Common Laboratory Equipment
Filter
Showing 2431–2460 of 5364 results
| Brand | EYELA (Tokyo Rikakikai Co., Ltd.) |
|---|---|
| Origin | Japan |
| Model | CA |
| Cooling Capacity | 1200 W (1030 kcal/h) at 10°C bath temperature |
| Temperature Range | −20 to +30°C |
| Temperature Stability | ±2°C |
| Circulation Flow Rate | 16 L/min (max), 27 L/min (external pump option) |
| Max Head | 9.5 m |
| Reservoir Volume | 14 L (16.5 L total) |
| Refrigerant | R407C |
| Compressor Power | 675 W (air-cooled) |
| Reservoir Material | SUS304 stainless steel |
| Cooling Coil Material | Nickel-plated copper |
| External Port Fitting | 11 mm OD tubing |
| Dimensions (W×D×H) | 340 × 384 × 851 mm |
| Weight | 41 kg |
| Control Interface | Touch-key input with LCD display (0.1°C resolution) |
| Safety Features | Leakage/overcurrent protection, high-pressure switch, overload relay, compressor protection timer, 2 A fuse for peripheral sockets, self-diagnostic thermostat, circulation pump thermal protector |
| I/O Ports | Recorder output, alarm output |
| Certifications | Complies with JIS B 8603, CE-marked per EN 61000-6-3 & EN 61000-6-2 |
| Brand | EYELA |
|---|---|
| Origin | Japan |
| Model | CA-1116A |
| Temperature Range | −20 to 30 °C (without heater) |
| Temperature Stability | ±2 °C |
| Cooling Capacity | 1100 W at 10 °C, 840 W at 0 °C, 510 W at −10 °C |
| Max. Flow Rate | 12 L/min |
| Max. Head | 9.5 m |
| Reservoir Volume | ~16.5 L (Ø280 × H270 mm) |
| Reservoir Material | SUS304 Stainless Steel |
| Refrigerant | R407C (HFC blend) |
| Compressor Control | ON/OFF |
| Temperature Display | LED digital, 1 °C resolution |
| Safety Features | Leakage/overcurrent protection, high-pressure compressor switch, compressor protection timer, self-diagnostic thermostat, pump auto-protection |
| Power Supply | AC 220 V, 50 Hz, 1.1 kVA, 5.5 A |
| Ambient Operating Temperature | 5–35 °C |
| Dimensions (W×D×H) | 354 × 384 × 851 mm (excl. water nozzles) |
| Net Weight | 41 kg |
| Cooling Method | Air-cooled |
| Brand | EYELA (Tokyo Rikakikai Co., Ltd.) |
|---|---|
| Origin | Japan |
| Model | CA-1310 |
| Cooling Capacity | 1200 W (1030 kcal/h) at 10°C liquid temperature |
| Temperature Range | −20 to +20°C |
| Temperature Stability | ±2°C |
| External Flow Rate | Up to 16 L/min |
| Max. Head | 9.5 m |
| Reservoir Volume | 13 L (usable liquid volume: 10.5 L) |
| Refrigerant | R407C |
| Compressor Control | ON-OFF |
| Display Resolution | 0.1°C |
| Power Supply | Air-cooled, 675 W |
| Tank Material | SUS304 stainless steel |
| Dimensions (W×D×H) | 460 × 430 × 570 mm |
| Weight | ~44 kg |
| Brand | EYELA (Tokyo Rikakikai Co., Ltd.) |
|---|---|
| Origin | Japan |
| Model | CA-1320 |
| Cooling Capacity | 1050 W (903 kcal/h) at 10°C liquid temperature |
| Temperature Range | −20 to +20°C |
| Temperature Stability | ±2°C |
| Circulation Flow Rate | Up to 16 L/min |
| Max. Head | 9.5 m |
| Reservoir Volume | 13 L (usable liquid volume: 10.5 L) |
| Refrigerant | R407C |
| Compressor Control | ON-OFF |
| Display Resolution | 0.1°C |
| Reservoir Material | SUS304 stainless steel |
| Dimensions (W×D×H) | 460 × 430 × 570 mm |
| Weight | ~48 kg |
| Cooling Method | Air-cooled |
| Power Consumption | 675 W |
| Brand | EYELA (Tokyo Rikakikai Co., Ltd.) |
|---|---|
| Origin | Japan |
| Model | CCA |
| Cooling Capacity | 450 W (387 kcal/h) at 10°C liquid temperature |
| Temperature Range | –20°C to +20°C |
| Temperature Stability | ±2°C |
| Circulation Flow Rate | Up to 9 L/min (external pump: up to 14 L/min) |
| Max Head | 4.2 m |
| Reservoir Volume | ~4 L |
| Reservoir Material | SUS304 stainless steel |
| Cooling Circuit | Closed-loop |
| Refrigerant | R407C |
| Compressor Type | Air-cooled, 350 W output |
| Temperature Control | ON-OFF refrigeration control |
| Display & Input | Touch-key LCD, 0.1°C resolution |
| Safety Features | Leakage/overcurrent protection, compressor overload protection, self-diagnostic system (compressor fault, power failure alarm, sensor error), circulation pump thermal protection |
| I/O Ports | Recorder output, alarm output |
| Cooling Coil Material | Nickel-plated copper |
| Inlet/Outlet Fitting | 11 mm OD compatible |
| Dimensions (W×D×H) | 232 × 497 × 490 mm |
| Weight | ~29 kg |
| Brand | EYELA (Tokyo Rikakikai Co., Ltd.) |
|---|---|
| Origin | Japan |
| Model | CCR-1000G |
| Reactor Type | Flow-through Catalytic Hydrogenation System |
| Max Operating Pressure | 0.4 MPa |
| Temperature Range | Ambient +15°C to 200°C (Aluminum Block Heating Block) |
| Liquid Flow Rate | Up to 0.9 mL/min |
| Gas Flow Rate | Up to 100 mL/min (H₂) |
| Catalyst Cartridge | Stainless Steel Column (Ø5 × 50 mm, replaceable) |
| Wetted Materials | PP (reaction reservoir), Fluoropolymer (fluidic pathways), Perfluoroelastomer (O-rings), SUS316 (glass support components) |
| Power Supply | AC 100 V, 50/60 Hz, 2.5 A, 250 VA |
| Dimensions (W×D×H) | 356 × 461 × 389 mm |
| Safety Features | Pressure-sensor-triggered emergency shutdown, independent overtemperature protection for heating block, heater overload protection, leakage and overcurrent protection, self-diagnostic system, communication failure detection |
| Compliance | Designed for GLP-compliant laboratory environments |
| Brand | EYELA (Tokyo Rikakikai Co., Ltd.) |
|---|---|
| Origin | Japan |
| Model | CCX |
| Temperature Control Range (CCX-1000/1010) | RT + 10°C to 160°C (with external chiller) |
| Temperature Control Range (CCX-1200/1210) | −78°C to RT (using dry ice/acetone or cryogenic circulator) |
| Number of Reaction Vessels | 1–12 |
| Reaction Volume per Vessel | 3–15 mL (max. 25 mL) |
| Stirring Method | High-torque magnetic stirring |
| Stirring Speed | 100–1200 rpm (in water) |
| Temperature Setting & Display | Digital PID controller with membrane keypad input and LED display (CCX-1000/1010) |
| Stirring Speed Control | Rotary knob |
| Reflux Capability | Integrated high-efficiency reflux condenser (CCX-1000/1010) |
| Gas Purging | Vacuum-assisted inert gas (N₂/Ar) exchange via septum-sealed ports |
| Vessel Compatibility | Standard Φ24 × 150 mm glass tubes (straight-mouth and flanged types), PTFE caps, nitrile rubber seals |
| Wetted Materials | Borosilicate glass, PTFE, nitrile rubber |
| External Dimensions (stand only) | 245 W × 275 D × 800 H mm |
| Weight | ~8 kg |
| Brand | EYELA |
|---|---|
| Origin | Japan |
| Model | CCX-3200 |
| Tube Capacity | 1–8 (up to 32 with adapter) |
| Reaction Volume per Tube | 0.5–60 mL |
| Temperature Range | RT +10°C to 280°C (max 200°C at 50–60 mL load) |
| Rotation Speed | ~100–1200 rpm (in water) |
| Heating Method | Electric block heater with PID control |
| Stirring Type | High-strength magnetic stirring |
| Condensation Mode | Optional reflux via coolant-split head and condenser |
| Vessel Compatibility | DURAN® borosilicate glass tubes (Φ12–34 mm, 12 sizes, max height 50 mm) |
| Gas Handling | Compatible with Schlenk lines, sealed tubes, pressure-rated vessels, and Dean-Stark traps |
| Dimensions (W×D×H) | 245 × 275 × 800 mm (stand only) |
| Weight | ~8 kg |
| Compliance | Designed for GLP-compliant synthetic laboratories |
| Brand | EYELA (Tokyo Rikakikai Co., Ltd.) |
|---|---|
| Origin | Japan |
| Model | CCX-3200 |
| Reaction Vessel Capacity | 0.5–60 mL |
| Number of Reaction Positions | 1–8 (up to 32 with optional adapter kits) |
| Temperature Range | Ambient +10°C to 280°C (max 200°C at 50–60 mL load) |
| Stirring Speed | ~100–1200 rpm (in water) |
| Stirring Type | High-strength magnetic coupling |
| Temperature Control | Digital keypad setting & LED display |
| Stirring Control | Analog knob adjustment |
| Reflux Capability | Optional water-cooled split-head condenser |
| Reagent Addition | Via pipettes, droppers, or calibrated dispensers |
| Wetted Materials | DURAN® borosilicate glass |
| Tube Diameter Compatibility | Φ12–34 mm (12 standard sizes), max height 50 mm |
| External Dimensions (W×D×H) | 245 × 275 × 800 mm (stand only) |
| Weight | ~8 kg |
| Brand | EYELA (Tokyo Rikakikai Co., Ltd.) |
|---|---|
| Origin | Japan |
| Model | DDL-1000 / DDL-2000 |
| Reactor Type | Jacketed Laboratory Reactor System |
| Temperature Control Modes | Reaction Mass Control, Jacket Control, Isothermal Mode, Gradient Ramp Mode |
| Stirring | Mechanical Agitation (PTFE or SUS304 Impeller) |
| Temp. Range | 10–80 °C (Jacket) |
| Temp. Stability | ±0.1 °C |
| Stirring Speed | 10–1059 rpm |
| Max. Torque | 19.6 N·m (DDL-1000), 0.49 N·m (DDL-2000) |
| Cooling Rate (Jacket) | up to 30 K/min |
| Heating Rate (Jacket) | up to 7.0 K/min |
| Safety Systems | Independent Over-Temperature Protection, Leakage Current Breaker, Low-Coolant-Level Alarm, Emergency Rapid-Cooling Function, SSR Failure Detection, Dual Temperature Limit Alarms |
| Power Supply | AC 100 V, 50/60 Hz (7 A / 700 VA for DDL-1000 |
| Dimensions & Weight | 290×380×790 mm, 20 kg (DDL-1000) |
| Brand | EYELA (Tokyo Rikakikai Co., Ltd.) |
|---|---|
| Origin | Japan |
| Model | DDS |
| Reactor Capacity | 4 × (50 / 100 / 250 mL, independent) |
| Temperature Control Range | −50 to 250 °C (requires external chiller) |
| Temperature Accuracy | ±0.5 K (−20–100 °C, aluminum block), ±1 K (100–180 °C, aluminum block) |
| Stirring Speed | 125–1000 rpm |
| Max. Heating Rate | Tr < 5.3 K/min, Tj < 19.3 K/min (250 mL water in glass reactor) |
| Max. Cooling Rate | Tr < 7.2 K/min, Tj < 29.6 K/min (250 mL water) |
| Max. Heat Removal Capacity | 0.74–1.1 W/g (200 mL water) |
| Heat Flow Measurement Resolution | 0.1 W, ±5% error (standard conditions) |
| Control Modes | Reactor temperature, aluminum block temperature, gradient, isothermal |
| Control Method | PID heating/cooling + cascade control |
| Liquid Addition | 8-channel volumetric dosing |
| Agitation Type | Propeller stirring |
| Optional pH Control | 0–14, acid/base titration |
| Heat Measurement Principle | Thermal conductivity-based calorimetry with calibration |
| Data Visualization | Real-time & historical trend graphs |
| Safety Systems | Leakage current protection, independent overtemperature cutoff, motor overload protection, software self-diagnosis |
| Flask Ports | Rodaviss 24, NS 14/23 (×3), GL 14 (×1) |
| Vessels | Borosilicate glass, round-bottom, graduated (50 mL or 250 mL) |
| Wetted Materials | Glass, PTFE, PPS, Karlez®, SUS316 |
| Dimensions (W×D×H) | 650 × 490 × 380 mm |
| Weight | ~59 kg |
| Power Supply | AC 100 V, 50 Hz, 2000 VA, 20 A |
| Brand | EYELA |
|---|---|
| Origin | Japan |
| Model | FDL-1000 / FDL-2000 |
| Cold Trap Temperature | −45 °C (FDL-1000) / −80 °C (FDL-2000) |
| Ice Capacity | 4 L/24 h (FDL-1000) / 3 L/24 h (FDL-2000) |
| Cold Trap Dimensions | Ø200 × 300 mm, SUS304 |
| Vacuum Gauge | Pirani gauge, 0.0–533 Pa (digital display) |
| Refrigeration System | FDL-1000 — 600 W, R404A |
| Vacuum Pump Interface | Optional, 100/120 L/min (50/60 Hz) |
| Display | 3.4-inch TFT LCD with membrane keypad |
| Power Supply | Dedicated socket for freeze-drying chamber (max. 3 A) |
| External Dimensions (W×D×H) | 700 × 550 × 955 mm |
| Net Weight | ~116 kg (FDL-1000) / ~144 kg (FDL-2000) |
| Safety Features | Leakage current protection, overcurrent protection, compressor protection circuit, service outlet fuse, self-diagnostic control panel, automatic venting upon vacuum release |
| Optional Accessories | Ice mass sensor, data logging output (analog), 0.2 µm inlet filter, defrost function, power recovery timer |
| Brand | EYELA |
|---|---|
| Origin | Japan |
| Model | FDM-1000 |
| Cold Trap Temperature | −45 °C |
| Condensation Capacity | 1 L/24 h |
| Display | 3.4″ LCD (button-operated) |
| Vacuum Gauge | Digital Pirani gauge (0.0–533 Pa) |
| Cold Trap Dimensions | Ø200 × 175 H mm (SUS304) |
| Refrigeration System | Air-cooled compressor (450 W, R507A) |
| Vacuum Pump Interface | Dedicated socket (max. 6 A), compatible with ≥50 L/min pumps |
| Power Supply | 7 A total (230 V AC, 50/60 Hz) |
| External Dimensions & Weight | 450 W × 420 D × 460 H mm / ≈38 kg |
| Safety Features | Leakage and overcurrent protection, compressor protection circuit, panel self-diagnostic function, vacuum release valve (0.2 µm filter), hot-gas defrost, power-fail recovery logic |
| Optional Functions | Vacuum pump auto-start/stop, real-time vacuum & cold trap temperature monitoring, elapsed time counter (vacuum pump runtime), automatic end-of-drying detection, vacuum auto-bleed post-cycle |
| Brand | EYELA |
|---|---|
| Origin | Japan |
| Model | FDM-2010 |
| Cold Trap Temperature | −80 °C |
| Condensation Capacity | 1 L/24 h |
| Display | 3.4-inch LCD |
| Vacuum Gauge | Digital Pirani gauge (0.0–533 Pa) |
| Cold Trap Dimensions | Ø153 × 225 H mm, SUS304 |
| Refrigeration System | Dual 500 W compressors, HFC blend (R290/R170) |
| Vacuum Pump Interface | Dedicated 125 V/6 A outlet (pump not included |
| Freeze Drying Chamber Interface | Dedicated 125 V/2 A outlet |
| Overall Dimensions | 450 W × 550 D × 945 H mm |
| Net Weight | ~81 kg |
| Safety | Leakage current protection, overcurrent cutoff, compressor thermal protection, self-diagnostic control panel, vacuum release valve with 0.2 µm particulate filter, hot-gas defrost system |
| Functions | Auto-vacuum start/stop, vacuum & cold trap temperature monitoring, elapsed time logging (for pump runtime and sublimation duration), power-failure recovery, automatic vacuum break post-cycle |
| Brand | EYELA (Tokyo Rikakikai Co., Ltd.) |
|---|---|
| Origin | Japan |
| Model | FDU-2110 |
| Cold Trap Temperature | −80 °C |
| Condensation Capacity | 3 L per 24 h |
| Vacuum Range | 0.4–533 Pa (Pirani gauge, digital display) |
| Cold Trap Dimensions | Φ200 × 300 mm (SUS304 stainless steel) |
| Refrigeration System | 500 W dual-stage compressor, R404A/R23 refrigerant blend |
| Defrost Method | Hot-gas auto-defrost with thermal cutoff |
| Vacuum Release | Motorized solenoid valve with 0.2 µm sterile air filter |
| Power Supply | Vacuum pump circuit — max. 6 A |
| Overall Dimensions & Weight | 700 × 550 × 935 mm (W×D×H), approx. 140 kg |
| Safety Features | Leakage/overcurrent protection, compressor protection circuit, control panel self-diagnosis, fuse for service outlet |
| Brand | EYELA |
|---|---|
| Origin | Japan |
| Model | MF-1000 |
| Rotation Speed Range | 100–1200 rpm |
| Max. Evaporation Rate | 760 mL/h (water) |
| Ultimate Vacuum | ≤399.9 Pa (≤3 mmHg) |
| Condenser Type | Vertical double-coil |
| Collection Flask | 1 L spherical flask (S35/20) |
| Condenser & Vacuum Interface | Quick-connect, OD 10 mm × 2 each |
| Wetted Materials | Borosilicate glass, SUS 304 stainless steel, PTFE |
| Dimensions (W×D×H) | 490 × 350 × 930 mm |
| Weight | 17 kg |
| Power Supply | AC 100 V, 50/60 Hz, 2 A, 200 VA |
| Drive Motor | Brushless DC motor |
| Shaft Sealing | Magnetic coupling |
| Bearing | Ceramic lower bearing |
| Stirring Element | Removable PTFE-coated blade with smooth, non-porous surface |
| Brand | EYELA (Tokyo Rikakikai Co., Ltd.) |
|---|---|
| Origin | Japan |
| Model | MF/F |
| Drive Type | DC brushless motor with 6-point rotor coupling |
| Heating Method | Steam or recirculating water bath |
| Vacuum Operation Range | Down to 1.33 Pa (10 mTorr) |
| Evaporation Area | 0.04–0.25 m² (glass or SUS316L evaporator sleeves) |
| Condenser Surface Area | 0.3–3.0 m² (multi-layer coiled or triple-coil design) |
| Collection Flask Capacity | 1–20 L (evaporate + concentrate) |
| Max. Feed Viscosity | 1.0–1.5 Pa·s (1000–1500 cP) |
| Rotational Speed Range | 140–1800 rpm (infinitely variable, 50/60 Hz) |
| Evaporation Rate | Up to 40 L/h (steam-heated, F-200 model) |
| Sealing System | Magnetic drive shaft (F-70/F-150), mechanical seal (F-200), vacuum-rated elastomer gasket (MF-10A) |
| Brand | EYELA (Tokyo Rikakikai Co., Ltd.) |
|---|---|
| Origin | Japan |
| Model | MGS |
| Temperature Range | Ambient +5°C to 200°C |
| Temperature Accuracy | ±0.1–0.2°C |
| Control System | Microcomputer-based P.I.D. temperature control |
| Display Resolution | 0.1°C (digital LED) |
| Heating Block | Single aluminum block (90W × 125D × 70H mm), SUS304 stainless steel sample tubes (1.6 mm ID × 180 mm length) |
| Gas Filtration | Integrated 0.2 µm hydrophobic filter |
| Gas Flow Regulation | Adjustable needle valve (9 mm OD inlet connection) |
| Safety Features | Dual-limit temperature alarm, power failure detection, heater runaway protection, independent over-temperature cutoff, Pt100Ω sensor monitoring, fuse protection |
| Programmability | Two-stage program control, auto-start/stop, auto-tuning, temperature display calibration |
| Operating Ambient | 5–35°C |
| Dimensions & Weight | 240W × 310D × 600H mm, 7.5 kg |
| Brand | EYELA |
|---|---|
| Origin | Japan |
| Model | N-1100S / N-1100SF |
| Rotation Speed | 20–180 rpm |
| Max. Evaporation Rate | 25 mL/min (water) |
| Ultimate Vacuum | <399.9 Pa (3 mmHg) |
| Bath Temperature Range | RT+5°C to 90°C (N-1100S-W / N-1100SD) or RT+5°C to 180°C (N-1100S-WD) |
| Temp. Control Accuracy | ±1.5°C (water bath, rotating flask) / ±3.0°C (oil bath, rotating flask) |
| Heating Power | 1 kW |
| Condenser | Inclined double-layer coiled tube, cooling area: 0.146 m² |
| Flask Capacity | 1 L pear-shaped (ISO NS29/38) or 500 mL pear-shaped (transparent joint, NS29/38) |
| Receiver | 1 L spherical (ISO S35/20) |
| Shaft Dimensions | ID 18 mm × L 272 mm, TS29/38 |
| Vacuum Seal | Dual-material PTFE/Viton gasket |
| Air Filter | 0.2 µm disk filter (N-1100SD/SFD only) |
| Lift Travel | 100 mm (counterbalanced slide) + 150 mm (manual extension) |
| Bath Dimensions & Capacity | Ø230×100H mm (3 L, water-only) or Ø240×120H mm (5 L, water/oil) |
| Brand | EYELA (Tokyo Rikakikai) |
|---|---|
| Origin | Japan |
| Model | N-1100V-W/WD |
| Evaporation Capacity | Max. 25 mL/min |
| Rotational Speed | 20–180 rpm |
| Ultimate Vacuum | < 399.9 Pa |
| Bath Temperature Range | Room Temp +5°C to 90°C |
| Heating Control Accuracy | ±0.5°C (typical for PID-controlled water/oil bath) |
| Cooling Surface Area | 0.146 m² |
| Evaporating Flask Capacity | 3 L |
| Brand | EYELA (Tokyo Rikakikai Co., Ltd.) |
|---|---|
| Origin | Japan |
| Model | N-1200AV / N-1200AVF-W / N-1200AVF-WD |
| Rotational Speed | 5–280 rpm |
| Max. Evaporation Rate | 25 mL/min |
| Ultimate Vacuum | < 399.9 Pa (≤ 3 mmHg) |
| Water Bath Temp. Range | RT + 5°C to 90°C |
| Oil/Water Dual Bath Temp. Range | RT + 5°C to 180°C |
| Temp. Control Accuracy | ±1.5°C (water) / ±3°C (oil) |
| Temperature Control Method | Microcomputer-based ON-OFF control |
| Heating Power | 1.05 kW |
| Condenser Type | Vertical double-coil |
| Cooling Surface Area | 0.146 m² |
| Flask Capacity | Standard 1 L (up to 3 L compatible) |
| Bath Dimensions & Volume | Ø240 × 120 mm (shallow zone Ø160 mm), ~5.4 L |
| Lift Stroke | 100 mm (manual rack) + 130 mm (handle extension) |
| Overall Dimensions & Weight | 595 W × 445 D × 700 H mm, 16.5 kg |
| Safety Features | Thermal fuse, dry-run prevention sensor |
| Sealing Material | PTFE vacuum seal |
| Condenser & Flask Joints | Standard taper 29/38 (flask), S35/20 (receiving flask) |
| Shaft | Short-type glass rotary shaft, ID 18 mm × L 178 mm |
| Quick-Connect Fitting | Integrated push-fit interface for chiller hose coupling |
| Brand | EYELA |
|---|---|
| Origin | Japan |
| Model | N-1210BS-WB |
| Capacity | 5.4 L |
| Ultimate Vacuum | 10 hPa (≈7.5 Torr) |
| Rotation Speed | 5–280 rpm |
| Bath Temperature Range | Ambient to 180 °C (±1.5 °C for water, ±3 °C for oil) |
| Evaporation Rate | Max. 25 mL/min (water) |
| Condenser Cooling Area | 0.146 m² |
| Bath Dimensions | Ø240 × 120 mm (H) |
| Power | 1.2 kVA |
| Weight | 18 kg |
| Electrical Supply | AC 220 V, 50 Hz |
| Brand | EYELA |
|---|---|
| Origin | Japan |
| Model | N-1210BS-WB |
| Bath Temperature Range | Room Temp. to 180 °C (±1.5 °C in water, ±3 °C in oil) |
| Rotational Speed Range | 5–280 rpm |
| Evaporation Rate (Water) | Up to 25 mL/min |
| Bath Capacity | ~5.4 L |
| Bath Dimensions (ID) | 240 mm × 120 mm H |
| Bath Material | Aluminum with PTFE Coating |
| Heating Power | 1 kW |
| Vertical Travel | Motorized lift 110 mm + manual extension 130 mm |
| Condenser Type | Tilted dual-spiral coil |
| Flask Capacity | 1–3 L (evaporating), 1 L (receiving) |
| Vacuum Seal | PTFE sealing gasket |
| Cooling Water Inlet/Outlet | Ø10 mm |
| Power Supply | AC 220 V, 5.5 A, 1.2 kVA, 50 Hz |
| Operating Ambient | 5–35 °C |
| Dimensions (W×D×H) | 729 × 433 × 520 mm (750 mm with lift extended) |
| Weight | 18 kg |
| Brand | EYELA |
|---|---|
| Origin | Japan |
| Model | N-1300D |
| Rotational Speed | 10–310 rpm |
| Bath Temperature Range | RT+5°C to 90°C (water) / RT+5°C to 180°C (oil) |
| Temperature Accuracy | ±1.5°C (water), ±3°C (oil) |
| Max. Evaporation Rate | 25 mL/min (water) |
| Ultimate Vacuum | ≤399.9 Pa (≤3 mmHg) |
| Condenser Surface Area | 0.146 m² |
| Lift Stroke | 180 mm (manual, stepless) |
| Motor | Brushless DC |
| Cooling Water Inlet/Outlet | Ø10 mm |
| Power Input | AC 220 V, 50 Hz, 6.5 A, 1.43 kVA |
| Dimensions (W×D×H) | 578×352×645 mm (N-1300D-W) / 565×352×645 mm (N-1300D-WB) |
| Weight | 12.7 kg (N-1300D-W) / 13.3 kg (N-1300D-WB) |
| Bath Capacity | 4.3 L (SB-1300, stainless steel SUS304) / 5.4 L (OSB-2200, aluminum with PTFE coating) |
| Sealing | Dual-layer PTFE/Viton vacuum seal |
| Brand | EYELA |
|---|---|
| Origin | Japan |
| Model | N-1300S |
| Rotational Speed | 10–310 rpm |
| Bath Temperature Range | RT+5°C to 90°C (water) / RT+5°C to 180°C (oil) |
| Temperature Accuracy | ±1.5°C (water), ±3°C (oil) |
| Max. Evaporation Rate | 25 mL/min (water) |
| Ultimate Vacuum | ≤399.9 Pa (≤3 mmHg) |
| Condenser Surface Area | 0.146 m² |
| Lift Stroke | 180 mm (manual, stepless) |
| Motor | Brushless DC |
| Cooling Water Inlet/Outlet | Ø10 mm |
| Power Supply | AC 220 V, 50 Hz, 6.5 A, 1.43 kVA |
| Dimensions (W×D×H) | 736×352×504 mm (N-1300S-W) / 724×352×504 mm (N-1300S-WB) |
| Weight | 12.1 kg (N-1300S-W) / 12.7 kg (N-1300S-WB) |
| Bath Capacity | 4.3 L (SB-1300, stainless steel SUS304) / 5.4 L (OSB-2200, aluminum with PTFE coating) |
| Sealing | Dual-layer PTFE/Viton vacuum seal |
| Brand | EYELA |
|---|---|
| Origin | Japan |
| Model | N-1300V |
| Rotational Speed | 10–310 rpm |
| Bath Temperature Range | RT+5°C to 90°C (water) / RT+5°C to 180°C (oil) |
| Temperature Accuracy | ±1.5°C (water), ±3°C (oil) |
| Max. Evaporation Rate | 25 mL/min (water) |
| Ultimate Vacuum | ≤399.9 Pa (≤3 mmHg) |
| Condenser Surface Area | 0.146 m² |
| Lift Stroke | 180 mm (manual, stepless) |
| Power Input | AC 220 V, 50 Hz, 6.5 A, 1.43 kVA |
| Heating Power | 1.3 kW |
| Bath Dimensions (SB-1300) | Ø220 × 120 mm H, ~4.3 L (SUS304) |
| Bath Dimensions (OSB-2200) | Ø240 × 120 mm H, ~5.4 L (aluminum with PTFE coating) |
| Weight | 12.8 kg (N-1300V-W) / 13.4 kg (N-1300V-WB) |
| Overall Dimensions | 543 × 352 × 823 mm (W×D×H) |
| Cooling Water Inlet/Outlet | Ø10 mm |
| Sealing Material | Dual-layer PTFE/Viton vacuum seal |
| Brand | EYELA (Tokyo Rikakikai Co., Ltd.) |
|---|---|
| Origin | Japan |
| Model | N-2100 |
| Bath Temperature Range | Room Temp +5 to 90°C |
| Bath Temp Control Accuracy | ±1°C |
| Rotation Speed | 5–160 rpm |
| Max Evaporation Rate | 43 mL/min (F-type), 23 mL/min (U/R-type) |
| Ultimate Vacuum | 399.9 Pa |
| Condenser Surface Area | 0.25 m² |
| Lift Stroke | 160 mm |
| Bath Dimensions & Capacity | Ø280 × 144 mm, ~8.5 L |
| Flask Capacity | 5 L (round-bottom), 3 L (receiving flask) |
| Joint Standard | S35/20 spherical ground glass |
| Weight | ~29 kg |
| Brand | EYELA |
|---|---|
| Origin | Japan |
| Model | N-3100 |
| Rotational Speed Range | 10–140 rpm |
| Max. Evaporation Rate | 3.5 L/h (water) |
| Ultimate Vacuum | 2.6 hPa |
| Bath Temperature Range | Ambient +10°C to 180°C (±1°C in water, ±3°C in oil) |
| Heating Power | 3.5 kW |
| Temperature Control | PID |
| Vacuum Control Modes | Setpoint, Auto, Program, Pressure-Step |
| Bath Dimensions & Capacity | Φ360 × 200 mm, ~20 L |
| Bath Material | SUS304 stainless steel |
| Condenser | Vertical triple-coil, 0.5 m² cooling surface |
| Flask Capacity | 10 L spherical (neck Ø100 mm) |
| Collection Flask | 5 L spherical with drain valve |
| Sealing | PTFE mechanical seal |
| Lift Stroke | 145 mm (motorized) |
| Motor | Induction type, 60 W |
| Cooling/Inlet Port Diameter | 16 mm (×2), Solenoid Valve Port: 13 mm |
| Ambient Operating Range | 5–35°C |
| External Dimensions (W×D×H) | 930 × 480 × 1890 mm |
| Weight | ~96 kg |
| Power Supply | AC 200 V, 19 A, 3.8 kVA |
| Brand | EYELA (Tokyo Rikakikai Co., Ltd.) |
|---|---|
| Origin | Japan |
| Model | PPS-1511 / PPS-2511 / PPS-3511 |
| Reaction Vessels | 1–5 units (independently controlled) |
| Synthesis Volume | 1–4 mL (PPS-1511), 10–30 mL (PPS-2511), 50–60 mL (PPS-3511) |
| Temperature Range | −23 to 160 °C (PPS-1511), −27 to 160 °C (PPS-2511), −28 to 130 °C (PPS-3511) — each zone independently adjustable |
| Temp. Control Accuracy | ±0.5 °C |
| Stirring Speed | 100–1600 rpm (4 mL water, PPS-1511), 100–1300 rpm (30 mL water, PPS-2511), 100–1100 rpm (60 mL water, PPS-3511) |
| Stirring Input | Rotary knob with digital RPM display (20–2000 rpm) |
| Temp. Input & Display | Membrane keypad with digital display (−40.0 to 160.0 °C) |
| Gas Handling | Vacuum evacuation and inert gas purging (requires optional sealed reaction vessels) |
| Reflux Capability | Integrated high-efficiency reflux condenser |
| Reagent Addition | Syringe, pipette, or standard-taper dropping funnel — all under inert atmosphere |
| Visual Monitoring | Front-access observation slot with integrated LED illumination |
| Safety Systems | Leakage current breaker, thermal fuse, self-diagnostic firmware (including sensor fault detection and user-configurable upper temperature limit), dual-layer protective housing, drip tray, aluminum block presence detection, motor overheat protection |
| Vessel Dimensions (mm) | Φ15×150H (flanged, PPS-1511), Φ30×200H (flanged, PPS-2511), Φ35×200H (flanged, PPS-3511) |
| Stir Bar Sizes (mm) | Φ10×5H (cross-type), Φ20×7H (cross-type), Φ25×8H (cross-type) |
| External Dimensions (W×D×H, mm) / Weight | 465×335×390 / 25 kg (PPS-1511), 465×335×440 / 27 kg (PPS-2511), 465×335×450 / 28 kg (PPS-3511) |
| Brand | EYELA (Tokyo Rikakikai Co., Ltd.) |
|---|---|
| Origin | Japan |
| Model | PPS-1520 / PPS-2520 / PPS-3520 / PPS-6520 |
| Tube Capacity | 1–5 (up to 20 with optional configuration) |
| Reaction Volume Range | 0.5–60 mL |
| Temperature Control Range | −28 °C to +160 °C (5-zone independent control) |
| Temperature Programming | 7-step ramp/hold profiles |
| Stirring | High-torque magnetic stirring (optional independent stirrer per position) |
| Dosing Control | External programmable peristaltic pump interface (dose volume, rate, temp-triggered start/stop, gradient coupling) |
| Display & Interface | LCD touchscreen |
| Data Logging | Real-time USB-exportable CSV/Excel-compatible records (time-stamped temperature, stirring status, dosing events) |
| Safety Enclosure | Dual-layer acrylic shield with anti-condensation design |
| Compliance | Designed for GLP-compliant lab environments |