| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3500 |
| Detection Principle | NDIR & Electrochemical (ECD) |
| Configuration | Fixed-mount online analyzer |
| Response Time | T90 < 15 s (NDIR channels) |
| Measured Gases | CO, CO₂, CH₄, C₃H₈, O₂, H₂S |
| Explosion Protection Rating | Ex d IIC T6 / Ex tb IIIC T80°C Db |
| Measurement Ranges | CO/CO₂/CH₄/C₃H₈: 0–100% vol |
| O₂ | 0–25% vol |
| H₂S | 0–9999 ppm |
| Accuracy | ±1% FS (NDIR gases), ±2% FS (O₂ & H₂S) |
| Repeatability | ≤2% |
| Resolution | 0.01% vol (low-range: 1 ppm for H₂S) |
| Sample Flow Rate | 0.7–1.2 L/min |
| Inlet Pressure | 2–50 kPa |
| Output Interfaces | RS-485, RS-232, 4–20 mA, Ethernet |
| Power Supply | AC 220 V, 50 Hz |
| Display | Backlit LCD |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3500 |
| Measurement Principle | NDIR & Electrochemical Detection |
| Configuration | Fixed Online Analyzer |
| Response Time | T90 < 15 s (NDIR) |
| Repeatability | ≤2% FS |
| Accuracy | ±1% FS (CO/CO₂/CH₄/C₃H₈), ±2% FS (O₂/H₂S) |
| Resolution | 0.01% vol (low-range: 1 ppm) |
| Measured Gases | CO, CO₂, CH₄, C₃H₈, O₂, H₂S |
| Flow Rate | 0.7–1.2 L/min |
| Sample Pressure | 2–50 kPa |
| Explosion Protection | Ex d II CT6 / Ex tb IIIC T80°C Db |
| Output Interfaces | RS-485, RS-232, 4–20 mA, Ethernet |
| Power Supply | AC 220 V, 50 Hz |
| Display | LCD |
| Preconditioning | Integrated sample conditioning system (particulate filtration, moisture removal, oil exclusion) |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3500 |
| Measurement Principle | Non-Dispersive Infrared (NDIR) & Electrochemical Detection (ECD) |
| Configuration | Fixed Online Analyzer |
| Response Time | T90 < 15 s (NDIR) |
| Repeatability | ≤2% FS |
| Measured Gases | CO, CO₂, CH₄, C₃H₈, O₂, H₂S |
| Explosion Protection Rating | Ex d IIC T6 / Ex tb IIIC T80°C Db |
| Output Interfaces | RS-485, RS-232, 4–20 mA, Ethernet |
| Power Supply | AC 220 V, 50 Hz |
| Sample Flow Rate | 0.7–1.2 L/min |
| Sample Pressure | 2–50 kPa |
| Display | LCD |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3500 |
| Measurement Principle | NDIR & Electrochemical Detection |
| Configuration | Fixed Online Analyzer |
| Response Time | T90 < 15 s (NDIR) |
| Repeatability | ≤2% FS |
| Accuracy | CO/CO₂/CH₄/C₃H₈: ±1% FS |
| O₂/H₂S | ±2% FS |
| Resolution | 0.01% (low-range: 1 ppm) |
| Measured Gases | CO, CO₂, CH₄, C₃H₈, O₂, H₂S |
| Measurement Ranges | CO/CO₂/CH₄/C₃H₈: (0–100)% |
| O₂ | (0–25)% |
| H₂S | (0–9999) ppm |
| Sample Flow Rate | (0.7–1.2) L/min |
| Inlet Pressure | (2–50) kPa |
| Sample Requirements | Dust-free, moisture-free, oil-free |
| Output Interfaces | RS-485, RS-232, 4–20 mA, Ethernet |
| Power Supply | AC 220 V, 50 Hz |
| Display | LCD |
| Explosion Protection Rating | Ex d II CT6 / Ex tb IIIC T80°C Db |
| Materials in Contact with Sample Gas | 316L stainless steel, PTFE |
| Built-in Zero Calibration | Air auto-zero pump |
| Diagnostics | Real-time sensor health monitoring |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-7500H-OPC |
| Measurement Principle | Ultrasonic Transit-Time Difference |
| Flow Range | 0–5 L/min |
| Accuracy | ±3% FS or ±0.06 L/min (at 5–45 °C) |
| Response Time | ≤0.3 s |
| Operating Temperature | −20 °C to +60 °C |
| Relative Humidity | 0–95% RH (non-condensing) |
| Supply Voltage | DC 4.75–12.6 V (ripple ≤50 mV) |
| Current Consumption | ≤35 mA |
| Interface | UART TTL (3.3 V logic level) |
| Dimensions | 80 × 22 × 25 mm (W × H × D) |
| EMC Compliance | Certified per IEC/EN 61000-6-2 & 61000-6-4 |
| Regulatory Approvals | CE, CMC |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | Gasboard-7500K |
| Price | USD 192 (approx. ¥1350) |
| Detection Principle | Ultrasonic Time-of-Flight (TOF) |
| O₂ Concentration Range | 0–100% vol (PSA-specific range: 20.5–95.6% vol) |
| O₂ Flow Range | 0–10 L/min |
| O₂ Concentration Accuracy | ±1.5% FS @ (10–45)°C |
| O₂ Flow Accuracy | ±0.2 L/min @ (10–45)°C |
| Resolution | 0.1% vol (O₂), 0.1 L/min (flow) |
| Response Time | ≤1.5 s (concentration), ≤0.3 s (flow) |
| Operating Temp. | 5–50°C, RH ≤95% non-condensing |
| Storage Temp. | −20–60°C, RH ≤95% non-condensing |
| Supply Voltage | DC 4.75–12.5 V, ripple <50 mV |
| Avg. Current Draw | <35 mA |
| Output Interface | UART TTL (5 V logic) |
| Dimensions | 120 × 22 × 13.6 mm (W × H × D) |
| Certifications | CMC, CE, EMC compliant |
| Calibration | Factory-calibrated, lifetime zero-drift compensation, no field recalibration required |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Gasboard-7500K-OAQ |
| Detection Principle | Ultrasonic Transit-Time Method |
| Flow Range | 0–20 L/min |
| Accuracy | ±3% FS or ±0.2 L/min (at 5–45 °C) |
| Response Time | ≤0.3 s |
| Operating Temperature | −20 °C to +60 °C |
| Operating Humidity | 0–95% RH (non-condensing) |
| Storage Conditions | −20 °C to +60 °C, 0–95% RH (non-condensing) |
| Supply Voltage | DC 4.75–12.6 V (ripple ≤50 mV) |
| Current Consumption | ≤35 mA |
| Interface | UART TTL (5 V logic) |
| Dimensions | 120 × 30 × 22 mm (W × H × D) |
| Certifications | CMC, CE, EMC compliant |
| Zero Drift | Negligible (factory-compensated) |
| Calibration | Factory-calibrated |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | Gasboard-8500D |
| Price | USD 149 (FOB) |
| Detection Principle | Ultrasonic Time-of-Flight (TOF) |
| Measurement Range | 20.5–95.6% O₂ (binary gas mixtures) |
| Accuracy | ±3% FS @ (5–45)°C |
| Resolution | 0.1% O₂ |
| Response Time (T₉₀) | ≤10 s |
| Flow Rate Range | 0–80 L/min |
| Operating Temperature | 5–50°C |
| Operating Humidity | 0–95% RH (non-condensing) |
| Storage Conditions | −20–60°C, 0–95% RH (non-condensing) |
| Supply Voltage | DC 4.75–12.6 V |
| Average Current Consumption | <50 mA |
| Output Interface | UART TTL (3.3 V logic level) |
| Dimensions | 60.7 × 26 × 30 mm (L×W×D) |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | Gasboard-8500V |
| Price | USD 149 (FOB) |
| Detection Principle | Ultrasonic Time-of-Flight (TOF) |
| Measurement Range | 20.5–100% O₂ (binary gas mixtures) |
| Accuracy | ±3% FS @ 5–45°C |
| Resolution | 0.1% O₂ |
| Response Time | <15 s (T90) |
| Operating Temp. | 5–50°C |
| Humidity Range | 0–95% RH (non-condensing) |
| Storage Temp. | −20–50°C |
| Supply Voltage | DC 4.75–12.5 V |
| Avg. Current Draw | <35 mA |
| Output Signal | 0–2500 mV analog |
| Dimensions | 46 × 29.3 × 29.3 mm (L×W×D) |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-8500Z |
| Detection Principle | Zirconia Electrochemical |
| Measurement Range | 0.1–25.0 vol.% O₂ |
| Accuracy | ±2% FS |
| Resolution | 0.01% O₂ |
| Response Time | <1 s |
| Operating Temperature | 10–50 °C |
| Operating Humidity | 5–85% RH (non-condensing) |
| Storage Conditions | −20–60 °C, 0–95% RH (non-condensing) |
| Supply Voltage | DC 12 V ±0.5 V |
| Output Interface | UART TTL (3.3 V logic level) |
| Dimensions | 70 × 40 × 15.3 mm (W×H×D) |
| Surface Temperature Limit | <150 °C (internal sensor element up to <350 °C) |
| Inlet Flow Mode | Free Diffusion |
| Cross-Sensitivity | Negligible (zirconia-selective for O₂) |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-9050GHG |
| Instrument Type | Online CEMS |
| Measured Gases | CH₄, CO₂, CO, N₂O, O₂ |
| Detection Principle | NDIR (CH₄/CO₂/CO/N₂O), Electrochemical (O₂) |
| Range | CH₄/CO/N₂O: 0–1000 ppm |
| CO₂/O₂ | 0–25% vol |
| Accuracy | CH₄/CO₂/CO/N₂O ≤ ±1% FS |
| Repeatability | ≤ ±1% FS |
| Resolution | CH₄/CO/N₂O: 1 ppm |
| CO₂/O₂ | 0.01% vol |
| Response Time (T₉₀) | < 25 s |
| Linearity Error | CH₄/CO₂/CO/N₂O ≤ ±1% FS |
| Flue Gas Temp. Limit | 0–300 °C |
| Sample Line & Probe Heating | 120–180 °C |
| Enclosure Rating | IP54 |
| Dimensions (L×W×H) | 800 × 760 × 1800 mm |
| Ambient Temp. | −20 to +50 °C |
| Ambient Humidity | < 95% RH (non-condensing) |
| Power Supply | 220 V AC ±10%, >3000 W |
| Compressed Air Requirement | 0.4–0.8 MPa, oil-free, dust-free, dry |
| Max. Air Consumption | 2.2 m³/h |
| Avg. | 0.45 m³/h |
| Max. Sample Flow | 2 L/min |
| Avg. | 1.5 L/min |
| Communication Interfaces | RS-485, RS-232, 4–20 mA, Ethernet |
| Built-in Zero Calibration | Air auto-zero via integrated zero-air pump |
| Self-Diagnostic Capability | Real-time sensor health monitoring |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GLDS-SF6 |
| Price | USD 420 (FOB) |
| Detection Principle | Non-Dispersive Infrared (NDIR) |
| Target Gas | Sulfur Hexafluoride (SF6) |
| Measurement Range | 0–1500 ppm |
| Alarm Threshold | Adjustable (Default: 1000 ppm) |
| Resolution | 1 ppm |
| Accuracy | ±2% FS @ 25°C |
| Repeatability | ≤±1% FS |
| Response Time (T90) | <30 s (Diffusion Mode) |
| Warm-up Time | <15 s |
| Operating Temperature | −20 to +60°C |
| Operating Humidity | 0–95% RH (non-condensing) |
| IP Rating | IP54 |
| Expected Service Life | ≥10 years |
| Dimensions | 63.2 × 38.5 × 19.23 mm |
| Compliance | DLT 1555–2016 |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | AM4209 |
| Weight | <400 g |
| Operating Temperature | 0°C to 40°C (32°F to 104°F) |
| IP Rating | IP54 |
| Detection Principle | Non-Dispersive Infrared (NDIR) |
| Sensitivity | 1 g/year (static), 3 g/year (dynamic) |
| Response Time | <1 s (typical) |
| Recovery Time | <5 s (typical) |
| Battery | 3.7 V DC, 2550 mAh Li-ion |
| Charging Time | 6 h |
| Standby Time | 10 h (backlight off) |
| Auto-Shutdown | 10 min |
| Compliance | EN 14624 |
| Gas Compatibility | R32, R290, R410A, R134a, R454A, R454B, R1234yf, HFO-1234yf and other A2L refrigerants |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | AM4210 |
| Pricing | Available Upon Request |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Instrument Type | Portable |
| Detection Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Measured Gas | CH₄ |
| Measurement Range | 0–1000 ppm |
| Detection Limit | 1 ppm |
| Alarm Accuracy | ±(5 ppm + 2% of reading) |
| Resolution | 1 ppm |
| Response Time (T90) | <10 s |
| Measurement Cycle | 30 s |
| Data Upload Interval | 2 min |
| Communication | LoRaWAN / NB-IoT |
| IP Rating | IP66 |
| Operating Temperature | −20 °C to +60 °C |
| Operating Humidity | 0–95% RH (non-condensing) |
| Operating Pressure | 86–106 kPa |
| Power Supply | Rechargeable Li-ion battery + optional solar panel |
| Max. Power Consumption | 2 W |
| Dimensions (L×W×H) | 186 mm × 144 mm × 417 mm |
| Weight | 6.5 kg |
| Service Life | ≥10 years |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Instrument Type | Portable |
| Detection Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Target Analyte | CH₄ |
| Measurement Range | 0–1000 ppm |
| Detection Limit | 1 ppm |
| Alarm Accuracy | ±(5 ppm + 2% of reading) |
| Resolution | 1 ppm |
| Response Time (T90) | <10 s |
| Measurement Cycle | 30 s |
| Data Upload Interval | 2 min |
| Communication | LoRaWAN / NB-IoT |
| IP Rating | IP66 |
| Operating Temperature | −20 °C to +60 °C |
| Operating Humidity | 0–95% RH (non-condensing) |
| Operating Pressure | 86–106 kPa |
| Power Supply | Rechargeable Li-ion battery + optional solar panel |
| Max. Power Consumption | 2 W |
| Dimensions (L×W×H) | 186 mm × 144 mm × 417 mm |
| Weight | 6.5 kg |
| Service Life | ≥10 years |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Basic Edition |
| Instrument Type | Portable |
| Measurement Principle | Optical Transmission (Nephelometric Absorption) |
| Maximum Permissible Error | ±2.0% |
| Measuring Range | Opacity N: 0–99.99% |
| Absorption Coefficient K | 0–16 m⁻¹ |
| Resolution | N: 0.1% |
| K | 0.01 m⁻¹ |
| Power Supply | Integrated Li-ion Battery (11.1 V / 35 Ah), ≥8 h continuous operation |
| Communication | Wi-Fi & Bluetooth |
| Data Output | Digital via USB/Bluetooth/Wi-Fi |
| Optional Accessories | HD Video Recording Module, Engine RPM & Oil Temperature Sensor Inputs |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Instrument Type | Portable |
| Model | CH4 |
| Resolution | 320 × 256 |
| Spectral Band | 3.2–3.5 µm |
| Temperature Range | −20 to 350 °C |
| Temperature Accuracy | ±1 °C (0–100 °C), ±2 °C (−20–0 °C), ±2% of reading (>100 °C) |
| Ingress Protection | IP54 |
| Explosion Protection | Ex ic nc op is IIC T4 Gc |
| Storage | 64 GB SD card |
| Connectivity | USB, HDMI, SD card slot, Wi-Fi |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | CJH-5 |
| Pricing | Available Upon Request |
| Measurement Principle | NDIR (Non-Dispersive Infrared) |
| Target Gas | Methane (CH₄) |
| Measurement Range | 0–100% LEL |
| Accuracy | ±5% F.S. |
| Resolution | 1% LEL |
| Response Time (T90) | <30 s |
| Warm-up Time | 30 s |
| Sampling Method | Diffusion |
| Explosion Protection Rating | Ex d II C T6 Gb |
| Output Signals | RS-485 (Modbus RTU), Dual SPST Relay Contacts (NO), 4–20 mA Analog Output |
| Operating Temperature | −20 to +60 °C |
| Storage Temperature | −40 to +85 °C |
| Humidity Range | ≤95% RH (non-condensing) |
| Display | Backlit LCD |
| Zero Calibration | Automatic drift compensation with temperature-compensated baseline correction |
| Power Supply | DC 12–24 V |
| Sensor Lifetime | >5 years (typical, non-consumable optical path) |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | CTD-01/CLD-01 |
| Detection Principle | Electrochemical (ECD) |
| Target Gases | CO, H₂S |
| Measurement Range | CO: 0–1000 ppm |
| H₂S | 0–100 ppm |
| Accuracy | ±2 µmol/mol or ±10% of reading |
| Resolution | 1 ppm |
| Response Time (T90) | <30 s |
| Warm-up Time | 30 s |
| Sampling Method | Diffusion |
| Explosion Protection Rating | Ex d II C T6 Gb |
| Certifications | CPA (China Metrology Accreditation), Ex Certificate |
| Output Signals | RS-485 digital interface, 2× SPST relay (NO), 1× 4–20 mA analog output |
| Operating Temperature | −20 to +60 °C |
| Storage Temperature | −40 to +85 °C |
| Relative Humidity | ≤95% RH (non-condensing) |
| Power Supply | DC 12–24 V |
| Display | LCD |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Measurement Principle | Optical Light Scattering |
| Safety Classification | Non-Explosion-Proof |
| Range | 0–20 mg/m³ |
| Accuracy | ≤ ±10% F.S. |
| LOD | 0.01 mg/m³ |
| Zero Drift | ±2% F.S./24h |
| Span Drift | ±2% F.S./24h |
| Operating Temp. | −20 to 50°C |
| Humidity | 5–95% RH (non-condensing) |
| Flue Gas Temp. Tolerance | <300°C |
| Data Update Rate | 1 Hz |
| Power Supply | DC 12 V ±0.5 V (ripple <100 mV) |
| Avg. Current Draw | <500 mA |
| Interface | UART_TTL (3.3 V logic) |
| Dimensions (W×H×D) | 272 × 111 × 193 mm |
| Anti-Clogging | Pneumatic Air Curtain Protection |
| Enclosure Rating | IP65-equivalent (based on module integration context) |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Instrument Type | Online Continuous Monitoring System |
| Measurement Principle | Condensation Particle Counter (CPC)-Based Nucleation and Growth |
| Max. Permissible Error | ≤ ±10% |
| Measured Parameter | Solid Particle Number Concentration in Engine Exhaust Gas |
| Minimum Detectable Size | 23 nm (50% counting efficiency) |
| Extended Detection Capability | Down to 10 nm (65% ±15% efficiency) |
| Dilution Stages | Two-Stage Precision Dilution (Primary: 10× |
| Secondary | 10–30× |
| Total Dilution Accuracy | ≤ ±10%) |
| VPR Efficiency | >99.0% for C40 hydrocarbons |
| Response Time (T90) | <5 s |
| Operating Environment | 5–35 °C, ≤80% RH |
| Compliance Standards | EU Regulation (EU) 2017/1151 (RDE), UNECE R83/R49/R101, ISO 8573-1, ASTM D7520, GB 18352.6–2016 (China VI), GB 17691–2018 (China VI Heavy-Duty), GB/T 38745–2020 |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Gasboard-2000 |
| Pricing | Available Upon Request |
| Measurement Principle | Dual-beam NDIR (Non-Dispersive Infrared) Spectroscopy |
| Measured Gases | CO, CO₂, HC (hydrocarbons), optional O₂ and NO |
| HC Range | (0–2000)×10⁻⁶ (ppm), CO: (0.00–10.00)×10⁻² (% vol), CO₂: (0.0–16.0)×10⁻² (% vol), NO (optional): (0–4000)×10⁻⁶ (ppm), O₂ (optional): (0.0–25.0)×10⁻² (% vol) |
| Accuracy | Complies with GB 18285–2018, ISO 3930, OIML R99 |
| Resolution | HC/NO: 1 ppm |
| CO/CO₂/O₂ | 0.001%/0.01%/0.01% vol |
| Response Time (T₉₀) | ≤4.5 s (NDIR) |
| Output Interface | RS-232 |
| Operating Voltage | 12 V ±0.2 V, 3.2 A |
| Environmental Compensation | Automatic temperature & pressure correction |
| Design | Modular sensor architecture, heated optical path |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-2006 |
| Measured Gases | CO, CO₂ |
| CO Range | 0–1000 ppm (Resolution: 0.1 ppm) |
| CO₂ Range | 0–20 vol.% (Resolution: 0.01 vol.%) |
| Detection Limit | CO: 0.5% F.S., CO₂: 0.1% F.S. |
| Linearity Error | ≤ ±1% F.S. |
| Response Time | ≤ 8 s @ 0.7 L/min |
| Repeatability | ≤ 1% F.S. |
| Stability | ≤ ±2% F.S./24 h |
| Operating Temperature | 5–40 °C |
| Relative Humidity | 0–95% RH (non-condensing) |
| Pressure Range | 86–115 kPa |
| Sample Flow Rate | 0.2–1.0 L/min |
| Output Interface | Modbus RTU (RS-485), RS-232 |
| Power Supply | 12 VDC ±0.2 V / 4 A |
| Max Power Consumption | 36 W (heating active), <800 mW (standby) |
| Heater Setpoint | 50 °C |
| Warm-up Time | <30 min |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-2060 |
| Detection Principle | Non-Dispersive Infrared (NDIR) |
| Target Gases | SiF₄, CF₄, SF₆, NF₃, CO₂ |
| Range | 1–264 ppm (0–200 mTorr) |
| Repeatability | ±0.5% |
| Linearity | ±1% F.S. |
| Detection Limit | 1 ppm |
| Output | Analog (4–20 mA) & Digital (RS485/Modbus RTU) |
| Design | Modular, Flange-Mountable (CF/KF compatible), Protocol-Ready for OEM Integration |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-2061 |
| Detection Principle | Non-Dispersive Infrared (NDIR) |
| Target Gases | WF₆, CF₄, SF₆, NF₃, CO₂ |
| Range | 1–264 ppm (0–200 mTorr) |
| Repeatability | ±0.5% |
| Linearity | ±1% F.S. |
| Detection Limit | 1 ppm |
| Output | Analog & Digital |
| Design | Modular, OEM-Ready |
| Compliance | Compatible with SEMI E19/E30/E37 standards |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-2100 |
| Detection Principle | Non-Dispersive Infrared (NDIR) with Microflow Dual-Chamber Architecture |
| Measurands | SO₂, NO, CO, CH₄ |
| Range (configurable) | 0–500 / 0–5000 ppm |
| Linearity Error | ±2% FS |
| Repeatability | ±2% FS |
| Zero/SPAN Drift | <2.5% FS/7 days |
| Temperature & Pressure Compensation | Integrated automatic compensation |
| Output Interface | Analog (4–20 mA / 0–5 V) and digital (RS485, Modbus RTU) |
| Operating Temperature | –10 °C to +50 °C |
| Enclosure Rating | IP65 |
| Compliance | RoHS, CE (EMC & LVD), ISO 9001-manufactured |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Gasboard-2102 |
| Price | Upon Request |
| Measurement Principle | Non-Dispersive Infrared (NDIR) with Microflow Dual-Chamber Detection |
| Target Gas | Nitric Oxide (NO) |
| Range | 0–200 / 0–2000 / 0–5000 ppm (customizable) |
| Resolution | 1 ppm |
| Accuracy | ±25 ppm or ±4% of reading (whichever is greater) |
| Repeatability | ±20 ppm or ±3% of reading (whichever is greater) |
| Response Time (T90) | ≤4.5 s |
| Temperature & Pressure Compensation | Automatic |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | Gasboard-2105 |
| Price | Upon Request |
| Measurement Principle | Microflow Non-Dispersive Infrared (NDIR) with Dual-Chamber (Sample + Reference) Architecture |
| Target Gases | CO, NO, SO₂, CO₂, CH₄ |
| Moisture Compensation | Integrated Humidity Compensation Module |
| Temperature & Pressure Compensation | Automatic Real-Time Compensation |
| Heating Control | Thermostatically Controlled Gas Cell |
| Linearity Error | ±2% FS |
| Repeatability | ±2% FS |
| Zero/Full-Scale Drift | <2.5% FS per 7 days |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-2108 |
| Measurement Principle | Dual-beam NDIR (CO, CO₂, HC) + Micro-flow NDIR (NO) |
| Gas Range | HC (0–2000 ppm), CO (0.00–5.00 %), CO₂ (0.0–16.00 %), NO (0–4000 ppm) |
| Accuracy | HC/NO ±4 ppm or ±3% / ±25 ppm or ±4% |
| Resolution | HC/NO 1 ppm |
| Repeatability | ±1% FS |
| Stability | <±2% FS/24h |
| Response Time (T90) | HC/CO/CO₂ ≤3.5 s |
| Output Interface | Modbus RTU (customizable protocol) |
| Operating Temp. | Auto-heated, temperature & pressure compensated |
| Compliance | GB 18285–2018 |