| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | VHS-400 |
| Pumping Speed | Up to 4500 L/s |
| Weight | 81 kg (180 lbs) |
| Heater Power | 4400 W |
| Brand | Agilent Technologies |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | VSpin |
| Instrument Type | Benchtop Centrifuge |
| Form Factor | Robotic-Accessible, Compact Footprint |
| Cycle Time | ≤3 seconds (load + spin + unload) |
| Compatibility | Standard SBS-format microplates (96-well, 384-well, 1536-well), PCR plates, deep-well plates, skirted/unskirted formats |
| Drive System | Brushless DC motor with closed-loop speed control |
| Vibration Isolation | Integrated passive damping mounts |
| Automation Interface | RS-232, Ethernet (TCP/IP), and optional TTL I/O for robotic handshake protocols |
| Brand | AGUS |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SPS-Rx Series |
| Pricing | Available Upon Request |
| Brand | AGUS |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SPS-Sx Series |
| Pricing | Available Upon Request |
| Brand | AGUS |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SSP-1000 |
| Price Range | USD 110,000 – 138,000 |
| Maximum Substrate Diameter | φ100 mm |
| Thickness Uniformity | ±5% over φ100 mm area |
| RF Power Mode | Pulsed RF (13.56 MHz) |
| Gas Inlets | Standard 1, Optional 2 |
| Sputtering Orientation | Upward, Lateral, Downward (reconfigurable cubic chamber) |
| Target Compatibility | Metallic, Oxide (e.g., Al₂O₃, SiO₂), Nitride, and Magnetic Targets (optional) |
| Substrate Holder | Rotatable or Fixed |
| Viewport | Integrated Quartz Observation Window |
| Cathode Shielding | Removable Cathode Protection Plate with Integrated Sputter Timer for Thickness Estimation |
| Brand | Ahkemi |
|---|---|
| Origin | Anhui, China |
| Model | BEC-1500-8L |
| Max Temperature | 1400 °C |
| Temperature Uniformity | ±1 °C |
| Rated Power | 5.2 kW |
| Heating Rate | 10 °C/min (≤1400 °C) |
| Heating Element | 1500-grade U-shaped SiC rods |
| Internal Dimensions | 180 × 250 × 180 mm |
| Chamber Volume | 8 L |
| Control System | 30-segment programmable fuzzy PID with auto-tuning, over-temperature & thermocouple break protection |
| Voltage | AC 220 V, 50/60 Hz |
| External Dimensions | 590 × 580 × 780 mm |
| Net Weight | 80 kg |
| Brand | Ahkemi |
|---|---|
| Origin | Anhui, China |
| Model | BFC-1200-7.2L |
| Maximum Temperature | 1200 °C |
| Temperature Uniformity | ±1 °C |
| Rated Power | 2.5 kW |
| Heating Rate (to max temp) | 5–20 °C/min |
| Internal Dimensions | 200 × 300 × 120 mm (7.2 L) |
| Heating Element | Resistance Wire (3-sided: left, right, top) |
| Insulation | Vacuum-formed alumina fiber |
| Cooling | Dual-layer air-cooled jacket |
| Surface Temperature at Max Operation | <60 °C |
| Control System | Fuzzy PID with auto-tuning |
| Programmability | 30-segment intelligent ramp-soak profile |
| Safety Features | Over-temperature alarm, thermocouple break detection, emergency stop button |
| Input Voltage | AC 220 V, 50/60 Hz |
| External Dimensions | 440 × 500 × 600 mm |
| Brand | Ahkemi |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | BFS |
| Price Range | USD 14,000 – 21,000 (FOB Anhui) |
| Working Volume Options | 2 L, 5 L, 10 L |
| Vessel Material | Borosilicate Glass (DIN/ISO 3585 compliant) |
| Operating Pressure | Low-pressure system (max. 0.3 bar(g) standard |
| Vacuum Capability | Not designed for vacuum operation |
| Modular Configuration | Fully configurable with independent functional modules |
| Brand | Ahkemi |
|---|---|
| Origin | Anhui, China |
| Model | BFV-1200-7.2L |
| Max Temperature | 1200 °C (short-term), 1150 °C (rated) |
| Control Accuracy | ±1 °C |
| Power Rating | 2.5 kW |
| Heating Rate | 20 °C/min (to max temp) |
| Chamber Dimensions | 200 × 300 × 120 mm (7.2 L nominal volume) |
| Vacuum Level | <1000 Pa |
| Heating Method | Resistive wire (3-sided: left, right, top) |
| Control System | Fuzzy PID with auto-tuning, 30-segment programmable ramp-soak profile |
| Safety Features | Over-temperature alarm, thermocouple break detection, emergency stop button |
| Input Power | AC 220 V, 50/60 Hz |
| External Dimensions | 450 × 500 × 610 mm |
| Net Weight | 80 kg |
| Brand | Ahkemi |
|---|---|
| Origin | Anhui, China |
| Model | BFW-1200-4.5L |
| Max Temperature | 1200 °C |
| Long-Term Operating Temp | 1100 °C |
| Temperature Control Accuracy | ±1 °C |
| Rated Power | 3 kW |
| Heating Rate (to max temp) | ≤10 °C/min |
| Heating Method | Resistance Wire |
| Chamber Dimensions | 200 × 50 × 150 mm (L×W×H) |
| Nominal Volume | 4.5 L |
| Observation Window Size | 40 × 40 mm (customizable, min 3 mm aperture) |
| External Dimensions | 350 × 380 × 550 mm |
| Weight | 35 kg |
| Cooling System | Dual-layer forced-air cooling |
| Surface Temperature | ≤60 °C |
| Controller | Yudian programmable PID controller with 30-segment ramp-soak profile |
| Thermocouple Type | K-type |
| Power Supply | AC 220 V, 50/60 Hz |
| Brand | Ahkemi |
|---|---|
| Origin | Anhui, China |
| Model | CFRF-FT-L0G3 |
| Maximum Operating Pressure | 10 MPa |
| Maximum Operating Temperature | 600 °C |
| Catalyst Bed Volume | 0.5–5 mL |
| Heating Zone Length | 240 mm |
| ±2 °C Isothermal Zone Length | 50 mm |
| Brand | Ahkemi |
|---|---|
| Origin | Anhui, China |
| Model | GDT-MFC-4 |
| Gas Channels | 4 independent mass flow controlled lines |
| Control Interface | Industrial-grade 7-inch TFT touch HMI |
| Construction | Hermetically sealed stainless-steel manifold enclosure (316L tubing + dual ferrule fittings) |
| Pressure Rating | Up to 3 MPa (max operating pressure for flow sensors) |
| Pressure Measurement Range | –0.1 to 0.15 MPa (0.01 MPa per division) |
| Temperature Operating Range | 5–45 °C |
| Control Accuracy | ±1.5% of Full Scale (FS) |
| Compliance | Designed for integration with tube furnaces and atmospheric/low-pressure reaction systems |
| Power Supply | 220 VAC, 50/60 Hz |
| Communication | RS485 Modbus RTU (optional Ethernet/IP upon request) |
| Brand | Ahkemi |
|---|---|
| Origin | Anhui, China |
| Model | HTF |
| Volumes | 10 / 25 / 50 / 100 mL |
| Construction Material | Non-magnetic 0Cr18Ni9Ti stainless steel (AISI 321 equivalent) |
| Liner Material | PTFE (polytetrafluoroethylene) |
| Maximum Working Pressure | 49 bar (710 psi) |
| Maximum Operating Temperature | 500 °C |
| Sealing Type | Metal-to-metal hard seal with symmetrical bolt-tightening |
| Vacuum Rating | 49 bar (absolute) |
| Compliance | Designed for laboratory-scale hydrothermal synthesis and acid digestion under controlled high-pressure/high-temperature conditions |
| Brand | Ahkemi |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model Capacities | 300 mL / 500 mL / 1000 mL |
| Price Range | USD 0–2,800 |
| Usable Volume | Small-scale |
| Construction Material | Non-magnetic 0Cr18Ni9Ti Stainless Steel (AISI 304 equivalent) with PTFE Liner |
| Maximum Working Pressure | 30 bar (435 psi) |
| Vacuum Rating | 30 bar (absolute) |
| Max Operating Temperature | 260 °C |
| Sealing Mechanism | Groove-face self-sealing design |
| Thread Treatment | Silver-plated threads to prevent galling |
| Compliance | Designed per GB/T 150.1–2011 (Chinese pressure vessel standard), compatible with ASTM D5233 and ISO 17025 laboratory practice requirements |
| Brand | Ahkemi |
|---|---|
| Origin | Anhui, China |
| Model | 25/50/100/200 mL |
| Working Pressure | 30 bar (max) |
| Max Operating Temperature | 260 °C |
| Vessel Material | Non-magnetic 0Cr18Ni9Ti stainless steel |
| Liner Material | PTFE |
| Vacuum Rating | 30 bar |
| Volume Range | 25–200 mL |
| Compliance | Designed for ASTM E2482, ISO 17025-compliant sample digestion workflows |
| Brand | Ahkemi |
|---|---|
| Origin | Anhui, China |
| Model | KMHR-XX |
| Construction Material | Stainless Steel |
| Working Pressure | Up to 30 bar |
| Temperature Rating | Up to 260 °C |
| Vessel Capacity | 25–200 mL per unit |
| Configuration Options | 4-position or 8-position (floor-standing or desktop) |
| Vacuum Capability | Compatible with vacuum-assisted loading and inert-atmosphere operation |
| Compliance | Designed for laboratory-scale hydrothermal synthesis under controlled pressure and temperature conditions |
| Regulatory Context | Supports GLP-compliant experimental documentation when integrated with validated data logging systems |
| Brand | Ahkemi |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MA1L-P4-T3-SS1-SV |
| Vessel Capacity | 1–29 L (customizable) |
| Maximum Operating Pressure | 10 MPa |
| Maximum Operating Temperature | 300 °C |
| Construction Material | ASTM A240 UNS S31603 (316L stainless steel) or Hastelloy C-276 |
| Stirring Mechanism | High-torque magnetic coupling drive |
| Heating Method | Integrated electric heating module (for 1–10 L) or closed-loop oil bath (for ≥5 L) |
| Vacuum Capability | ≤10⁻³ mbar (typical base vacuum, not pressure rating) |
| Control Interface | Industrial-grade 10.1″ capacitive touch HMI with real-time data logging |
| Remote Access | Web-based monitoring & control via Android app and desktop software |
| Compliance | Designed per ASME BPVC Section VIII Div. 1 (design basis), EN 13445 (structural integrity reference), and ISO 14001/ISO 9001 manufacturing processes |
| Brand | Ahkemi |
|---|---|
| Origin | Anhui, China |
| Model | MSC100 |
| Vessel Capacity Options | 25 mL, 50 mL, 100 mL |
| Construction Material | Stainless Steel (316L grade typical for high-pressure reactors) |
| Maximum Operating Pressure | 207 bar |
| Vacuum Capability | Up to 207 bar (gauge, indicating pressure-rated design, not vacuum level) |
| Control Interface | 10-inch capacitive touchscreen with real-time multi-parameter display |
| Independent Control | Six fully autonomous reaction stations |
| Data Export | USB port for CSV log export (temperature, stirring speed, internal pressure, time-stamped) |
| Safety Features | Overtemperature cutoff, overpressure audible alarm, integrated leak-tight sealing (tongue-and-groove flange with metal gasket) |
| Form Factor | Dual-row, three-column compact layout (fits standard fume hood footprint, ~600 × 450 × 400 mm H) |
| Compliance Context | Designed for GLP-compliant lab environments |
| Brand | Ahkemi |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MSD2L-SS1-L1G2 |
| Reactor Type | High-Pressure Batch Reactor |
| Vessel Volume Options | 300 mL, 2 L, 5 L, 10 L |
| Design Pressure | 10 MPa |
| Design Temperature | 300 °C |
| Construction Material | Stainless Steel (SS316L standard) |
| Stirring Mechanism | Magnetic Coupling Drive with Propeller or Anchor Impeller (Single- or Dual-Stage) |
| Gas Inlet Control | Constant-Flow or Constant-Pressure Mode |
| Liquid Dosing | Anhydrous/Oxygen-Free Injection via Septum or Valve-Isolated Port |
| Vacuum Capability | ≤10⁻³ mbar (with optional vacuum pump interface) |
| Pressure Monitoring | WIKA Bourdon Tube Gauge + MEAS 4–20 mA Pressure Transmitter |
| Temperature Monitoring | Dual Pt100 RTD Sensors (Jacket & Internal) |
| Heating Method | Electric Cartridge Heaters or External Oil Circulator Interface |
| Safety Systems | Rupture Disk + Spring-Loaded Safety Valve + Redundant Interlock Logic (Temperature/Pressure/Combustible Gas Detection) |
| Data Acquisition | 10.2″ HMI Touchscreen with Local Historian |
| Sampling | Integrated Quenchable Liquid Sampling Loop with Cryo-Trap and Inert Gas Purge |
| Brand | Ahkemi |
|---|---|
| Origin | Anhui, China |
| Model | MSG |
| Vessel Capacity | 25 mL, 50 mL, 100 mL, 300 mL, 500 mL, 1000 mL |
| Design Temperature | 550 °C (Standard Heating up to 300 °C) |
| Design Pressure | 35 MPa (Optional), Standard: 20 MPa (for 25–100 mL), 10 MPa (for 300–1000 mL) |
| Construction Material | 316L Stainless Steel or Hastelloy C-276 (Optional) |
| Stirring Speed Range | 100–1200 rpm (100–600 rpm above 350 °C) |
| Heating Method | Embedded Stainless Steel Heating Module |
| Heating Power | 1 kW |
| Control Interface | 7-inch Resistive Touchscreen Display |
| Safety Systems | FITOK Inlet/Outlet Needle Valves, FITOK Safety Valve, Custom Burst Disc, Over-Temperature Cut-off, Over-Pressure Audible Alarm |
| Vacuum Capability | ≤ 35 MPa (gauge, as pressure rating implies full vacuum compatibility) |
| Power Supply | 200–240 V AC, 50–60 Hz |
| Dimensions (Reactor Unit) | Approx. 250 × 460 × 410 mm (L × W × H) |
| Brand | Ahkemi |
|---|---|
| Origin | Anhui, China |
| Model | MSI |
| Vessel Capacity | 25–1000 mL |
| Design Pressure | 35 MPa (optional), Standard: 10–20 MPa |
| Design Temperature | 550 °C |
| Heating Method | Embedded Stainless Steel Heating Module (1 kW) |
| Stirring Speed | 100–1200 rpm (100–600 rpm above 350 °C) |
| Stirring Mechanism | High-Torque Magnetic Coupling Drive |
| Construction Material | 316L Stainless Steel or Hastelloy C-276 (optional) |
| Vacuum/Pressure Rating | Up to 35 MPa |
| Safety Systems | MEAS Pressure Transducer + Ashcroft Pressure Gauge + Swagelok Needle Valves + FITOK Safety Relief Valve + Custom Burst Disc |
| Control Interface | 7-inch Resistive Touchscreen Display |
| Data Export | USB 2.0 Interface |
| Power Supply | 200–240 V AC, 50–60 Hz |
| Dimensions (Reactor Body) | ~250 × 300 × 410 mm |
| Controller Dimensions (for 100 mL unit) | 260 × 470 × 260 mm |
| Brand | Ahkemi |
|---|---|
| Origin | Anhui, China |
| Model | MSP |
| Reactor Volume Options | 25 mL, 50 mL, 100 mL, 300 mL, 500 mL, 1000 mL |
| Construction Material | Stainless Steel (316L standard) |
| Maximum Operating Pressure | 345 bar (5000 psi) |
| Sealing System | Dual-seal configuration — reinforced PTFE gaskets ≤300 °C |
| Vacuum Capability | Up to −0.098 MPa (equivalent to ~20 mbar abs) |
| Heating Method | Integrated steel-sheathed resistive furnace with overheat protection |
| Control Architecture | Siemens S7-1200 PLC + Schneider safety relays |
| Temperature Control Precision | ±1 °C (typical, full range) |
| Stirring Drive | Patented high-torque magnetic coupling, fully static seal |
| Compliance | Designed per ISO 4775, ASME BPVC Section VIII Div. 1 (for rated pressure variants), CE-marked for laboratory equipment |
| Brand | Ahkemi |
|---|---|
| Origin | Anhui, China |
| Model | NS6-20D |
| Vessel Capacity | 10 mL & 20 mL per station |
| Construction Material | Stainless Steel (316L grade typical) |
| Maximum Operating Pressure | 103 bar |
| Vacuum Capability | Up to 10⁻³ mbar (note: “103bar” in source is a typographical error |
| Control Interface | 7-inch HD capacitive touchscreen |
| Data Export | USB port for CSV log export (temperature, stirring speed, time stamps) |
| Heating Method | Integrated electric heating mantle with PID control |
| Stirring Mechanism | Internal magnetic coupling drive per vessel |
| Vessel Configuration | Monolithic six-reactor block with independent sealing and pressure containment |
| Opening Mechanism | Quick-release clamp-style flange with torque-indicating fasteners |
| Compliance | Designed per ASME BPVC Section VIII Div. 1 guidelines for Class I pressure equipment (consult local regulatory interpretation) |
| Brand | Ahkemi |
|---|---|
| Origin | Anhui, China |
| Model | NSI |
| Vessel Capacity | 10–1000 mL |
| Design Pressure | 35 MPa |
| Design Temperature | 500 °C |
| Construction Material | 316L Stainless Steel (standard), Hastelloy C-276 (optional) |
| Heating Method | Embedded stainless steel heating module |
| Stirring Speed Range | 100–1200 rpm |
| Control Interface | 7-inch capacitive touchscreen |
| Data Export | USB port |
| Safety Systems | MEAS pressure transducer, Ashcroft analog pressure gauge, Swagelok inlet/outlet needle valves, FITOK safety relief valve, custom rupture disc, over-temperature cut-off, over-pressure audible alarm |
| Brand | Ahkemi |
|---|---|
| Origin | Anhui, China |
| Model | NSP50 |
| Vessel Capacity | 10–1000 mL (standard options: 25, 50, 100, 300, 500, 1000 mL) |
| Design Temperature | 500 °C |
| Design Pressure | 35 MPa (345 bar) |
| Standard Pressure Rating | 20 MPa (25–100 mL), 10 MPa (300–1000 mL) |
| Construction Material | 316L stainless steel (standard), Hastelloy C-276 (optional) |
| Sealing System | Tongue-and-groove flange with reinforced PTFE gasket (rated to 300 °C), fully welded-free monolithic body |
| Stirring Mechanism | Brushless DC motor + high-coercivity magnetic coupling |
| Stirring Speed Range | 100–1200 rpm |
| Heating Method | Integrated stainless-steel cartridge heater (1 kW) |
| Control Interface | 7-inch capacitive touchscreen + USB data export + optional remote operation via Ahkemi ReactorCloud™ mobile app and web portal |
| Safety Systems | MEAS pressure transducer, Ashcroft analog pressure gauge, Swagelok safety relief valve, custom rupture disc, overtemperature cutoff, real-time audible overpressure alarm |
| Compliance | Designed per ASME BPVC Section VIII Div. 1 guidelines for laboratory-scale pressure vessels |
| Brand | Ahkemi |
|---|---|
| Origin | Anhui, China |
| Model | NVG (General), NVI (Intelligent), NVP (Remote-Controlled) |
| Vessel Capacity | 25–500 mL |
| Maximum Operating Pressure | 10 MPa |
| Maximum Operating Temperature | 300 °C |
| Construction Material | SS316L (standard), optional Hastelloy C-276, TA2, Zr702 |
| Stirring Speed Range | 100–1200 rpm |
| Heating Method | Integrated stainless steel heating module (1 kW) |
| Optical Window | Sapphire crystal (26 mm dia. for 25–50 mL |
| Sealing System | Radial + axial dual-seal with Kalrez® perfluoroelastomer O-rings |
| Pressure Monitoring | MEAS sensor (NVI/NVP), digital pressure gauge (ASHCROFT/Fitok) |
| Safety Features | Rupture disc, safety valve (Fitok), overpressure audible alarm (NVI/NVP) |
| Remote Interface | NVP supports local touchscreen, PC-based control, and mobile app via secure IoT protocol |
| Compliance | Designed for GLP-compliant photochemical synthesis workflows |
| Brand | Ahkemi |
|---|---|
| Origin | Anhui, China |
| Model | SCH-PCRS-8-427-K |
| Cooling Capacity | 130–445 W |
| Heating Method | Ceramic Fan Heater |
| Cooling Method | DC Inverter Compressor (R134a) |
| Temperature Control Range | 10–50 °C |
| Temperature Stability | ±0.2 °C |
| Stirring Mode | Direct-Drive Rare-Earth Permanent Magnet Motor |
| Stirring Speed | 150–1000 rpm, Continuously Adjustable |
| Light Source Interface | 24 V / 8 A DC Output |
| Standard Reaction Stations | 12 (3 × 4 configuration) |
| Dimensions (W×D×H) | 420 × 470 × 550 mm |
| Brand | Ahkemi |
|---|---|
| Origin | Anhui, China |
| Model | SCI-PCRS-3-455-K |
| Cooling Capacity | 130–445 W |
| Refrigeration Power Consumption | 70–220 W |
| Temperature Control Range | 10–50 °C |
| Temperature Control Accuracy | ±0.2 °C |
| Stirring Speed | 150–1000 rpm (stepless) |
| LED Power Supply Interface | 24 V / 8 A |
| Standard Sample Capacity | 12 parallel reactors |
| Dimensions (W×D×H) | 500 × 470 × 570 mm |
| Refrigerant | R134a |
| Heating Method | Ceramic fan-heater |
| Cooling Method | DC inverter-driven compressor with finned heat exchanger |
| Brand | Ahkemi |
|---|---|
| Origin | Anhui, China |
| Model | TFD-1100-70-RZ |
| Max Temperature | 1100 °C |
| Rated Temperature | 1000 °C |
| Temperature Control Accuracy | ±1 °C |
| Heating Rate (to max temp) | ≤10 °C/min |
| Heating Method | Resistive Wire Heating |
| Internal Dimensions | 800 × 500 × 1550 mm |
| Tube Dimensions | φ70 × φ50 × 350 mm (customizable) |
| Heating Zone Length | 220 mm |
| Rated Power | 3.5 kW |
| Dual-Zone Variant Power | 4.5 kW |
| Dual-Zone Heating Length | 2 × 200 mm |
| Gas Flow Control | Two Mass Flow Controllers (N₂ & CO₂, 0–2 SLM each) |
| Balance Range | 0–220 g |
| Balance Readability | 0.1 mg |
| Cooling | Dual-layer forced-air cooling |
| Surface Temperature | ≤60 °C |
| Temperature Programming | 30-segment programmable controller (Yudian PID with K-type thermocouple) |
| Brand | Ahkemi |
|---|---|
| Origin | Anhui, China |
| Model | TFG-1200-50-I-220 |
| Instrument Type | Vertical Tube Furnace |
| Max Temperature | 1100 °C |
| Temperature Control Accuracy | ±1 °C |
| Max Power | 2.0 kW |
| Heating Rate (to Max Temp) | ≤10 °C/min |
| Heating Method | Resistance Wire |
| Internal Chamber Dimensions | 660 × 320 × 580 mm |
| Tube ID × Length | 50 × 450 mm |
| Sample Boat Capacity | 10 mL (customizable) |
| Sample Boat Diameter | 30 mm |
| Heated Zone Length | 220 mm |
| Mass Flow Range (Rotameter) | 30–200 mL/min (customizable) |
| Control System | Dual-Channel Intelligent Programmable Controller with Color Touchscreen |
| Power Supply | AC 220 V, 50/60 Hz |
| Weight | 35 kg |