Environmental Monitoring Instruments
Filter
Showing 841–870 of 9029 results
| Brand | Baseline |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | piD-TECH® eVx™ 045-011 |
| Price | Upon Request |
| Detection Range | 2,000 ppm |
| Minimum Detectable Quantity (MDQ) | 100 ppb |
| T90 Response Time | < 2 s (typical) |
| Certification | UL, CAN/CSA, ATEX, IECEx |
| Design | Intrinsically Safe, 4-Series Compatible Form Factor |
| Lamp Lifetime | Extended Operational Life |
| Temperature Sensitivity | Negligible |
| Humidity Compensation | Electrode-Based Suppression |
| Filtering | Dual-Stage Particle Protection |
| Signal Stability | Internal Linear Regulator Circuitry |
| Maintenance | Field-Serviceable, Cleanable Electrodes |
| Brand | Baseline |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | piD-TECH® eVx™ 045-013 |
| Price | Upon Request |
| Detection Range | 20 ppm |
| Minimum Detectable Quantity (MDQ) | 1.5 ppb |
| T90 Response Time | < 4 s (typical) |
| Housing Color | Yellow |
| Certification | UL, CAN/CSA, ATEX, IECEx |
| Sensor Architecture | 4-Series Compatible |
| Lamp Type | Long-Life UV Lamp (10.6 eV) |
| Internal Regulation | Dual Linear Voltage Regulators |
| Filtration | Dual-Stage Particle Filter |
| Humidity Compensation | Electrode-Based Suppression |
| Thermal Drift | Negligible |
| Maintenance | Field-Serviceable & Cleanable |
| Brand | Baseline |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | piD-TECH® eVx™ 045-014 |
| Pricing | Available Upon Request |
| Detection Range | 2 ppm |
| Minimum Detectable Quantity (MDQ) | 0.5 ppb |
| T90 Response Time | < 4 s (typical) |
| Certification | UL, CAN/CSA C/US, ATEX II 1G, IECEx Ex ia IIC T4 Ga |
| Sensor Architecture | 4-Series Compatible Form Factor |
| Lamp Life | > 12,000 hours |
| Operating Temperature Range | –20 °C to +50 °C |
| Humidity Compensation | Electrode-based suppression |
| Filtering | Dual-stage particulate protection |
| Power Supply | Internal linear regulation for signal stability |
| Maintenance | Field-serviceable, cleanable electrode assembly |
| Brand | Baseline |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | piD-TECH® eVx™ |
| Detection Range | 0–2,000 ppm |
| Minimum Detectable Quantity (MDQ) | 10 ppb |
| T90 Response Time | < 2 s (typical) |
| Certifications | UL, CAN/CSA C22.2 No. 152, ATEX II 2G Ex ia IIC T4 Ga, IECEx Ex ia IIC T4 Ga |
| Intrinsic Safety Design | Yes |
| Lamp Lifetime | > 12,000 hours |
| Operating Temperature | –20 °C to +50 °C |
| Humidity Compensation | Electrode-based humidity suppression |
| Dual-Stage Particle Filtration | Integrated |
| Signal Stability | Internal linear voltage regulation |
| Structural Compatibility | 4-Series electrochemical sensor footprint |
| Brand | BBE/bbe Moldaenke |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | A-ToxII |
| Instrument Type | Online |
| Test Organism | Algae (Chlorella vulgaris, ISO 8692:2012 compliant) |
| Operating Temperature | 0–35 °C |
| Reagent Storage Temperature | 0–30 °C |
| Brand | BBE Moldaenke |
|---|---|
| Origin | Germany |
| Manufacturer | BBE Moldaenke GmbH |
| Type | Imported Instrument |
| Model | Algae Torch Online |
| Application | Real-time in-situ chlorophyll a and phycocyanin quantification in natural and engineered water systems |
| Brand | BBE / bbe Moldaenke |
|---|---|
| Origin | Germany |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | Algae Torch |
| Measurement Parameters | Total Chlorophyll a (0–500 µg/L), Cyanobacterial Density, Turbidity (0–200 NTU), GPS Coordinates |
| Detection Time | <20 s |
| Resolution | 0.1 µg/L (Chl-a) |
| LOD | 0.15 µg/L |
| Excitation Wavelengths | 470 nm, 526 nm, 610 nm |
| Weight | 1.3 kg |
| Dimensions (H × Ø) | 500 mm × 60 mm × 68 mm |
| Power Supply | Internal Rechargeable Battery (AC Adapter: 110/240 V, 50/60 Hz) |
| Operating Temperature | 0–35 °C |
| Storage Temperature | 0–50 °C |
| IP Rating | IP68 |
| Depth Rating | 10 m (standard), 100 m (optional version) |
| Data Storage | 2000 measurements |
| Interface | USB |
| Software | bbe++ for Windows |
| Accessories | 10-m rope, telescopic pole, nylon backpack, underwater data cable extensions (10–30 m), sensor performance kits |
| Brand | BBE Moldaenke |
|---|---|
| Model | AlgaeTorch |
| Measurement Principle | In-situ algal pigment fluorescence detection (excitation at 470 nm, 525 nm, 610 nm) |
| Parameters | Total chlorophyll a / total algal density / cyanobacteria concentration |
| Range | 0–500 µg Chl-a/L |
| Response time | <20 s |
| Resolution | 0.1 ng Chl-a/L |
| Accuracy | ±0.015 ng Chl-a/L (total algae) |
| LOD | 0.1 µg Chl-a/L (single-species cyanobacteria) |
| Turbidity compensation | 0–200 FTU |
| Operating temperature | 0–35 °C |
| Depth rating | AlgaeTorch 10 (10 m), AlgaeTorch 100 (100 m) |
| Protection class | IP68 |
| Dimensions | 500 × 60 mm (H × Ø) |
| Weight | 1.3 kg |
| Power supply | 12 V DC (internal rechargeable battery) |
| Data interface | USB |
| Memory capacity | 2000 measurements |
| Software | bbe++ for Windows |
| Optional accessories | telescopic pole, shoulder strap, 10 m tether cable, probe performance kit |
| GPS module | integrated |
| Data output formats | ASCII, Excel (.xlsx), plain text |
| Brand | BBE / bbe Moldaenke |
|---|---|
| Origin | Germany |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | AOA |
| Application | Real-time online chlorophyll a and phytoplankton group quantification |
| Brand | BBE / bbe Moldaenke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | BG00750001 |
| Instrument Type | Online Volatile Phenol Analyzer |
| Output Interfaces | 4–20 mA, RS232/RS485, MODBUS RTU/TCP, Ethernet (optional) |
| Brand | BBE / bbe Moldaenke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Online Analyzer |
| Model | BG00750002 |
| Communication Options | 4–20 mA output, RS232/RS485 serial interface, MODBUS RTU/TCP, TCP/IP (optional) |
| Automation Features | Fully automated analysis cycle, programmable measurement interval, auto-cleaning, auto-calibration (manual calibration supported), power-loss recovery with automatic restart |
| Brand | BBE/bbe Moldaenke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | BG00750003 |
| Instrument Type | Benchtop |
| Analyte | Chloride Ion |
| Measurement Range | 0.1 mg/L |
| Limit of Detection (LOD) | 0.8 mg/L |
| Response Time | 10 min |
| Measurement Accuracy | ≤2% |
| Operating Temperature Range | 0–45 °C |
| Communication Interfaces | 4–20 mA, RS232/RS485, MODBUS RTU/TCP, TCP/IP (optional) |
| Brand | BBE / bbe Moldaenke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic (China-Made) |
| Model | bbe Cn-PWR II |
| Instrument Type | Online Analyzer |
| Communication Options | 4–20 mA analog output, RS232/RS485 serial interface, MODBUS RTU/TCP, TCP/IP (optional) |
| Brand | BBE / bbe Moldaenke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Online Analyzer |
| Measurement Principle | Potassium Dichromate Digestion Method (Online) |
| Wavelength | 600 nm (standard for Cr(VI)/Cr(III) absorbance ratio) |
| Measurement Range | 10–500 mg/L, 10–1000 mg/L, or 10–1500 mg/L (user-selectable range switching) |
| Accuracy | ≤ ±10% of reading |
| Repeatability | ≤ ±5% RSD |
| Limit of Detection (LOD) | 10 mg/L COD |
| Cycle Time | 30 minutes per analysis |
| Sample Volume per Cycle | 1.5–3 L |
| Compliance | Designed to meet ISO 6060 and EPA Method 410.4 requirements for online COD monitoring |
| Brand | BBE Moldaenke |
|---|---|
| Origin | Germany |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | Colifast ALARM |
| Pricing | Upon Request |
| Brand | BBE Moldaenke |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Colifast CALM |
| Pricing | Available Upon Request |
| Brand | BBE Moldaenke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Model | Colifast Field Kit |
| Pricing | Available Upon Request |
| Brand | BBE Moldaenke |
|---|---|
| Origin | Germany |
| Manufacturer | BBE Moldaenke GmbH |
| Country of Origin | Imported |
| Model | DFP |
| Portability | Portable |
| Target Organism | Cyanobacteria (Phytoplankton) |
| Operating Temperature Range | −2 °C to 40 °C |
| Reagent Storage Temperature | −2 °C to 40 °C |
| Measurement Cycle Time | 7 hours |
| Depth Range | 0–100 m |
| Brand | BBE Moldaenke |
|---|---|
| Origin | Germany |
| Manufacturer | BBE Moldaenke GmbH |
| Product Type | Online Water Toxicity Analyzer |
| Model | Fish Toximeter II |
| Operating Temperature Range | 5–28 °C |
| Test Organism | Zebrafish (Danio rerio) |
| Detection Principle | Real-time Video-Based Behavioral Analysis |
| Compliance Basis | Extended Dynamic Daphnia Test (EDDT)-aligned methodology, aligned with ISO 10706:2000 (Water quality — Guidance on toxicity testing using fish), EU WFD (Water Framework Directive) monitoring principles |
| Brand | BBE Moldaenke |
|---|---|
| Origin | Germany |
| Manufacturer | BBE Moldaenke GmbH |
| Type | Imported |
| Model | TS |
| Application | Field-deployable chlorophyll a and algal class quantification |
| Measurement Principle | Multi-wavelength excitation fluorescence spectroscopy |
| Detection Depth | Up to 1000 m (optional) |
| Key Parameters | Total chlorophyll a (0–500 µg/L, resolution 0.01 µg/L, LOD 0.05 µg/L), yellow substance (CDOM), green algae, cyanobacteria, diatoms/dinoflagellates, cryptophytes, depth (0–100/200/1000 m), temperature (−2 to 40 °C), transmittance (0–100%), pressure sensor integrated |
| Power | 12 V DC, internal rechargeable battery |
| Housing | Reinforced carbon fiber / V4A stainless steel (6.4 kg standard, 7.2 kg with housing, 5.1 kg titanium option) |
| Dimensions | 450 mm × 140 mm (H × Φ) |
| Memory | 2 GB (≥1000 datasets) |
| Interface | RS485 |
| Maintenance Interval | ≥7 days |
| Optional Accessories | Desktop mount, temperature probe, wiper unit, protective housing, cable reel, auto-start plug, Bluetooth handheld interface, transport case, cables (3/10/20/30/50/100 m) |
| Brand | BBE Moldaenke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | Ver. 1.1 |
| Instrument Type | Algal Quality Control System |
| Compliance | Designed for ISO/IEC 17025-aligned QC workflows in environmental laboratories |
| Brand | BBE Moldaenke |
|---|---|
| Origin | Germany |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | BG00430000 |
| Measurement Parameters | Total chlorophyll a / total algal density |
| Measurement Range | 0–500 µg chl-a/L |
| Resolution | 0.01 µg chl-a/L |
| Detection Limit | 0.05 µg chl-a/L |
| Light Transmission Range | 0–100% |
| Excitation Wavelengths | 370, 470, 525, 570, 590, 610 nm |
| Measurement Time | ≤3 min per sample |
| Sample Volume | 25 mL |
| Operating Temperature | 0–35 °C |
| Storage Temperature | 0–50 °C |
| Dimensions (H×W×D) | 185 × 330 × 350 mm |
| Weight | 7.5 kg |
| Power Supply | 110/240 V AC, 50/60 Hz or 12 V DC |
| Power Consumption | 10 W |
| Protection Rating | IP54 |
| Data Interface | RS232 |
| Software | bbe++ (Windows-based database software) |
| Optional Accessories | Photosynthetic activity module |
| Brand | BBE Moldaenke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Online Analyzer |
| Measurement Principle | Potassium Permanganate Oxidation with ORP Endpoint Detection |
| Range | 0–8 mg/L and 0–20 mg/L (dual-range auto-switching) |
| Repeatability | ±3% of Full Scale (FS) |
| Accuracy | ≤±3% FS |
| Limit of Detection (LOD) | 0.4 mg/L |
| Resolution | 0.01 mg/L |
| Analysis Cycle Time | 60 minutes per sample |
| Brand | BBE Moldaenke |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | TC |
| Instrument Type | Algal Cell Counter |
| Detection Principle | In Vivo Chlorophyll-a Fluorescence Analysis |
| Measurement Range | 0–20,000 cells/mL |
| Resolution | 1 cell/mL |
| Weight | 2.5 kg |
| Dimensions (H×W×D) | 258 × 243 × 117 mm |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Protection Rating | IP54 (lid closed), IP22 (lid open) |
| Interface | USB |
| Sample Temperature Range | 5–55 °C |
| Ambient Operating Temperature | 5–35 °C |
| Data Storage Capacity | >100,000 measurements |
| Storage Temperature | 5–45 °C |
| Accessories Included | User Manual, 50 µm Filter, Power Adapter, 50-Filter Kit |
| Optional Accessory | 50-Filter Kit |
| Brand | BBE / bbe Moldaenke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic (China-Made) |
| Model | bbe NH4—PWR II |
| Instrument Type | Online Water Quality Analyzer |
| Measured Parameter | Ammonia-Nitrogen (NH₃-N) |
| Measurement Principle | Salicylate Spectrophotometry |
| Detection Range | 0–0.5 / 2 / 4 / 20 / 100 mg/L NH₃-N (selectable) |
| Accuracy | ≤ ±3% FS or 0.0014 mg/L (whichever is greater) |
| Repeatability | ≤2% |
| Limit of Detection (LOD) | 0.0027 mg/L (at 0–0.5 mg/L range) |
| Zero Drift | ≤1% FS/24 h |
| Span Drift | ≤2% FS/24 h |
| Measurement Cycle Time | 500 s |
| Resolution | 0.0001 mg/L (at 0–0.5 mg/L range) |
| Dimensions (H×L×W) | 1100 × 600 × 310 mm |
| Weight | ~45 kg |
| Sample Requirements | Oil-free, low-suspended solids |
| Temp | 2–40 °C |
| Pressure | 0.0–0.1 bar |
| Flow Rate | 1.5–3.0 L/min |
| Output Interfaces | 4–20 mA analog, RS232/RS485 serial |
| Communication Protocols | MODBUS RTU/TCP (optional), TCP/IP (optional) |
| Calibration | Automatic & manual |
| Maintenance | Modular design with tool-free access |
| Display | Integrated touchscreen HMI |
| Data Integrity Features | Built-in QC check verification, remote status monitoring (optional) |
| Environmental Compliance | Designed for continuous operation in Class I, Division 2 hazardous locations per IEC 60079-0 (general requirements) |
| Brand | BBE / bbe Moldaenke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | bbe Phenol—PWR II |
| Instrument Type | Online Water Quality Analyzer |
| Analyte | Volatile Phenol |
| Measurement Range | 0–0.1 / 2 / 20 mg/L (selectable) |
| Detection Limit | 0.001 mg/L (at lowest range) |
| Accuracy | ≤ ±3% FS or 0.0008 mg/L (whichever is greater) |
| Repeatability | ≤3% |
| Zero Drift | ≤2% FS/24h |
| Span Drift | ≤2% FS/24h |
| Measurement Cycle Time | 39 minutes |
| Resolution | 0.0001 mg/L (at lowest range) |
| Dimensions (H×L×W) | 1100 × 600 × 310 mm |
| Weight | ~45 kg |
| Sample Requirements | Oil-free and particle-free |
| Temperature | 2–40 °C |
| Pressure | 0.0–0.1 bar |
| Flow Rate | 1.5–3.0 L/min |
| Output Interfaces | 4–20 mA, RS232/RS485 |
| Communication Protocols | MODBUS RTU/TCP (optional), TCP/IP (optional) |
| Calibration | Automatic & manual |
| Cleaning | Fully automated |
| Compliance Features | Built-in QC verification, remote operational status monitoring (optional) |
| Brand | BBE Moldaenke |
|---|---|
| Origin | Germany |
| Manufacturer | BBE Moldaenke GmbH |
| Type | Laboratory Instrument |
| Model | PhycoLA |
| Operating Temperature | 0–40 °C |
| Reagent Storage Temperature | 0–40 °C |
| Sample Volume per Batch | 25 mL |
| Biological Target | Cyanobacteria and Algal Taxa |
| Application Domain | Freshwater and Brackish Water Quality Monitoring |
| Brand | bbe Moldaenke |
|---|---|
| Origin | Germany |
| Manufacturer | bbe Moldaenke GmbH |
| Country of Origin | Imported |
| Model | PS |
| Instrument Type | Online |
| Biological Target | Algae |
| Operating Temperature | 0–40 °C |
| Reagent Storage Temperature | 0–40 °C |
| Sample Volume per Cycle | 45 mL |
| Brand | BBE / bbe Moldaenke |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | bbe TN—PWR II |
| Instrument Type | Online Water Quality Analyzer |
| Measured Parameter | Total Nitrogen (TN) |
| Measurement Principle | Alkaline Potassium Persulfate Digestion + UV-Vis Spectrophotometry |
| Measurement Range | 0–2.5 / 10 / 50 / 350 mg/L TN (selectable) |
| Accuracy | ≤ ±3% FS or ±0.05 mg/L (whichever is greater) |
| Repeatability | ≤2% RSD |
| Detection Limit | 0.05 mg/L (at lowest range) |
| Zero Drift | ≤3% FS/24 h |
| Span Drift | ≤3% FS/24 h |
| Measurement Cycle Time | 21 minutes |
| Resolution | 0.01 mg/L (at lowest range) |
| Dimensions (H×L×W) | 1190 × 600 × 310 mm |
| Weight | ~45 kg |
| Sample Requirements | Oil-free, low-suspended solids |
| Temp. | 2–40 °C |
| Pressure | 0–0.1 bar |
| Flow Rate | 1.5–3.0 L/min |
| Output Interfaces | 4–20 mA analog output, RS232/RS485 serial communication |
| Protocol Support | MODBUS RTU/TCP (optional), TCP/IP (optional) |
| Key Features | Full-spectrum UV-Vis detection (220 nm, 275 nm, 400 nm, 700 nm), turbidity interference correction, integrated UV-assisted digestion, automatic calibration & cleaning, touchscreen HMI, remote status monitoring & QC verification (optional), power-fail recovery |
| Brand | BBE / bbe Moldaenke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | bbe TP—PWR II |
| Instrument Type | Online Water Quality Analyzer |
| Analyte | Total Phosphorus |
| Measurement Principle | Acidic Peroxysulfate Digestion + Ammonium Molybdate Spectrophotometry (λ = 880 nm) |
| Detection Limit | 0.0035 mg/L (at 0–0.5 mg/L range) |
| Accuracy | ≤ ±3% FS or ±0.003 mg/L (whichever is greater) |
| Repeatability | ≤1% |
| Zero Drift | ≤1% FS/24h |
| Span Drift | ≤2% FS/24h |
| Measurement Cycle | 30 minutes |
| Resolution | 0.0001 mg/L (0–0.5 mg/L range) |
| Dimensions (H×L×W) | 1100 × 600 × 310 mm |
| Weight | ~45 kg |
| Sample Requirements | Oil-free, low-suspended solids |
| Temp. | 2–40 °C |
| Pressure | 0.0–0.1 bar |
| Flow Rate | 1.5–3.0 L/min |
| Output Interfaces | 4–20 mA analog, RS232/RS485 serial |
| Communication Protocols | MODBUS RTU/TCP (optional), TCP/IP (optional) |
| UV-Assisted Digestion | Integrated |
| QC Verification & Remote Monitoring | Optional |