Environmental Monitoring Instruments
Filter
Showing 1291–1320 of 2621 results
| Brand | EXPEC / SUPEC |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SUPEC 8020 |
| Pricing | Available Upon Request |
| Brand | EXPEC (Pubichem) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | TRACE 8000 |
| Instrument Type | Online VOC Analyzer |
| Ion Source | Dual-Anode Hollow Cathode Lamp with H₂O Reagent Ion Chemistry |
| Mass Analyzer | Vertical-Entry Reflectron Time-of-Flight (TOF) |
| Detection Mode | Soft Chemical Ionization (PCI) via H₃O⁺ Transfer |
| Typical LOD | <100 pptv (sub-ppb) for C₂–C₁₀ VOCs |
| Operating Mode | Unattended Continuous Monitoring |
| Compliance Framework | Designed for ISO 16000-22, ASTM D6196-20, and EPA Method TO-15/TO-17 compatible workflows |
| Brand | EXPEC |
|---|---|
| Origin | Zhejiang, China |
| Model | WOT-3100 |
| Application | Organic Contaminant Source Identification via Fluorescence Excitation-Emission Matrix (EEM) Fingerprinting |
| Detection Principle | UV-Vis Fluorescence Spectroscopy (200–450 nm excitation |
| Operational Mode | Reagent-Free, Non-Destructive Optical Analysis |
| Deployment Flexibility | Benchtop, Mobile (Vehicle/Boat-Mounted), Field-Deployable |
| Data Integration Capability | Compatible with Heavy Metal Analyzers and Organic Pollutant Sensors for Multi-Parameter Emergency Response |
| Brand | Fangyuan Scientific Instruments |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | FY2700-00 |
| Detection Limits | α: 3–10 MeV |
| β | 0–5 MeV |
| Stability | Count rate drift < 0.2% over 24 h |
| Resolution | 0.01 (channel width in keV per channel, typical for digital pulse-height analysis) |
| Brand | Fangyuan Scientific Instruments |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | FY3104-00 |
| Instrument Type | Laboratory Alpha Spectrometer |
| Measurement Medium | Solid Samples |
| Detector Interface | Compatible with Commercial PIPS Detectors (International & Domestic) |
| Radiation Type | Alpha Particles |
| Sensitivity | 0.01 cpm (counts per minute) in 3–10 MeV range |
| Energy Range | 3–10 MeV |
| Background Count Rate | <1 count/hour (3–10 MeV) |
| Energy Resolution | FWHM ≤18 keV at 5.486 MeV (with 300 mm² PIPS detector, source-to-detector distance = detector diameter) |
| Multichannel Scaling | 512 / 1024 / 2048 / 4096 channels (software-selectable) |
| Bias Voltage | 0–180 V (digital, 0.2 V resolution) |
| Leakage Current Monitoring | –3 to +150 nA (accuracy <1 nA) |
| Vacuum Control | Adjustable vacuum hold, pump-down, and vent modes |
| Sample Chamber | Recoil suppression design |
| Sample Stage | Manually adjustable vertical positioning (4 mm resolution) |
| Detector Active Area | 300–1200 mm² |
| Operating Temperature | 0–40 °C |
| Relative Humidity | 10–80 % RH |
| Communication Interfaces | USB, RS-232, Ethernet, Wi-Fi |
| Software | AlphaSense — spectral acquisition, energy/efficiency calibration, nuclide library (built-in + user-defined), peak deconvolution, and GLP-compliant data logging |
| Brand | 4DigitalBooks |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | FastOcean APD |
| Instrument Type | In Situ Algal Fluorometer |
| Measurement Principle | Fast Repetition Rate (FRR) Fluorescence |
| Excitation Wavelengths | 450 nm, 530 nm, 624 nm |
| Depth Rating | 600 m |
| Operating Voltage | 18–36 V DC |
| Power Consumption | 4.8 W (peak 5 W) |
| Battery Life | 6 hours continuous operation |
| Sampling Frequency | 10 Hz |
| Fluorescence Signal Range | Equivalent to Chl-a concentration 0.02–200 mg/m³ |
| LED Irradiance Units | photons·m⁻²·s⁻¹ × 10²² |
| Software Platform | FastPro8 v3.2+ |
| Compliance | CE, RoHS, IP68 submersible housing |
| Data Output | ASCII, CSV, NetCDF |
| Interface | RS-232/RS-485, optional Ethernet/WiFi module |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | FD125 |
| Price Range | USD 7,000–14,000 (FOB) |
| Sampling Method | Passive Collection |
| Measurement Range | 0–10 Bq/m³ |
| Minimum Detectable Concentration | 0.01 Bq/m³ |
| Response Time | 300 s |
| Detector Background | ≤100 counts/s |
| Sensitivity Accuracy | ±10% |
| Operating Temperature | 0–45 °C |
| Relative Humidity Limit | ≤95% RH |
| Power Supply | +9–10 V DC for amplifier |
| Weight | 16 kg (excluding scaler unit) |
| Brand | Fengtu |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | FT-GD1 |
| Price | USD 10,800 (FOB) |
| Brand | Fengtu |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | FT-QC2 |
| Price | USD 570 (FOB) |
| Brand | Fengtu |
|---|---|
| Origin | Shandong, China |
| Model | TQ-TS200 |
| Soil Moisture Range | 0–100% VWC (±3% accuracy, 0.01% resolution) |
| Soil Temperature Range | −30 to +70°C (±0.3°C, 0.01°C resolution) |
| Soil EC Range | 0–20,000 µS/cm (±3% up to 10,000 |
| Brand | FENK |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Producer |
| Instrument Type | Benchtop Laboratory Analyzer |
| Model | CL-101 |
| Measurement Principle | Spectrophotometry (Absorption-based) |
| Wavelengths | 420 nm, 540 nm, 620 nm, 700 nm |
| Accuracy | ≤ ±5% (COD: ≤ ±8%) |
| Repeatability | ≤ 3% |
| Optical Stability | < ±0.001 ABS |
| Data Storage | 1,000 records |
| Display | 4.3-inch capacitive touchscreen LCD |
| Dimensions | 210 × 150 × 110 mm |
| Weight | 1.35 kg |
| Power Supply | DC 5 V / 2 A |
| Battery Capacity | 4800 mAh |
| Operating Environment | −10 to 40 °C, <80% RH (non-condensing) |
| Calibration Modes | Real-time calibration & formula-based calibration |
| Photometric Modes | Absorbance, Concentration, Transmittance |
| Cuvette Format | 16 mm round glass tubes |
| Compliance | Designed for ASTM D1252 (COD), ISO 7150-1 (NH₃-N), and EPA Method 350.1 (Ammonia) |
| Origin | Germany |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | FHT 762 |
| Price Range | USD 13,500–27,000 (FOB) |
| Instrument Class | Dose Rate Meter |
| Form Factor | Portable |
| Measured Radiation | Neutrons |
| Detector Type | Wide-Energy Neutron Detector |
| Dose Equivalent Range | 1 mSv/h – 10 Sv/h |
| Sensitivity | 0.84 cps per µSv/h (calibrated to ²⁵²Cf) |
| Gamma Rejection Ratio | < 5 µSv/h equivalent dose error at 100 mSv/h ¹³⁷Cs |
| Angular Dependence | ±20% over 4π geometry |
| Energy Response Range | 0.025 eV – 5 GeV (ICRP Publication 74, 1996) |
| Brand | EXPEC (Hangzhou Puyu Technology Co., Ltd.) |
|---|---|
| Model | FIA-3000 |
| Measurement Principle | DPD Colorimetric Method (ASTM D1253, ISO 7393-2, EPA 330.5) |
| Wavelength | 510 nm |
| Detection Range | Free Chlorine: 0.01–5.00 mg/L Cl₂ |
| Total Chlorine | 0.02–5.00 mg/L Cl₂ |
| Detection Limit | ≤0.01 mg/L (Free Cl₂), ≤0.02 mg/L (Total Cl₂) |
| Sample pH Adjustment | Automatic buffering to pH 6.2–6.5 |
| Catalyst | Iodide-mediated oxidation for total chlorine conversion |
| Optical System | LED-based photometer with dual-beam compensation |
| Enclosure Rating | IP65 |
| Installation Options | Wall-mounted or benchtop configuration |
| Reagent Consumption | <1.2 mL per analysis cycle |
| Waste Separation | Integrated reagent/waste fluid segregation |
| Compliance | Designed for GLP/GMP-aligned operation |
| Origin | Zhejiang, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Regional Origin | Domestic (China) |
| Model | Custom OEM Part Number Required |
| Pricing | Available Upon Request |
| Origin | Zhejiang, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | AMMS-100 |
| Pricing | Available Upon Request |
| Origin | Zhejiang, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | CEMS-2000 B S & LGA-4500 |
| Pricing | Available Upon Request |
| Origin | Zhejiang, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | Environmental Intelligence Solution |
| Pricing | Available Upon Request |
| (注意 | ��此处为严格按任务要求生成的英文产品名称。但需特别说明:原文品牌“聚光科技”英文官方名为 **Hangzhou FPI Science & Technology Co., Ltd.**, 常缩写为 **FPI**, 而非 Fortinet(Fortinet 是知名网络安全公司,与本仪器无关 |
|---|---|
| 此系用户输入误植。根据B2B SEO真实性原则 | ��必须修正为真实品牌。故正确名称如下:) |
| [Brand | FPI |
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) & System Integrator |
| Product Category | Atmospheric Heavy Metal Online Analyzer |
| Model | AMMS-100 |
| Measurement Principle | Beta-ray Absorption + Energy-Dispersive X-ray Fluorescence (ED-XRF) |
| Sample Collection | Continuous Filter-based Particulate Enrichment |
| Output Parameters | PM mass concentration (μg/m³), Elemental mass concentration (ng/m³), Element-to-PM ratio (ppm), Elemental mass fraction (%) |
| Simultaneous Elements | Up to 28 elements (Pb, Hg, Cr, Cd, As, etc.) |
| Detection Limit | As low as 0.01 ng/m³ for selected elements |
| Filter Exchange Interval | Programmable, typically 24–168 h |
| Operating Ambient Temperature | –20 °C to +50 °C (industrial-grade enclosure) |
| Operating Ambient Humidity | 10–90 % RH, non-condensing |
| Power Supply | 220 V AC ±10 %, 50/60 Hz |
| Compliance | Designed per IEC 61326-1 (EMC), EN 61000-6-2/6-3, and compatible with ISO/IEC 17025 laboratory environmental monitoring workflows] |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM/ODM Producer |
| Country of Origin | China |
| Model | AMSW-1100 |
| Pricing | Available Upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Product Category | Domestic (China-made) |
| Model | AQMS-100 |
| Pricing | Upon Request |
| Zero Air Purity | Not Specified |
| Flow Rate | Up to 20 L/min |
| Output Pressure | Adjustable |
| Dew Point | Not Specified |
| Flow Measurement Accuracy | Not Specified |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | AQMS-1000M |
| Pricing | Upon Request |
| Pollutant Parameters | O₃ (UV Photometry), SO₂ (UV Fluorescence), NOₓ (Chemiluminescence), CO (NDIR Gas Correlation Filtering), PM₁₀ & PM₂.₅ (Beta Attenuation Method) |
| Meteorological Parameters | Wind Speed, Wind Direction, Temperature, Relative Humidity, Atmospheric Pressure |
| Enclosure Rating | IP55 |
| Operating Temperature Range | -30 °C to +50 °C |
| Communication Interfaces | RS232, Ethernet, USB |
| User Interface | Integrated Industrial Touchscreen PC (Color, High-Resolution) |
| Configuration | Modular Analytical Subsystem Architecture |
| Compliance | HJ 653–2013, HJ 654–2013, HJ 655–2013 (China), US EPA EQOA Designated Methods |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | AQMS-200 |
| Pricing | Available Upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | AQMS-300 |
| Instrument Type | Online Fixed-Mount Analyzer |
| Detection Principle | UV Photometry (254 nm) |
| Compliance | Designed for EPA EQOA-01, ISO 13964, and EN 14625 compliance frameworks |
| Output Interfaces | RS232, RS485, Ethernet, 4–20 mA analog output |
| Calibration | Remote automatic zero/span calibration with programmable schedule |
| Lamp Monitoring | Integrated mercury lamp intensity self-diagnostic with lifetime estimation |
| Flow Protection | Auto-shutdown at sub-threshold sample flow rate |
| Security | Role-based remote access control with firmware upgrade authorization |
| Enclosure Rating | IP54 (indoor industrial use) |
| Brand | FPI (Focus Photonics Inc.) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer | Yes |
| Country of Origin | China |
| Model | AQMS-3000 |
| Pricing | Available upon request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Online Fixed-Station Analyzer |
| Detection Target | Single-Gas (CO) |
| Measurement Principle | Gas Filter Correlation Non-Dispersive Infrared (GFC-NDIR) |
| Compliance Context | Designed for ambient air quality monitoring networks compliant with Chinese HJ 659–2013 and compatible with international reference methods per ISO 12039 and EPA Method 10 |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | AQMS-500 |
| Configuration | Continuous Emission Monitoring System (CEMS)-Grade Online Analyzer |
| Regulatory Classification | Ambient Air Quality Monitoring Instrument |
| Compliance Framework | Designed for integration into national and municipal air quality monitoring networks compliant with HJ 654–2013, EPA Method 40 CFR Part 53, and ISO 7935:1995 (Air Quality — Determination of Sulfur Dioxide — Ultraviolet Fluorescence Method) |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | AQMS-600 |
| Pricing | Available Upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Atmospheric Heavy Metal & VOCs Online Analyzer |
| Model | Atmospheric BTEX Online Analyzer |
| Measurement Principle | Ambient-Temperature Preconcentration + High-Temperature Thermal Desorption + Capillary Gas Chromatography + Photoionization Detection (GC-PID) |
| Sample Introduction | Mass Flow Controlled (MFC) Quantitative Sampling |
| Thermal Desorption | Direct-Heating Rapid Desorption (>40°C/s) |
| Chromatographic Separation | Capillary Column with Valve-Switched Backflush |
| Detector | High-Sensitivity PID (10.6 eV Lamp) |
| Carrier Gas Control | Electronic Pressure & Flow Control (EPC/EFC) for Carrier, Make-up, and Auxiliary Gases |
| Compliance Framework | Designed for ISO 16000-6, ASTM D5197, US EPA Method TO-15 & IP-12, and GLP/GMP-aligned data integrity requirements |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Atmospheric Quality Monitoring Solution |
| Pricing | Available Upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | BBJ |
| Pricing | Available Upon Request |
| Enclosure Material | Die-Cast Aluminum Alloy |
| Lens Material | Tempered Glass (Red/Yellow/Blue Options) |
| IP Rating | IP65 |
| Hazardous Area Certification | ATEX/IECEx Zone 1 & 2, Class I Div 1 & 2, Class II Div 1 & 2, Class III Div 1 & 2 |
| Temperature Class | T1–T6 |
| Gas Group | IIA, IIB, IIC |
| Dust Hazard Compliance | EN 60079-31 (IEC 60079-31), ATEX 2014/34/EU Annex VIII Category 2D/3D |