Empowering Scientific Discovery

Dongyang Precision Measurement Systems (Shanghai) Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTOYO Corporation (Japan)
OriginJapan
Manufacturer TypeAuthorized Distributor
Product CategoryImported Instrument
ModelAutoPEM
Instrument TypeElectrochemical Workstation
Channel CountSingle-Channel
Current RangeUp to 1000 A (multi-range selectable)
Current Accuracy±0.3% of reading
Potential Accuracy±0.3% of reading
Potentiostatic Range±20 V (between fuel and air electrodes)
EIS Frequency Range1 mHz to 10 kHz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNOVONIX
OriginCanada
ModelUHPC
Channel ConfigurationMulti-channel Electrochemical Workstation
Current Ranges200 μA, 2 mA, 20 mA, 200 mA, 2 A
Current Accuracy±0.005% of Full-Scale Reading (FSR)
Potential Accuracy±100 μV + 0.01% of FSR
Potentiostatic Range0–5 V
Stability (Typical)<10 ppm
Accuracy (Typical)<50 ppm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBio-Logic
OriginFrance
ModelBCS-905 / BCS-910 / BCS-915
Instrument TypeMultichannel Electrochemical Workstation & Battery Cycler
Channel ConfigurationModular Multichannel (up to 16 channels per rack)
Current RangeBCS-905: 15 µA–150 mA (5 ranges)
BCS-910150 µA–1.5 A (5 ranges)
BCS-9151.5 mA–15 A (5 ranges)
Current Accuracy±0.015% of range + ±0.05% of reading (15 µA–150 mA)
Potential Accuracy±0.01% of set value + 300 µV
Potentiostatic RangeBCS-905/910: 0–10 V
BCS-9150–9 V
EIS Frequency Range10 mHz–10 kHz
Resolution18-bit DAC/ADC for current and voltage control and acquisition
Thermal CompatibilityFixture support up to 150 °C
Parallel OperationScalable to 120 A via synchronized multi-unit parallel configuration
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTOYO Corporation (Japan)
OriginJapan
ModelMiniTest3000
Instrument TypeElectrochemical Workstation
Current Range4 nA – 1 A (10 decades)
Current Accuracy±0.2% of reading
Potential Accuracy±0.2% of reading
Potentiostatic Range±10 V
EIS Frequency Range10 µHz – 1 MHz
Anode MFC FlowH₂, up to 1.0 L/min (adjustable)
Cathode MFC FlowAir, up to 2.0 L/min (adjustable)
Humidification ControlDew point stabilized at 80 °C ±2 °C
Cell Temperature ControlRT +10 °C to 180 °C
Electronic LoadKikusui PLZ164W or PLZ164WA (165 W, 33 A, 0–150 V)
Footprint400 × 350 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTOYO Corporation (Japan)
OriginJapan
Manufacturer TypeAuthorized Distributor
Product CategoryImported Instrument
ModelAutoSOFC2
Instrument TypeElectrochemical Workstation
Current Range±25 A
Current Accuracy±0.3% of full scale
Potential Accuracy±0.3% of full scale
Potentiostatic Range±10 V
EIS Frequency Range1 mHz – 10 kHz