| Brand | Airmar |
|---|---|
| Origin | USA |
| Model | GH2183 |
| Operating Temperature | −25 to +55 °C |
| Power Supply | 9–40 VDC |
| Current Draw | <80 mA |
| GPS Channels | 14-channel WAAS/EGNOS-enabled |
| Heading Accuracy (Static) | 1° RMS |
| Heading Accuracy (Dynamic, up to ±30° pitch/roll) | 2° RMS |
| Heading Update Rate | 10 Hz (configurable up to 20 Hz on NMEA 2000®) |
| Pitch/Roll Range | ±50° |
| Pitch/Roll Accuracy (Dynamic) | <3° RMS |
| Rate of Turn Range | 0–70°/s |
| Rate of Turn Accuracy | ±1°/s |
| Compliance | CE, RoHS, IEC 60945, IPX6 |
| Brand | Airmar |
|---|---|
| Origin | USA |
| Model | H2183 |
| IP Rating | IPX6 |
| Operating Voltage | 9–40 VDC |
| Power Consumption | <30 mA |
| Operating Temperature | −25 to +55 °C |
| Storage Temperature | −30 to +70 °C |
| Heading Accuracy (Static) | 1° RMS |
| Heading Accuracy (Dynamic, up to ±30° pitch/roll) | 2° RMS |
| Heading Resolution | 0.1° |
| Heading Update Rate | 10 Hz (NMEA 0183), up to 20 Hz (NMEA 2000®) |
| Rate of Turn Range | 0–70°/s |
| Rate of Turn Accuracy | ±1°/s |
| Pitch/Roll Range | ±50° |
| Static Pitch/Roll Accuracy | <1° RMS |
| Dynamic Pitch/Roll Accuracy | <3° RMS |
| Pitch/Roll Resolution | 0.1° |
| Pitch/Roll Update Rate | 2 Hz (NMEA 0183), up to 20 Hz (NMEA 2000®) |
| NMEA 2000® Load Equivalency Number (LEN) | 1 |
| Certifications | CE, RoHS, IEC 60945, IPX6 |
| Brand | AIRMAR |
|---|---|
| Origin | USA |
| Model | M192 |
| Beam Width | Narrow |
| Transducer Array | Ceramic Element Array |
| Operating Frequencies | 15 kHz (wideband), 24 kHz, 28 kHz, 30 kHz, 33 kHz, 38 kHz, 33 & 200 kHz (dual-frequency wideband) |
| Housing Material | SEALCAST™ Polyurethane |
| Encapsulation | Seamless, Impact-Resistant, Cut- and Abrasion-Resistant |
| Mounting Options | Tank-Mounted or Portable Installation |
| Xducer ID® Technology | Yes |
| Cable Type | C-43 Shielded Twisted Pair (2–14 AWG), Braided Shield, Black Neoprene Jacket, Ø10 mm |
| Standard Cable Length | 10 m (max. 40 m) |
| Weight | 7.3–8.0 kg (varies with cable length and configuration) |
| Compliance | CE, RoHS, FCC Part 15, EN 60945 (Marine Electronic Equipment) |
| Brand | AIRMAR |
|---|---|
| Origin | USA |
| Interface Standard | NMEA 0183 |
| Connector Type | 9-pin male (AIRMAR side) / 8-pin female (host side) |
| Customizable Termination | RS232 / RS422 / RS485 |
| Available Lengths | 10 m |
| Brand | AIRMAR |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Protocol | NMEA 0183 v3.01 |
| Baud Rate | 4800 bps |
| Interface | USB 2.0 (Type-A), RS-422/RS-232 compatible via internal level-shifting circuitry |
| Operating Temperature | –20 °C to +70 °C |
| Enclosure | IP65-rated ruggedized ABS housing |
| Certifications | FCC Part 15 Class B, CE, RoHS compliant |
| Power Supply | Bus-powered via USB (5 V ±5 %, <100 mA) |
| Latency | <15 ms typical end-to-end |
| Data Buffer | 4 kB FIFO with overflow protection |
| Brand | Airmar |
|---|---|
| Origin | USA |
| Model | SS175HW |
| Operating Frequency Range | 150–250 kHz |
| Beam Width | Fixed 25° |
| Output Power | 1000 W |
| Housing Material | Stainless Steel |
| Mounting Type | Low-Profile Through-Hull |
| Transducer Window | Polyurethane |
| Maximum Hull Angle | 28° |
| Cable Length | 10 m |
| Integrated Temperature Sensor | Yes |
| Weight | 2.7 kg |
| Required Hull Cutout Diameter | 98 mm |
| Shaft Length | 118 mm |
| Compatible Hull Materials | Fiberglass, Wood, Aluminum, Stainless Steel |
| Vessel Length Limit | Up to 8 m |
| Xducer ID® Technology | Yes |
| Total Bandwidth | 100 kHz |
| Brand | Airmar |
|---|---|
| Origin | USA |
| Model | ST800 |
| Output | NMEA 2000® or Analog (optional) |
| Speed Range | 2–45 knots (2–52 MPH) |
| Temperature Accuracy | ±0.5°C |
| Operating Temperature | −10°C to +40°C |
| Housing Options | Plastic (P217/P314), Bronze (B119/B21), Stainless Steel |
| Hull Tilt Limit | ≤22° |
| Sampling Interval | 1 s |
| Pressure Rating | 3 m |
| Pulse Frequency | 17,000 p/nm (4.8 Hz per knot) |
| Supply Voltage | 9–16 VDC |
| Current Draw | <200 mA |
| NMEA 2000 LEN | 2 |
| Compliance | IEC 60945 |
| Brand | Airmar |
|---|---|
| Origin | USA |
| Model | ST850 |
| Output | NMEA 2000® or Analog (selectable) |
| Speed Range | 2–45 knots (2–52 MPH) |
| Temperature Accuracy | ±0.5°C |
| Operating Temp | −10°C to +40°C |
| Sampling Interval | 1 s |
| Pressure Rating | 3 m |
| Transducer Window Material | Polyurethane |
| Hull Tilt Limit | ≤22° |
| Pulse Frequency | 17,000 p/nm (4.8 Hz per knot) |
| Supply Voltage | 9–16 VDC |
| Current Draw | <200 mA |
| NMEA 2000 LEN | 2 |
| Compliance | IEC 60945 |
| Weight (Plastic/Bronze/Stainless) | 0.7 / 1.3 / 1.6 kg |
| Standard Cables | 6 m NMEA 2000, 9 m Analog |
| Brand | AIRMAR |
|---|---|
| Origin | USA |
| Model | TM275LHW |
| Power Output | 1000 W |
| Operating Frequency Bands | Low Band 42–65 kHz (beam width 25°–16°), High Wideband 150–250 kHz (constant 25° beam width) |
| Max Depth Range | 914 m (low band), 152 m (high wideband) |
| Beam Mounting Angle Adjustment | 3°–21° |
| Housing Material | SEALCAST™ seamless polyurethane encapsulation |
| Mounting Type | Transom-mount stainless steel bracket |
| Sensor Weight | 4 kg |
| Compatible Hull Types | All hull materials (fiberglass, aluminum, wood, composites) |
| Hull Length Requirement | ≥10 m |
| Temperature Sensor | Integrated fast-response thermistor |
| Total Frequency Span | 123 kHz |
| Brand | Airmar |
|---|---|
| Origin | USA |
| Model | UST800 |
| Speed Range | 0.1–50 knots |
| Operating Frequency | 4.5 MHz |
| Pulse Repetition Frequency | 0.5–12 kHz (adaptive) |
| Temperature Range | −4 to 40 °C |
| Output Protocols | NMEA 0183, NMEA 2000® |
| Power Supply | 9–16 VDC, avg. 125 mA @12 VDC |
| Housing Material | Plastic / Bronze / Stainless Steel |
| Housing Diameter | 51 mm |
| Weight | 1.4–1.8 kg |
| Compliance | NMEA 2000® Class B Device, EN 60945, EN 60529 IP67 (when installed) |
| Brand | Airmar |
|---|---|
| Origin | USA |
| Model | UST850 |
| Output Protocols | NMEA 0183, NMEA 2000® |
| Speed Range | 0.1–50 knots |
| Operating Temperature | −4 to 40 °C |
| Transmit Frequency | 4.5 MHz |
| Pulse Repetition Frequency | 0.5–12 kHz (adaptive) |
| Supply Voltage | 9–16 VDC |
| Average Current Draw | 125 mA @ 12 VDC |
| Housing Material | Plastic / Bronze / Stainless Steel |
| Through-Hull Diameter | 51 mm |
| Weight | 1.4 kg (plastic), 1.8 kg (bronze) |
| Brand | AirMetrics |
|---|---|
| Origin | USA |
| Model | MiniVol TAS |
| Flow Range | 0–10 L/min |
| Pressure Capability | >30,000 Pa |
| Flow Stability | ±5% |
| Max Flow Error | ±5% |
| Continuous Operation Time at Max Flow & Backpressure | 60 h |
| Dimensions (Sampler) | 25.4 × 30.5 × 17.8 cm |
| Weight (Fully Configured) | 4.45 kg |
| Battery | 14.8 V / 118 Wh Li-ion (≥60 h runtime, 5 h recharge) |
| Filter Format | 47 mm cassette (EPA FRM-compliant) |
| Inlet Type | EPA FRM-designated PM₁₀ or PM₂.₅ cyclonic separator |
| Power Options | AC/DC adapter (100–240 VAC, 47–63 Hz) or solar-compatible |
| Brand | AirPhoton |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Airphoton AeroExplorer |
| Pricing | Available Upon Request |
| Brand | AirPhoton |
|---|---|
| Origin | USA |
| Model | IN102 |
| Wavelengths | 450 nm, 532 nm, 632 nm |
| Scattering Angle Range | 7°–90° (forward), 90°–170° (backward) |
| Standard Measurement Range | 0.0–3,000 Mm⁻¹ |
| Extended Range | up to 20,000 Mm⁻¹ (user-adjustable) |
| Detection Limit (60-s avg) | Forward < 0.15 Mm⁻¹, Backward < 0.06 Mm⁻¹ |
| Sensitivity | < 10⁻⁷ m⁻¹ |
| Particle Size Coverage | PM₁ to PM₁₀ |
| Flow Control | Motorized variable-speed fan, 4-step programmable flow cycling |
| Environmental Sensors | Integrated temperature, relative humidity, and pressure sensors |
| Data Storage | 4 GB SD card |
| Communication Interface | RS485 (optional) |
| Power | 15 W @ 120 VAC |
| Operating Temperature | −30 °C to +45 °C |
| Dimensions | 9″ × 10″ × 24″ (22.9 × 25.4 × 61.0 cm) |
| Weight | 6.8 kg |
| Clean Air Reference System | CR100 (HEPA-filtered zero-air generator, compatible with IN101/IN102) |
| Filter Cartridge Module | FC10 (8-slot, 3″ × 6″ × 1.25″, ~0.6 kg) |
| Brand | AirPhoton |
|---|---|
| Origin | USA |
| Model | IN101 |
| Wavelengths | 450 nm, 532 nm, 632 nm |
| Scattering Angle Range | 7°–90° (forward) and 90°–170° (backward) |
| Total Scattering | Forward + Backward |
| Standard Measurement Range | 0.0–3,000 Mm⁻¹ |
| Extended Range | up to 20,000 Mm⁻¹ (optional) |
| Detection Limit (60-sec avg) | Forward < 0.15 Mm⁻¹, Backward < 0.06 Mm⁻¹ |
| Sensitivity | <1×10⁻⁷ m⁻¹ |
| Integrated Sensors | Temperature, Relative Humidity, Barometric Pressure |
| Data Storage | 4 GB SD card |
| Communication | RS485 (optional) |
| Power | 15 W @ 120 VAC |
| Light Source | High-stability LEDs |
| Operating Temperature | −30 °C to +45 °C |
| Dimensions | 22.9 cm × 25.4 cm × 61.0 cm (9″ × 10″ × 24″) |
| Weight | 6.7 kg |
| Optional Accessories | CR100 Clean Air System, FC10 8-Slot Filter Cartridge, AeroExplorer Sampling Station (SS5e/SS5i) |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AirScanner |
| Price Range | USD 68,000–136,000 (FOB) |
| Pollutants Measured | O₃, NO/NO₂, CO, SO₂, CO₂, VOCs, PM₁₀, PM₂.₅ |
| Measurement Principles | UV Photometry (O₃, SO₂), Chemiluminescence (NO/NO₂), NDIR (CO, CO₂), PID (VOCs), β-Attenuation or Optical Scattering (PM) |
| Environmental Parameters | Temperature, Relative Humidity, Wind Speed & Direction, Ambient Noise, Atmospheric Pressure |
| Data Connectivity | GSM/GPRS, Ethernet (LAN/WLAN), RS-232 |
| Enclosure Rating | IP65 |
| Operating Temperature Range | −20 °C to +50 °C |
| Power Supply | 230 V AC ±10%, 50/60 Hz or Solar/Battery Hybrid Option |
| Brand | AIRSENSE |
|---|---|
| Origin | Germany |
| Instrument Type | Online |
| Detection Principle | Hybrid Sensor Array (Metal Oxide Semiconductor, Photoionization Detector, Electrochemical Sensors) |
| Accuracy | ±2% FS |
| Flow Rate Range | 10–400 mL/min |
| Response Time | <1 s |
| Operating Temperature | −30°C to +100°C |
| Operating Humidity | 0–90% RH |
| Sensor Configuration | 4× MOS, 1× PID, 2–4× electrochemical sensors |
| Output Parameters | H₂S, NH₃, TVOC, user-selectable target odorants (1–2), and dimensionless odor unit (OU) concentration |
| Communication Interfaces | WiFi, GSM, GPRS, 3G, Ethernet |
| Data Management | Cloud database, local LAN, or open-network deployment |
| Compliance Ready | Designed for integration into GLP/GMP- and ISO 16000-compliant environmental monitoring workflows |
| Brand | AIRSENSE |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | GDA-F |
| Weight | 2 kg |
| Sampling Method | Automatic Continuous Sampling |
| Operating Temperature | Ambient (15–30 °C) |
| Detection Range | ppb to ppm |
| Target Gases | Cl₂, HF, HCN, chlorobenzene, toluene, and other fumigants/volatile organic compounds (VOCs) |
| Brand | AIRSENSE |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GDA-FR |
| Pricing | Available Upon Request |
| Brand | AIRSENSE |
|---|---|
| Origin | Germany |
| Model | GDA-FR |
| Detection Technologies | IMS, PID, MOS, EC |
| Sensor Channels | 8 independent parallel channels |
| Library Size | >300 calibrated chemical signatures |
| Response Time | <2 s (typical), ≤60 s (full quantification) |
| Detection Range | Sub-ppb to ppm level depending on analyte |
| Power | Rechargeable Li-ion battery, >8 h continuous operation |
| Compliance | CE, RoHS, ATEX Zone 2/22 (optional), IEC 61508 SIL2-ready architecture |
| Operating Temperature | −10 °C to +50 °C |
| Ingress Protection | IP65 |
| Brand | AIRSENSE |
|---|---|
| Origin | Germany |
| Instrument Type | Portable |
| Detection Principle | Hybrid IMS/PID/MOS/EC Sensor Fusion |
| Core Configuration | Multi-Channel VOC & Inorganic Gas Detector |
| Operating Temperature | −30 °C to 50 °C |
| Relative Humidity Range | 5–95% RH (non-condensing) |
| Power Supply | Rechargeable Li-ion Battery (30 W, 8 h runtime) |
| Weight | 4.2 kg |
| Sample Introduction | Integrated Auto-Sampling Pump with Continuous Gas Flow |
| Cycle Time | 5 min |
| Response Time | 2–60 s |
| Detection Library | >300 Pre-Calibrated Compounds (VOCs, Inorganic Gases, Electronic Specialty Gases), Expandable |
| Data Interfaces | RS-232, Ethernet, Wireless Transmission |
| Software | WinMuser GDA Suite |
| Heating Module | Integrated IR Heater for Solid/Surface Residue Volatilization |
| Alarm Logic | Template-Based Pattern Recognition with User-Configurable Thresholds |
| Brand | AIRSENSE |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | GDA-X |
| Pricing | Upon Request |
| Brand | AIRSENSE |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | M-IR |
| Pricing | Available Upon Request |
| Brand | AIRSENSE |
|---|---|
| Origin | Germany |
| Model | Mobile-IR |
| Design | Integrated ATR-based Portable FTIR System |
| Spectral Range | 4000–600 cm⁻¹ (typical) |
| Spectral Resolution | ≤4 cm⁻¹ (user-selectable) |
| Library | >14,000 reference spectra of hazardous, industrial, and environmental chemicals |
| Compliance | IP67-rated enclosure |
| Data Interface | Wi-Fi, USB, Bluetooth |
| Operating System | Embedded Linux with OPUS/Mentor software suite |
| Display | High-brightness capacitive touchscreen (≥10.1″) |
| Power | Rechargeable Li-ion battery (≥6 h continuous operation) |
| Weight | <5.2 kg |
| Dimensions | 320 × 240 × 180 mm (L×W×H) |
| Brand | AIRSENSE |
|---|---|
| Origin | Germany |
| Model | Olfosense |
| Instrument Type | Online |
| Detection Principle | Hybrid Sensor Array (Metal Oxide Semiconductor, Photoionization Detector, Electrochemical Sensors) |
| Accuracy | ±1–2% |
| Flow Rate Range | 10–400 mL/min |
| Response Time | <1 second |
| Operating Temperature | −30°C to +100°C |
| Operating Humidity | 0–90% RH |
| Sensor Configuration | 4× MOS, 1× PID, 2–4× electrochemical sensors |
| Output Parameters | H₂S, NH₃, TVOC concentrations, user-selectable odorant(s) (1–2), and dimensionless odor unit (OU) values |
| Connectivity | WiFi/GSM/GPRS/3G |
| Data Integration | Open API, Modbus TCP/RTU, MQTT |
| Compliance | Designed for EN 13725-compliant odor assessment workflows |
| Brand | AIRSENSE |
|---|---|
| Origin | Germany |
| Model | PEN 3.5 |
| Sensor Array | 10 metal oxide semiconductor (MOS) sensors |
| Sensor Volume | 1.8 mL |
| Operating Temperature | 110 °C (sensor tube) |
| Response Time | < 1 s |
| Measurement Cycle | ~60 s (20 s exposure + 40 s recovery) |
| Sampling Flow Rate | 10–400 mL/min (integrated mass flow control) |
| Built-in Pumps | 2 (sample + zero air) |
| Zero Air Source | Activated charcoal-filtered ambient air or zero-air generator |
| Display | Integrated LCD panel |
| Interface | USB and/or RS232 |
| Digital I/O | TTL and digital signal ports |
| Operating Ambient | 0–40 °C, 5–95% RH (non-condensing) |
| Power | 30 W, 110–230 V AC or optional 12 V DC |
| Weight | 2.3 kg |
| Dimensions | 255 × 190 × 92 mm |
| Safety Compliance | IEC 61010-1 |
| Detection Limits | 0.1–5 ppm (general VOCs), 0.1 ppm (H₂S), 1 ppm (benzene) |
| Software Platform | WinMuster v5.x (supports PCA, LDA, DFA, K-NN, PLS, BP-ANN) |
| Data Integrity | Audit-trail enabled |
| Brand | AIRSENSE |
|---|---|
| Origin | Germany |
| Model | PEN3 |
| Sensor Array | 10 metal oxide semiconductor (MOS) sensors |
| Sensor Volume | 1.8 mL |
| Operating Temperature | 110 °C (sensor tube) |
| Response Time | <1 s |
| Measurement Cycle | ~60 s (20 s exposure + 40 s recovery) |
| Sampling Flow Rate | 10–400 mL/min (internally regulated) |
| Sampling System | Dual built-in pumps (sample + zero air) |
| Zero Air Source | Activated charcoal-filtered ambient air or zero-air generator |
| Display | Integrated LCD screen |
| Interface | USB and/or RS232 |
| Digital I/O | TTL & digital signal ports |
| Operating Ambient | 0–40 °C, 5–95% RH (non-condensing) |
| Power | 30 W, 110–230 V AC or optional 12 V DC |
| Weight | 2.3 kg |
| Dimensions | 255 × 190 × 92 mm |
| Safety Compliance | IEC 61010-1 |
| Detection Limit | 0.1–5 ppm (general VOCs), 0.1 ppm (H₂S), 1 ppm (benzene) |
| Software | WinMuster v5.x (PCA, LDA, DFA, K-NN, PLS, BP-ANN) |
| OS Compatibility | Windows XP and later |
| Calibration Stability | Automated drift compensation over 12 months |
| Warranty | 1 year |
| Brand | AIRSENSE |
|---|---|
| Origin | Germany |
| Model | PEN3-meteo |
| Sensor Array | 10 MOS metal oxide sensors |
| Odor Unit Quantification | OU/m³ per EN 13725 |
| Data Logging | Integrated DCR computer (Mini-ITX, 40 GB HDD, 512 MB RAM, Windows XP) |
| Connectivity | Wi-Fi + optional GSM/GPRS module for SMS alerts |
| Meteorological Integration | Co-located anemometer and wind vane with real-time digital output |
| Compliance | EN 13725:2003 certified odor quantification methodology |
| Brand | AIRSENSE |
|---|---|
| Origin | Germany |
| Model | meteo |
| Compliance | EN 13725 |
| Output Unit | Odor Units per cubic meter (OU/m³) |
| Sensor Array | 10 MOS (Metal Oxide Semiconductor) sensors |
| Data Acquisition | Continuous, 24/7 |
| Communication | Wi-Fi + optional GSM/GPRS |
| Meteorological Integration | Integrated anemometer & wind vane |
| Software Algorithms | PCA, PLS regression, Mahalanobis & Euclidean distance analysis |
| Calibration Reference | EN 13725-compliant dynamic olfactometry |
| Brand | AIRSENSE |
|---|---|
| Origin | Germany |
| Model | PEN3-meteo |
| Compliance | EN 13725:2003 |
| Detection Principle | Metal Oxide Semiconductor (MOS) Sensor Array with Multivariate Pattern Recognition |
| Output Unit | Odor Units per cubic meter (OU/m³) |
| Data Transmission | Wi-Fi + Optional GSM/GPRS |
| Meteorological Integration | Integrated anemometer and wind vane |
| Operating Mode | Fully Automated, Unattended 24/7 Monitoring |
| Software Algorithms | PCA, PLS, Mahalanobis Distance, Euclidean Distance |
| Sensor Configuration | 10-channel MOS sensor array |