| Brand | Hidex |
|---|---|
| Origin | Finland |
| Model | AMG |
| Detector | 3-inch diameter NaI(Tl) scintillation crystal |
| Energy Range | 15–2000 keV |
| Multichannel Analyzer (MCA) | 2048-channel linear |
| Energy Resolution | <30% FWHM at 27.5 keV (¹²⁵I), <30% FWHM at 39.6 keV (¹²⁹I), <9.5% FWHM at 662 keV (¹³⁷Cs) |
| Sample Capacity | 250 positions for 13 mm-diameter vials |
| Shielding | 55 mm lead equivalent overall |
| Dimensions (W×D×H) | 640 × 700 × 600 mm |
| Brand | Hidex |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Hidex Triathler |
| Pricing | Upon Request |
| Weight | 9 kg (20 lbs) |
| Power Supply | 110–240 V AC, 12 V DC |
| Sample Formats | LSC vials, test tubes, microcentrifuge tubes |
| Detector | Single-photon-counting photomultiplier tube (PMT) |
| Display | 2×16-character LCD |
| Energy Range | 2 keV – 2,000 keV |
| Counting Time | 0.1 s – 99,999 min |
| Output Interfaces | RS-232C, USB |
| Brand | Avantium |
|---|---|
| Origin | Netherlands |
| Model | High Throughput DAC Systems |
| Instrument Type | Online Analyzer |
| Detection Target | Multi-component Gas Streams |
| Repeatability | ±0.1% |
| Flow Control Technology | Microfluidic Distribution |
| Parallel Channels | 8 |
| Column Operating Temperature (Adsorption) | 10–30 °C (SD ≤0.5 °C across columns) |
| Column Pre-treatment Temperature | Up to 150 °C |
| Isothermal Zone Length | 16 cm per column group |
| Heating Architecture | Dual independent temperature-controlled enclosures (4 columns per enclosure) |
| Sample Volume Range | 0.1–2.0 mL |
| Pressure Operation | Ambient |
| Brand | HJ (Hujing Purification) |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | Y09-010 |
| Power Supply | AC 220 V, 50 Hz |
| Internal Tank Capacity | 2500 mL (Optimal Fill: 1200 mL) |
| Dimensions (L×W×H) | 280 × 265 × 300 mm |
| Net Weight | 9 kg |
| 雾化部件输入电压 | DC 45 V |
| Rated Power Consumption | 210 W |
| Fog Generation Rate | ≥5500 mL/h |
| Aerosol Output Flow Rate | 0.95 m³/min |
| Droplet Size Distribution | 1–10 µm (≥80% mass concentration within range) |
| Optimal Water Level for雾化 | 28 mm |
| Visible Plume Height | 120–150 mm |
| Compatible Water Conductivity Range | 0.15–1.00 mS/cm |
| Continuous Operation Duration | ≥50 min |
| Noise Level | Low (≤52 dB(A) at 1 m) |
| 雾化管 Compatibility | Yes (up to 2 m extension for curtain-type aerosol delivery) |
| Brand | Holaday |
|---|---|
| Origin | USA |
| Model | HI3604 |
| Frequency Range | 30–2000 Hz |
| Electric Field Range | 1 V/m – 200 kV/m |
| Magnetic Field Range | 0.2 mG – 20 G |
| Accuracy | ±1% (typical, referenced to NIST-traceable calibration) |
| Display | LCD with unit selection (mG, G, V/m, kV/m) and bar-graph visualization |
| Data Storage | 127 internal readings |
| Power | Two 9V alkaline batteries (NEDA 1604A) |
| Operating Temperature | 10–40 °C |
| Relative Humidity | 5–95% RH (non-condensing) |
| RMS Detection | True RMS for non-sinusoidal waveforms |
| Polarization Response | Single-axis (electric and magnetic sensors optimized for linear polarization alignment) |
| Output | Analog preamp output (1 mV per unit full scale) via 3.5 mm audio jack |
| Optional Digital Interface | Fiber-optic link compatible with HI-3616 remote control unit |
| Brand | Honegeagle |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | HNAG1000-4STS-T |
| Detection Principle | Electrochemical Sensing |
| Instrument Type | Fixed/Portable Hybrid (Wireless IoT-Enabled) |
| Response Time | T90 ≤ 10 s (gas-dependent, per selection table) |
| Gas Configuration | 1–6 interchangeable electrochemical sensors for combustible and toxic gases |
| Certifications | CNAS, CPA, SIL-2 compliant |
| Enclosure Rating | IP66 |
| Explosion Protection | Ex d IIB T6 / Ex d IICT6 |
| Compliance | GB 3836.1–2010, GB 3836.2–2010, GB 3836.15–2000, GB/T 50493–2019, GB 12358–2006, GBZ/T 223–2009, GBZ 2.1–2007, GB 4208–2008 |
| Brand | Honegeagle |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | HNAG1000-4SX-T |
| Price Range | USD 2,800 – 3,900 |
| Brand | Honegeagle |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Model | HNAG6200-NOX-T |
| Price Range | USD 1,520 – 2,370 |
| Brand | Honeywell BW |
|---|---|
| Origin | Canada |
| Model | Ultra |
| Type | Portable Multi-Gas Detector |
| Detection Capacity | 5 gases (4 standard + 1 optional) |
| Response Time | <1 second (T90) |
| Repeatability | ±2% of reading (typical, per sensor) |
| Dimensions | 14.8 × 8.5 × 4.0 cm |
| Weight | 411 g |
| Operating Temperature | −20 °C to +50 °C |
| Operating Humidity | 5–95% RH (non-condensing) |
| Ingress Protection | IP66/IP68 |
| Alarm Types | Visual (LED + large-dot matrix LCD), Vibration, Audible (95 dB) |
| Battery Life | Up to 18 h at −20 °C (14 h with PID or IR sensor) |
| Pump Suction Distance | 22.9 m |
| Data Logging | 30 alarm events + 10 bump test events |
| Certifications | CSA Class I, Div 1, Groups A–D |
| Key | Brand: Honeywell |
|---|---|
| Origin | USA |
| Model | LP-1200 |
| Type | Manual piston sampling pump (not a standalone gas analyzer) |
| Compatible With | Standard-length colorimetric gas detection tubes (e.g., Honeywell, Dräger, Gastec) |
| Sampling Volumes | 50 mL or 100 mL per stroke |
| Sealing Mechanism | Plug-type vacuum seal cylinder with conical rubber inlet tip |
| Visual Indicators | Gray-to-white window transition during sampling |
| Leak Check Procedure | Built-in 2-minute vacuum hold test (≤3 mm piston drift) |
| Maintenance | Replaceable rubber inlet tip, washable/replacement inlet filter, vacuum-lubricated piston assembly, serviceable one-way valve |
| Brand | Hongweiliangzi |
|---|---|
| Model | HW-YHS |
| ORP Range | −2000 to +2000 mV, Resolution: 0.1 mV, Accuracy: ±10 mV |
| pH Range | 0–14, Resolution: 0.1, Accuracy: ±0.05 |
| Temperature Range | 5–60 °C, Resolution: 0.1 °C, Accuracy: ±1 °C |
| Power Supply | DC 5 V / 2 A |
| Battery Capacity | 6000 mAh |
| Data Storage | 5 million records |
| Display | 3.5-inch color touchscreen |
| IP Rating | IP65 |
| Compliance | HJ 746–2015, SL 94–1994 |
| Brand | Horde Electric |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | HD-101 |
| Measurement Principle | Potassium Dichromate Oxidation–Spectrophotometric Method |
| Measurement Range | (15–1000) mg/L, (50–3000) mg/L, (200–10000) mg/L (expandable) |
| Zero Drift | ±5 mg/L |
| Span Drift | ±5% F.S. |
| Accuracy | ±10.0% of reading |
| Limit of Quantitation | 15 mg/L |
| Repeatability | ≤5.0% RSD |
| Cycle Time | ≤60 min |
| Insulation Resistance | >20 MΩ |
| MTBF | ≥720 h |
| Communication Interfaces | RS232 / RS485, 4–20 mA analog output |
| Dimensions (L×W×H) | 500 × 440 × 1440 mm |
| Weight | 55 kg |
| Display | 7-inch capacitive touchscreen |
| Controller | Industrial PLC-based embedded system |
| Operating Temperature | 5–40 °C |
| Operating Humidity | 20–85% RH (non-condensing) |
| Power Supply | AC 220 V ±25%, 50 Hz ±0.5 Hz |
| Rated Power Consumption | 100 W |
| Brand | Horde Electric |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HD-BTN |
| Price | USD 1,780 (FOB) |
| Measurement Method | Chromotropic Acid Spectrophotometry |
| Range | 0.5–200 mg/L |
| Resolution | 0.001 mg/L |
| Brand | Horde Electric |
|---|---|
| Origin | Shandong, China |
| Model | HD-HW100A |
| Instrument Type | Portable |
| Detection Principle | Non-Dispersive Infrared (NDIR) |
| Target Gas | Carbon Monoxide (CO) |
| Multi-Component Capability | Yes |
| Repeatability | ≤1.0% |
| Response Time (T90) | ≤90 s |
| Linearity Error | ≤±2% F.S. |
| Operating Temperature Range | -10°C to 50°C |
| Data Storage Capacity | >100,000 records |
| Battery Life | >8 h (fully charged) |
| Display | 7-inch capacitive touchscreen (Android OS) |
| Connectivity | Wi-Fi, USB host/device, cloud platform integration |
| Calibration Options | N₂ zeroing & catalytic zeroing |
| Environmental Compensation | Integrated temperature & humidity sensors with real-time algorithmic correction |
| Flow Measurement | Optional digital mass flow sensor |
| Data Output | ppm / mg/m³ (user-switchable) |
| Regulatory Compliance | JJG635–2011, HJ965–2018, GB/T18204.2–2014, GB9801–1988, GBZ/T300.37–2017 |
| Brand | Horde Electric |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | XRF-SL1 |
| Price | ¥118,000 |
| Instrument Type | Handheld |
| Detection Principle | X-Ray Fluorescence Spectrometry (XRF) |
| Operating Temperature | −20 °C to 50 °C |
| Brand | HORDE Electric |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | XRF-ST1 |
| Product Type | Handheld |
| Detection Principle | Energy-Dispersive X-Ray Fluorescence (EDXRF) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | APMA-370 |
| Instrument Type | Portable Gas Analyzer |
| Detection Target | Single-component (CO) |
| Measurement Range | 0–5 / 0–10 / 0–20 / 0–50 ppm (selectable) |
| Repeatability | ±1.0% F.S. |
| Response Time (T90) | ≤60 s (at lowest range) |
| Zero Drift | ±0.1 ppm/day or ±1.0% F.S./day (whichever is greater) |
| Span Drift | ±2.0% F.S./day or ±3.0% F.S./week |
| Linearity Error | ±1.0% F.S. |
| Detection Limit | 0.05 ppm (2σ, for ranges ≤10 ppm) |
| Sample Flow Rate | ~1.5 L/min |
| Operating Temperature | 5–40 °C |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Dimensions | 430 × 550 × 221 mm (W×D×H) |
| Weight | ~16 kg |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | APNA-370(G) |
| Instrument Type | Online Continuous Emission Monitor |
| Measured Gases | Nitric Oxide (NO), Nitrogen Dioxide (NO₂), Total Nitrogen Oxides (NOₓ) |
| Response Time (T90) | ≤120 s |
| Detection Limit | 0.5 ppb (2σ, ≤0.2 ppm range) / 1.0% F.S. (2σ, >0.2 ppm range) |
| Measurement Range | 0–10 ppm (4 selectable sub-ranges, max span ratio 10:1) |
| Accuracy | ±1.0% F.S. (linearity & repeatability) |
| Zero Drift | ±1.0 ppb/day or ±1.0% F.S./day (whichever greater) |
| Span Drift | ±1.0% F.S./day |
| Sample Flow Rate | ~0.8 L/min |
| Operating Temperature | 5–40 °C |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Dimensions | 430 × 550 × 221 mm (W×D×H) |
| Weight | ~21 kg |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | ENDA-640ZG Series |
| Instrument Type | Flue Gas CEMS |
| Accuracy | ±1.0% F.S. |
| Repeatability | ±0.5% F.S. |
| Response Time (SO₂) | 60–240 s |
| Stability | ±2.0% F.S./week |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | GA-370 |
| Measurement Principle | Dual-Beam Alternating Flow Modulated NDIR |
| Response Time | ≤ 180 s |
| Detection Limit | 10 ppb (for CO, CO₂, CH₄) |
| Gas Compatibility | N₂, O₂, He, Ar, H₂, Air |
| Compliance Notes | Designed for use in ISO/IEC 17025-accredited labs and GMP-aligned gas production facilities |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | Ca-11 |
| Instrument Type | Portable Ion Meter |
| Measurement Range | 4–9900 ppm (mg/L) Ca²⁺ |
| Detection Limit | ±1 ppm (0–99 ppm), ±10 ppm (100–990 ppm), ±100 ppm (1000–9900 ppm) |
| Response Time | ≤5 s |
| Accuracy | ±20% of reading |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤85% RH (non-condensing) |
| IP Rating | IP67 |
| Sensor Replaceable | Yes (approx. 1500 measurements per sensor) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | ORP-11 |
| Type | Portable ORP/Eh Meter |
| Measurement Range | −1000 to +1000 mV |
| Resolution | 1 mV |
| Accuracy | ±2 mV |
| Minimum Sample Volume | 0.3 mL (0.05 mL with sampling sheet) |
| Temperature Range | 0.0–50.0 °C |
| Temp. Resolution | 0.1 °C |
| IP Rating | IP67 |
| Display | Backlit monochrome digital LCD |
| Power | Two CR2032 batteries (~400 h operation without backlight) |
| Dimensions | 164 × 29 × 20 mm |
| Weight | ~55 g (incl. sensor & batteries) |
| Compliance | CE-marked, RoHS-compliant, designed for GLP-supporting workflows |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | OCMA-550 |
| Instrument Type | Portable |
| Measurement Principle | Non-Dispersive Infrared (NDIR) Absorption with S-316 Solvent Extraction |
| Measurement Range | 0–200 mg/L (water), 0–1000 mg/kg (soil), 0–1 Abs |
| Detection Limit | 0.1 ppm |
| Repeatability | ±0.4 mg/L (0–9.9 mg/L), ±2.0 mg/L (10.0–99.9 mg/L), ±4 mg/L (100–200 mg/L), ±1% F.S. (0–1 Abs) |
| Optical Path | Quartz Cuvette (200 mm path length) |
| Detector | Thermoelectric Sensor |
| Display | Backlit LCD with Timestamp |
| Interface | RS-232C, Parallel Printer Port |
| Power Supply | 230 V AC, 50 Hz |
| Dimensions | 250 × 200 × 285 mm (W × H × D) |
| Standard Accessories | Covered quartz cuvette, power cord, heavy oil standard (B-grade), 2 A fuse, 10 mL and 25 µL syringes |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | PG-300 Series |
| Product Type | Portable |
| Response Time | ≤45 s (SO₂: ≤180 s) |
| Repeatability | SO₂, NOₓ, CO, CO₂, O₂, CH₄ |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | TCA-51d / TCA-51p |
| Explosion Protection | Ex d IIB+H2 T4 / Ex px d IIC T4X |
| Detection Principle | Thermal Conductivity |
| Measurands | H₂, O₂ |
| Range | 0–10 to 0–100 vol% (H₂), 0–5 to 0–25 vol% (O₂) |
| Repeatability | ±0.5% F.S. (standard range) |
| Linearity | ±1.0% F.S. |
| Zero Drift | ±1.0% F.S./week (standard range) |
| Span Drift | ±2.0% F.S./week (standard range) |
| Response Time (T90) | ≤20 s |
| Sample Flow Rate | 300–1500 mL/min |
| Operating Pressure | ≥1.98 kPa (TCA-51d), ≥14.7 kPa (TCA-51p) |
| Wetted Materials | SUS304, SUS316, FKM, Pt, Au, SiO₂, Borosilicate Glass |
| Compliance | IEC 60079-0, IEC 60079-1 (Ex d), IEC 60079-2 (Ex p), ATEX Directive 2014/34/EU, UKCA |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | VA-5000 |
| Detection Range | CO, CO₂, NOₓ, SO₂, CH₄, C₂H₄, N₂O, O₂ |
| Repeatability | ±1.0% F.S. |
| Brand | HPC |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | OEM/ODM Producer |
| Product Origin | Domestic (China) |
| Model | HPC-K9-1000-NX |
| Applicable Gases | N₂, Ar, He, Kr, Ne, CH₄ |
| Removed Impurities | H₂O, O₂, CO₂, CO, H₂, Organic Compounds |
| Purification Depth | < 1 ppb |
| Flow Rate Range | 200–20,000 Nm³/h |
| Operating Temperature | Ambient (15–35 °C) |
| Construction Material | Electropolished 316L Stainless Steel |
| Inlet/Outlet Filtration | 3 µm (0.003 mm) 316L Sintered Metal Filter |
| Adsorption Mechanism | Dual-mode (Chemical + Physical Adsorption) |
| Brand | HPC |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HPC-Q9-10-WY |
| Applicable Gases | C₂H₇N, C₂H₈N₂, CH₃SiH₃, GeH₄, SiH₄, SF₆, CSiH₆ |
| Impurities Removed | H₂O, O₂, CO₂, NMHCs |
| Purification Depth | <1 ppbV |
| Flow Rate Range | 2–2000 slpm |
| Operating Temperature | Ambient |
| Brand | HPC |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | OEM Producer |
| Country of Origin | China |
| Model | HPC-Q9-1000-X |
| Applicable Gases | N₂, Ar, He, Kr, Ne, CH₄ |
| Impurities Removed | H₂O, O₂, CO₂, CO, H₂, Organic Compounds |
| Purification Depth | < 1 ppb |
| Flow Rate Range | 2–2000 slpm |
| Operating Temperature | Ambient |
| Brand | HPC |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HPC-Q9-120-X-V |
| Applicable Gases | N₂, Ar, He, Kr, Ne, CH₄ |
| Removed Impurities | H₂O, O₂, CO₂, CO, H₂, organic compounds |
| Purification Depth | < 1 ppb |
| Flow Rate Range | 2–2000 slpm |
| Operating Temperature | Ambient (15–35 °C) |
| Construction Material | 316L EP-grade stainless steel adsorption tube |
| Particulate Filtration | 0.003 µm 316L stainless steel sintered filter |