Environmental Monitoring Instruments
Filter
Showing 1201–1230 of 9029 results
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | 2020 ClearTrace |
| Price | Upon Request |
| Measurement Range | 0–100 NTU |
| Resolution | 0.001 NTU |
| Accuracy | ±2% of reading or ±0.015 NTU (whichever is greater) |
| Response Time (90%) | 120 s |
| Sample Cell Volume | 135 mL |
| Light Source | Tungsten lamp (2-year service life) |
| Operating Temperature (Water) | –5 to 50 °C |
| Ambient Temperature | –20 to 60 °C |
| Flow Rate | 250–500 mL/min |
| Output | 4–20 mA |
| Compliance | EPA Method 180.1, CE (EN 61326, EN 61010-1), UL 508, Class I, Division 2, Group C/D |
| Brand | Cloudscape |
|---|---|
| Model | TH-CQX7 |
| Origin | Shandong, China |
| Manufacturer Type | OEM/ODM Producer |
| Instrument Type | All-in-One Ultrasonic Weather Station |
| Measurement Range | Wind Speed: 0–60 m/s |
| Accuracy | Wind Speed ±0.1 m/s + 0.01V, Wind Direction ±2°, Temp ±0.3°C (at 25°C), RH ±3% RH (20–80% RH), Pressure ±0.25%, Illuminance <±3%, Optical Rain Rate ≤±4% |
| Resolution | Wind Speed 0.01 m/s, Wind Direction 1°, Temp 0.01°C, RH 0.01% RH, Pressure 0.1 hPa, Illuminance 1 lux, Rain Rate 0.01 mm/min |
| Communication | Standard GPRS |
| Power Supply | 8–16 V DC input |
| Enclosure Material | Imported ASA polymer |
| IP Rating | IP65+ |
| Mounting | 2 m carbon steel mast, direct-sleeve sensor integration (no flange required) |
| Data Output | RS485 Modbus RTU & JSON over serial |
| Compliance | ISO 9001, ISO 14001, ISO 45001 certified manufacturer |
| Software | PC desktop client (serial/Modbus/JSON), Android app (Bluetooth/background operation), cloud platform (CS architecture, HJ-212, HTTP/TCP forwarding, map view, alarm thresholds, scriptable data post-processing) |
| Brand | Cloudscape |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | TH-FB01 |
| Instrument Type | Integrated Intrinsically Safe Weather Station |
| Wind Speed Range | 0–60 m/s |
| Wind Speed Accuracy | ±0.1 m/s + 0.01V |
| Wind Direction Range | 0–360° |
| Wind Direction Accuracy | ±2° |
| Air Temperature Range | −40 to +80 °C |
| Temp Accuracy | ±0.3 °C @ 25 °C |
| Humidity Range | 0–100 %RH |
| RH Accuracy | ±3 %RH (20–80 %RH) |
| Atmospheric Pressure Range | 300–1100 hPa |
| Pressure Accuracy | ±0.25 %FS |
| Data Storage Capacity | ≥500,000 records |
| Power Consumption | 1.75 W |
| Enclosure Rating | IP66/IP67 equivalent (per GB3836 compliance) |
| Certification | Ex ia IIC T6 Ga (GB3836.1-2010 & GB3836.4-2010) |
| Communication | RS-485 Modbus RTU |
| Software Compliance | Supports audit trail, configurable data logging intervals, and user-defined parameter mapping |
| Brand | CloudTop (Yuntang) |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Origin Category | Domestic (China) |
| Model | YT-WLY |
| Price | USD 17,000 (approx.) |
| Detection Limit | ≤0.01 ng/mL |
| Uranium Quantification Range | 0–20 ng/mL (extendable to 100 ng/mL via dilution) |
| Linearity (R²) | ≥0.999 |
| Precision (RSD) | ≤5% |
| Stability (8-h drift at 2 ng/mL) | ≤7% |
| Sample Throughput | Up to 80,000 analyses per UV source |
| Data Storage | 4,000 data points |
| Interface | USB 2.0, 100Base-T4 Ethernet |
| Display | 7-inch color TFT touchscreen |
| Dimensions | 450 × 350 × 185 mm |
| Net Weight | 10 kg |
| Power Supply | 220 V ±10%, 50 Hz |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CLYC |
| Price Range | USD 14,000 – 42,000 |
| Detection Limit | Bq/L |
| Stability | ±5% (over 24 h, 23°C) |
| Energy Resolution | <5.0% FWHM at 662 keV (¹³⁷Cs) |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | CM-02 |
| Price | Upon Request |
| Detection Range | 10–200 mg/L (low range), 50–2500 mg/L (high range) |
| LOD | 3 mg/L |
| Wavelength | 610 nm |
| Accuracy | ±5% (low range), ±4% (high range) |
| Chloride Interference Tolerance | 1000 mg/L (low), 2500 mg/L (high) |
| Measurement Time | 10–15 min |
| Heating Capacity | 25 tubes, 0–180 °C, timer 10–199 min |
| Optical Stability | ±0.003/5 min (blank) |
| Display Resolution | 0.001 |
| Operating Temperature | 5–35 °C |
| Storage Temperature | −10–45 °C |
| Power Consumption | ≤30 W (heater), ≤10 W (analyzer) |
| Weight | 3.0 kg (analyzer), 3.5 kg (full system) |
| Dimensions | 330 × 320 × 170 mm |
| Compliance | HJ/T 399–2007, EPA Method 410.4 (adapted), Standard Methods 5220D (COD by Closed Reflux Colorimetric) |
| Brand | CMI (California Measurements, Inc.) |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AFS |
| Pricing | Available Upon Request |
| UV Excitation Source | 280 ±20/−40 nm |
| Fluorescence Channel 1 (UV) | 330–650 nm |
| Fluorescence Channel 2 (Visible) | 420–650 nm |
| Sample Volume per Measurement | 2.5 cm³ |
| Dimensions (L×W×H) | 30 × 28 × 24 cm |
| Weight | 5.3 kg (11.3 lbs) |
| Power Supply | 90–260 VAC, 47–63 Hz |
| Operating Temperature | +5 to +30 °C |
| Relative Humidity Range | 0–95 % RH |
| Brand | CMI (California Measurements, Inc.) |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | ASPECT |
| Pricing | Available Upon Request |
| Communication Interface | USB |
| Particle Throughput | 20,000 particles/sec |
| Asymmetry Factor (Af) | 0–100 |
| Asymmetry Channel Count | 20 (Resolution: 5) |
| Flow Rate | 1.0 LPM (±10%) |
| Particle Size Range | 0.5–20 µm |
| Size Resolution | 0.5 µm |
| Particle Counting Capacity | <20,000/sec |
| Dimensions | 47 cm (L) × 27 cm (W) × 26 cm (H) |
| Weight | 20 kg |
| Brand | California Measurements, Inc. (CMI) |
|---|---|
| Origin | USA |
| Model | PC-2HX |
| Flow Rate | 2 SLPM |
| Total Mass Concentration Range | 5–1000 µg/m³ |
| Aerodynamic Cut-Point Diameters (50% efficiency) | Stage 1 >20 µm, Stage 2: 10 µm, Stage 3: 7 µm (PM₁₀ inlet), Stage 4: 4 µm, Stage 5: 2.5 µm (PM₂.₅), Stage 6: 0.7 µm (PM₁.₀), Stage 7: 0.4 µm, Stage 8: 0.25 µm, Stage 9: 0.15 µm, Stage 10: 0.10 µm |
| QCM Sensitivity | ~1 ng/Hz (average) |
| Frequency Drift (post-warm-up) | ≤2 Hz/min |
| Warm-up Time | ≤10 min |
| Operating Temperature | −20 to +40 °C |
| Power Supply | 120 V AC, 50/60 Hz, 50 W |
| Impactor Pressure Drop | 320 mmHg ±10% |
| Dimensions (Impactor) | 14" H × 5" W × 12" L / 12 lbs |
| Dimensions (Control Unit) | 7" H × 17" W × 12" L / 23 lbs |
| Brand | FPI (Focus Photonics Inc.) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | CMS odor 1000 |
| Detection Principle | Gas Chromatography–Ion Mobility Spectrometry (GC-IMS) |
| Instrument Type | Online Analytical System |
| Typical Configuration | Multi-Compound VOC & Odorant Analyzer |
| Regulatory Compliance | GB 14554–201X, DB31/1025–2016, DB12/059–2018 (22 regulated odorants, qualitative & quantitative) |
| Detection Limit | Sub-ppt (parts-per-quadrillion) for key sulfur/nitrogen compounds |
| Resolution | 100 (IMS drift time resolution, FWHM) |
| Accuracy | ≤10% RSD (relative standard deviation) for calibrated odorants |
| Response Time | ≤10 s (IMS-only mode) |
| Origin | Canada |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CMT 403 |
| Pricing | Available Upon Request |
| Brand | CNC (China Nuclear Control System) |
|---|---|
| Origin | Beijing, China |
| Model | BH1216III |
| Instrument Type | Laboratory-grade dual-channel liquid alpha/beta spectrometer |
| Detector Type | Plastic scintillator (ST-1221 main |
| Measurement Medium | Aqueous samples |
| Detection Efficiency | α ≥88% (²³⁹Pu, 2π geometry, Φ30 mm), β ≥55% (⁹⁰Sr–⁹⁰Y, 2π, Φ20 mm) |
| Background Count Rate | α ≤0.005 cm⁻²·min⁻¹, β ≤0.15 cm⁻²·min⁻¹ |
| Minimum Detectable Activity | α = 5×10⁻³ Bq, β = 1×10⁻² Bq |
| Anti-coincidence Efficiency | >99% |
| Shielding | 100 mm lead + 10 mm steel (total mass ≈500 kg) |
| Operating Temperature | 5–35 °C ±2 °C |
| Humidity | ≤85% RH at 30 °C |
| Dimensions | 605 × 541 × 1244 mm |
| Weight | ~500 kg |
| Compliance | Meets GB/T 11682–2021 (Chinese National Standard for Low-Background Alpha/Beta Counters, Level II) |
| Brand | CNC (China Nuclear Control System) |
|---|---|
| Origin | Beijing, China |
| Model | FJ427A1 |
| Instrument Type | Laboratory TLD Reader |
| Measurement Principle | Thermoluminescence (TL) Readout |
| Radiation Types | β, γ, X-ray, and thermal neutron (via appropriate TLD phosphors) |
| Detector | Photomultiplier Tube (PMT), operating voltage range: −400 V to −1000 V |
| Sample Form Compatibility | Solid dosimeters (square chips, discs, rods, powder) |
| Dose Range | 0.000–9999 arbitrary units (calibrated in µGy–Gy via TL phosphor-specific calibration) |
| Linearity Range | 100 µGy – 4 Gy (for JR1152A LiF:Mg,Ti chips irradiated with ⁶⁰Co γ-rays) |
| Linearity Deviation | ≤ ±10% within specified range |
| Heating Program | Three-stage linear ramp (preheat, readout, anneal) |
| max total duration | 500 s |
| preheat | RT → 500 °C at max rate |
| readout | variable ramp 0–40 °C/s, temp range up to 500 °C |
| anneal | ramp to 500 °C at max rate |
| Programmable Parameters | 5 independent parameter sets (including ramp profile, PMT HV, background offset, reference light source count rate, calibration factor, real-time clock) |
| Background Subtraction | Automatic, performed every 30 min during operation |
| Sensitivity Stability | ≤ ±5% over 8-h continuous operation |
| Compliance | Designed per GB 10264–1988 (Chinese National Standard for Thermoluminescent Dosimetry Systems) |
| Physical Dimensions | 445 mm (W) × 205 mm (D) × 420 mm (H) |
| Net Weight | 22 kg |
| Power Supply | AC 220 V, 50 Hz |
| Brand | CNCS (China Nuclear Control Systems) |
|---|---|
| Origin | Beijing, China |
| Model | BH1227 |
| Instrument Type | Laboratory-Based Liquid Activity Meter |
| Measurement Medium | Aqueous Samples |
| Detector Type | Plastic Scintillator (ST-1221) with CR120 PMT |
| Measurement Capability | Simultaneous Total Alpha and Total Beta Activity Concentration |
| Detection Efficiency | β: 0.5×10⁻²–3×10⁻² Bq (10–40 mBq·L⁻¹) |
| α | 5×10⁻⁴ Bq (5–20 mBq·L⁻¹) |
| Anti-coincidence Shielding | ST401 Plastic Scintillator + Three CR119 PMTs (Efficiency >99%) |
| Shielding | 75 mm Lead + 15 mm Steel Enclosure (Modular Two-Section Design) |
| Counting Area Options | Φ30 mm (177.5 px²), Φ45 mm (397.5 px²), Φ52 mm (525 px²) |
| Compliance | Meets GB/T 11682–2003 (Chinese National Standard for Low-Background Alpha/Beta Counters, Grade II) |
| Brand | CNCS (China Nuclear Control System) |
|---|---|
| Model | BH1324F |
| Detector Type | NaI(Tl) Scintillation Spectrometer |
| Energy Range | 50 keV – 2.0 MeV |
| Energy Resolution | ≤7.0% FWHM at 662 keV (with imported low-potassium Φ75×75 mm NaI(Tl) detector) |
| Background Count Rate | ≤160 cpm (50 keV–2.0 MeV) |
| Energy Linearity | ≤±1% (50 keV–2.0 MeV) |
| System Stability | ≤±1% over 8 h |
| MCA Channels | 512 / 1024 / 2048 / 4096 (software-selectable) |
| Max Counts per Channel | 2²⁴−1 |
| Integral Nonlinearity | ≤±0.1% (99.5% full scale) |
| Differential Nonlinearity | ≤±1% (99.5% full scale) |
| Channel Drift | ≤±1 channel over 8 h |
| HV Supply | 0–1500 V, manually adjustable, current limit 2 mA with overload/short-circuit protection |
| LV Supply | Overvoltage, overload and short-circuit protected |
| Preamplifier Gain | 0–160×, fixed shaping time 1 µs (optimized for NaI(Tl)) |
| Shielding | Lead castle (NG401-261), attenuation factor ≥80 (50 keV–2.0 MeV) |
| Software | UMS38 (MCA emulation & acquisition), WIN-NaI (gamma spectral analysis), fully compatible with Windows 98/Me/2000/XP/NT |
| Communication | RS-232 DMA interface, 912 kbps data transfer rate, no ISA slot required |
| Calibration Sources | Certified ²²⁶Ra, ²³²Th, ⁴⁰K single-nuclide standards + mixed standard (NIM traceable) |
| Compliance | ISO 9001 certified manufacturing |
| Detection Limit for Radon (activated charcoal method) | 6 Bq/m³ (average ambient air concentration) |
| Brand | CNCS |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | BH3103C |
| Instrument Type | Portable Dose Rate Meter |
| Radiation Type | X-ray and Gamma (γ) Radiation |
| Detector Type | Photomultiplier Tube (PMT) |
| Measurement Range | (1–10,000) × 10⁻⁸ Gy/h |
| Energy Response | 25 keV–48 keV (±40% max deviation) |
| Angular Response | ≤ ±15% (relative to max response, ¹³⁷Cs source, 0–150°) |
| Cosmic Ray Response | ±15% (vs. RS-111 ionization chamber) |
| Inherent Dose Rate Indication Error | ≤ ±10% |
| Operating Temperature | −10 °C to +40 °C |
| Power Consumption | ~400 mW |
| Battery | Ni-MH rechargeable |
| Environmental Compliance | Designed for field-deployable environmental and occupational radiation monitoring per IEC 60846-1:2014 and ISO 4037-3:2019 reference conditions |
| Brand | CNCS |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | BH3105E |
| Instrument Type | Portable |
| Instrument Class | Neutron Dose Rate Meter |
| Measured Medium | Gaseous Environment |
| Detector Type | ⁶Li-Glass Scintillator |
| Radiation Type | Neutron |
| Measurement Range | 0.1 µSv·h⁻¹ to 100.0 mSv·h⁻¹ |
| Sensitivity | 5 cps per µSv·h⁻¹ |
| Energy Response | Thermal neutrons to 14 MeV |
| γ-Ray Rejection Ratio | >100:1 in 10 mGy·h⁻¹ ¹³⁷Cs field |
| Angular Dependence | ±25% over 0°–±90° |
| Intrinsic Error | –50% to +100% |
| Typical Measurement Uncertainty | ±15% |
| Response Time | 20 s |
| Power Consumption | ≤500 mW |
| Compliance | IEC 61005, CMC Certified (China Metrology Accreditation), GB/T 10257–2001, Patent No. ZL92225959.3 |
| Brand | CNCS |
|---|---|
| Origin | Beijing, China |
| Model | BH3206B |
| Instrument Type | Portable Radiation Detector |
| Measurement Type | Alpha/Beta Counting |
| Detector | ZnS(Ag)-loaded plastic scintillator |
| Effective Detection Area | 170 cm² |
| Alpha Detection Efficiency | ≥35% (2π geometry, ²³⁹Pu source, φ50 mm aperture) |
| Beta Detection Efficiency | ≥40% (2π geometry, ⁹⁰Sr–⁹⁰Y source, φ50 mm aperture) |
| Background Count Rate | α ≤ 0.1 cps, β ≤ 15 cps |
| Counting Range | 1–10⁶ counts |
| Measurement Time | 1–16,000 s (user-selectable) |
| Stability | ±10% over 8 h (for counts >1000, using ²³⁹Pu and ⁹⁰Sr–⁹⁰Y standards) |
| Relative Error | <20% across full measurement range |
| Cross-Talk Ratio | α→β <15%, β→α <5% |
| Operating Temperature | 0–40 °C |
| Relative Humidity | ≤90% at 40 °C |
| Power Supply | Rechargeable battery pack with dedicated charger |
| Brand | CNCS (China Nuclear Control System) |
|---|---|
| Origin | Beijing, China |
| Model | FD125 |
| Detection Principle | ZnS(Ag)-based Scintillation Counting |
| Measurement Targets | Radon-222 (²²²Rn), Thoron-220 (²²⁰Rn), and Radium-226 (²²⁶Ra) in air, water, ore, and underground environments |
| Scintillation Chamber | Dual hemispherical acrylic chambers coated with ZnS(Ag) |
| Background Count Rate | ≤100 cps (unexposed chamber) |
| Leak Rate | ≤1.33×10³ Pa/10 min at residual pressure of 1.33×10⁴ Pa |
| Repeatability Error | ≤±10% under optimal conditions |
| Environmental Operating Range | 0–45°C, up to 95% RH |
| Power Supply | +9–10 V DC for amplifier |
| Weight | 16 kg (excluding scaler unit) |
| Brand | CNCS |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | ZK1101 Portable Multi-Channel Gamma Spectrometer |
| Instrument Type | Portable Gamma Spectrometer |
| Measurement Medium | Solid Samples |
| Detector Options | 2″ & 3″ NaI(Tl) Scintillation Detectors |
| Spectral Length | Software-Selectable (256, 512, 1024, or 2048 Channels) |
| Energy Resolution | ≤7% at 662 keV (¹³⁷Cs) |
| Channel Capacity | 2³²−1 (4,294,967,295 counts per channel) |
| Long-Term Stability | ≤1% channel shift over 8 h continuous operation |
| Battery Life | >8 h on integrated rechargeable Li-ion battery |
| Display | 7-inch capacitive touchscreen |
| Data Storage | MicroSD card (pre-installed, high-capacity) |
| Connectivity | USB 2.0 for PC data transfer |
| Software | Embedded real-time analysis firmware with lifetime free updates |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | 5-0102 |
| Pricing | Available Upon Request |
| Capacity | 12 or 24 × 16 mm digestion tubes |
| Temperature Range | 30–200 °C |
| Temperature Stability | ±0.1 °C @ 100 °C |
| Temperature Uniformity | ±0.1 °C @ 100 °C |
| Temperature Accuracy | ±0.1 °C @ 100 °C |
| Control System | Microprocessor-based digital temperature control |
| Heating Time to 100 °C from ambient | 15 ± 2 min |
| Over-Temperature Cutoff | 212 °C |
| Timer Range | 0–999 min |
| Power Supply | 220 V AC |
| Safety Certification | CE |
| Compatible Analyzers | CODPlus COD Analyzer, SMART2 Multi-parameter Water Analyzer, SMART Spectro Spectrophotometer |
| Brand | Cole-Parmer |
|---|---|
| Model | 601SP |
| Detection Range | 100–3000 ppm CO₂ |
| Origin | Japan |
| Tube Type | Colorimetric Gas Detection Tube |
| Application | Compressed air systems (cylinders, tanks, pipelines) |
| Packaging | Single tube, individually sealed |
| Brand | Cole-Parmer |
|---|---|
| Origin | USA |
| Model | 81973-20 |
| Instrument Type | Portable |
| Detection Target | CO₂ (multi-component capable) |
| Range | 0–50,000 ppm (0–5% v/v) |
| Resolution | 100 ppm (0.01%) |
| Accuracy | ±5% of reading or ±50 ppm, whichever is greater |
| Response Time | < 60 s (T₉₀) |
| Zero Drift | < ±20 ppm/week |
| Span Drift | < ±2% of full scale/month |
| Operating Temperature | 0–50 °C |
| Battery Life | 8 h (NiCd rechargeable) |
| Weight | 0.7 kg |
| Dimensions | 66.7 × 139.7 × 20.6 mm (L × H × W) |
| Data Storage | 850 records (non-volatile memory) |
| Communication | IR interface + RS232 (optional cable 81973-60) |
| Alarm | Visual (LED) and audible (variable-tone) at user-configurable thresholds (e.g., 5,000 ppm intermittent / 10,000 ppm continuous) |
| Sensor Type | Dual-wavelength non-dispersive infrared (NDIR) with integrated pressure & temperature compensation |
| Brand | Cole-Parmer |
|---|---|
| Origin | USA |
| Model | 86494-15, 86494-25, 86494-35, 86494-40, 86494-45 |
| Type | Portable |
| Detection Targets | O₂, CO, CO₂, NO, NO₂, NOₓ, SO₂, Draft Pressure, Flue Gas Temperature, Ambient Temperature |
| O₂ Range | 0–25% vol (0.1% res, ±0.2% vol) |
| CO Range | 0–8000 ppm (1 ppm res |
| CO₂ Range | 0–99.9% vol (0.1% res) |
| NO Range | 0–4000 ppm (1 ppm res |
| NO₂ Range | 0–1000 ppm (1 ppm res |
| SO₂ Range | 0–4000 ppm (1 ppm res |
| NOₓ Range | 0–5000 ppm (1 ppm res) |
| Draft Pressure | ±0–40" H₂O (0.001" H₂O res, ±5% of reading) |
| Flue Gas Temp | –23 to 1000°C (0.1°C res, ±1°C) |
| Ambient Temp | –23 to 100°C (0.1°C res, ±1°C) |
| Combustion Efficiency | 0–100% (0.1% res) |
| Exhaust Flow | ≥1.00 (0.01 res) |
| Fuel Library | 10 preloaded fuels (natural gas, propane, butane, No. 2/4/6 fuel oil, wood, coal) |
| Data Logging | Up to 600 records |
| Power | Rechargeable battery + AC adapter (9 hrs operation without printing) |
| Communication | RS-232 (86494-15/-25), USB (86494-35/-40/-45) |
| Included | Dual-channel sampling hose (10 ft), 12" metal probe, factory-calibrated sensors, calibration certificate, non-thermal printer paper, rubber feet, carrying case |
| Brand | Cole-Parmer |
|---|---|
| Origin | USA |
| Model | FSB-200-P |
| Temperature Range | 50°C to 700°C |
| Max. Heating Power | 3000 W (240 V) |
| Air Pressure | 420 kPa (60 psi) |
| Max. Air Flow | 127 L/min |
| Chamber Dimensions | 165 mm Ø × 385 mm depth |
| Net Weight | 76 kg |
| Short-Term Temp Stability @ 50°C | ±0.2°C |
| Short-Term Temp Stability @ 600°C | ±0.3°C |
| Long-Term Temp Stability @ 600°C | ±0.5°C |
| Display Resolution | 1°C |
| Control System | Type 3 PID with K-type thermocouple |
| Required Media | Alundum® alumina particles (BROWN/ALO) |
| Brand | Cole-Parmer |
|---|---|
| Origin | USA |
| Model | 86384-05, 86384-15 |
| CO₂ Range | 0–5000 ppm |
| CO Range (86384-15 only) | 0–500 ppm |
| RH Range | 5–95% |
| Temperature Range | 0–60 °C |
| CO₂ Resolution | 1 ppm |
| CO Resolution | 0.1 ppm |
| RH Resolution | 0.1% |
| Temp Resolution | 0.1 °C / 0.1 °F |
| CO₂ Accuracy | ±3% of reading or ±50 ppm |
| CO Accuracy | ±3% of reading or ±3 ppm |
| RH Accuracy | ±2% |
| Temp Accuracy | ±0.6 °C (±1.0 °F) |
| Data Storage Capacity (86384-15) | 26,900 timestamped records |
| Power | 4 × AA batteries or 115 VAC adapter (included with 86384-15) |
| Operating Ambient Temp | 5–70 °C |
| Dimensions | 10.2 × ? × 3.8 cm (L × H × W |
| Weight | 0.4 kg (86384-05), 0.5 kg (86384-15) |
| Software | LogDat 2™ for Windows (≥3.1), LogDat 2 Companion for Excel |
| Brand | Cole-Parmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | SC4200 |
| Pricing | Upon Request |
| Brand | Cole-Parmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 86515-20 |
| Measurement Principle | Electrochemical (O₂, CO, H₂S) & Catalytic Bead (Combustible Gas) |
| Measured Gases | O₂, CO, H₂S, LEL (Methane/Propane Equivalent) |
| Detection Ranges | O₂ (0–25% vol), CO (0–2000 ppm), H₂S (0–200 ppm), LEL (0–100% LEL) |
| Resolution | O₂ (0.1% vol), CO/H₂S (1 ppm), LEL (1% LEL) |
| Alarm Setpoints | O₂ (Low: 19.5%, High: 23.5%), CO (Low: 35 ppm, High: 50 ppm), H₂S (Low: 10 ppm, High: 20 ppm), LEL (Low: 10% LEL, High: 20% LEL) |
| Alarm Output | Audible (90 dB @ 1 ft), Visual (180° LED array), Vibratory |
| Data Logging | Internal memory with IR interface for PC download |
| Battery | Two AA alkaline cells (12 h typical runtime) |
| Weight | 7.8 oz (0.22 kg) |
| Enclosure Rating | IP67 |
| Certifications | UL/cUL Class I, Div 1, Groups A–G, T4 |
| Sensor Life | 5 years (typical) |
| Brand | Cole-Parmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | Imported |
| Model | 86515-30 |
| Measurement Principle | Electrochemical (O₂, CO, H₂S) & Catalytic Bead (LEL) |
| Measured Gases | O₂ (0–25% vol), CO (0–2000 ppm), H₂S (0–200 ppm), Combustible Gas (0–100% LEL) |
| Resolution | O₂: 0.1% vol |
| CO | 1 ppm |
| H₂S | 1 ppm |
| LEL | 1% LEL |
| Alarm Setpoints | O₂: Low 19.5%, High 23.5% |
| CO | Low 35 ppm, High 50 ppm |
| H₂S | Low 10 ppm, High 20 ppm |
| LEL | Low 10%, High 20% |
| Audible Alarm | 90 dB @ 1 ft |
| Visual Alarm | Dual high-intensity LEDs |
| Tactile Alarm | Vibration motor |
| Ingress Protection | IP65 |
| Certifications | UL/cUL Class I, Div. 1, Groups A–G, T4 |
| Sensor Life | 2 years |
| Battery Life | 12 h (pump mode), 24 h (diffusion mode) |
| Power | Two AA alkaline or rechargeable NiMH batteries |
| Weight | 19.4 oz (0.55 kg) |
| Dimensions | 5.5" W × 3.5" H × 2.25" D |
| Display | Backlit LCD |
| Data Logging | None |
| Compliance | Meets requirements for confined space entry per OSHA 1910.146 and ANSI/ASSP Z240.1 |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | R280 |
| Instrument Type | Portable Dose Rate Meter |
| Radiation Types Detected | Beta (β), Gamma (γ), and X-rays |
| Detector Type | Halogen-Quenched Geiger-Müller Tube |
| Measurement Range (Dose Rate) | 0.01 µSv/h – 1000 µSv/h |
| Sensitivity | ≥10⁸ counts per µSv/h (for ⁶⁰Co, 1.25 MeV) |
| Energy Response Threshold | β ≥ 0.2 MeV, γ/X ≥ 0.02 MeV |
| Operating Temperature | −40 °C to +75 °C |
| Dimensions | 190 mm × 88 mm × 40 mm |
| Weight | 500 g |
| Power Supply | 9 V alkaline battery (IEC 6LR61) |
| Data Storage Capacity | 2000 records (manual or auto-triggered) |
| Compliance | CE (EN 61000-6-3, EN 61000-6-2), FCC Part 15 Subpart B |