Empowering Scientific Discovery

Dianjiang (Shanghai) Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandArgus
OriginGermany
ModelPiCUS TreeQinetic
ApplicationNon-destructive in-situ assessment of trunk and root anchorage stability under controlled tensile loading
Measurement PrincipleQuasi-static mechanical displacement-based biomechanical response analysis
Key ComponentsWireless elastometer (±2 mm, 0.1 µm resolution), dual-axis inclinometer (±15°, 0.002° resolution), digital forcemeter (0–60 kN, 0.01 kN resolution), overload indicator, Bluetooth-enabled data hub, and proprietary TreeQinetic software suite
ComplianceDesigned for field use in accordance with DIN EN 1991-1-4 (wind actions), ISO 17225-6 (biomass stability reference frameworks), and GLP-aligned data integrity protocols
PowerRechargeable Li-ion battery pack (10 h typical runtime at 20°C)
Wireless RangeUp to 30 m (line-of-sight, Bluetooth 5.0)
Mechanical SystemWinch assembly rated for 2800 kg pulling force
Added to wishlistRemoved from wishlist 0
Add to compare
BrandArgus
OriginGermany
ModelPiCUS-3
Sensor Count6 or 12
Sensor Cable Length3.5 m
Measurement PrincipleElastic Wave Propagation Time-of-Flight Tomography
Spatial Resolution1 µs time resolution
Operating Battery Life>6 h
Charging Time2 h
GPS Accuracy0–20 m
DisplayColor LCD (real-time tomographic visualization)
Data TransferUSB 2.0 or Bluetooth (range: 0.5–10 m)
Dimensions55 × 42 × 13 cm
Weight8.9 kg
Integrated Height MeasurementYes
Optional Electronic Caliper Range160–2150 mm (stainless steel)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandArgus
OriginGermany
ModelTMS3
Weight73 g
Dimensions61 mm × 41 mm × 20 mm
IP RatingFully Sealed, Waterproof & Dustproof
Tilt Measurement Accuracy±0.03°
Sampling Frequency20 Hz (50 ms interval)
Measurement Axes3D (X/Y/Z, cardinal directions)
Operating Temperature Range−20 °C to +50 °C
Battery Capacity250 mAh
Continuous Operation>15 days
ChargingWireless (Qi-compatible)
Data Storage256 MB (≈20 days at 20 Hz)
CommunicationBluetooth 2.1
Sensor MountingOmnidirectional
Control Sensor Height2–3 m above ground
Base Sensor PlacementAt root collar / anchorage zone
Added to wishlistRemoved from wishlist 0
Add to compare
BrandArgus
OriginGermany
ModelPiCUS TreeTronic 3
Measurement PrincipleElectrical Resistance Tomography
Max Electrode Count24
Minimum Electrodes Required10
Max Output Current20 mA
Max Output Voltage80 V
Measurement ModesTwo-point & Three-point
Electrode Cable Length3.5 m
Tree Diameter Range3–250 cm (extendable)
Onboard Storage>100 scans
DisplayColor LCD (real-time ERT visualization)
Data TransferUSB 2.0 / Bluetooth
Integrated GPS & BluetoothYes
Battery Life>4 h continuous operation
Charging Time≤2 h
Weight8.9 kg
Dimensions55 × 42 × 13 cm
Optional Electronic DendrometerRange 160 mm–2150 cm, Stainless Steel Construction, LED Display, Bluetooth Sync
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHaglof Inc.
OriginSweden
ModelPostex
Dimensions93 × 63 × 72 mm
Weight (instrument)243 g
Weight (tripod assembly)4.85 kg
Ultrasonic Range≥30 m (with 360° adapter: ≥20 m)
Laser Range0.46–700 m
Laser Accuracy±4 cm
Angular Accuracy±0.1°
Angular Resolution0.1°
Distance Resolution (ultrasonic)0.01 m
Distance Resolution (laser, DME mode)0.01 m
Operating Temperature−20 °C to +45 °C
IP RatingIP67 / NEMA 6
Laser ClassIEC 60825-1:2001 Class 1M, FDA 21 CFR Part 1040.10 Class 1
BatteryInternal 3.7 V rechargeable Li-ion (~9,000 measurements per charge
InterfaceUSB Mini-B, Bluetooth SPP (PIN: 1234), IR
Data Output FormatNMEA or ASCII
Tripod Arm ExtensionUp to 125 cm from center
Reflector Beacon (A/B/C)Ø70 mm, 85 g each, 1.5 V AA alkaline, max. 9 mW
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDelta-T Devices
OriginUnited Kingdom
ModelAP4
Measurement PrincipleSteady-state diffusion-based porometry
Weight3.0 kg (main unit), 130 g (sensor head)
Operating TimeUp to 20 h on internal rechargeable battery
Data Storage1500 readings
InterfaceRS232 (9600 baud)
ComplianceDesigned for GLP-aligned field and lab use
SoftwareWindows-compatible CSV export utility
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHansatech (distributed by SUSS, Germany)
OriginUnited Kingdom
ModelM-PEA-1
Power Supply12 V DC, 1 A
Operating Temperature0–40 °C
Dimensions230 × 190 × 85 mm
Weight1.4 kg
Data InterfaceUSB 2.0
Sampling Rate10 µs
A/D Resolution16-bit
Actinic Light SourceHigh-intensity red LED (peak 625 nm, FWHM 20 nm), up to 5000 µmol m⁻² s⁻¹
Far-Red Light SourceHigh-brightness LED with long-pass filter, >1000 µmol m⁻² s⁻¹
P700⁺ MeasurementModulated 820 nm LED (1–100% intensity, 1% step)
Fluorescence DetectionLow-noise, fast-response PIN photodiode with 730 nm ±15 nm bandpass filter
P700⁺ DetectionLow-noise, fast-response PIN photodiode with dedicated bandpass filtering
Optical SealingQuartz-glass encapsulation for dust, moisture, and contamination resistance
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPMS
OriginUSA
Model1515D
Measurement Range0–100 bar
Accuracy±1% of reading (at 50 bar, half-scale)
Chamber MaterialStainless Steel
Chamber Internal Dimensions6.35 cm ID × 12.7 cm depth
DisplayDigital backlit pressure gauge with selectable units (bar, MPa, psi)
Gas SupplyIntegrated 20 ft³ aluminum nitrogen cylinder (max pressure 207 bar)
Weight~16 kg (instrument only)
cylinder3.9 kg
Overall Dimensions56 × 38 × 26 cm
Seal OptionsStandard 6.35 mm compression seal
Accessories7× and 3.5× magnifying eyepieces (AAA-powered), LED-illuminated 10× handheld eyepiece, gas-saver valve (full- or half-range), sample insertion tools (1/8", 3/16", 1/4" OD), reusable moisture-equilibration sample bags (species-specific sizing), stainless steel chamber base caps (9.525 mm, 12.7 mm, grass-leaf)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandQubit
OriginCanada
ModelQ-Box CO650
CO₂ Analyzer PrincipleNon-Dispersive Infrared (NDIR)
Gas Flow ModeOpen-flow, Closed-chamber Configuration
Flow Rate650 mL/min
CO₂ Measurement Range (Display)0–1999 ppm
CO₂ Accuracy±1 ppm (after calibration)
CO₂ Repeatability±1 ppm (under stable T/P)
Response Time (t₉₅)~25 s (at 250 mL/min)
Warm-up Time~5 min (at 22°C)
PAR OutputUp to 1200 µmol·m⁻²·s⁻¹ (white LED, leaf surface)
Leaf Chamber Volume9 mL
Chamber Dimensions3.0 × 5.3 × 25.5 cm (H×W×L)
Data Logger3 analog + 2 digital inputs, USB 2.0, 100 kS/s sampling rate
Operating Temp0–50°C
Storage Temp−40–+70°C
Humidity Range5–90% RH (non-condensing)
Power12 V DC or 120 V AC/60 Hz adapter
Weight (Analyzer Unit)1.0 kg
Weight (Pump Unit)0.9 kg
Warranty1 year
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDianJiang
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelECA-YLS01
Price RangeUSD 7,000 – 14,000
Light Source470 nm Blue LED
Photosynthetic Photon Flux Density (PPFD)0–5000 μmol·m⁻²·s⁻¹ (adjustable)
Minimum Sampling Interval2 μs
Data Acquisition RateUp to 500,000 points per second
Onboard Storage4 GB microSD card
InterfaceUSB 2.0
Display128 × 64 monochrome LCD
Power SupplyRechargeable Li-ion battery (7.6 V, 2.6 Ah)
Weight400 g
Dimensions12.5 × 8.0 × 3.3 cm
Dark Adaptation ClipIntegrated, leaf-compatible design
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBronkhorst
OriginFrance
ModelXYL’EM-Plus
Flow Measurement PrincipleThermal Mass Flow Sensing
Flow Range0.5–100 g/h H₂O (standard internal sensor: 50 g/h)
Flow Accuracy±1% of full scale
Low-Pressure Range1–10 kPa (water column, max 10 kPa)
Low-Pressure Accuracy±0.2 kPa
High-Pressure Range0–10 bar
High-Pressure Accuracy±1% of full scale
Temperature Range0–50 °C (Pt100 probe)
Temperature Accuracy±0.2 °C
High-Pressure Reservoir Capacity0.7 L
Max Reservoir Pressure3 bar (safety valve rated to 5 bar)
Low-Pressure Reservoir Capacity100 mL
Max Low-Pressure Head1 m H₂O
Filtration0.45 µm
Enclosure RatingIP65
Dimensions (W×D×H)461 × 347 × 206 mm
Weight10 kg (dry)
Power Supply12 VDC, 900 mA
Data Acquisition15-bit ADC
Communication InterfaceRS232
SoftwareXYL’EM v3.x (DOS/Windows-compatible), supports real-time data logging, embolism factor calculation, and hydraulic conductivity normalization
Added to wishlistRemoved from wishlist 0
Add to compare
BrandEcomatik
OriginGermany
ModelDF1 / DF2 / DF3
Measurement PrincipleHigh-Resolution Linear Displacement Transduction via Spring-Loaded Contact Probe
Sensor Range15 mm (DF1), 25.4 mm (DF2), 50.8 mm (DF3)
Full-Scale Diameter Monitoring Range0–110 mm (expandable)
Accuracy±2 µm (DF1), ±3.3 µm (DF2), ±6.6 µm (with CR1000 Logger)
Resolution0.04% of reading + 6–20 µm (logger-dependent)
Temperature Coefficient<0.2 µm/°C
Operating Temperature−25 to +70 °C
Relative Humidity0–100% RH
Weight15 g (DF1), 26 g (DF2), 37 g (DF3)
PowerInternal battery, >2 years continuous logging (with DL10 datalogger)
Data StorageUp to 1,900,000 records (4 sensors, 1-min interval, 1-year capacity)
InterfaceAnalog voltage output (0–2.5 V or 0–5 V), compatible with Campbell Scientific CR1000/CR6, Delta-T Devices GP2, DataTaker DT80/DT85, and other standard analog-input loggers
IP RatingIP67 (fully weatherproof)
Show next