| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Small-Diameter Cylindrical Soil Auger |
| Pricing | Available Upon Request |
| Origin | France |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SmartChem 200 |
| Price | €60,000 |
| Power Requirement | 90–250 VAC, 47–63 Hz, 300 W |
| Water Consumption | 2 mL per test |
| Operating Temperature | 18–30 °C |
| Relative Humidity | 20–85 % RH |
| Dimensions (H×W×D) | 42 × 65 × 100 cm |
| Weight | 65 kg |
| Sample Capacity | 126 positions across 5 racks |
| Sample Tube Size | up to 16 mm × 100 mm |
| Minimum Sample Volume | 3.0 µL (1 µL increment) |
| Reagent Volume | 3.0–300 µL (1 µL increment) |
| Dilution Factor | up to 100× |
| Reaction Cuvettes | 60-position rotating reusable disc, temperature-controlled at 37.0 ± 0.1 °C |
| Optical System | Dual-beam photometer with 8 narrow-band interference filters (420–880 nm), 6 V/10 W halogen lamp, 10 mm pathlength, linear range 0.001–2.500 Abs, resolution 0.0001 Abs |
| Throughput | up to 200 tests/hour |
| Detection Principle | Direct spectrophotometric measurement in discrete reaction cuvettes |
| Origin | Italy |
|---|---|
| Manufacturer | AMS Group |
| Instrument Type | Laboratory-Based Discrete Chemistry Analyzer |
| Optical Range | 420–880 nm |
| Linear Absorbance Range | 0.001–2.500 AUFS |
| Resolution | 0.0001 Abs |
| Filter Wheel | 9 + 1 Blind Position |
| Sample Capacity | Up to 126 Positions (5 Racks) |
| Reagent Positions | 16 Total (10 Refrigerated, 6 Ambient) |
| Dispense Volume | 3–450 µL |
| Reaction Temperature Control | 37 °C ±0.1 °C |
| Dimensions (H×W×L) | 42 × 65 × 100 cm |
| Weight | 65 kg |
| Power | 90–250 VAC, 47/63 Hz, 300 W |
| Water Consumption | 2 mL per test |
| Compliance | ASTM, ISO, AOAC, US EPA Methods (incl. EPA 353.2), AFNOR, COFRAC, BATF |
| Brand | AMS |
|---|---|
| Origin | Italy |
| Model | Stack Gas2001 (600/ISS1400K) |
| Instrument Type | Heated Flue Gas Sampling Probe |
| Flow Accuracy | ±2% of full scale |
| Probe Length Options | 350 mm / 750 mm |
| Heating Element | Integrated, temperature-controlled |
| Filter | In-probe heated particulate filter (ceramic or sintered metal, typical operating temp: 180–200 °C) |
| Power Supply | Internal 14 Ah sealed lead-acid battery (rechargeable, designed for ≥500 cycles) |
| Sampling Line Assembly | Dual-layer polyethylene tubing (1.25 m length), integrated cooling jacket + electronic control unit (P/N 2100152) |
| Optional Integration | Compatible with DiluGas™ dynamic dilution system (dual-input interface) |
| Brand | AMT |
|---|---|
| Origin | Germany |
| Model | AMT-CO₂ |
| Measurement Principle | Optical NDIR (Single-Beam, Dual-Wavelength) |
| Range Options | 15 / 50 / 340 mg/L (customizable) |
| Accuracy | ±2% of reading (5–15 mg/L range) |
| Housing Material | Titanium |
| Dimensions | Ø33 mm × 225 mm |
| Operating Depth | Up to 1000 m |
| Power Supply | 12–30 VDC (digital/voltage output) |
| Power Consumption | <0.5 W |
| Warm-up Time | <12 s (initial stabilization), <2 min (optimal accuracy) |
| Output Options | 4–20 mA, 0–5 V, RS485 |
| Temperature Compensation | Internal, automatic |
| Humidity Compensation | Internal, automatic |
| Operating Temperature | 0–60 °C |
| Immersion Capability | Fully submersible in water or air |
| Brand | AMT |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AMT-CTD/O2 |
| Price | Upon Request |
| Brand | AMT |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AMT-EC7 |
| Instrument Type | Online |
| Conductivity Ranges | 0–1 mS/cm |
| Outer Diameter | 40 mm |
| Total Length | ~270 mm |
| Weight | ~300 g |
| Housing Material | Titanium |
| Pressure Rating | 6000 m (6000 dbar) |
| Output Signal | 0–2.5 V DC or 0–5 V DC |
| Supply Voltage | 9–18 V DC |
| Connector | SubConn wet-mateable underwater connector |
| Measurement Principle | Seven-electrode AC conductivity with quartz-glass sensing tube |
| Channels | 4 measurement electrodes + 1 excitation + 2 guard/ground electrodes |
| Brand | AMT |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AMT-H2 |
| Pricing | Upon Request |
| Brand | AMT |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AMT-H2S |
| Price | Upon Request |
| Measurement Principle | Amperometric (Clark-type, 3-electrode) |
| Power Supply | 9–30 VDC |
| Output Signal | 0–5 VDC |
| Dimensions | Ø24 mm × 235 mm |
| Connector | SUBCONN BH-4-MP (optional alternatives available) |
| Warm-up Time | 5–15 min |
| Electrolyte Consumption | Low |
| Measurement Ranges | Type I: 0.05–10 mg/L H₂S |
| Type II | 0.5–50 mg/L H₂S |
| Type III | 0.01–3 mg/L H₂S |
| Accuracy | ±2% of reading |
| Operating Temperature | 0–30 °C |
| pH Range | 0–8.5 |
| Response Time (t₉₀) | <200 ms |
| Typical Service Life | 5–9 months |
| Pressure Rating | >10 bar |
| Brand | AMT |
|---|---|
| Origin | Germany |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | AMT-O2 |
| Pricing | Upon Request |
| Brand | AMT |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AMT-O3 |
| Pricing | Upon Request |
| Brand | AMT |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AMT-ORP |
| Price | Upon Request |
| Measurement Range | ±2000 mV |
| Resolution | 0.1 mV |
| Accuracy | ±2 mV |
| Power Supply | 9.5–18 VDC |
| Output Signal | 0–5 VDC |
| Dimensions | Ø30 mm × 250 mm |
| Pressure Rating | 600 dbar |
| Brand | AMT |
|---|---|
| Origin | Germany |
| Model | AMT-pH |
| Instrument Type | Online |
| pH Range | 2–11 (standard) |
| Resolution | 0.01 pH |
| Accuracy | ±0.05 pH |
| Supply Voltage | 9.5–18 VDC |
| Output Signal | 0–5 VDC |
| Dimensions | Ø30 mm × 250 mm |
| Pressure Rating | 600 dbar |
| Electrode Integration | Integrated glass + reference electrode in single housing |
| Membrane Design | Dual-junction diaphragm |
| Operating Depth | Up to 6000 m |
| Temperature Sensor | Not integrated |
| Compliance | Designed for ISO 10523, ASTM D1293, and marine GLP-compliant in-situ deployments |
| Brand | AMT (Germany) |
|---|---|
| Origin | Germany |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Instrument Type | Online |
| Measurement Principle | Electrochemical (Polarographic Membrane-Type) |
| Accuracy | ±2% of reading |
| Power Supply | 9–30 VDC |
| Output Signal | 0–5 VDC |
| Dimensions | Ø25 mm × 240 mm |
| Air Weight | 260 g |
| Interface | SUBCONN BH-4-MP |
| Housing Material | Titanium & POM |
| Pressure Rating | 200 dbar (2000 m) or 600 dbar (6000 m) |
| Response Time (t₆₃%) | ~10 s |
| Dual-Membrane Configuration | Inner sensing membrane + outer protective membrane |
| Polarization Power Source | Integrated Li-ion battery (auto-disengaged when external power is applied) |
| Cable | Multi-core 4-wire marine-grade cable |
| Environmental Compatibility | Seawater, freshwater lakes & rivers |
| Brand | AMT |
|---|---|
| Origin | Germany |
| Distributor Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Not Specified |
| Price | Upon Request |
| Dimensions | 220 mm × 160 mm × 250 mm |
| Power Supply | 230 V AC |
| Flow Rate | 10–12 mL/min |
| Dissolved Oxygen Range | 0.4 µg/L – 9.95 mg/L |
| Accuracy | ±0.25% of reading |
| Response Time | ≤5 min |
| Deoxygenation Efficiency | Residual O₂ < 35 µg/L |
| Deaeration Protocol | 45-min purge followed by ~5-min equilibration |
| Calibration Reference Method | Winkler titration per DIN 38408-21 (modified) |
| Brand | AMT |
|---|---|
| Origin | Germany |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Imported |
| Model | AMT G200 Coulometric H₂S Sulfide Generator |
| Price | Upon Request |
| Concentration Range | 0.002–60.0 mg/L H₂S (0.062–1871 µmol/L H₂S) |
| Electrode Capacity | ≈350 mAh |
| Dimensions | 220 mm (L) × 160 mm (W) × 250 mm (H) |
| Accuracy | ±0.25% (amperometric probe) |
| Purge Time | ~45 min |
| First Concentration Transition | ~15–30 min |
| Concentration Step Response Time | 1 h per 10 steps (dependent on step magnitude and gas flow rate) |
| Repeatability | 99.78% (amperometric), 97.51% (methylene blue) |
| Dry-Run Tolerance | ~4 working days |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AMT |
| Pricing | Available Upon Request |
| Brand | AMT |
|---|---|
| Origin | Germany |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Imported |
| Model | MS08 |
| Pricing | Upon Request |
| Brand | AMT |
|---|---|
| Origin | Germany |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | pH |
| Price | Upon Request |
| Brand | AMT (Germany) |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AMT-H2S/Sulfide |
| Price | Upon Request |
| Brand | AMT |
|---|---|
| Origin | Germany |
| Model | AMT-H2O2 |
| Electrode Configuration | 3-electrode amperometric |
| Membrane Material | Silicone elastomer |
| Output Signal | 0–5 V DC proportional to partial pressure (0–400 Pa) |
| Measurement Range (Type I) | 0.02–10% w/w H₂O₂ |
| Accuracy | ±1% of full scale |
| Response Time (t₉₀) | 1–2 s |
| Operating Temperature | 0–30 °C |
| pH Range | 0–11 |
| Pressure Rating | >10 bar |
| Housing Material | Titanium |
| Typical Service Life | 5–9 months |
| Polarization Time | 5–15 min |
| Probe Replaceability | Yes |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AMT-CO2 |
| Pricing | Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AMT-H2O2 |
| Pricing | Available Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AMT-H2S |
| Pricing | Available Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | AMT-O3 |
| Pricing | Upon Request |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Type | Imported |
| Model | AnalogPlus™ Dissolved Oxygen Electrode |
| Pricing | Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Type | Imported |
| Model | AnalogPlus Ozone Electrode |
| Price | Upon Request |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | ASP-BB02-Y1101 |
| Instrument Type | Portable |
| Detection Target | Single Gas (CO₂) |
| Range | 0–5 %vol (0–50,000 ppm) |
| Resolution | 0.01 %vol |
| Repeatability | ±1 % of reading |
| Zero Drift | ±1 % FS/month |
| Span Drift | ±2 % FS/month |
| Linearity Error | ±2 % FS |
| Response Time (T90) | <60 s |
| Operating Temperature | −5 to +50 °C |
| IP Rating | IP65 |
| EMC Compliance | 2004/108/EC |
| Brand | Analox |
|---|---|
| Origin | United Kingdom |
| Model | Aspida O₂ |
| Instrument Type | Portable |
| Measurement Range | 0.1–25% O₂ (v/v) |
| Accuracy | ±0.0075% O₂ |
| Resolution | 0.1% O₂ |
| Repeatability | ±1% of reading |
| Zero Drift | <1% O₂ per month |
| Span Drift | <1% O₂ per month |
| Linearity Error | ±1% of full scale |
| Visual Indication | Green (normal), Amber (fault), Triple Red (alarm) |
| Audible Alarm | 95 dB @ 30 cm |
| Emergency Alarm | 110 dB @ 30 cm |
| Vibration Alert | Yes |
| T90 Response Time | <30 s |
| Operating Temperature | −5 °C to +50 °C |
| IP Rating | IP65 |
| Dimensions | 127 mm × 44 mm × 90 mm |
| Weight | 355 g |
| Power | Dual-mode — rechargeable Li-ion battery or two AA alkaline cells |
| Data Logging | Time-weighted average (TWA), STEL, peak hold |
| Compliance | ATEX II 2G Ex ib IIC T4 Gb, IECEx Ex ib IIC T4 Gb, UKCA, CE |
| Brand | Analox |
|---|---|
| Origin | United Kingdom |
| Model | Aspida O2 |
| Instrument Type | Portable |
| Sensor Range | 0.1–25% O₂ |
| Accuracy | ±0.0075% O₂ |
| Visual Alarm Indicators | 1× green (normal), 1× amber (fault), 3× red (alarm) |
| Audible Alarm | 95 dB @ 30 cm |
| Emergency Alarm | 110 dB @ 30 cm |
| Response Time (T90) | <30 s |
| Operating Temperature | −5 to +50 °C |
| IP Rating | IP65 |
| Dimensions | 127 × 44 × 90 mm |
| Weight | 355 g |
| Power | Dual-mode — rechargeable Li-ion battery or two standard AA alkaline cells |
| TWA Calculation | Yes |
| Vibration Alert | Yes |
| Multi-user Support | Up to 2 users with individual calibration & usage logs |