Environmental Monitoring Instruments
Filter
Showing 331–360 of 2621 results
| Brand | AMAE (Guoji Instruments) |
|---|---|
| Origin | Jiangsu, China |
| Model | AM-3200 Series |
| Detection Methods | Dual-FID + Optional GC-MS |
| Target Compounds | 57 PAMS VOCs (Dual-FID), up to 117 VOCs including TO-15 compounds and carbonyls (GC-MS mode) |
| Expandable to Odorants | H₂S, CH₃SH, CH₃SCH₃, CH₃SSCH₃, CS₂ |
| Sample Introduction | Continuous, cryo-trap-assisted preconcentration |
| System Inertness | High-inertness valves, tubing, and switching manifolds |
| Software | AMAE proprietary intelligent chromatographic analysis platform with automated peak identification, calibration management, and audit-ready data logging |
| Brand | -- |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | AM-IoT100 |
| Pricing | Available Upon Request |
| Brand | AMAE |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | AC-3072C |
| Instrument Type | Flue Gas Sampler |
| Sampling Flow Rate | 200–2000 mL/min |
| Brand | AMAE |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | AC-5000A |
| Instrument Type | Flue Gas and Ambient Air VOC Sampler |
| Sampling Flow Rate | 10–200 mL/min |
| Brand | AMAE |
|---|---|
| Origin | Guangdong, China |
| Model | ADS-2062E (2.0) |
| Application | TSP, PM10, PM2.5, and gaseous pollutants (SO₂, NOₓ) sampling via filter gravimetry and impinger absorption |
| Flow Range | 0.1–100 L/min (dual-channel independent control) |
| Load Capacity | >9 kPa at 100 L/min |
| Power Supply | Integrated rechargeable Li-ion battery (6–8 h operation at standard flow) |
| Weight | <4 kg (including thermoelectric temperature control module) |
| Compliance | HJ 618–2011, HJ 93–2013, HJ/T 374–2007, HJ/T 375–2007, HJ/T 376–2007, JJG 943–2011, JJG 956–2013 |
| Brand | AMAE |
|---|---|
| Model | CCZ30 |
| Type | Personal/Stationary Intrinsically Safe Dust Sampler |
| Flow Range | 3–30 L/min |
| Flow Resolution | 0.01 L/min |
| Compliance | GBZ 159-2004, GBZ/T 192.1–192.2, GB 16238-1996, GB 16248-1996, GBZ/T 300 (Dust), GBZ 2.1-2019 |
| Sampling Modes | Manual, Timed, Volume-Controlled, Cyclic |
| Data Logging | Internal Storage with Export (USB) & Optional Thermal Printout |
| Power | Rechargeable Li-ion Battery (High-Capacity, Extended Runtime) |
| Pump Type | Imported Brushless Electromagnetic Diaphragm Pump |
| Flowmeter | Imported Straight-Through Electronic Mass Flow Sensor |
| Accessories Included | Total Dust & Respirable Dust Sampling Heads (Φ40 mm), Filter Holders, Calibration Orifice, Tripod, Charger |
| Brand | AMAE |
|---|---|
| Model | CCZ5(A) |
| Application | Personal sampling of respirable and total dust in underground mines and occupational environments |
| Flow Range | 1000–6000 mL/min |
| Flow Resolution | 1 mL/min |
| Certifications | IECEx/ATEX Zone 0 (Class I, Div 1) & Zone 2 (Class II, Div 2) compliant |
| Compliance | GBZ 159-2004, GBZ/T 160 series, GBZ/T 300 series, GBZ 2.1-2019 |
| Power | Rechargeable Li-ion battery with >16 h continuous operation at 2 L/min |
| Environmental Rating | IP65 |
| Data Storage | Internal non-volatile memory (≥10,000 sample records) |
| Interface | USB-C for data export |
| Operating Temperature | −10 °C to +50 °C |
| Relative Humidity | ≤95 % RH (non-condensing) |
| Brand | AMAE |
|---|---|
| Model | CQB1500 |
| Type | Portable Intrinsically Safe Air Sampler |
| Certified Explosion-Proof Classes | I (Coal Mine) & II (Industrial Gas) |
| Flow Range | 10–2010 mL/min |
| Flow Resolution | 1 mL/min |
| Compliance | GBZ 159–2004, GBZ/T 160 series, GBZ/T 300 series, GBZ 2.1–2019 |
| Sampling Media Compatibility | Absorption Solutions, Sorbent Tubes, Filter Media |
| Operating Environment | -10 °C to +50 °C, ≤95% RH (non-condensing) |
| Battery Runtime | ≥12 h (typical at 500 mL/min) |
| Data Storage | Internal non-volatile memory (≥10,000 sample records) |
| Atmospheric Pressure Measurement | Integrated sensor (range: 60–115 kPa, accuracy: ±0.5 kPa) |
| Temperature Compensation | Built-in thermistor (±0.5 °C accuracy) |
| Standard Volume Correction | Automatic calculation per ISO 10780 & GBZ 159–2004 (at 25 °C, 101.325 kPa) |
| Brand | AMAE |
|---|---|
| Model | CQB300 |
| Type | Intrinsically Safe Personal Air Sampler for Hazardous Environments |
| Origin | Shenzhen, China |
| Flow Range | 10–300 mL/min |
| Flow Resolution | 1 mL/min |
| Explosion Protection | Certified for Class I and Class II hazardous locations |
| Compliance | GBZ 159-2004, GBZ/T 160 series, GBZ/T 300 series, GBZ 2.1-2019 |
| Power | Rechargeable high-capacity lithium battery |
| Sampling Modes | Manual, Timed, Volume-Controlled, Cyclic |
| Environmental Compensation | Integrated barometric pressure & ambient temperature sensing with automatic standard-condition (STP: 25 °C, 101.325 kPa) volume calculation |
| Data Handling | Onboard memory, USB data export, optional thermal printer support |
| Accessories | Anti-static shoulder strap, wall-mount charger, dual/quad sampler rack case, sorbent tube adapters |
| Brand | AMAE |
|---|---|
| Model | DS-30 |
| Sampling Flow Range | 3–30 L/min |
| Flow Accuracy | ±2% of reading |
| Operating Noise Level | <45 dB(A) |
| Power Supply | Rechargeable Li-ion battery (≥8 h continuous operation at 20 L/min) |
| Data Storage Capacity | 10,000 sampling records with timestamp, flow log, and event flags |
| Compliance | GBZ 159-2004, GBZ/T 192.1–192.2, GB/T 17061, GBZ/T 300, GBZ 2.1-2019 |
| Brand | AMAE |
|---|---|
| Origin | Guangdong, China |
| Model | EM-300 |
| Sampling Configuration | Single-Channel |
| Flow Range | 10–200 mL/min |
| Maximum Vacuum Pressure | >4.5 kPa |
| Flow Stability | <3% RSD |
| Flowmeter Accuracy | ±5% FS |
| Service Life at Max Load | >5,000 h |
| Continuous Operation | 40 h at 200 mL/min against 10 kPa backpressure |
| Compliance | Q/AMAE-2019, HJ 583–2010, JJG 956–2013, GB/T 17061–1997 |
| Brand | AMAE |
|---|---|
| Origin | Shenzhen, China |
| Model | EM-300E |
| Sampler Type | 24-Hour Temperature- and Flow-Controlled Dual-Channel Gas Sampler |
| Flow Range | 10–300 mL/min |
| Resolution | 1 mL/min |
| Maximum Vacuum Pressure | 30 kPa |
| Flow Stability | ≤2% |
| Flowmeter Accuracy | ≤3% |
| Service Life Under Max Load & Resistance | >5,000 hours |
| Continuous Operation Time at Max Flow & Load | 2–8 hours |
| Intrinsic Safety Certification | Yes (Explosion-Proof Rated) |
| Compliance | GBZ 159–2004, GBZ/T 160 series, GBZ/T 300 series, GBZ 2.1–2019 |
| Brand | AMAE |
|---|---|
| Model | EM-3040 |
| Type | Portable Flue Gas Analyzer |
| Measurement Principle | UV Differential Optical Absorption Spectroscopy (UV-DOAS) |
| Measurable Gases | SO₂, NO, O₂, CO, NO₂, CO₂ |
| Operating Temperature Range | -10 °C to 50 °C |
| Display | 8-inch TFT LCD, 800×600 resolution, 900 cd/m² brightness, 3-level adjustable backlight |
| Weight | ≈5 kg |
| Compliance | HJ/T 397–2007, JJG 968–2002, DB37/T 2641–2015, DB37/T 2704–2015, DB37/T 2705–2015, GB/T 16157–1996 |
| Brand | AMAE |
|---|---|
| Origin | Guangdong, China |
| Model | EM-3088-4.0 |
| Sampling Flow Rate | 0–110 L/min |
| Flow Accuracy | ±5% or better |
| Sample Type | Isokinetic particulate sampling + flue gas component analysis (O₂, SO₂, CO, NO, NO₂, H₂S, CO₂) |
| Compliance | Designed for fixed-source emission monitoring per Chinese EPA HJ/T 47–1999, HJ/T 48–1999, and compatible with ISO 16911-1:2013 principles |
| Power | Integrated rechargeable battery for field operation |
| Water Removal | Triple-stage condensate removal with auto-drain function |
| Data Output | Real-time parametric logging including stack temperature, static/dynamic pressure, atmospheric pressure, moisture content, flow velocity, and volumetric flow |
| Brand | AMAE |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | EM-3088S |
| Price Range | USD 16,500 – 20,500 |
| Instrument Type | Flue Gas and Particulate Sampler |
| Sample Application | Isokinetic particulate sampling and real-time flue gas component analysis in exhaust ducts under industrial operating conditions |
| Sampling Flow Rate | 0–110 L/min |
| Flow Accuracy | ±5% or better |
| Flue Gas Velocity Range (Isokinetic Suction) | 1–50 m/s |
| Moisture Tolerance | Relative Humidity ≤95% RH |
| Brand | AMAE |
|---|---|
| Origin | Guangdong, China |
| Model | EM-500 |
| Instrument Type | Handheld Air Sampling Pump |
| Configuration | Single-Channel Gas Sampler |
| Flow Range | 10–600 mL/min |
| Maximum Backpressure Capacity | 4.5 kPa |
| Flow Stability | <3% |
| Flowmeter Accuracy | ±5% |
| Rated Service Life at Max Flow & Load | 5,000 h |
| Continuous Operation Time at Max Flow & Load | 12 h |
| Operating Temperature Range | −10 °C to +50 °C |
| Net Weight | 400 g |
| Display | Backlit LCD with Real-Time Parameter Monitoring |
| Power Source | Rechargeable Lithium Battery (≥24 h runtime under typical conditions) |
| Calibration Support | Compatible with Primary Soap Film Flowmeter |
| Compliance | GB 50325–2001/2006, JJG 956–2013, GB/T 17061–1997 |
| Brand | AMAE |
|---|---|
| Origin | Guangdong, China |
| Model | EM-5000 |
| Instrument Type | Handheld Air Sampling Pump |
| Configuration | Single-Channel Sampling System |
| Flow Range | 900–5100 mL/min |
| Maximum Vacuum Pressure | 4.5 kPa |
| Flow Stability | <3% RSD |
| Flowmeter Accuracy | ±5% FS |
| Rated Service Life at Max Flow & Backpressure | 5000 h |
| Continuous Operation Time at Max Flow & 5 kPa Backpressure | 12 h |
| Brand | AMAE |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Regional Category | Domestic (China) |
| Model | EM-5000E |
| Instrument Type | Handheld Air Sampling Pump |
| Configuration | Single-Channel Gas Sampler |
| Flow Range | 500–5650 mL/min |
| Flow Stability | ±2% |
| Flowmeter Accuracy | ±2.5% |
| Operational Lifetime at Max Flow & Backpressure | 40 h |
| Runtime at Max Flow & Backpressure | 40 h |
| Interface | USB Type-C (supports data export via USB flash drive, firmware updates, communication protocol expansion, and fast charging |
| Connectivity | Bluetooth 5.0, SparkLink (StarFlash), NFC |
| Calibration | On-device automatic calibration compatible with standard flow calibrators (e.g., dry calibrators, bubble meters, primary standards per ISO 13137) |
| Smart Controls | Programmable “Smart Key” (double-click/long-press configurable), voice activation (via integrated microphone and edge-based ASR engine), peer device cloning (“Fission Mode”) |
| Origin | USA |
|---|---|
| Model | FluoroQuik |
| Excitation Wavelength (Chl a) | 440 nm |
| Emission Wavelength (Chl a) | 670 nm |
| Excitation Wavelength (PC) | 600 nm |
| Emission Wavelength (PC) | 650 nm |
| Sample Volume | 0.5 mL (standard microcentrifuge tube) |
| Live Chl a Range | 0.25–200 ppb |
| Extracted Chl a Range | 0.25–2,500 ppb |
| Live Phycocyanin (PC) Range | 10–1,000 ppb |
| Extracted PC Range | 10–100,000 ppb |
| Detection Output | ppb or Relative Fluorescence Units (RFU) |
| Data Storage | 2 × 400 measurements (per channel) |
| Power Supply | 4 × AA alkaline batteries or 5 V DC / 2 A adapter |
| Dimensions | 5 × 9 × 3.5 cm |
| Weight | 280 g |
| Warm-up Time | < 10 s |
| Interface | LCD touchscreen with bilingual (English/Chinese) firmware |
| Data Transfer | USB port |
| Brand | AMS |
|---|---|
| Origin | USA |
| Model | 209.57 |
| Core Components | Stainless Steel |
| Connection Thread | 5/8" Unified National Fine (UNF) |
| Auger Diameter | 5.72 cm |
| Handle Length | 45.72 cm |
| Split-Core Sampler Diameter × Length | 3.49 cm × 15.24 cm |
| Extension Rod Length | 1.2 m |
| Plastic Liner Diameter × Length | 3.49 cm × 15.24 cm |
| Wrench Length | 30.48 cm |
| Stainless Steel Brush Diameter × Length | 3.81 cm × 30.48 cm |
| Standard Configuration | 1× General-Purpose Auger, 1× Sand Auger, 1× Clay Auger, 1× Rubber-Coated Handle, 1× Split-Core Sampler, 1× Standard Sliding Hammer, 3× Extension Rods, 1× Plastic Liner, 2× Plastic Caps, 2× Fixed-Size Wrenches, 1× Adjustable Wrench, 1× Stainless Steel Brush, 1× Premium Carrying Case |
| Brand | AMS |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | AMS Flue Gas Heavy Metal Sampler |
| Instrument Type | Particulate and Heavy Metal Sampling System |
| Target Analytes | Heavy Metals (e.g., Pb, Cd, Hg, As, Ni, Cr) |
| Flow Accuracy | ±2% |
| Compliance Standard | UNI-EN 14385 |
| Brand | AMS |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AMS Flue Gas Particulate Sampling System |
| Instrument Type | Isokinetic Particulate Sampler |
| Flow Accuracy | ±2% |
| Brand | AMS |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | AMS1 |
| Pricing | Upon Request |
| Brand | AMS |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AMS2 |
| Pricing | Upon Request |
| Construction Material | Stainless Steel |
| Sampling Depth | Up to 3.65 m |
| Kit Components | Main Sampling Probe, Internal Liner Tube, Handle, Adapter, Extension Rod |
| Brand | AMS |
|---|---|
| Origin | Italy |
| Model | AMS Dioxin |
| Instrument Type | Flue Gas Dioxin Sampling System |
| Flow Accuracy | ±2% |
| Compliance | UNI-EN 1948:2006 |
| Sampling Methods | Filter-Condensation, Dilution, Cooled Probe |
| Primary Adsorbent | XAD-2 Resin or PUF Foam |
| Heating Zone Temperature | <125 °C (maintained above gas dew point) |
| Condenser Outlet Temperature | <20 °C |
| Main Flow Rate | 3–5 m³/h |
| Side Stream Flow Rate | 0.5–0.7 m³/h |
| Side-to-Main Flow Ratio Tolerance | ±10% |
| Linear Velocity in XAD-2 Tube | ≤34 cm/s |
| Brand | AMS |
|---|---|
| Origin | USA |
| Model | AMS 209.55 / 209.56 / 209.57 / 209.58 |
| Connection Thread | 5/8" UNC |
| Core Diameter Options | 5.72 cm (2.25") or 8.26 cm (3.25") |
| Handle Length | 45.72 cm (18") |
| Split-Sample Auger Dimensions | 3.49 cm × 15.24 cm or 5.08 cm × 15.24 cm |
| Rod Length | 1.2 m (4 ft) per section |
| Plastic Liner ID | 3.49 cm or 5.08 cm × 15.24 cm |
| Wrench Length | 30.48 cm (12") |
| Stainless Steel Brush Diameter | 3.81 cm or 5.08 cm × 30.48 cm |
| Standard Configuration Includes | 3 soil-specific augers (general, sand, clay), rubber-coated T-handle, split-sampling auger, slide hammer, 3 extension rods, 1 liner (25 liners in 209.58), 2 plastic caps (50 caps in 209.58), 2 fixed wrenches, 1 adjustable wrench, 1 stainless steel brush, fluoropolymer film (50 sheets in 209.56/209.58), #2 stainless steel trowel (209.56/209.58), heavy-duty portable case |
| Brand | AMS |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GP |
| Price | USD 7,000 (FOB) |
| Brand | AMS |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GVP |
| Instrument Type | Handheld Air Sampling Pump |
| Configuration | Single-Channel Gas Sampler |
| Flow Range | 0–2 L/min |
| Operating Pressure | Ambient Atmospheric Pressure |
| Flow Stability | <2% over 1 h |
| Flowmeter Accuracy | ±2% FS |
| Service Life at Max Flow & Backpressure | >1000 h |
| Continuous Run Time at Max Flow & Backpressure | >2 h |
| Brand | AMS |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AMS HCl Flue Gas Sampling System |
| Instrument Type | Flue Gas Sampling System |
| Flow Accuracy | ±2% |
| Compliance | EN 1911, ISO 9096:1992 |
| Operating Probe Temperature | ≥120 °C (≥20 °C above HCl acid dew point) |
| Filter Efficiency | >99.5% (glass fiber or quartz fiber) |
| Sample Transit Time | <5 s (nozzle to impinger) |
| Main Stream Flow Rate | 30–150 L/min (isokinetic mode) |
| Impinger Flow Rate | 2–3 L/min |
| Typical Sampling Volume | 50–200 L (for [HCl] = 1–10 mg/m³ |
| Brand | AMS |
|---|---|
| Origin | Italy |
| Model | AMS Mercury Sampling System |
| Instrument Type | Flue Gas Sampling System |
| Target Analyte | Mercury (Hg) and Other Heavy Metals |
| Flow Accuracy | ±2% |
| Compliance | UNI-EN 13211 |
| Sample Path Material | Borosilicate Glass & Inert Heated Components |
| Probe Operating Temperature | ≥120 °C (≥20 °C above acid dew point) |
| Max. Sample Residence Time | <5 s (from probe inlet to impinger train) |