- All
- Favorite
- Popular
- Most rated
| Brand | Aeroqual |
|---|---|
| Origin | New Zealand |
| Model | AQS1 |
| Particle Measurement | PM1, PM2.5, PM10, TSP |
| Gas Measurement | O₃ (0–0.5 ppm), NO₂ (0–0.5 ppm), VOCs (0–0.5 ppm) |
| Meteorological Inputs | Temperature, Relative Humidity, Barometric Pressure, Wind Speed & Direction, Solar Radiation, Rainfall |
| Noise Measurement | 30–100 dB(A) |
| Sampling Method | Pump-aspirated with heated inlet (PM), dual-stage active flow control |
| Detection Limits | PM <1 µg/m³ |
| Accuracy | PM ±(2 µg/m³ + 5% of reading) |
| Operating Temperature | −10 °C to +45 °C |
| Enclosure | IP65 fiberglass housing with aluminum solar radiation shield |
| Power | 100–260 VAC (31.3 W) or 12 VDC (34.3 W) |
| Data Storage | 32 GB SSD (≥5 years at 1-min interval) |
| Connectivity | Wi-Fi, Ethernet, optional 4G HSPA cellular modem |
| Software | Aeroqual Connect (on-device web interface), Aeroqual Cloud (secure encrypted cloud platform) |
| Compliance | Designed for alignment with ISO 12103-1 (aerosol calibration), EN 14625 (O₃ monitoring), EN 14626 (NO₂ monitoring), and US EPA EQOA requirements for near-reference-grade performance |
| Brand | Aeroqual |
|---|---|
| Origin | New Zealand |
| Model | AQM 65 |
| Power Supply | 90–264 VAC, 47–63 Hz |
| Operating Temperature | −35 °C to +50 °C |
| Enclosure Rating | IP65 |
| Dimensions (standard) | 1310 × 510 × 290 mm (H×W×D) |
| Weight | ~25 kg |
| Core Computing Platform | Intel Atom N2600, 1.6 GHz, 2 GB RAM, 32 GB SSD, Ubuntu Linux |
| Communication | Wi-Fi, Ethernet (LAN), optional cellular GPRS modem |
| Gas Sampling | 12 V brushless diaphragm pump, PTFE-lined stainless steel inlet |
| Thermal Management | DC compressor (R134a), 12–24 V, 60 W resistive heater |
| Data Transmission | Aeroqual Cloud (encrypted), FTP/email export (optional), SMS/email alerts (optional) |
| Calibration Options | AirCal 1000 (portable), AirCal 8000 (integrated) |
| Certified Sensor Modules | Gill WindSonic (ultrasonic wind), Vaisala WXT536 (weather), Cirrus MK427 Class 1 (noise), Novalynx pyranometer (solar radiation) |
| Measured Gases | O₃ (0–0.5 ppm), NO₂ (0–0.2 ppm), NOₓ (0–0.5 ppm), CO (0–25 ppm), SO₂ (0–10 ppm), H₂S (0–10 ppm), CO₂ (0–2000 ppm), VOC (0–20 ppm) |
| Particulate Matter | PM₁/PM₂.₅/PM₁₀/TSP via optical particle counter (±5 µg/m³ + 15% of reading) and turbidimeter (±2 µg/m³ + 5% of reading) |
| Meteorological Parameters | Wind speed/direction, temperature, relative humidity, barometric pressure, rainfall, solar irradiance |
| Noise Monitoring | 30–100 dB(A), Class 1 accuracy per IEC 61672-1 |
Show next