Empowering Scientific Discovery

Dalian Istar Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYST (Dalian Yistek)
OriginLiaoning, China
ModelYST909B-CH980
Measurement Range0.01–200 mg/L as Cl₂
Resolution0.001–0.1 mg/L
Accuracy±0.15% of full scale
Response Time (T90)≤120 s
Operating Temperature0–60 °C
Humidity Limit<95% RH (non-condensing)
Sample Temp.0–45 °C
Sample Flow Rate≈500 mL/min
Sample Pressure0.1–0.3 bar
Power SupplyAC 100–240 V / DC 18–36 V
Power Consumption12–120 W
Enclosure RatingIP65
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYST (Dalian Yist Instrument Co., Ltd.)
OriginLiaoning, China
ModelYST909B-CH980
Measurement PrincipleElectrochemical and DPD-based Spectrophotometric Methods
Range (Electrochemical)0.01–200 mg/L as Cl₂
Range (Spectrophotometric)0.0–10.0 mg/L as Cl₂
Resolution (Electrochemical)0.001–0.1 mg/L
Resolution (Spectrophotometric)0.01 mg/L
Accuracy±0.15% of full scale or ±0.05 mg/L (whichever is greater)
Response Time (T90)≤120 s (electrochemical), ≤2.5 min (free chlorine), ≤3.5 min (total chlorine)
Operating Environment0–60 °C, <95% RH (non-condensing), vibration-free, well-ventilated indoor space
Power SupplyAC 100–240 V / DC 18–36 V
Power Consumption≤120 W
Enclosure RatingIP65/IP66
Output InterfacesRS-232, RS-485, 4–20 mA analog output
Data Storage Capacity14,000 records
Auto-calibration & Self-diagnostic FunctionsYes
Sampling IntervalProgrammable from 1 to 999 minutes
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYST (Dalian Yisite)
OriginLiaoning, China
ModelYST909B-CH980
Measurement Range0–1 mg/L / 0–5 mg/L / 0–10 mg/L (selectable)
Resolution0.001 mg/L (low range), 0.01 mg/L (mid/high range)
Repeatability≤1%
Response Time (T90)≤60 s
Operating Temperature0–50°C (indoor), –10–60°C (outdoor explosion-proof version)
Humidity≤90% RH (non-condensing)
Sample Temp.0–50°C
Sample Pressure0.1–0.6 MPa
Output4–20 mA analog, RS485/RS232 (Modbus RTU)
Relay Outputs2 configurable (NO/NC, 220 VAC/5 A)
Power SupplyAC 220 V ±10%, 50 Hz or DC 24 V
Sampling ModesFlow-through (50–300 mL/min) and Immersion
Auto-CleaningYes
ComplianceDesigned for ISO 9001-manufactured systems
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYST (Dalian Yist Instrument Co., Ltd.)
OriginLiaoning, China
ModelYST909B-CH980
Measurement Range0–1 mg/L / 0–5 mg/L / 0–10 mg/L (selectable)
Resolution0.001 mg/L (low range), 0.01 mg/L (mid/high range)
Repeatability≤1% FS
Response Time (T90)≤60 s
Operating TemperatureIndoor: 0–50°C
Outdoor Explosion-Proof−10–60°C
Humidity≤90% RH (non-condensing)
Sample Temperature0–50°C
Sample Pressure0.1–0.6 MPa
Output Signals4–20 mA analog, RS485/RS232 (Modbus RTU)
Alarm Outputs2 relay outputs (NO/NC, 220 VAC / 5 A)
Power SupplyAC 220 V ±10%, 50 Hz or DC 24 V
Sampling ModesFlow-through (50–300 mL/min) or Immersion
Accuracy±2% FS (full scale)
Zero Drift (30 days)≤±0.05 mg/L
Span Drift (30 days)≤±2% FS
Auto Temperature & pH CompensationYes
Data Storage Capacity>80,000 records
Update RateUp to 1 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYST (Dalian Yist Environmental Technology Co., Ltd.)
OriginLiaoning, China
ModelYST909B-CH980
Measurement RangeFree Chlorine 0–5 mg/L (extendable to 0–20 mg/L), Total Chlorine 0–10 mg/L (extendable to 0–50 mg/L)
Resolution0.01 mg/L
Accuracy±2% FS or ±0.02 mg/L (whichever is greater)
Response Time≤60 s (T90)
Operating Temperature0–50 °C
Humidity10–90% RH (non-condensing)
Power SupplyAC 220 V ±10%, 50 Hz or DC 12–24 V
Output Signals4–20 mA analog, RS485 digital (Modbus RTU protocol)
Ingress ProtectionIP65
CalibrationAutomatic (programmable interval) or manual
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDalian YST
OriginLiaoning, China
ModelYST909B-CH980
Measurement Range0–1 mg/L / 0–5 mg/L / 0–10 mg/L (selectable)
Resolution0.001 mg/L (low range), 0.01 mg/L (mid/high range)
Repeatability≤1%
Response Time (T90)≤60 s
Operating Temperature0–50°C (indoor), –10–60°C (outdoor explosion-proof version)
Humidity≤90% RH (non-condensing)
Sample Temperature0–50°C
Sample Pressure0.1–0.6 MPa
Output Signals4–20 mA, RS485/RS232 (Modbus RTU)
Relay Outputs2 configurable (NO/NC, 220 VAC / 5 A)
Power SupplyAC 220 V ±10%, 50 Hz or DC 24 V
Sampling ModesFlow-through (50–300 mL/min) and Immersion
Zero Drift±0.05 mg/L over 30 days
Span Drift±2% FS over 30 days
CompensationAutomatic temperature and pH compensation
Turbidity Tolerance≤100 NTU
pH Range for Stable Operation6–9
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYST (Dalian Yist)
OriginLiaoning, China
ModelYST909B-CH980
Measurement PrincipleModified DPD Colorimetry + Membrane-Amperometric Sensor
Range0.01–10 mg/L Free Chlorine
Accuracy≤±0.01 mg/L (0.01–1 mg/L range)
Drift≤±0.03 mg/L over 72 h
Power SupplyAC 220 V ±10%, 50 Hz (solar-compatible option available)
Output4–20 mA analog + RS485 Modbus RTU
Environmental RatingIP65
Operating Temperature0–50 °C
Relative Humidity10–90% RH (non-condensing)
Data StorageInternal logging with trend report export capability
ComplianceGB/T 5750.11–2006
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYST (Dalian Yist Environmental Technology Co., Ltd.)
OriginLiaoning, China
ModelYST909B-CH980
Measurement RangeFree Chlorine 0–5 mg/L (extendable to 0–20 mg/L), Total Chlorine 0–10 mg/L (extendable to 0–50 mg/L)
Resolution0.01 mg/L
Accuracy±2% FS or ±0.02 mg/L (whichever is greater)
Response Time (T90)≤60 s
Operating Temperature0–50 °C
Relative Humidity10–90% RH (non-condensing)
Power SupplyAC 220 V ±10%, 50 Hz or DC 12–24 V
Output Signals4–20 mA analog, RS485 digital (Modbus RTU protocol)
Ingress ProtectionIP65
CalibrationAutomatic (programmable interval) or manual
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYST (Dalian Yist Instrument Co., Ltd.)
OriginLiaoning, China
ModelYST909B-CH980
Measurement Range0–10 mg/L free chlorine
Accuracy±2% FS (0–5 mg/L)
Response Time≤60 s (T90)
Zero Drift≤±0.05 mg/L over 30 days
Span Drift≤±2% FS over 30 days
Operating Temperature0–50 °C
Relative Humidity≤85% RH (non-condensing)
Power SupplyAC 220 V ±10%, 50 Hz
Output Signals4–20 mA analog output
Data Storage6-month timestamped history (local), USB export supported