Environmental Monitoring Instruments
Filter
Showing 1501–1530 of 7659 results
| Brand | SYSTEA |
|---|---|
| Origin | Zhejiang, China |
| Model | EasyTox Pro |
| Measurement Principle | Bioluminescent Bacterial Assay (Aliivibrio fischeri) |
| Quantification Output | EC₅₀ (Half-Maximal Effective Concentration) |
| Analysis Platform | Automated Discrete Analyzer with Robotic Arm |
| Sample Throughput | Dual-channel simultaneous analysis |
| Reaction Vessel Capacity | 80-position rotating cuvette carousel |
| Signal Acquisition Interval | 60 s |
| Assay Duration | 2.5–30 min per sample |
| Bacterial Rehydration | Fully automated lyophilized culture reactivation |
| Operational Autonomy | Up to 90 days unattended (with refrigerated reagent/culture storage) |
| Regulatory Compliance | ISO 11348-3:2007 and GB/T 15441–1995 methods programmable |
| Data Integrity | Audit-trail-enabled software compliant with GLP/GMP documentation requirements |
| Refrigerated Storage Compartment | Dedicated 4 °C zone for lyophilized bacteria, controls, and reagents |
| Cross-Contamination Control | Integrated cleaning station with sequential rinse/flush protocols |
| QC Features | Real-time bioluminescence viability monitoring, dual parallel blank/sample measurement, automatic result validation logic |
| Brand | Campbell |
|---|---|
| Origin | USA |
| Model | EC150 |
| Measurement Principle | Open-path infrared absorption (CO₂/H₂O) + ultrasonic anemometry (3D wind, sonic temperature) |
| Output Frequency | Up to 60 Hz |
| Bandwidth | 20 Hz |
| Power Consumption | Low-power design suitable for solar-powered operation |
| Environmental Rating | Outdoor-rated, rain-resistant housing with hydrophobic mesh and angled optical windows |
| Calibration | Factory-calibrated for CO₂, H₂O, air temperature, barometric pressure, and sonic temperature across wide operational ranges |
| Compatibility | Native integration with Campbell Scientific dataloggers (CR6, CR1000X, etc.) for configuration, zero/span adjustment, diagnostics, and real-time data streaming |
| Diagnostic Capabilities | Comprehensive internal diagnostics including signal strength, window contamination index, path alignment status, and transducer health monitoring |
| Compliance | Designed to meet field requirements for FLUXNET, AmeriFlux, ICOS, and other long-term eddy covariance networks adhering to AmeriFlux/ICOS Best Practices and ISO 17025 traceable calibration protocols |
| Brand | ECH |
|---|---|
| Origin | Germany |
| Type | Laboratory Analyzer |
| Model | Sulfimax GX |
| Measurement Range | 0.01–10,000 ppm H₂S |
| Detection Limit | 0.01 ppm |
| Resolution | 0.1 µg absolute |
| Analysis Time | 2–10 min (typical: 5 min) |
| Sample Volume | 0.01–20 mL |
| Gas Flow Rate | up to 50 L/h |
| Power Supply | 230 V/50 Hz or 115 V/60 Hz |
| Power Consumption | 150 W |
| Dimensions (W×D×H) | 480 × 390 × 290 mm |
| Weight | 11 kg |
| Data Interface | RS-232 / USB (with converter) |
| Software Control | PC-based (PC not included) |
| Brand | TriOS |
|---|---|
| Origin | Germany |
| Model | eCHEM Free Chlorine |
| Instrument Type | Portable |
| Measurement Principle | Electrochemical Amperometric (3-Electrode, Membrane-Covered, Potentiostatic) |
| Measurement Parameter | Free Chlorine |
| Range | 0–2 mg/L and 0–20 mg/L |
| Accuracy | ±0.4 mg/L (≤2 mg/L range) |
| Temperature Compensation | Integrated Pt100 |
| Response Time (T90%) | ~2 min |
| Drift | ~1%/month |
| Membrane | Hydrophilic Microporous |
| Housing Material | PVC-U + Stainless Steel 1.4571 |
| Dimensions (L×Φ) | 205 mm × 25 mm |
| Weight | 0.1 kg |
| Interface | RS-485, Modbus RTU |
| Power Supply | 9–30 VDC (±10%) |
| Connector | 8-pin M12 |
| Power Consumption | 0.6 W |
| IP Rating | IP68 |
| Operating Temperature | 0–45 °C (liquid, ice-free) |
| Flow Rate Dependency | 15–30 L/h (in FLC-3 flow cell) |
| pH Range | 4–9 (low pH dependency: ~−10% signal change per pH unit) |
| Conductivity Range | 10–50 mS/cm |
| Cross-Sensitivity | Combined chlorine causes positive interference |
| Calibration Method | DPD-1 reference standard |
| Pressure Rating | 1 bar (static, no shock/vibration |
| Maintenance Interval | Weekly |
| Maintenance Time | ≤0.5 h/month |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 81180 |
| Price | Upon Request |
| Display | LCD |
| Operating Frequency | 200 kHz (Beam Width: 24°) |
| Depth Measurement Range | 0.6–80 m |
| Waterproof Rating | IP68 (50 m submersion rated) |
| Power Supply | 9 V alkaline battery (IEC 6F22 / ANSI 006P) |
| Origin | Switzerland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ECO nCLD63 |
| Price Range | USD 14,000 – 42,000 |
| Origin | Switzerland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CLD 60 Series |
| Pricing | Available Upon Request |
| Origin | Switzerland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CLD 80/800 Series |
| Price Range | USD 13,500 – 40,500 |
| Brand | AGC |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | ECO Physics nCLD 822 |
| Pricing | Upon Request |
| Brand | AGC |
|---|---|
| Origin | Switzerland |
| Model | ECO Physics nCLD 844 |
| Measurement Principle | Gas-Phase Chemiluminescence Detection |
| Detection Targets | NO, NO₂, NOₓ, NH₃ (via catalytic conversion) |
| Measurement Range | 0.5–500 ppm (4 programmable ranges) |
| Response Time (T90) | < 1 s |
| Minimum Detectable Concentration | 0.025 ppm |
| Sample Flow Rate | 1.2 L/min |
| Reaction Chamber Temperature | Up to 190 °C (heated sample line) |
| Ozone Generator | High-voltage, high-output |
| O₃ Decomposition | Integrated thermal catalytic decomposer (no consumables) |
| Compliance | Designed for EN 14181, ISO 11665, EPA Method 7E, ASTM D5158, and GLP/GMP-aligned data integrity workflows |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | A-21ZX |
| Instrument Type | Fixed-Mount |
| Measurement Range | 0–10 ppm |
| Detection Limit | 0.01 ppm (resolution) |
| Response Time | <60 seconds (T90) |
| Zero Drift | <±0.02 ppm/week |
| Resolution | 0.01 ppm |
| Dimensions | 110 × 220 × 64 mm (L×W×H) |
| Weight | 570 g |
| Power Supply | 12–24 VDC, 500 mA |
| Operating Temperature | 0–40 °C |
| Relative Humidity | 0–95% RH (non-condensing) |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Regional Origin | Domestic (China) |
| Model | Eco-Watch |
| Pricing | Available Upon Request |
| Brand | EcoChem |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DC-2200CE |
| Instrument Type | Aerosol Detector |
| Power Supply | 15 V Rechargeable Li-ion Battery |
| Display | 2-line × 16-character LED |
| Weight | 1.5 kg |
| Dimensions | 68 mm × 175 mm × 124 mm |
| Operating Temperature | 5–40 °C |
| Storage Capacity | 8,000 data points (timestamp + surface area value) |
| Flow Rate | 1 LPM |
| Measurement Range | 0–1000 µm²/cm³ |
| Detection Limit | 0–10 µm²/cm³ |
| Sensitivity | 0–10 µm²/cm³ |
| Response Time | <10 s (adjustable) |
| Data Output | RS232 |
| Software Compatibility | PC-based charting utility with Excel export |
| Brand | EcoChem |
|---|---|
| Origin | USA |
| Model | PAS-2200CE |
| Instrument Type | Aerosol-Bound PAH Monitor |
| Detection Principle | UV Photoionization of Adsorbed PAHs |
| Measurement Range | 0–1000 ng/m³ |
| LOD | 10 ng/m³ (total adsorbed PAH) |
| Flow Rate | 1 L/min |
| Response Time | <10 s (adjustable) |
| Sensitivity | 10 ng/m³ |
| Operating Temperature | 5–40 °C |
| Data Storage | 8,000 points (timestamped) |
| Weight | 1.5 kg |
| Dimensions | 58 × 175 × 124 mm |
| Power | 15 V DC (rechargeable battery) or 220 V AC/50 Hz |
| Display | 2-line × 16-character LED |
| Output | RS232 serial interface |
| Data Logging | Embedded system (up to 2,500 records) |
| Brand | EcoChem |
|---|---|
| Origin | USA |
| Model | PAS2000 STD |
| Instrument Type | Aerosol Detector |
| Detection Principle | UV Photoionization of Particle-Bound Polycyclic Aromatic Hydrocarbons (PAHs) |
| Measurement Range | 0–100 µg/m³ (PAH), 0–100 µg/m³ (Elemental Carbon), 0–100 pA (Ion Current) |
| Detection Limit | 3 ng total adsorbed PAH |
| Sensitivity | 0.3–1 µg/m³ PAH per pA |
| Response Time | <10 s (adjustable) |
| Flow Rate | 2 LPM |
| Operating Temperature | 5–40 °C |
| Data Storage | 8,000 points (timestamped) |
| Display | 2×16-character LED |
| Output Interfaces | RS-232, 0–10 V, 0–20 mA, or 4–20 mA |
| Dimensions | 68 × 175 × 124 mm |
| Weight | 9 kg |
| Power Supply | 220 V AC / 50 Hz |
| Optional Heated Sampling Probe | 5–300 °C |
| Dilution Ratios | 0.05, 0.1, 0.2 (with mass flow controller and critical orifice) |
| Origin | Shaanxi, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | EcoDrone |
| Price | USD 42,000 (FOB) |
| Origin | Beijing |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | EcoDrone UAS-4 |
| Pricing | Upon Request |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | Ecodrone UAS-4 Pro |
| Pricing | Available Upon Request |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | EcoDrone UAS-4 Thermal Imaging Remote Sensing System |
| Pricing | Upon Request |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | EcoDrone UAS-4 |
| Price | Upon Request |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | UAS-8 |
| Pricing | Available Upon Request |
| Origin | Shaanxi, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | EcoDrone UAS-8 |
| Pricing | Upon Request |
| Origin | Beijing |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | EcoDrone-Aisa |
| Price | Upon Request |
| Origin | Beijing |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | Ecodrone® High-Precision |
| Price | Upon Request |
| Origin | Czech Republic |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Ecodrone® |
| Pricing | Upon Request |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | Ecodrone® UAS-8 UAV Platform |
| Quotation | Upon Request |
| Payload Capacity | ≥5000 g |
| Max Takeoff Weight | ≥15000 g |
| Empty Weight | ≤5000 g |
| Rotor Span (Symmetrical) | 1200 mm |
| Hover Time (No Payload) | ≥50 min |
| Operational Flight Time (with Multispectral Sensor) | 30 min |
| Cruise Speed | 10 m/s |
| GNSS Support | Dual-band GPS/BeiDou |
| Positioning Accuracy | 1 cm (Barometric + GNSS Altitude Hold) |
| RGB Camera | 4K @ 30 FPS, 16 MP, f/2.8, 120° HFOV (optional 82° low-distortion lens) |
| Remote Control | Dual-antenna, 2.400–2.483 GHz DSSS, 16/32 channels, FCC EIRP 100 dBm, max control range 2.7 km (7 km with extended-range mode) |
| FPV Transmission | Dual-path analog + digital 5.8 GHz, 1080p real-time streaming (visible + thermal), 5 km range, 1920×1080 display resolution |
| Data Telemetry | Real-time transmission of latitude/longitude, altitude, ambient temperature/humidity, solar radiation, ground surface temperature |
| Ground Station | Ruggedized laptop in portable case, multi-map support (Google/Bing/AMap), mission planning, telemetry logging, Follow-Me mode |
| Battery | 22000 mAh LiPo, dual-channel charger (12 A, 1400 W max) |
| Thermal Imager | GIS-320, 320×240 InSb FPA, spectral band 3.2–3.4 μm, NETD ≤15 mK, frame rate 30 Hz, auto/manual focus, 1–8× motorized zoom, temperature ranges selectable: −25°C to 150°C / −40°C to 550°C / 400°C to 1500°C |
| Visible Camera (co-mounted) | 1280×960, 14× digital zoom, auto-focus |
| Video Output | 720p via mini-HDMI |
| Storage | Internal 64 GB SD card |
| Radiometric Formats | Radiometric JPEG, non-radiometric JPEG, synchronized IR+RGB video (30 Hz) |
| Gas Detection Capability | Benzene, ethanol, toluene, xylene isomers, methane, propane, ethylene, propylene, methanol, MEK, MIBK, hexane, heptane, octane, pentane, 1-pentene, isoprene, butane, ethylbenzene, etc. |
| Power Input | 12–19 VDC |
| Dimensions (GIS-320) | 257×117×126 mm |
| Weight (GIS-320) | <1.7 kg |
| Origin | Shaanxi, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | Ecodrone® UAS-8 |
| Pricing | Available Upon Request |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Regional Origin | Domestic (PRC) |
| Model | Ecodrone® UAS-8 Pro |
| Pricing | Upon Request |
| Brand | SPECIM |
|---|---|
| Origin | Czech Republic |
| Model | Ecodrone® UAS-8 Pro |
| Sensor Configuration | Specim AFX10 (400–1000 nm) or AFX17 (900–1700 nm) + WIRIS Thermo-RGB (640×512 IR resolution, up to 1266×1010 in high-res mode, thermal sensitivity ≤0.03 °C) |
| Platform | UAS-8 Pro professional UAV platform (high-payload, extended endurance) |
| Optional Integration | YellowScan Mapper+ LiDAR (for EcoDrone-LiHT configuration) |
| Compliance | Designed for ASTM E2923, ISO 18434-1, and FAO/UNEP remote sensing protocol alignment |
| Software | Ecodrone Flight & Processing Suite v4.x with embedded FLAASH atmospheric correction, FLD-based SIF retrieval, and GLP-compliant metadata logging |
| Brand | UGT |
|---|---|
| Origin | Germany |
| Model | ECOLAB FLEX |
| Configuration | Modular Soil Unit + Atmospheric Unit + Central Control & Data Acquisition Unit |
| Compliance | Designed for GLP-compliant environmental research and ISO 14040/14044 life cycle assessment studies |
| Sensor Integration | Supports analog/digital (SDI-12, RS-485, 0–10 V, 4–20 mA) interfaces for third-party and OEM sensors |