750 W / 220 V / 50 Hz |
| External Dimensions | 320 × 92 × 270 mm (W×H×D) |
| Chamber Dimensions | 215 × 51 × 135 mm (W×H×D) |
| Block Capacity | 2 standard blocks or 1 double-size block |
| Compliance | CE-marked, RoHS-compliant, designed per IEC 61010-1 for laboratory use |
| Brand | Otisience |
|---|---|
| Model | MH-5800 |
| Origin | Tianjin, China |
| Control Range | +3°C to 80°C above ambient |
| Heating Power | 240 W |
| Temperature Accuracy | ±0.5°C |
| Temperature Stability | ±0.1°C |
| Working Surface Dimensions (L×W) | 400 mm × 300 mm |
| Overall Dimensions (L×W×H) | 515 mm × 325 mm × 45 mm |
| Power Supply | 220 V / 50 Hz |
| Fuse Rating | 3 A |
| Heating Surface Material | Stainless Steel |
| Display | Dual 4-digit LED (SV/PV) |
| Safety Features | Over-Temperature Cut-Off Protection |
| Calibration Function | User-Adjustable “Pu-b” Offset Correction |
| Brand | Otosen |
|---|---|
| Model | AM-5250A |
| Stirring Volume | 5–10 L |
| Speed Range | 0–1700 rpm |
| Temperature Control Range | Ambient to 300 °C |
| Heating Plate Max Temp | 300 °C |
| Control Method | Electronic PID |
| Temperature Accuracy | ±2 °C |
| Heating Power | 250 W |
| Plate Diameter | 150 mm |
| Dimensions (W×D×H) | 198 × 225 × 115 mm |
| Weight | 2.4 kg |
| Power Supply | 220 V / 50 Hz |
| External PT100 Sensor Port | Yes |
| Reverse Rotation | No |
| Brand | Otosenes |
|---|---|
| Model | AT-630 |
| Temperature Range | Ambient to 75 °C |
| Over-Temperature Protection | 85 °C |
| Temperature Setting/Display | 3-digit LED, 0.1 °C increment |
| Temperature Accuracy | ±0.3 °C |
| Temperature Stability | ±0.2 °C |
| Chamber Dimensions (H×W×D) | 145 × 380 × 110 mm |
| Power Consumption | 300 W |
| Column Capacity | 1–2 preparative columns |
| Heating Method | Forced-air convection with integrated axial fan |
| Enclosure Design | Magnetic-latch lid with tempered glass viewport |
| Leak Management | Integrated drip tray at chamber base |
| Fluid Path Interface | Chamfered inlet/outlet ports for low-resistance tubing routing |
| Brand | Otosenes |
|---|---|
| Model | WB-1010A |
| Heating Power | 650 W |
| Capacity | 10 L |
| Bath Chamber Dimensions (W×H×D) | 300 × 250 × 150 mm |
| Temperature Range | Ambient to 95 °C |
| Temperature Stability | ±0.2 °C |
| External Dimensions (W×H×D) | 320 × 260 × 280 mm |
| Integrated Magnetic Stirring | Yes |
| Display | Dual 4-digit LED (Set & Actual Temperature) |
| Safety Features | Over-Temperature Auto-Cut-Off, Dry-Run Protected PTC Ceramic Heater |
| Accessory Compatibility | Interchangeable Test Tube Racks, Vial Holders, and Custom Sample Carriers |
| Brand | Otseins |
|---|---|
| Model | AS7240B |
| Capacity | 7 L |
| Ultrasonic Frequency | 40 / 50 / 60 kHz |
| Ultrasonic Power Output | 240 W |
| Power Adjustment Range | 1–100% |
| Timer Range | 1–999 min |
| Tank Dimensions (W×L×D) | 470 × 135 × 100 mm |
| External Dimensions (W×L×H) | 530 × 160 × 270 mm |
| Construction | Stainless Steel Tank & Housing |
| Lid | Acoustic Damping Cover Included |
| Drain Valve | Manual |
| Degassing Function | Yes |
| Temperature Control | Not Available |
| Input Power | AC 220 V, 50/60 Hz |
| Certifications | CE-compliant design per IEC 61000-6-3 (EMC) and IEC 61010-1 (Safety) |
| Brand | Otseins |
|---|---|
| Origin | Tianjin, China |
| Model | MH-5800 |
| Temperature Range | +3 °C to 80 °C above ambient |
| Heating Power | 240 W |
| Temperature Accuracy | ±0.5 °C (adjustable) |
| Temperature Stability | ±0.2 °C |
| Temperature Resolution | 0.1 °C |
| External Dimensions (L×W×H) | 515 × 325 × 45 mm |
| Working Surface Dimensions (L×W) | 400 × 300 mm |
| Power Supply | 220 V / 50 Hz |
| Fuse Rating | 3 A |
| Control Display | Dual 4-digit LED (SV/PV) |
| Safety Features | Over-temperature cut-off with audible alarm |
| Calibration Function | User-accessible “Pu-b” offset correction |
| Heating Surface Material | Stainless steel (304) |
| Design Profile | Low-profile, compact footprint |
| Brand | Ottescience |
|---|---|
| Origin | Tianjin, China |
| Model | MH-2800D |
| Temperature Range | Ambient +5 °C to 200 °C |
| Temperature Stability | ±0.1 °C |
| Temperature Accuracy | ±0.15 °C |
| Timer Range | 1–999 min |
| Block Capacity | 2 standard blocks or 1 double-size block |
| Heating Power | 400 W @ 220 V / 50 Hz |
| External Dimensions (W×H×D) | 240 × 92 × 215 mm |
| Chamber Dimensions (W×H×D) | 150 × 51 × 95 mm |
| Over-Temperature Protection | 200 °C (hardware limit), +5 °C deviation alarm |
| Brand | Ottesens |
|---|---|
| Origin | Tianjin, China |
| Model | AS3120B |
| Capacity | 10 L (tank volume), 3 L (usable cleaning volume) |
| Ultrasonic Frequency | 40 kHz / 60 kHz dual-frequency selectable |
| Ultrasonic Power Output | 500 W (adjustable from 1% to 100%) |
| Timer Range | 1–999 min (digital control) |
| Lid | Acoustic-dampening hinged cover included |
| Drain | Manual valve |
| Construction | Stainless steel tank, corrosion-resistant aluminum housing |
| Dimensions (W×L×H) | 265 × 160 × 240 mm (external) |
| Power Input | 220 V AC, 50/60 Hz |
| Compliance | CE-marked per EN 61000-6-3 (EMC) and EN 61000-6-2 (immunity) |
| Brand | Ottesens |
|---|---|
| Origin | Tianjin, China |
| Model | MTN-5800 / MTN-5800A |
| Heating Method | Water Bath |
| Temperature Range | Ambient to 96 °C |
| Temperature Stability | ±0.2 °C |
| Tube Diameter Compatibility | 10–29 mm (standard) / 30–55 mm (optional) |
| Gas Flow Rate | 0–25 L/min |
| Sample Positions | 12 or 24 |
| Heating Power | 1000 W |
| Control Type | Manual (MTN-5800) / Motorized Vertical Adjustment (MTN-5800A) |
| Safety Features | Auto water-level cutoff, drain valve, overheat protection |
| Brand | OWIS |
|---|---|
| Origin | Germany |
| Model Series | SYS40, SYS65, SYS90 |
| Rail Heights | 40 mm, 65 mm, 105 mm |
| Rail Lengths | 40–2000 mm (custom lengths available) |
| Slide Widths | 10–110 mm |
| 4-Side Profile Heights | 40 mm, 65 mm |
| 4-Side Profile Lengths | 180–1500 mm |
| Material | High-stability aluminum alloy, black anodized |
| Mounting Compatibility | M6 threaded grids (25 mm / 50 mm pitch), slotted-hole adaptability for non-metric optical tables |
| Surface Options | Standard black anodizing |
| Optional Accessories | Integrated tape scales (metric or imperial) |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | COBRA |
| Quotation | Upon Request |
| Tank Capacity | 0.5 L |
| Unit Weight | 350 g (empty), 750 g (filled) |
| Dimensions (H × Ø) | 25 cm × 7.3 cm |
| Hose Length | 100 cm |
| Materials | Stainless Steel, Chemically Resistant Plastic & Elastomeric Components |
| Accessories | Shoulder Strap, Cleaning Brush, Filling Funnel |
| Brand | AIRSENSE |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | FOGBOOSTER |
| Quotation | Available Upon Request |
| Chamber Volume | Not Applicable |
| Heating Power | None |
| Operating Temperature | Ambient (Cold Fogging Only) |
| Disinfectant Type | Anhydrous Formulation (GD-6) |
| External Dimensions (L×W×D) | Not Specified |
| Origin | Germany |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | SMGD |
| Quotation | Upon Request |
| Chamber Volume | N/A |
| Heating Power | N/A |
| Wash Temperature | N/A |
| Cleaning Agent Type | Compatible with dry, enzymatic, and ready-to-use decontaminants |
| External Dimensions (L×W×D) | N/A |
| Brand | AIRSENSE |
|---|---|
| Origin | Germany |
| Model | Surf-Ex |
| Certification | ATEX Zone 1 & Zone 21 compliant |
| Decontamination Method | Spray-Extraction with Integrated Vacuum Recovery |
| Max Effective Coverage | 200 cm (80 in) |
| Max Hose Extension Length | 15 m |
| Collection Capacity | Compatible with standard 20–60 L containment drums |
| Pump Type | Explosion-proof diaphragm pump |
| Inlet Diameter | Large-diameter suction port for bulk particulate and sorbent material removal |
| Application Scope | Surface decon of sensitive equipment interiors, aircraft fuselages, ship compartments, infrastructure, and contaminated soil/sorbents |
| Compliance | Meets EU Directive 2014/34/EU (ATEX), IEC 60079-0/-10/-14, and supports GLP-aligned documentation workflows |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Microstat |
| Price Range | USD 42,000 – 70,000 |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Model | Microstat |
| Temperature Range | 1.5 K to 300 K (depending on configuration) |
| Cooling Method | Closed-cycle helium cryocooler or liquid helium flow cryostat |
| Optical Access | Dual windows (UV to FIR transmission, optional AR coatings) |
| Electrical Feedthroughs | Up to 24 low-noise coaxial or twisted-pair leads |
| Footprint | Compact benchtop design (< 300 mm × 300 mm base) |
| Vibration Isolation | Active/passive hybrid stage stabilization |
| Compliance | CE, UKCA, RoHS |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Model | MicrostatHiRes |
| Temperature Range | 2.7 K – 500 K (with optional rotary pump) / 3.4 K – 500 K (standard) |
| Base Temperature Stability | ±0.1 K |
| Helium Consumption at 4.2 K | < 0.70 L/hr (with low-loss transfer line) |
| Cool-down Time from RT to 4.2 K | ~15 min (with pre-cooled transfer line) |
| Working Distance | 2.2 mm |
| Sample Vibration | < 20 nm (measured in SEM environment) |
| Mass | 1.5 kg |
| Controller | Mercury iTC |
| Communication Interfaces | RS232, USB (serial emulation), TCP/IP, GPIB |
| Software Integration | LabVIEW driver library and virtual instrument support |
| Compliance | Designed for GLP/GMP-adjacent research environments |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Optistat CF (Gas Exchange) / Optistat CF-V (Vacuum) |
| Operating Modes | Pull Mode / Push Mode |
| Sample Temperature Range | 2.3–500 K (CF) / 4.2–500 K (CF-V) |
| Temperature Stability | ±0.1 K |
| Max Sample Chamber Dimensions | 30 mm (W) × 58 mm (L) |
| Sample Holder Dimensions | 20 mm (W) × 50 mm (L) |
| Sample Environment | Vacuum or Controlled Exchange Gas (e.g., He, N₂) |
| Sample Exchange Time | ~60 min |
| Cool-down to 4.2 K | ≤10 min |
| Liquid Helium Consumption at 4.2 K | <0.45 L/h (f/0.9 optical access) |
| Mass | 2 kg |
| Optional Upgrades | 500 K High-Temperature Stage |
| Optical Window Materials | Fused Silica, IR-Grade Quartz, Sapphire, CaF₂, Polyethylene |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Optistat |
| Price Range | USD 13,500 – 40,500 (FOB UK) |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Model | Optistat Dry BL4 3K |
| Cooling Base Temperature | <3 K |
| Operating Temperature Range | <3 K to 300 K |
| Optical Numerical Aperture | f/1 |
| Sample Vibration Amplitude | <10 µm |
| Vacuum System | Oil-Free Mechanical Pump Compatible (with Activated Carbon Getter) |
| Sample Exchange | Side-Access Port with Quick-Release Mechanism |
| Optional Features | Low-Vibration Mounting Stand, Rotatable Sample Stage (±5°), Electrical Feedthroughs, Interchangeable Optical Windows (CaF₂, Si, Quartz, Sapphire) |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Model | Optistat Dry |
| Temperature Range | < 3 K to 300 K |
| Cool-down Time | ≤120 min to 10 K |
| Optical Aperture | Up to 28 mm diameter |
| Numerical Aperture | f/1 |
| Electrical Feedthroughs | Up to 12 leads |
| Cooling Options | Air-cooled or water-cooled cryocooler |
| Vibration Level | < 10 µm (when mounted on optical table) |
| Compliance | Designed for ISO/IEC 17025-compliant laboratories, compatible with GLP/GMP data integrity requirements |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Optistat Dry |
| Price Range | USD 42,000 – 70,000 |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Optistat |
| Price Range | USD 42,000 – 70,000 |
| Temperature Range | 77.2–500 K (standard), up to 500 K with sapphire window option |
| Temperature Stability | ±0.1 K |
| Sample Chamber Diameter | 20 mm |
| Sample Stage Dimensions | 19 mm × 30 mm (OptistatDN), 20 mm × 50 mm (OptistatDN-V) |
| Sample Environment | Exchange gas or high vacuum |
| Sample Exchange Time | 5 min (exchange gas), 60 min (vacuum) |
| Cool-down to 77 K | ≤20 min |
| Liquid Nitrogen Capacity | 1.2 L |
| Hold Time at 77 K | ≥15 h |
| Optical Access | f/1 clear aperture |
| Weight | 5 kg |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Model | OptiStatDN |
| Temperature Range | 77 K to 300 K (standard) |
| Atmosphere | Controlled nitrogen gas (non-vacuum) |
| Temperature Stability | ±0.1 K |
| Cooling Medium | Liquid nitrogen with adjustable flow rate |
| Standard Optical Access | Four fused silica windows |
| Sample Mounting Options | Liquid cell holder (recommended with monolithic fused silica cuvettes), powder holder, thin-film holder |
| Optional Integration | Electrical transport measurement capability |
| Compatibility | Designed for coupling with UV-Vis, FTIR, THz, photoluminescence, Raman, electroluminescence, ultrafast, and photovoltaic spectroscopy systems |