Environmental Monitoring Instruments
Filter
Showing 781–810 of 2621 results
| Brand | Bettersize |
|---|---|
| Origin | Liaoning, China |
| Manufacturer | Bettersize Instrument Co., Ltd. |
| Model | BTPM-AWS2 |
| Measurement Method | Membrane Gravimetry |
| Measured Parameters | PM10, PM2.5 |
| Measurement Range | 0–52 mg/m³ |
| Sampling Cycle | 24 h |
| Sampling Flow Rate | 1.05 L/min ±2% |
| LOD | 1 µg/m³ |
| Flow Stability | ≤±1% over 24 h |
| Balance Resolution | 0.01 mg (10 µg) or optional 0.001 mg (1 µg) |
| Temperature Control Range | 15–30 °C (adjustable, ±0.1 °C stability) |
| Humidity Control Range | 40–60 %RH (adjustable, ±3 %RH stability) |
| Vibration Isolation | Dual-Stage Quadruple-Level Isolation (4-level balance + 4-level chassis) |
| Electrostatic Neutralization | Ionizing air bar (non-radioactive, CE-compliant) |
| Sample Capacity (per cycle) | 200 × 47 mm filters / 100 × 90 mm filters / 60 × filter tips or quartz/ceramic filter tubes |
| Identification Systems | RFID (47/90 mm filters), QR Code (47/90 mm), Barcode (filter tips/tubes), Binary-coded positional encoding |
| Conditioning Time | 0–48 h programmable |
| Water Replenishment Interval | ≤30 days (closed-loop humidification system) |
| Power Supply | AC 220 V / 50 Hz, 2000 W |
| Compliance | HJ 618–2011, HJ 656–2013, HJ 836–2017, ISO 12103-1, ASTM D1856, USP <661>, GLP-aligned audit trail logging |
| Brand | Bettersize |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | BTPM-HS10 |
| Flow Rate | 16.67 L/min |
| Maximum Vacuum Pressure | 35 kPa |
| Flow Stability | <1% RSD |
| Maximum Flow Error | ±1% |
| Operational Lifetime at Max Flow & Backpressure | 6000 h |
| Filter Capacity | 10 × 47 mm |
| Sampling Duration per Filter | 1–99 h (programmable) |
| Data Storage | 4 GB SD card (≥10 years of operational logs) |
| Operating Temperature | −30 to +50 °C |
| Relative Humidity Range | 0–100% RH |
| Acoustic Noise Level | ≤53 dB(A) |
| Power Supply | AC 220 V / 50 Hz, 400 W |
| Optional Low-Temperature Module | Yes |
| Compliance | HJ 93–2013, HJ 656–2013, HJ 618–2011, Environmental Air Quality Monitoring Specification (Trial) |
| Brand | Bettersize |
|---|---|
| Origin | Liaoning, China |
| Manufacturer | Bettersize Instrument Co., Ltd. |
| Model | BTPM-MWS1 Constant Temperature & Humidity Weighing System |
| Measurement Method | Gravimetric Filter Weighing |
| Measured Parameters | PM₁₀ / PM₂.₅ / PM₁ |
| Measurement Range | 0–52 mg |
| Cycle Time | 24 h |
| Sampling Flow Rate | 1.0 L/min |
| LOD | 1 µg/m³ |
| Flow Stability | ±1% (not 100%) |
| Pre-conditioning Capacity | 60 × 47 mm filters / 36 × 90 mm filters / 30 filter tips or cartridges |
| Balance Resolution | 0.01 mg (0.001 mg optional) |
| Temperature Control Range | 15–30 °C (±0.5 °C) |
| Humidity Control Range | 40–60 %RH (±3 %RH) |
| Vibration Isolation | 4-stage active/passive damping platform |
| Electrostatic Neutralization | Ionizing air bar (non-radioactive, CE-compliant) |
| Power Supply | AC 220 V / 50 Hz, 2000 W |
| Operating Environment | 10–40 °C, 10–75 %RH |
| Data Interface | Wireless tablet integration with real-time logging and export |
| Brand | FPI (Fortune Photonics Instrumentation) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer | Yes |
| Country of Origin | China |
| Model | BFA-3000 |
| Application Mode | Portable & Online Dual-Mode |
| Depth Rating | Up to 200 m submersible |
| Measurement Principle | In vivo chlorophyll a fluorescence excitation with multi-wavelength LED array |
| Compliance | Designed for field-deployable water quality monitoring per ISO 10260, ASTM D3731, and EPA Method 445.0 (Chlorophyll a by in vivo fluorescence) |
| Data Output | Real-time spectral fluorescence response, taxonomic group quantification (e.g., Cyanobacteria, Diatoms, Green Algae, Cryptophytes), Chl-a concentration (µg/L), and vertical profile logging |
| Brand | BGI |
|---|---|
| Origin | USA |
| Model | Bios Defender 510 & 520 |
| Certification | ISO/IEC 17025 Accredited by NVLAP (NIST) |
| Operating Temperature Range | –20 °C to +50 °C |
| Display | Backlit LCD with Navigation Menu |
| Connectivity | RS-232 Serial Interface |
| Compliance | RoHS Directive 2011/65/EU |
| Flow Units | mL/min, L/min, cc/min, CFM |
| Data Logging | Up to 100+ readings with user-defined intervals (1–60 min) |
| Integrated Sensors | Built-in temperature sensor and pressure transducer (Defender 520 only) |
| Software | PC-based calibration data acquisition, curve plotting, report generation, and GLP-compliant audit trail export |
| Brand | BGI |
|---|---|
| Origin | USA |
| Model | deltaCal DC1 & tetraCal TC5 |
| Flow Range (deltaCal) | 1.5–19.5 L/min |
| Flow Range (tetraCal) | 0.1–30.0 L/min |
| Operating Temperature | −30 °C to +55 °C |
| Barometric Pressure Range | 400–800 mmHg (534–1066 hPa) |
| Temperature Measurement Range | −40 °C to +55 °C |
| Power | 4×AA batteries (20 hr) or universal 120/240 VAC adapter |
| Certifications | NIST-traceable calibration, ISO 9001 certified, compliant with U.S. EPA PM2.5/PM10 field verification requirements |
| Brand | BGI |
|---|---|
| Origin | USA |
| Model | PQ167HA |
| Operating Altitude | up to 15,000 ft (4,572 m) |
| Flow Rate | 5.0 L/min (±2% accuracy) |
| Sampling Duration | 24 h on internal DC battery |
| Particle Size Cutpoints | TSP, PM10, PM4.0, PM2.5, PM1.0 |
| Filter Format | 47 mm diameter membrane |
| Compliance | U.S. EPA Federal Reference Method (FRM) for PM2.5 |
| Sampling Head | BGI miniPM with integrated water separator |
| Power Options | Internal rechargeable DC battery + AC adapter |
| Brand | BGI |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PQ200 |
| Pricing | Upon Request |
| Brand | BGI |
|---|---|
| Origin | USA |
| Model | VSCC |
| Regulatory Designation | U.S. EPA Reference Method (RFPS-0498-116) |
| EPA EQPM Certification | EQPM-0202-1428 (upgraded to Reference Method, October 17, 2006) |
| Cutpoint | 2.5 µm aerodynamic diameter (D₅₀) |
| Operating Principle | Inertial cyclonic separation |
| Maintenance Interval | Up to 30 days continuous 24-hr sampling before cleaning |
| Cleaning Method | Dry, tool-free, field-cleanable with lint-free cloth and deionized water |
| Compatibility | Direct drop-in replacement for WINS impactor-based FRM samplers (e.g., Thermo Fisher Partisol 2025, Teledyne API models, Met One BAM-1020, etc.) |
| Brand | Bigdipper |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HBD5-OPA4110TP |
| Measurement Principle | Optical Light Scattering (Nephelometric) |
| Range Options | 0.003–33 mg/m³ (100×), 0.03–330 mg/m³ (10×), 0.8–32,000 g/m³ (X), or 15×0.02–166 g/m³ (15×) |
| Accuracy | ±2% or ±0.8 g/m³ (water fog reference), whichever is greater |
| Calibration | Dual-point 2KS calibration |
| Response Time | ≤1 s |
| Operating Temperature | 0–70 °C |
| Power Supply | NiCd ×8 battery pack (1 h continuous operation) |
| Dimensions (Meter) | 98 × 150 × 30 mm |
| Sensor Dimensions | Ø24 × 360 mm |
| Weight | 0.7 kg |
| Display | 16×2 LCD with backlight |
| Data Logging | 24 records per calibration table (up to 8 tables) |
| Communication | RS-232 / RS-485 serial interface |
| Compliance | Designed for field-deployable environmental and industrial aerosol monitoring per ISO 7706 (airborne oil mist), ASTM D6340 (aerosol mass concentration), and EPA Method 9031 (nephelometric turbidity correlation) |
| Brand | Bigdipper |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Type | Portable |
| Detection Principle | Multi-sensor Fusion (Electrochemical, PID, NDIR, Catalytic Combustion, Semiconductor, Metal Oxide) |
| Accuracy | ±1–2% of reading (typ.) |
| Flow Rate | 0.1 L/min |
| Response Time | <1 min (T90) |
| Operating Temperature | −10 °C to +60 °C |
| Operating Humidity | 10–90% RH (non-condensing) |
| Dimensions | 400 × 300 × 200 mm |
| Weight | 4.5 kg |
| Power Supply | Rechargeable 12 V battery |
| Sensor Channels | Configurable from 4 to 23 gas-specific sensors |
| Compliance | Designed per GB 14554–1993 “Emission Standard of Odorous Pollutants” |
| Data Interface | RS232 / RS485 |
| Calibration | Dual-standard (DKA) and single-point inert gas zeroing |
| Cross-interference Compensation | Neural network-based real-time correction algorithm |
| Brand | Bigdipper |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Bigdipper Instruments Co., Ltd. |
| Model | pAir2000-EFF-A1 |
| Instrument Type | Portable |
| Detection Principle | Multi-sensor array (electrochemical, metal oxide semiconductor, photoionization detection/PID) |
| Accuracy | ±1% of reading |
| Response Time | < 10 ms |
| Operating Temperature | -10°C to 60°C |
| Operating Humidity | 10–90% RH (non-condensing) |
| Gas Measurement Range | NH₃ (0.5–200 ppm), H₂S (0.3–100 ppm), ODU (0–10,000, unitless) |
| Resolution | 0.01 ppm (NH₃, H₂S), 0.1% FS (full scale) |
| Long-term Stability | ±10% per year |
| Power Supply | 12 V rechargeable battery |
| Dimensions | 400 × 300 × 200 mm |
| Weight | 4.5 kg |
| Compliance | NY/T 388–1999 (China Agricultural Standard for Odor Concentration Determination) |
| Brand | Bigdipper |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | pAir2000-EFF-D |
| Instrument Type | Portable |
| Detection Principles | Electrochemical, Metal Oxide Semiconductor (MOS), Photoionization Detector (PID), Non-Dispersive Infrared (NDIR), UV-Vis Spectrophotometry |
| Accuracy | ±1–2% of reading |
| Flow Rate | 0.1 L/min |
| Response Time (T90) | <3 minutes |
| Operating Temperature | −10 °C to +60 °C |
| Operating Humidity | 10–90% RH (non-condensing) |
| Power Supply | 12 V rechargeable battery |
| Dimensions | 400 × 300 × 200 mm |
| Weight | 4.5 kg |
| Sensor Resolution | 0.1% FS |
| Long-Term Stability | ±10% per year |
| Display | 4×16-character LCD |
| Communication Interfaces | RS232 / RS485 |
| Calibration Options | Single-point inert gas zeroing, dual-standard (DKA) calibration with certified reference gases or traceable surrogates |
| Cross-Interference Compensation | Neural network-based multi-gas interference correction algorithm |
| Brand | Bigdipper |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Model | wAir2000SR-5s01 (CO, CO₂, NH₃, Toxic Gas, O₂) |
| Detection Parameters | CO (0.1–500/1000 ppm), CO₂ (0–1/5 %v/v), NH₃ (0.1–100 ppm), Toxic Gas (0.1–1000 ppm), O₂ (0–30 %v/v) |
| Temperature Range | −40 to +100 °C |
| Humidity Range | 0–99 %RH |
| Accuracy | ±2% R (CO, O₂), ±1% R (CO₂), ±10% R (NH₃), ±5% R (Tox) |
| Repeatability | Specified per gas |
| Display | 4×16 Character LCD |
| Communication | RS232/RS485 Dual-Mode Serial Interface |
| Power Supply | 220 V AC, <10 W |
| Enclosure Rating | NEMA 4 / IP56 |
| Dimensions | 300 × 500 × 250 mm (W×H×D) |
| Data Logging | 24 Groups (Non-Volatile Memory) |
| Warm-up Time | 3–5 min |
| Mounting | Wall-Mounted Fixed Installation |
| Brand | Bigdipper |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | WBD5-CWA-MG02 |
| Detection Principle | Electrochemical & Metal Oxide Semiconductor (MOS) Sensor Array |
| Target Analytes | Organophosphorus agents (GA, GB, GD, GF, VX, VR, etc.), Mustard gas (HD), Lewisite (L), Blister agents (HN-1, HN-2, HN-3), Blood agents (HCN, CK), Nerve agents (G-series, V-series), Riot control agents (CN, CS, CR, DM, CN-PS), and common industrial toxics (Cl₂, H₂S, CO, CH₄, gasoline vapors) |
| Detection Range | 0.02–100 ppm (agent-specific) |
| Response Time | <10 ms |
| Accuracy | ≤±5% FS (toxic agents), ≤±0.5% (O₂) |
| Repeatability | ≤1% FS |
| Output Signal | 4–20 mA / 0–20 mA |
| Operating Voltage | 12–24 VDC (sensor module) |
| Environmental Operating Range | –20 °C to +40 °C, 0–95% RH, 86–106 kPa |
| Enclosure Rating | Ex ia IICT6 Gb (Intrinsically Safe for Zone 0/1 hazardous areas) |
| Weight | ≤5 kg |
| Continuous Operation | 24/7 |
| Sensor Lifetime | 12–24 months (12-month warranty against manufacturing defects) |
| Brand | BJBY |
|---|---|
| Origin | Beijing, China |
| Model | JC-RAD-14 |
| Sampling Method | Active Pump-aspiration |
| Measurement Range | Air Radon: 3–150,000 Bq/m³ |
| Soil Radon | 300–400,000 Bq/m³ |
| Radon Exhalation Rate | 0.001–10.000 Bq/(m²·s) |
| Water Radon | 0.003–100 Bq/L |
| Detection Repeatability | ≤5% (at 1800 Bq/m³, 65% RH, 25°C) |
| 8-h Drift | ≤10% |
| Power | Rechargeable Li-ion battery (≥30 h continuous operation) or AC adapter |
| Operating Temperature | −10°C to +40°C |
| Relative Humidity | ≤98% RH |
| Display | Backlit dot-matrix LCD |
| Data Storage | >200,000 records |
| Flow Rate | Up to 3 L/min (peak) |
| Communication Interfaces | USB, RS232, RS485, TCP/IP, Industrial Wireless |
| Inlet/Outlet Fittings | Anodized Aluminum |
| Self-background Count Rate | ≤0.3 cpm |
| Brand | BlueJing |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | LJ-JK90-CH2O |
| Detection Principle | Electrochemical Sensor (Formaldehyde-Specific) |
| Measurement Range | 0–100 ppm, 500 ppm, 2000 ppm, 5000 ppm, 10,000 ppm, 20,000 ppm, 50,000 ppm, or 0–20% Vol (configurable per application) |
| Repeatability | ≤±2% FS |
| Sampling Method | Built-in diaphragm pump (800 mL/min flow rate) |
| Response Time | T90 ≤ 20 s |
| Operating Temperature | −40 °C to +70 °C |
| Relative Humidity Range | 0–99% RH (non-condensing) |
| Display | 3.5″ TFT color LCD (320 × 240 px) |
| Data Storage | Standard 100,000 records |
| Battery | 3.6 V DC, 10,000 mAh rechargeable polymer lithium battery |
| Protection Rating | IP66 |
| Explosion Protection | Ex ia II CT6 (Intrinsic Safety) |
| Dimensions | 230 × 210 × 120 mm (L × H × W) |
| Weight | 2.5 kg |
| Brand | Bluejing |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | LJ-YDZ |
| Measurement Parameters | Hardness (0.2–40,000 mg/L as CaCO₃), Chloride Ion, pH/Temp, Dissolved Oxygen (DO), Oxidation-Reduction Potential (ORP) |
| Display | 10-inch Color TFT Touchscreen (Bilingual Chinese/English UI) |
| Output Options | 4–20 mA (opto-isolated), RS-485 / RS-232 (Modbus RTU), Relay Alarms (dual SPDT), Optional HART, NB-IoT/GPRS/LoRa |
| Power Supply | AC 220 V ±10% or DC 24 V |
| Power Consumption | ≥5 W |
| Enclosure Rating | IP65 (main cabinet), IP68 (submersible sensors) |
| Operating Temperature | 0–60 °C (non-freezing) |
| Storage Temperature | −10–60 °C |
| Installation Modes | Top-mount, Top-flange, Side-wall, In-line, Immersion, Flow-through |
| Sensor Protection | Integrated optical-electronic filtration, self-cleaning brush, ruggedized protective cap |
| DO Measurement Principle | Fluorescence-based (membrane-covered, electrolyte-free) |
| Temperature Compensation | Built-in NTC sensor per probe |
| Data Refresh Interval | Adjustable down to 1 s |
| Repeatability | ≤1% FS |
| Hardness Accuracy | ±1–2% of calibrated range |
| Dimensions (Cabinet) | 156 × 150 × 85 mm (W×H×D) |
| Panel Cutout | 156 × 94 mm |
| Standard Cable Length | 10 m (customizable) |
| Brand | Environ Lab |
|---|---|
| Origin | USA |
| Model | BODTECH-8 |
| Instrument Type | Laboratory BOD Analyzer |
| Measurement Principle | Mercury-Free Pressure-Based Dissolved Oxygen Consumption Detection (Piezoelectric Crystal Sensor) |
| Measurement Range | 0–4000 mg/L (extendable to 5000 mg/L) |
| Accuracy | ±1 mg/L (±3.55 hPa) |
| Operating Pressure Range | 500–1100 hPa |
| Temperature Compensation | Automatic, Real-Time |
| Stirring Speed | 180–450 rpm |
| IP Rating | IP54 |
| Ambient Operating Temperature | +5°C to +50°C |
| Power Supply | Button-Cell Lithium Battery |
| Max Concurrent Samples | 4 × n (modular 4-bottle units) |
| Display | 2-Digit 7-Segment LED |
| Sample Handling | Undiluted, Direct Measurement |
| Stirring Configuration | Electromagnetic, Continuous |
| Data Logging | Daily Automated BOD Value Capture and Storage |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | GXH-3011A |
| Instrument Type | Portable |
| Detection Target | Single-component (CO only) |
| Measurement Range | 0–50 ppm |
| Repeatability | ≤1% F.S. |
| Resolution | 0.1 ppm |
| Response Time (t₀–t₉₀) | ≤30 s |
| Zero Drift | ≤±2% F.S./4 h |
| Span Drift | ≤±2% F.S./4 h |
| Linearity Error | ≤±2% F.S. |
| Power Supply | AC 220 V (±10%) or rechargeable Li-ion battery |
| Dimensions | 245 × 190 × 85 mm |
| Weight | ≤3 kg |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Manufacturer | AMETEK Arizona |
| Type | Online Fixed-Station Monitor |
| Target Gas | Elemental Mercury Vapor (Hg⁰) |
| Response Time | ≤60 s |
| Measurement Accuracy | ±0.001 mg/m³ |
| Measurement Range | 0.003–0.999 mg/m³ |
| Sensor Technology | Gold Film Amalgamation |
| Environmental Rating | IP65 Enclosure |
| Operating Temperature | –20 °C to +50 °C |
| Data Output | Modbus RTU/TCP, Ethernet, Optional 4G LTE |
| Alarm Outputs | Relay + Email/SMS Notification |
| Compliance | OSHA PEL (0.1 mg/m³), NIOSH REL (0.05 mg/m³), ACGIH TLV (0.025 mg/m³), MSHA Standards |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | J405 |
| Instrument Type | Portable |
| Target Gas | Elemental Mercury Vapor (Hg⁰) |
| Response Time | 2 seconds |
| Measurement Accuracy | ±0.01 µg/m³ (±0.00001 mg/m³) |
| Measurement Range | 0.5–999 µg/m³ |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | J505 |
| Instrument Type | Portable |
| Target Gas | Elemental Mercury Vapor (Hg⁰) |
| Response Time | 8 s (Search Mode) |
| Measurement Accuracy | ±15% at 0.3 µg/m³ |
| Measurement Range | 0.05 µg/m³ to 500 µg/m³ |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | EM27/SUN |
| Spectral Range (NIR) | 5000–14500 cm⁻¹ |
| Spectral Range (MIR) | 750–5200 cm⁻¹ |
| Spectral Resolution (MIR, optional) | 0.2 cm⁻¹ (standard: 0.5 cm⁻¹) |
| Application | Ground-based solar absorption spectroscopy for atmospheric trace gas monitoring |
| Compliance | Designed for field-deployable, long-term unattended operation in remote environments |
| Software Interface | Integrated CAMTracker solar tracking control with real-time alignment feedback |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | HI 90 |
| Pricing | Available Upon Request |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | MATRIX II-MG |
| Detection Scope | Simultaneous Quantification of Major, Minor, and Trace Gaseous Impurities (ppb to % v/v) |
| Optical Path Length Options | 10 cm – 26 m (Heated Up to >180 °C for Condensable Gases) |
| Compliance | Designed for ISO 14644-8, ASTM D7538, IEC 62409, and GLP/GMP-Ready Data Integrity Architecture |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | MGA10-GP |
| Measurement Principle | Mid-Infrared Quantum Cascade Laser Absorption Spectroscopy (QCLAS) |
| Simultaneous Target Gases | CH₄, CO, CO₂, SO₂, NH₃, N₂O, NO, NO₂, H₂O, O₃, COS, HCHO, HONO |
| Measurement Frequency | 1 Hz or 10 Hz (user-selectable) |
| Detection Limit | Sub-ppb to low-ppb range for most analytes |
| Interference Resistance | High specificity due to narrow-linewidth QCL emission and spectral fingerprint matching |
| Operating Environments | Laboratory, mobile platforms (aircraft, vehicle, ship), and unattended ground stations |
| Compliance | Designed to support ISO 14064-1/2, EPA Method TO-15 & ASTM D6348, and GLP/GMP-aligned data integrity workflows |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | OMEGA 5 |
| Principle | Infrared Absorption Spectroscopy (FTIR) |
| Type | Online, Real-time |
| Response Time | <1 s |
| Detection Range | ppb to 100% |
| Sample Compatibility | >300 gas compounds |
| Gas Cell | 5 m multipass reflective cell with nickel-plated body and gold-coated mirrors |
| Interferometer | RockSolid™ permanent alignment |
| Detector | Thermoelectrically cooled MCT |
| Light Source | CenterGlow™ broadband IR source |
| Software | OPUS GA v8.x with spectral library and nonlinear fitting engine |
| Compliance | ASTM D6348, ISO 12039, USP <1227>, GLP/GMP-ready audit trail |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SIGIS II |
| Pricing | Upon Request |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | BSQ-20 |
| Power Supply | AC 220 V |
| Sample Vial Capacity | 12 mL |
| Vial Tray Configuration | 14 × 14 (196 positions) |
| Positioning Accuracy | ±0.01 mm |
| Controller Display | Blue TFT LCD |
| Dimensions (W × D × H) | 490 mm × 482 mm × 330 mm |
| Frame Material | Anodized Aluminum Alloy |
| Motion Control | Digital Stepper Motor with Microstepping Driver |
| Automation Level | Fully Unattended Operation |