Empowering Scientific Discovery

Dalian Istar Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYST (Dalian Yist Instrument Co., Ltd.)
OriginLiaoning, China
ModelYST208B-CR810
Measuring Range0.2–10 m (expandable)
Accuracy±1% FS or ±5 mm (whichever is greater)
Resolution1 mm
Ultrasonic Frequency20–50 kHz
Operating Temperature (Sensor)−10°C to +60°C
Enclosure RatingSensor IP68, Main Unit IP65
Output Signals4–20 mA analog, RS485 digital
Power Supply220 V AC or 24 V DC
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYST (Dalian Yist)
OriginLiaoning, China
ModelYST308B-MS880T
Measurement Range0–500 / 0–1000 / 0–5000 mg/L (field-selectable)
Operating Temperature0–50 °C
Relative Humidity≤90% RH (non-condensing)
Output Signals4–20 mA analog, RS485 digital
Power SupplyAC 220 V ±10% @ 50/60 Hz or DC 24 V ±10%
InstallationSubmersible
Probe IP RatingIP68
Enclosure IP RatingIP65
ComplianceDesigned for continuous in-situ SS monitoring per ISO 7027 (turbidity correlation), ASTM D3977, and EPA Method 160.1 principles
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYST (Dalian Yist Instruments)
OriginLiaoning, China
ModelYST308B-MS880T
Measurement PrincipleDual-beam infrared light scattering (ISO 7027 compliant)
Range0.01–20,000 mg/L (standard)
Resolution0.01–1 mg/L (scale-dependent)
Accuracy±5% of reading (subject to sludge homogeneity)
Repeatability±2%
Operating Temperature0–45 °C
Storage Temperature−15–50 °C
Enclosure RatingIP68 / NEMA 6P
Output InterfaceRS485 / Modbus RTU
Housing MaterialSUS316L stainless steel body
Optional FeatureMotorized brush cleaning system
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYST (Dalian Yist)
OriginLiaoning, China
ModelYST308B-MS880T
Measurement Range0–50 g/L (expandable to 0–100 g/L)
Resolution0.01 g/L
Accuracy±1% FS
Sensor Operating Temperature0–60 °C
Host Operating Temperature0–50 °C
Humidity Limit≤90% RH (non-condensing)
Power SupplyAC 220 V ±10%, 50/60 Hz
Sensor IP RatingIP68
Host IP RatingIP65
Response Time (T90)≤10 s
Output Signals4–20 mA (load ≤500 Ω), RS485
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYST (Dalian Yist Instrument Co., Ltd.)
OriginLiaoning, China
ModelYST809B-DO660
Measurement PrincipleFluorescence Quenching (Pt-porphyrin sensor)
Excitation Wavelength470 nm
Emission DetectionPhase-shift analysis of red fluorescence
Range0–20 mg/L (0–20,000 ppb)
Accuracy±0.2 mg/L (0–20 mg/L), ±1 ppb + 2% (ppb range)
Resolution0.01 mg/L or 1 ppb
Response Time (t₉₀)≤30 s
Operating Temperature−5 to 50 °C
IP RatingIP68
Submersible DepthUp to 30 m
CompensationAutomatic temperature, atmospheric pressure, and salinity compensation
OutputRS485 (Modbus RTU), 4–20 mA analog
Sensor Lifetime1–3 years (fluorescent cap)
Drift<1% per year
CalibrationAir-saturated water auto-calibration
Installation OptionsImmersion, flow-through, buoy-mounted
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYST (Dalian Yistek)
OriginLiaoning, China
ModelYST909B-CH980
Measurement Range0.01–200 mg/L as Cl₂
Resolution0.001–0.1 mg/L
Accuracy±0.15% of full scale
Response Time (T90)≤120 s
Operating Temperature0–60 °C
Humidity Limit<95% RH (non-condensing)
Sample Temp.0–45 °C
Sample Flow Rate≈500 mL/min
Sample Pressure0.1–0.3 bar
Power SupplyAC 100–240 V / DC 18–36 V
Power Consumption12–120 W
Enclosure RatingIP65
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYST (Dalian Yist Instrument Co., Ltd.)
OriginLiaoning, China
ModelYST909B-CH980
Measurement PrincipleElectrochemical and DPD-based Spectrophotometric Methods
Range (Electrochemical)0.01–200 mg/L as Cl₂
Range (Spectrophotometric)0.0–10.0 mg/L as Cl₂
Resolution (Electrochemical)0.001–0.1 mg/L
Resolution (Spectrophotometric)0.01 mg/L
Accuracy±0.15% of full scale or ±0.05 mg/L (whichever is greater)
Response Time (T90)≤120 s (electrochemical), ≤2.5 min (free chlorine), ≤3.5 min (total chlorine)
Operating Environment0–60 °C, <95% RH (non-condensing), vibration-free, well-ventilated indoor space
Power SupplyAC 100–240 V / DC 18–36 V
Power Consumption≤120 W
Enclosure RatingIP65/IP66
Output InterfacesRS-232, RS-485, 4–20 mA analog output
Data Storage Capacity14,000 records
Auto-calibration & Self-diagnostic FunctionsYes
Sampling IntervalProgrammable from 1 to 999 minutes
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYST (Dalian Yist)
OriginLiaoning, China
ModelYST208B-CR810
Measuring Range0–10 m
Accuracy±0.5% to ±1% FS
Resolution1 mm
Ultrasonic Frequency20–200 kHz
Transmitter Operating Temperature−20 °C to +70 °C
Sensor Operating Temperature0 °C to +70 °C
Enclosure RatingIP65 (Transmitter), IP68 (Sensor)
Power SupplyAC 220 V or DC 24 V
Output Signals4–20 mA analog, RS485 digital (Modbus RTU)
InstallationFixed bracket mount
Maintenance IntervalQuarterly
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYST (Dalian Yisite)
OriginLiaoning, China
ModelYST909B-CH980
Measurement Range0–1 mg/L / 0–5 mg/L / 0–10 mg/L (selectable)
Resolution0.001 mg/L (low range), 0.01 mg/L (mid/high range)
Repeatability≤1%
Response Time (T90)≤60 s
Operating Temperature0–50°C (indoor), –10–60°C (outdoor explosion-proof version)
Humidity≤90% RH (non-condensing)
Sample Temp.0–50°C
Sample Pressure0.1–0.6 MPa
Output4–20 mA analog, RS485/RS232 (Modbus RTU)
Relay Outputs2 configurable (NO/NC, 220 VAC/5 A)
Power SupplyAC 220 V ±10%, 50 Hz or DC 24 V
Sampling ModesFlow-through (50–300 mL/min) and Immersion
Auto-CleaningYes
ComplianceDesigned for ISO 9001-manufactured systems
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYST (Dalian Yist Environmental Technology Co., Ltd.)
OriginLiaoning, China
ModelYST208B-CR810
Measuring Range0.5–20 m (sensor-dependent)
Accuracy±0.5% to ±1% FS
Resolution1 mm
DisplayBilingual LCD with trend graph
Output Signals4–20 mA analog, RS485/Modbus RTU digital
Alarm Outputs2–4 relay channels (5 A / 250 VAC)
Power SupplyAC 220 V ±10% or DC 12–24 V
Power Consumption<5 W
Enclosure RatingIP65 (main unit), IP68 (sensor)
Housing MaterialABS/aluminum (unit), 304/316L stainless steel (sensor)
Standard Cable Length10 m (customizable)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYST (Dalian Yist)
OriginLiaoning, China
ModelYST308B-MS880T
Measurement PrincipleInfrared Light Scattering (ISO 7027 Compliant)
Range0–20 g/L
Resolution0.01 g/L
Accuracy±2% FS
Sensor IP RatingIP68
Transmitter IP RatingIP65
Response Time (T90)≤10 s
Operating Temp (Sensor)0–60 °C
Operating Temp (Transmitter)0–50 °C
Humidity≤90% RH (non-condensing)
Power SupplyAC 220 V ±10%, 50/60 Hz
Output Signals4–20 mA (≤500 Ω load), RS485 Modbus RTU
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYST (Dalian Yist Instrument Co., Ltd.)
OriginLiaoning, China
ModelYST909B-CH980
Measurement Range0–1 mg/L / 0–5 mg/L / 0–10 mg/L (selectable)
Resolution0.001 mg/L (low range), 0.01 mg/L (mid/high range)
Repeatability≤1% FS
Response Time (T90)≤60 s
Operating TemperatureIndoor: 0–50°C
Outdoor Explosion-Proof−10–60°C
Humidity≤90% RH (non-condensing)
Sample Temperature0–50°C
Sample Pressure0.1–0.6 MPa
Output Signals4–20 mA analog, RS485/RS232 (Modbus RTU)
Alarm Outputs2 relay outputs (NO/NC, 220 VAC / 5 A)
Power SupplyAC 220 V ±10%, 50 Hz or DC 24 V
Sampling ModesFlow-through (50–300 mL/min) or Immersion
Accuracy±2% FS (full scale)
Zero Drift (30 days)≤±0.05 mg/L
Span Drift (30 days)≤±2% FS
Auto Temperature & pH CompensationYes
Data Storage Capacity>80,000 records
Update RateUp to 1 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYST (Dalian Yist Instrument Co., Ltd.)
OriginLiaoning, China
ModelYST809B-DO660
Measurement Range0–20 mg/L DO / 0–200% saturation
Accuracy±0.1 mg/L (0–10 mg/L), ±0.2 mg/L (10–20 mg/L)
Temperature Compensation0–60 °C (automatic)
Response Time (t₉₀)≤60 s
Output Signals4–20 mA analog + RS485 digital (Modbus RTU)
Power SupplyAC 220 V ±10% or DC 24 V
Operating Environment0–50 °C, ≤90% RH (non-condensing)
Installation OptionsSubmersible, Flow-through, Pipe-mount
IP RatingIP68 (sensor), IP65 (transmitter)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYST
OriginLiaoning, China
ModelYST809B-DO660
Measurement Range0.00–20.00 mg/L DO
Accuracy±0.5% FS
Fluorescent Cap Lifetime≥12 months (typical operation)
Temperature CompensationAutomatic, 0–50 °C
Enclosure RatingIP68
Communication InterfaceRS485
Power SupplyAC 220 V or DC 12 V (solar-compatible)
User InterfaceChinese LCD, one-button calibration
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYST (Dalian Yist)
OriginLiaoning, China
ModelYST308T-MS870Z
Measurement PrincipleInfrared Light Scattering
Range0–50 g/L
Resolution0.01 g/L
Accuracy±1% FS
Sensor Operating Temp.0–60 °C
Host Operating Temp.0–50 °C
Humidity≤90% RH (non-condensing)
Power SupplyAC 220 V ±10%, 50/60 Hz
Sensor IP RatingIP68
Host IP RatingIP65
Response Time (T90)≤10 s
Output Signals4–20 mA (load ≤500 Ω), RS485 (Modbus RTU)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYST (Dalian Yist Environmental Technology Co., Ltd.)
OriginLiaoning, China
ModelYST909B-CH980
Measurement RangeFree Chlorine 0–5 mg/L (extendable to 0–20 mg/L), Total Chlorine 0–10 mg/L (extendable to 0–50 mg/L)
Resolution0.01 mg/L
Accuracy±2% FS or ±0.02 mg/L (whichever is greater)
Response Time≤60 s (T90)
Operating Temperature0–50 °C
Humidity10–90% RH (non-condensing)
Power SupplyAC 220 V ±10%, 50 Hz or DC 12–24 V
Output Signals4–20 mA analog, RS485 digital (Modbus RTU protocol)
Ingress ProtectionIP65
CalibrationAutomatic (programmable interval) or manual
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDalian YST
OriginLiaoning, China
ModelYST909B-CH980
Measurement Range0–1 mg/L / 0–5 mg/L / 0–10 mg/L (selectable)
Resolution0.001 mg/L (low range), 0.01 mg/L (mid/high range)
Repeatability≤1%
Response Time (T90)≤60 s
Operating Temperature0–50°C (indoor), –10–60°C (outdoor explosion-proof version)
Humidity≤90% RH (non-condensing)
Sample Temperature0–50°C
Sample Pressure0.1–0.6 MPa
Output Signals4–20 mA, RS485/RS232 (Modbus RTU)
Relay Outputs2 configurable (NO/NC, 220 VAC / 5 A)
Power SupplyAC 220 V ±10%, 50 Hz or DC 24 V
Sampling ModesFlow-through (50–300 mL/min) and Immersion
Zero Drift±0.05 mg/L over 30 days
Span Drift±2% FS over 30 days
CompensationAutomatic temperature and pH compensation
Turbidity Tolerance≤100 NTU
pH Range for Stable Operation6–9
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYST Environmental
OriginLiaoning, China
ModelYST308B-MS880T
Measurement Range0–5000 mg/L (extendable to 0–50000 mg/L)
Measurement PrincipleDual-beam infrared scattering and transmission hybrid optics
Output Signals4–20 mA analog output, RS485 digital interface (HJ 212 protocol compliant)
Power SupplyAC 220 V ±10%, 50 Hz
Operating Temperature−10 °C to +55 °C
Ingress ProtectionIP68
Installation OptionsSubmersible or flow-through configurations
Cleaning MechanismIntegrated air-pulse auto-cleaning system
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYST (Dalian Yist Environmental Technology)
OriginLiaoning, China
ModelYST308B-MS880T
Measurement Range0–20,000 mg/L
Accuracy≤ ±2% FS
Output Signal4–20 mA DC
Power SupplyAC 220 V ±10%, 50/60 Hz
Operating Temperature−10 °C to +55 °C
Relative Humidity10–90% RH (non-condensing)
Ingress ProtectionIP65
Installation OptionsImmersion or Flow-Through
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYST (Dalian Yist Environmental Technology Co., Ltd.)
OriginLiaoning, China
ModelYST308B-MS880T
Measurement PrincipleInfrared Scattering (880 nm)
Range0–50,000 mg/L (multi-range configurable)
Power SupplyDC 12–24 V, <50 mA avg.
Output Signals4–20 mA analog, RS485 digital (Modbus RTU)
Sensor IP RatingIP68
Host IP RatingIP65
Sensor Operating Temp.−10 to 60 °C
Host Operating Temp.0 to 50 °C
Installation OptionsTop-mount, side-mount, submersible
Sensor Material316 stainless steel
Housing MaterialPOM engineering plastic
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYST (Dalian Yist)
OriginLiaoning, China
ModelYST308B-MS880T
Measurement Range0–5000 mg/L SS, 0–80.0 °C
Accuracy±1.5% FS (SS), ±0.3 °C (Temp)
Resolution1 mg/L (SS), 0.1 °C (Temp)
Output4–20 mA & RS485 MODBUS RTU
Power Supply85–265 VAC ±10%, 50 ±1 Hz, ≤3 W
IP RatingIP65
InstallationPanel-mount / Wall-mount / In-line pipe mount
Operating Environment−10 to +60 °C, ≤90% RH, non-corrosive, no strong magnetic field
ComplianceHJ 212–2017 (China Emission Monitoring Data Transmission Standard)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYST Instrument (Dalian)
OriginLiaoning, China
ModelYST308B-MS880T
Measurement PrincipleTransmittance-Scattering Hybrid Optical Method
Range0–5000 mg/L
Accuracy≤±2% FS
Resolution1 mg/L
Response Time (T90)≤10 s
Operating Temp. (Sensor)−10–80 °C
Operating Temp. (Transmitter)0–50 °C
Humidity≤90% RH (non-condensing)
pH Compatibility2–12
Output SignalsIsolated 4–20 mA analog + RS485 digital (Modbus RTU)
Power SupplyAC 220 V ±10% 50/60 Hz or DC 24 V ±10%
Enclosure RatingSensor IP68, Transmitter IP65
CleaningIntegrated Automatic Wiper System
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYST (Dalian Yist Instrument Co., Ltd.)
OriginLiaoning, China
ModelYST308B-MS880T
Measurement PrincipleInfrared Dual-Scatter Optical Detection
Range0–5000 mg/L (extendable to 0–20,000 mg/L)
Accuracy±2% FS (0–100 mg/L), ±5% FS (100–5000 mg/L)
OutputRS485 with Modbus RTU Protocol
Power SupplyDC 12–24 V, <50 mA avg.
Operating Temperature−5 to +50 °C
Humidity<85% RH (non-condensing)
Enclosure RatingIP68
Housing Material316 Stainless Steel + Polyoxymethylene (POM)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDalian YST
OriginLiaoning, China
ModelYST308B-MS880T
Measurement Range0–50 g/L (activated sludge), 0–400 g/L (silica)
Unitsmg/L / ppm selectable
Accuracy±1–2% FS
Repeatability±1–2%
Operating Temp.0–50 °C
Max. Pressure≤10 bar
Flow Rate0.3–3 m/s
Output4–20 mA isolated
CommunicationModbus RTU/ASCII
Enclosure RatingTransmitter IP65, Sensor IP68
Power SupplyAC 220 V or DC 24 V
Weight6 kg
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0