Environmental Monitoring Instruments
Filter
Showing 1381–1410 of 2621 results
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | QCD |
| Pricing | Available Upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Model | RC-1000/2000 |
| Pricing | Available Upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM/ODM Producer |
| Country of Origin | China |
| Model | SG-100 |
| Pricing | Available Upon Request |
| Brand | FPI (Focus Photonics Inc.) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | TOFMS-100 |
| Detection Principle | Single-Photon Ionization Time-of-Flight Mass Spectrometry (SPI-TOFMS) |
| Instrument Type | Continuous Online Analyzer |
| Configuration | Integrated VOC Monitoring System with GIS-enabled Mobile Deployment Capability |
| Detection Range | 0.1 ppb – 1000 ppm (v/v) |
| Mass Resolution | >800 (FWHM at m/z 92) |
| Accuracy | < ±1% Full Scale (0–500 ppb) |
| Response Time | ≤1 s (T90) |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer | FPI (Hangzhou) Co., Ltd. |
| Model | TOX-2000 |
| Dimensions | 0.60 m × 0.55 m × 1.00 m (L×W×H) |
| Weight | 60 kg |
| Power Supply | 220 V ±10%, 50 Hz ±1% |
| Operating Temperature | 10–30 °C ambient |
| Water Temperature | 0–40 °C (non-freezing) |
| Response Time | <5 min |
| Detectable Toxic Substances | >5,000 compounds including heavy metals, pesticides, herbicides, biocides, and industrial chemicals |
| Sensitivity (EC₅₀) | HgCl₂ < 0.2 mg/L |
| Repeatability | RSD < 5% |
| Bacterial Cartridge Lifespan | 30 days |
| Data Logging Interval | Configurable down to 1 s |
| Output Signals | 4–20 mA analog |
| Toxicity Classification Levels | 5-tier scale (Low, Moderate, High, Severe, Extreme) |
| Compliance | ISO 11348-3 (Vibrio fischeri luminescence inhibition test) |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | TPN-2000 |
| Instrument Type | Online Analyzer |
| Measurement Principle | High-Temperature/High-Pressure Alkaline Potassium Persulfate Digestion + UV Spectrophotometry |
| Measurement Range | 0–0.5 / 0–2 / 0–5 mg/L (selectable) |
| Accuracy | ±10% of reading |
| Detection Limit | 0.005 mg/L |
| Compliance | HJ 636–2012 |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | V-1000 |
| Instrument Category | Meteorological Visibility Sensor |
| Measurement Principle | Infrared Forward Scatter at 42° |
| Range | 10–30,000 m |
| Operating Environment | All-weather, including fog, rain, snow, and freezing conditions |
| Power Consumption | Low-power design for remote deployment |
| Calibration Option | Compatible with FPI Model 28678 Field Calibration Kit |
| Enclosure | Integrated Heated Housing to Prevent Condensation and Ice Accumulation |
| Airflow Management | Aerodynamically Optimized Sensor Geometry to Minimize Flow Disturbance |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | VOC-3000 |
| Pricing | Upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | WAGA |
| Configuration | Online Continuous Monitoring System |
| Measurement Principle | Wet-Chemical Extraction Coupled with Ion Chromatography (IC) |
| Instrument Type | Online Multicomponent Aerosol Ion Analyzer |
| Compliance | Designed for ambient air quality monitoring per Chinese HJ 653–2013 and compatible with ISO 12884, EN 14902, and US EPA OTM-33A method frameworks |
| Brand | FPI (Fortune Photonics Instrumentation) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM/ODM) |
| Model | WCS-3000 |
| Power Supply | 220 V AC |
| Operating Temperature | 5–45 °C |
| Relative Humidity | 0–95 % RH (non-condensing) |
| Enclosure Rating | IP65 |
| Impact Resistance | IK08 |
| Display | 7" TFT LCD touchscreen (800 × 480 resolution, LED backlight, 154 × 86 mm visible area) |
| Communication | RS485, Modbus RTU protocol |
| Data Storage | ≥1 year local history (timestamped, non-volatile) |
| Dimensions | 235 × 185 × 117 mm (W × H × D) |
| Housing Material | Flame-retardant polycarbonate (UL94-V0 certified) |
| Analog Outputs | None |
| Relay Outputs | None |
| Digital I/O | RS485 only |
| Expandable Probes | Optional integration of phycocyanin (blue-green algae), chlorophyll-a, and UV-absorbance-based COD estimation sensors |
| Brand | FPI (Focus Photonics Inc.) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | WPR-Series |
| Laser Source | Not applicable (UHF/VHF passive radar principle) |
| Detector | Coherent pulsed Doppler receiver with 16-bit A/D sampling |
| Operating Frequency Band | UHF (915 MHz) or VHF (50 MHz typical, configurable) |
| Maximum Detection Altitude | Up to 12 km (dependent on frequency band and atmospheric conditions) |
| Pulse Repetition Frequency (PRF) | Configurable, typically 100–2,000 Hz |
| Measurement Parameters | Horizontal wind vector (u/v), vertical velocity (w), virtual temperature gradient, refractivity structure parameter (Cn²) |
| Compliance | Designed per MIL-STD-810G environmental ruggedization |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | WIZ Probe |
| Instrument Type | Online Water Quality Analyzer |
| Deployment Method | Buoy-Mounted In-Situ Monitoring System |
| Measurement Principle | Wet-Chemical Spectrophotometry (UV-Vis) + Fluorescence (for NH₃-N) |
| Configurable Parameters | NH₃-N, PO₄-P, NO₃⁻+NO₂⁻-N, NO₂⁻-N (standard) |
| Power Supply | Integrated Solar/Battery System via WIZbuoy Platform |
| Data Logging & Remote Access | WIZlog Data Logger with Cellular/GPRS or LoRaWAN Connectivity |
| Compliance Framework | Designed for ISO 5667 series (water sampling), ASTM D3370 (in-situ sampling), and compatible with EPA Method 353.2 (nitrate/nitrite), EPA 365.1 (phosphate), EPA 350.1 (ammonia), and EU WFD (Water Framework Directive) monitoring requirements |
| Key | Brand: FPI (Focus Photonics Inc.) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | FPI-PSA |
| Pricing | Available Upon Request |
| Brand | Fulit |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | FLV 600 |
| Detection Principle | Flame Ionization Detection (FID) |
| Instrument Type | Online Analyzer |
| Configuration | Multi-component VOCs Analyzer |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GA-S |
| Pricing | Upon Request |
| Brand | CASP |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GA2202 |
| Detection Gases | Methane (CH₄), Ethane (C₂H₆) |
| Detection Principle | Mid-Infrared Absorption + Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Response Time | <1 s |
| Measurement Speed | Up to 60 km/h mobile survey |
| Dual-Gas Simultaneous Quantification | Yes |
| Operating Temperature Control | Active Thermostatic Stabilization |
| Measurement Range | Wide-range configurable for urban ambient monitoring, station boundary monitoring, and landfill/anaerobic digester plume tracking |
| Data Security & Support | Fully domestic R&D and manufacturing, local service network |
| Brand | GAINWAY |
|---|---|
| Model | GW-2081 |
| Origin | Hubei, China |
| Instrument Type | Online CEMS |
| Detection Target | Multi-component gases (CO₂, CH₄, N₂O, CO, O₂) |
| Measurement Ranges | 0–50 ppm (N₂O), 0–1000 ppm (CH₄), 0–20% (CO₂) |
| Response Time | <60 s |
| Flow Rate | 800 mL/min (standard), up to 3000 mL/min (dust-free) |
| Operating Temperature | 15–35 °C |
| Dimensions | 800 mm × 850 mm × 2000 mm (L×W×H) |
| Weight | 125 kg |
| Max Power Consumption | 1200 W |
| Zero Drift (24 h) | ≤0.10% FS (CO₂), ≤1 ppm (CH₄), ≤0.2 ppm (N₂O) |
| Span Drift (24 h) | ±1% FS |
| Flow Velocity Range | 0–40 m/s |
| Temperature Range | 0–300 °C |
| Humidity Range | 0–40% RH |
| Detection Principle | Gas Filter Correlation (GFC) + Long-Path Absorption Cell (L-Cell) for CH₄/N₂O |
| Brand | Galvanic |
|---|---|
| Origin | Canada |
| Model | 903W |
| Instrument Type | Online Gas Analyzer |
| Target Gas | Hydrogen Sulfide (H₂S) |
| Response Time (T₉₀) | < 20 s |
| Measurement Accuracy | ±10 ppb (LOD) |
| Measurement Range | 0–2000 ppm (undiluted) |
| Linearity | ±1% FS |
| Repeatability | ±1% FS (>1 ppm), ±2.5% FS (<1 ppm) |
| Operating Temperature | 10–50 °C |
| Power Input | 90–240 VAC / 10–36 VDC |
| Certifications | CSA C/US, Class I, Div 2, Groups B, C, D, T3 |
| Brand | Galvanic |
|---|---|
| Origin | USA |
| Model | Accuseies Series |
| Measurement Principle | Colorimetric Titration with Dual-Wavelength Photometric Endpoint Detection (650 nm / 810 nm) |
| Range Options | 0–20 mg/L or 0–500 mg/L H₂SO₄ |
| Accuracy | ±1% of full scale |
| Linearity | ±1% FS |
| Repeatability | ±1% RSD |
| Analysis Cycle Time | 15 min per sample |
| Sample Flow Rate | 200 mL/min |
| Max Sample Pressure | <5 psi |
| Suspended Solids Limit | <1,000 µm |
| Operating Temperature | −20 °C to +60 °C |
| Dimensions | 1016 mm (H) × 406 mm (W) × 241 mm (D) |
| Weight | 45.3 kg |
| Power Supply | 24 VDC or 90–240 VAC |
| Enclosure Rating | NEMA 4X (IP65) |
| Communication | 4–20 mA, Modbus RTU (RS232/RS485), Modbus TCP/IP, USB, Ethernet |
| Digital I/O | 8 programmable dry/wet contacts (24 VDC) |
| Analog Outputs | Up to 8 isolated 4–20 mA loops (self-powered) |
| Sample Interface | 1/4″ compression fitting |
| Environmental Resistance | H₂S- and Cl₂-resistant materials |
| System Architecture | Physically isolated electronic control unit and wet chemistry module |
| Brand | Galvanic |
|---|---|
| Origin | USA |
| Model | Accuseries LPA Online Analyzer |
| Instrument Type | Online Chloride Analyzer |
| Measurement Range | 0–50 ppm |
| Detection Limit | 0.1 ppm |
| Response Time | 8 min |
| Accuracy | ±1% of reading |
| Operating Temperature Range | −20 °C to +60 °C |
| Communication Interfaces | 4–20 mA, Modbus TCP/IP, RS232, RS458, USB, GUI PC Direct Connection, Relay Outputs |
| Sample Streams | Up to 6 independent flow paths |
| Analytical Method | Potentiometric Titration |
| Enclosure Rating | IP65 (corrosion-resistant, H₂S/Cl₂ tolerant, moisture-proof) |
| Service Life | Designed for continuous 24/7 operation with automated reagent management |
| Brand | Galvanic |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Accuseries LPA Online Analyzer |
| Instrument Type | Online Multi-Ion Analyzer |
| Measurement Range | 0–500 mg/L |
| Detection Limit | 1 ppm |
| Response Time | 10 min |
| Accuracy | ±1% of reading |
| Operating Temperature Range | −20 °C to +60 °C |
| Measurement Principle | Potentiometric Titration |
| Communication Interfaces | 4–20 mA, Modbus TCP/IP, RS232, RS485, USB, GUI PC Direct Connection |
| Relay Outputs | Yes |
| Sample Streams | Up to 6 modular flow paths |
| Enclosure Rating | IP65 (corrosion-resistant, H₂S/Cl₂ tolerant, moisture-proof) |
| Automation Level | Fully Automated (auto-calibration, auto-cleaning, reagent replenishment, 24/7 unattended operation) |
| Brand | Galvanic |
|---|---|
| Origin | USA |
| Model | Accuseries LPA Online Analyzer |
| Instrument Type | Online Sodium Ion Analyzer |
| Measurement Range | 0–10,000 ppb |
| Detection Limit | 0 ppb |
| Response Time | 10 min |
| Accuracy | ±1% of reading |
| Operating Temperature | −20 to +60 °C |
| Communication Interfaces | 4–20 mA, Modbus TCP/IP, RS232, RS485, USB, GUI PC Direct Connection |
| Sample Streams | Up to 6 modular flow paths |
| Compliance | Designed for continuous operation in industrial water monitoring per ASTM D4192, ISO 10523, and USP <643> guidance for sodium in purified water systems |
| Brand | Galvanic |
|---|---|
| Origin | USA |
| Model | Accuseries |
| Type | Online Multi-Ion Analyzer |
| Measurement Accuracy | ±1% FS |
| Linearity | ±1% FS |
| Repeatability | ±1% FS |
| Response Time | 8–12 min |
| Operating Temperature Range | −20 °C to +60 °C |
| Dimensions | 1016 mm × 406 mm × 241 mm |
| Weight | 45.3 kg |
| Power Supply | 10–32 VDC or 90–240 VAC |
| Power Consumption | 300 W |
| Analog Outputs | up to eight 4–20 mA |
| Communication Protocols | Modbus RTU (RS-232/RS-485), Modbus TCP/IP |
| Brand | Galvanic |
|---|---|
| Origin | USA |
| Model | Accuseries-LPA Online Analyzer |
| Instrument Type | Online Multi-Ion Analyzer |
| Measurement Range | 0–200 ppb (as Ca²⁺/Mg²⁺) |
| Detection Limit | <1 ppb (typical, method-dependent) |
| Response Time | ≤10 min (T90) |
| Accuracy | ±1% of reading |
| Operating Temperature | −20 to +60 °C |
| Communication Interfaces | 4–20 mA, Modbus TCP/IP, RS232, RS485, USB, GUI PC Direct Connection, Relay Outputs |
| Sample Flow Paths | Up to 6 independent streams (modular configuration) |
| Enclosure Rating | IP65 (corrosion-resistant housing, H₂S/Cl₂ tolerant) |
| Brand | Galvanic |
|---|---|
| Origin | USA |
| Model | Accuseries-LPA Online Analyzer |
| Type | Online Analyzer |
| Measurement Principle | Pyrazolone-based Colorimetric Method |
| Detection Range | 0–1 ppm CN⁻ |
| Communication Interfaces | 4–20 mA, Modbus TCP/IP, RS232, RS485, USB, GUI PC Direct Connection, Relay Outputs |
| Sample Handling | Up to 6 Independent Flow Paths |
| Enclosure Rating | Corrosion-Resistant Design (H₂S/Cl₂ Resistant, Humidity-Protected) |
| Compliance | Designed for Continuous Emission Monitoring Systems (CEMS) and Industrial Wastewater Compliance Applications |
| Brand | Galvanic |
|---|---|
| Origin | USA |
| Model | Accuseries-LPA |
| Instrument Type | Online Analyzer |
| Measurement Principle | Molybdenum Blue Colorimetric Method |
| Range | 0–5000 ppb SiO₂ (as soluble silica) |
| Communication Interfaces | 4–20 mA, Modbus TCP/IP, RS232, RS485, USB, GUI PC Direct Connection, Relay Outputs |
| Sample Flow Paths | Up to 6 modular channels |
| Environmental Rating | Corrosion-resistant housing |
| Compliance | Designed for continuous operation in industrial water monitoring per ASTM D859, ISO 10530, and EPA Method 365.3 contexts |
| Brand | Komyo Rikagaku |
|---|---|
| Origin | Japan |
| Model Numbers | 106SC (CO), 126SF (CO₂), 177UR (H₂O vapor) |
| Detection Principle | Colorimetric Length-of-Stain |
| Pump | AP-20 Manual Bellows Pump |
| Calibration Traceability | NIST-traceable standards |
| Compliance | ASTM D3928, ISO 8573-3 (for compressed gas purity verification), JP XVIII General Chapter 2.40 |
| Brand | Junfang Physical & Chemical |
|---|---|
| Model | PQX-2002 |
| Chamber Volume Options | 25 L, 50 L, 100 L (custom sizes available) |
| Dimensions (L×W×H) | 470×335×207 mm / 670×470×207 mm / 1020×520×224 mm |
| Material | Optical-grade acrylic (PMMA) |
| Power Supply | AC 220 V, 50 Hz |
| Integrated Features | Digital温-humidity display, internal fan-assisted homogenization, pure gas inlet ports, exhaust valve, glove ports (built-in rubber gloves), analytical instrument interface ports |
| Compliance | Designed to meet GB 15322–2019 requirements for alarm activation value testing of combustible and toxic gas detectors |
| Brand | -- |
|---|---|
| Origin | UK |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Gas-Pro |
| Pricing | Upon Request |
| Detection Principle | Electrochemical, Photoionization (PID), Infrared (IR) |
| Form Factor | Portable |
| Response Time (T90) | 2 s (electrochemical toxic gases), 20 s (CH₄), 10 s (O₂), 30 s (IR) |
| Repeatability | ±2% of reading (typical for H₂S, CO, SO₂, VOCs, combustibles) |
| Brand | Cubic Instruments |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-2301 |
| Measurement Principle | Non-Dispersive Ultraviolet (NDUV) Absorption |
| Range | 0–500/0–1000 ppm (customizable) |
| Resolution | 1 ppm |
| Accuracy | ±25 ppm or ±4% of reading (whichever is greater) |
| Repeatability | ±20 ppm or ±3% of reading (whichever is greater) |
| Response Time (T₉₀) | ≤4.5 s |
| Operating Temperature Compensation | Integrated PID-controlled heater with real-time temperature & pressure correction |
| Output Interface | Analog (4–20 mA / 0–5 V) and digital (RS485 Modbus RTU) |
| Humidity Immunity | Validated under RH 0–95% non-condensing |
| Direct NO₂ Detection | Yes (no NOₓ converter required) |
