Environmental Monitoring Instruments
Filter
Showing 2161–2190 of 2621 results
| Brand | Senbe |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | CCZ-20 |
| Pricing | Available Upon Request |
| Compliance | GB/T 3836.18–2017 (Intrinsically Safe Electrical Systems for Explosive Atmospheres), GB/T 20964–2007 (Dust Samplers), Q/HHD 0103–2016 (Enterprise Standard), BMRC Respirable Dust Separation Curve Conformance |
| Protection Rating | IP54 |
| Construction | High-strength ABS engineering plastic housing with anti-humidity, anti-dust, and anti-static treatment |
| Flow Stability | Low pulsation, high load capacity, stable volumetric flow |
| Operational Interface | PVC membrane switch panel |
| Certification | MA (Mine Safety Approval) and Explosion-Proof Verification Certificate |
| Brand | Senbe |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | DP8600 |
| Measurement Principle | Full-Spectrum Absorption Spectrophotometry |
| Wavelength Range | 190–1100 nm |
| Measurable Parameters | COD, Ammonia Nitrogen, Nitrate Nitrogen, Nitrite Nitrogen, Total Nitrogen, Total Phosphorus |
| Sample Holders | Cuvette (standard), 16 mm and 25 mm test tubes |
| Light Sources | Imported Deuterium Lamp (UV), Tungsten-Halogen Lamp (Vis) |
| Detector | Imported Photodiode Array |
| Display | 7-inch TFT color touchscreen (bilingual: English/Chinese) |
| Optical Functions | Photometric Mode, Quantitative Analysis, Standard Curve Construction, Kinetic Scanning, Full-Spectrum Scan |
| Data Storage | USB flash drive support |
| Custom Curve Capability | Yes |
| Optional Accessories | 5 cm and 10 cm sample holders |
| Brand | Senbe |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | EDXP3600 |
| Price | Upon Request |
| Excitation Source | 50 kV / 200 µA Ag-target micro-focus X-ray tube, end-window configuration, ≤4 W power match |
| Detector | 25 mm² fast Silicon Drift Detector (SDD), 0.3 mil Be window, energy resolution ≤125 eV (Mn Kα), Peltier-cooled |
| MCA | 4096-channel digital pulse processor |
| Elemental Range | Na (11) to U (92) |
| Analysis Modes | Alloy, RoHS, Soil, Water |
| Soil LODs (SiO₂ matrix) | Pb <5 mg/kg, As <3 mg/kg, Cr <15 mg/kg, Cu <10 mg/kg, Zn <2 mg/kg, Ni <5 mg/kg, Mn <10 mg/kg, Hg <1 mg/kg, Cd <3 mg/kg |
| Water LODs (aqueous matrix) | Pb <1 mg/L, As <0.5 mg/L, Cr <2 mg/L, Cu <1 mg/L, Zn <2 mg/L, Ni <1 mg/L, Mn <2 mg/L, Hg <1 mg/L, Cd <1 mg/L |
| Quantification Time | 3–60 s (user-adjustable) |
| Repeatability | RSD <4% (for major elements in homogeneous alloys) |
| Collimation & Filters | 6 interchangeable filters + multiple collimators → 18 automatic combinations |
| Display | 5.5″ high-brightness capacitive touchscreen LCD |
| Processor | Intel quad-core @ 1.33 GHz |
| Memory | 2 GB RAM, 32 GB internal storage (expandable via microSD) |
| Connectivity | Wi-Fi 802.11 b/g/n, Bluetooth 4.0, USB 2.0, GPS module |
| Safety | Beam-on detection sensor, auto X-ray cutoff during air measurement |
| Weight | 1.5 kg (with battery) |
| Operating Environment | –20 °C to +50 °C, RH <90% non-condensing |
| Power | Rechargeable Li-ion, 6700 mAh, >6 h typical operation |
| Data Output | Excel, BMP, PDF reports |
| Compliance | Meets IEC 62471 (LED/X-ray safety), ISO 12885 (XRF safety guidance), and supports GLP/GMP audit trail requirements via timestamped, user-logged data export |
| Brand | Senbe |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic |
| Model | FD216 |
| Sampling Method | Active Pump-Driven Sampling |
| Measurement Range (Air Radon) | 3–100,000 Bq/m³ |
| Minimum Detectable Activity | 3 Bq/m³ |
| Response Time (Air) | 30 min |
| Detector | ZnS(Ag) Scintillation Screen Coupled with Photomultiplier Tube (PMT) |
| Sensitivity | ≥0.68 cpm/(Bq·m⁻³) |
| Background Count Rate | ≤0.3 cpm |
| Repeatability Error | ≤5% (at 2000 Bq/m³, 65% RH, 25°C) |
| Stability | ≤10% drift over 8 h |
| Power Supply | Rechargeable Li-ion Battery (30 h continuous operation) or AC Adapter |
| Operating Temperature | −10 to +40 °C |
| Relative Humidity | ≤90% at +40 °C |
| Data Storage Capacity | 2000 records |
| Display | LCD |
| Dimensions | 330 × 210 × 170 mm |
| Weight | 5 kg (main unit) |
| Brand | Senbe |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Manufacture | China |
| Model | MP5300 |
| Pricing | Available Upon Request |
| Brand | Senbe |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | PF-3 |
| Instrument Type | Multi-Parameter Soil Analyzer |
| Optical System | LED-based photometer with interference filters |
| Wavelengths | 365 nm / 450 nm / 660 nm |
| Wavelength Accuracy | ±2 nm |
| Bandwidth at Half-Maximum | 10–12 nm |
| Light Source | High-stability LEDs |
| Detector | Silicon photodiode |
| Sample Format | 16 mm round cuvettes (VISOCOLOR® ECO and NANOCOLOR® pre-filled tubes) |
| Measurement Modes | VISOCOLOR® ECO and NANOCOLOR® test protocols |
| Data Storage | 50 measurement records |
| Display | Graphical LCD, 64 × 128 pixels |
| Operating Temperature | 10–40 °C |
| Relative Humidity | ≤80% RH (non-condensing) |
| Power Supply | 3 × AA batteries (alkaline or rechargeable) / USB 5 V power input / optional internal rechargeable battery |
| Enclosure Rating | IP68 |
| Dimensions | 170 × 95 × 68 mm |
| Weight | 0.5 kg |
| Certifications | CE compliant |
| Warranty | 1 year |
| Brand | Senbe |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | SAI008 |
| Pricing | Upon Request |
| Measurement Principle | Hyperspectral Reflectance Analysis (400–1000 nm, 1 nm spectral resolution) |
| Measurable Parameters | COD, Ammonia-Nitrogen (NH₃-N), Total Phosphorus (TP), Total Nitrogen (TN), Chlorophyll-a, Turbidity, Secchi Depth, CODMn, Suspended Solids (SS), CDOM (optional), Attenuation Coefficient (optional) |
| Sampling Interval | Configurable down to 1 second |
| Brand | SENBE |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic |
| Model | SEN-ABR50 |
| Instrument Type | Portable |
| Measurement Target | Solid Surfaces |
| Detector Technology | Plastic Scintillation Detector (Alpha/Beta/Gamma Discriminative) |
| Energy Response | Alpha (≥3 MeV), Beta (≥150 keV), Gamma (≥50 keV) |
| Display | Backlit LCD |
| Alarm | Adjustable Threshold with Real-Time Background Compensation |
| Power Supply | Rechargeable Li-ion Battery (≥12 h continuous operation) |
| Compliance | Meets IEC 60846-1:2014 and GB/T 10257–2022 for portable radiation contamination monitors |
| Brand | Senbe |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | SEN806C |
| Instrument Category | Manual Water Sampler |
| Instrument Type | Portable Water Sampler |
| Brand | Senbe |
|---|---|
| Model | SEN905 |
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Localization | Domestic (China) |
| Network Support | China Mobile / China Telecom / China Unicom 2G/3G/4G LTE |
| GNSS Modes | DGNSS (<0.5 m), RTK (5 cm + 1 ppm) |
| Differential Formats | RTCM 3.0, RTCM 3.2 (vs. legacy RTD) |
| Display | 8-inch electromagnetic resonance touchscreen (U-Pen compatible) |
| Interface | USB Type-C (10,000-cycle durability) |
| Battery | Removable 8400 mAh Li-polymer |
| Operating System | Android 6.0.1 |
| Charging | Qualcomm Quick Charge 2.0 |
| Compliance | CE (EMC/LVD), RoHS, IP65-rated enclosure |
| Software Architecture | Field-deployable logging firmware with remote command ingestion and bidirectional telemetry |
| Brand | Senbe |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | UCA1000 |
| Instrument Type | Algal Monitoring and Control System |
| Compliance | HJ 915-2017, GB 3838-2002, GB/T 12519-2010 |
| Brand | Senbe |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | YQ3000-E |
| Instrument Type | Flue Gas Dioxin Sampler |
| Sample Medium | Flue Gas |
| Flow Accuracy | ±5% |
| Sampling Flow Rate | 1.5 L/min |
| Flue Gas Velocity Range | Up to 4 m/s |
| Moisture Content Tolerance | Up to 60% (v/v) |
| Brand | Shanda |
|---|---|
| Model | SD-QY04 |
| Type | Manual Core Sampler |
| Origin | Shandong, China |
| Sampling Depth | Up to 2 m |
| Standard Configuration | Four interchangeable coring bits (clay, loam, sand, peat), two 100 cm extension rods, one 50 cm extension rod, T-handle, soil scraper, dual wrenches, 3 m steel tape measure, protective gloves, aluminum carrying case |
| Brand | Shanda |
|---|---|
| Model | SD-SW |
| Instrument Type | Multifunctional Soil Analyzer |
| Display | Large Backlit Chinese LCD |
| Power Supply | Rechargeable Lithium Battery or AC Adapter |
| Dimensions | 204 × 100 × 36 mm |
| Measurement Principle | Frequency Domain Reflectometry (FDR) |
| Soil Volumetric Water Content Range | 0–100% (m³/m³) |
| Accuracy | ±2% (0–50%), ±3% (50–100%) |
| Resolution | 0.1% (moisture), 0.1°C (temperature) |
| Temp. Range | −40 to +120°C |
| Temp. Accuracy | ±0.2°C |
| Response Time | <1 s |
| Stabilization Time | ~10 s |
| Sensing Volume | 90% influence within a 3 cm diameter × 6 cm length cylinder centered on probe |
| Communication | USB 2.0 |
| Data Logging | Manual/Automatic (configurable interval) |
| Optional Connectivity | 4G module for cloud upload to web-based agricultural platform |
| Software | Free PC-based data management suite (Excel export, curve plotting, GLP-compliant audit trail) |
| Brand | SHDROID Scientific |
|---|---|
| Origin | Beijing, China |
| Model | CDOM-A01 |
| Detection Principle | Time-Resolved Fluorescence (TRF) with UV-LED Excitation & PMT-Based Single-Photon Counting |
| Measurement Output | CDOM Concentration (QSU or Raman-normalized units), Fluorescence Lifetime Distribution (ns range), Component-Specific Fluorescence Signatures |
| Environmental Rating | IP68 Submersible Housing (PTFE-Coated Aluminum Alloy) |
| Communication Interface | 100BASE-TX Ethernet (RJ45), Modbus TCP Support |
| Power Supply | 24 VDC ±10%, <8 W |
| Operating Temperature | −10 °C to +50 °C |
| Response Time | <5 s (real-time in-situ measurement) |
| Calibration Options | On-site NIST-traceable quinine sulfate & humic acid reference kits |
| Brand | Shenchanghong |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | CY-2 |
| Instrument Type | Laboratory BOD Analyzer |
| Measurement Principle | Manometric (Pressure-Difference) Method |
| Measurement Range | 0–1000 mg/L |
| Detection Limit | 1 mg/L |
| Accuracy | ≤5% |
| Single-Sample Incubation Duration | 5 days |
| Repeatability | ±3% |
| Display | Direct-Reading Digital Display |
| Batch Capacity | 8 samples per run |
| Incubation Temperature Control | 20 ± 1 °C |
| Dimensions (W × D × H) | 400 × 270 × 350 mm |
| Net Weight | 6 kg |
| Power Consumption | <15 W |
| Compliance | GB 7488–1987 |
| Brand | Shenchanghong |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | PMULP-800 |
| Instrument Type | Portable |
| Temperature Range | 0–100 °C |
| pH Range | 0.00–14.00 |
| Dissolved Oxygen (DO) Range | 0–20.0 mg/L |
| Conductivity Range | 0.00 µS/cm – 199.9 mS/cm |
| Turbidity Range | 0–400 NTU |
| Optical Wavelengths | 420, 440, 470, 520, 540, 560, 610, 630, 660, 680, 700 nm (user-selectable within range) |
| Absorbance Accuracy | ≤±5% FS |
| Repeatability | ≤3% RSD |
| Absorbance Drift | <0.002 A in 20 min |
| Dimensions (Main Unit) | 92 × 185 × 50 mm |
| Weight (Main Unit) | ~0.4 kg |
| Total Kit Weight (incl. case & accessories) | ~1.5 kg |
| Power Supply | Rechargeable Li-ion battery, 7.4 V / 1500 mAh |
| Operating Environment | 5–40 °C, ≤85% RH, low-vibration, non-direct-sunlight |
| Brand | Sherwood |
|---|---|
| Origin | United Kingdom |
| Model | M926, M926S |
| Instrument Type | Benchtop Chloride Analyzer |
| Detection Principle | Coulometric Titration (Silver Nitrate Electrolytic Generation) |
| Sample Volume | M926: 500 µL |
| M926S | 20 µL |
| Measurement Range | M926: 10–999 mg/L Cl⁻ (equivalent to 2–165 mg% NaCl) |
| M926S | 10–299 mmol/L Cl⁻ |
| Detection Limit | 10 mg/L Cl⁻ (M926) |
| Response Time | ≤36 s (typical endpoint detection) |
| Accuracy | M926: ±3 mg/L or <1% RSD at 0.1% Cl⁻ |
| M926S | ±2% at 100 mmol/L Cl⁻ |
| Linearity | ≤1% deviation across full range |
| Repeatability (CV, n=20) | <1.5% at mid-range concentration |
| Temperature Control | Integrated ambient-temperature-stabilized cell compartment |
| Compliance | Designed for GLP/GMP environments |
| Key | Origin: Imported |
|---|---|
| Manufacturer Type | Distributor |
| Model | LD-3C |
| Measurement Principle | Light Scattering (Laser Nephelometry) |
| Safety Rating | Non-explosion-proof |
| Range (Low) | 0.01–100 mg/m³ |
| Range (High) | 0.001–10 mg/m³ |
| Sensitivity (L) | 1 CPM = 0.01 mg/m³ |
| Sensitivity (H) | 1 CPM = 0.001 mg/m³ |
| Sampling Time Options | 0.1, 1, 2, 5, 10 min + manual mode |
| Accuracy | ±10% |
| Dimensions | 192 × 69 × 140 mm |
| Weight | 1.4 kg |
| Compliance | WS/T 206–2001, LD 98–1996, TB/T 2323–92 |
| Brand | Shimadzu |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | COD-4200 |
| Instrument Type | Online Analyzer |
| Measurement Principle | High-Temperature Potassium Dichromate Digestion with Photometric Detection |
| Standard Range | 30–4000 mg/L COD |
| Accuracy | ±10% at ≥100 mg/L |
| Repeatability | ≤±5% |
| Zero Drift | ±5 mg/L |
| Span Drift | ≤±5% |
| Resolution | <1 mg/L |
| Minimum Measurement Cycle | 20 minutes |
| Calibration Modes | Manual and Automatic |
| Communication Interfaces | RS-232, 4–20 mA (bidirectional) |
| Power Supply | 220 VAC ±10%, 50 Hz ±5% |
| Power Consumption | ~100 VA |
| Dimensions | 500 mm × 420 mm × 1550 mm |
| Weight | ~90 kg |
| Brand | Shimadzu |
|---|---|
| Model | DLTR-2030 |
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (PRC) |
| Pricing | Available Upon Request |
| Brand | Shimadzu |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Line | HMA-4200 Series |
| Measurement Principles | Colorimetric Spectrophotometry per ISO 11969 / GB/T 7467–1987 (for Cr(VI)), ISO 11045 / GB/T 7475–1987 (for Total Cr, Cu, Ni) |
| Detection Range | 0–2 mg/L (Cr(VI), Total Cr), 0–3.5 mg/L (Total Cu), 0–10 mg/L (Total Ni) |
| Accuracy | ≤±5% FS |
| Repeatability | ≤±5% RSD |
| Linearity Error | ≤±5% FS |
| Span Drift | ≤±5% over 24 h |
| Zero Drift | ≤±3% (Cr(VI), Total Ni), ≤±5% (Total Cu) |
| Minimum Measurement Cycle | 20 min (Cr(VI)), 50 min (Total Cr, Cu, Ni) |
| Calibration Mode | Manual or Automatic (with standard solution dispensing module) |
| Output Interface | RS-232 serial port and isolated 4–20 mA analog output |
| MTBF | ≥1440 h |
| Power Supply | 220 VAC ±10%, 50 Hz ±5% |
| Dimensions (H×W×D) | 1550 × 500 × 420 mm |
| Enclosure Rating | IP54 (indoor installation) |
| Compliance | Designed to support ISO/IEC 17025-compliant QA/QC workflows |
| Brand | Shimadzu |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (PRC) |
| Model | Shimadzu Mobile Laboratory |
| Pricing | Upon Request |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | NOA-7000 / CGT-7000 / SOA-7000 |
| Pricing | Available Upon Request |
| Measurement Accuracy | ±0.5% of Full Scale |
| Weight | ~14.5–15 kg |
| Brand | Shimadzu |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Type | Online Fixed-Mount Analyzer |
| Model | NSA-3080A |
| Measurement Principle | Non-Dispersive Infrared (NDIR) + Electrochemical (EC) + Paramagnetic (O₂) |
| Gas Components | SO₂, NOₓ, CO, CO₂, O₂ (up to 5 simultaneously) |
| Detection Ranges | NOₓ (100–2500 ppm), SO₂ (100–5000 ppm), CO (100 ppm–1 vol%), CO₂ (5–20 vol%), O₂ (0–25 vol%) |
| Calibration | Automated hourly or weekly zero/span correction |
| Operating Ambient Temperature | −5 to 40 °C |
| Power Supply | AC 220 V ±10%, 50 Hz, ~700 VA |
| Data Storage | Removable SD card interface |
| Compliance | Designed for continuous emissions monitoring (CEMS) per Chinese HJ 75/76 standards |
| Brand | Shimadzu |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | CEMS |
| Instrument Type | Continuous Emission Monitoring System (CEMS) |
| Core Analyzers | NSA-3080A Online Gas Analyzer, RBV-DUST/II In-Situ Dust Monitor, VPT511BF-A Volumetric Flow Meter |
| Data Acquisition | Integrated DAQ & Reporting Platform |
| Regulatory Alignment | Designed for compliance with HJ 75–2017, HJ 76–2017, EPA Method 1–4, 6C, 7E, 10, and ISO 12141, ISO 15712 |
| Brand | Shimadzu |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | TNP-4200 |
| Measurement Parameters | Total Nitrogen (TN), Total Phosphorus (TP) |
| Instrument Type | Online Analyzer |
| Measurement Principle | Alkaline Potassium Persulfate UV Oxidation – UV Absorbance (TN) |
| Detection Range | TN: 0–2 / 5 / 10 / 20 / 50 / 100 / 200 mg N/L |
| TP | 0–0.5 / 1 / 2 / 5 / 10 / 20 / 50 / 100 mg P/L |
| Cycle Time | 60 min (simultaneous TN & TP) |
| Power Consumption | ≤300 VA (AC 100–240 V, 50/60 Hz) |
| Operating Environment | Indoor use only |
| Sample Pretreatment | High-speed rotary homogenizer with auto backwash filter |
| Auto-Cleaning | Scheduled distilled water flush of fluidic pathways |
| Auto-Calibration | Dual-point (zero & span) using standard solutions |
| Brand | Shimadzu |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | TOC-4200 |
| Instrument Type | Online TOC Analyzer |
| Oxidation Method | High-Temperature Catalytic Combustion at 680 °C |
| Detection Principle | NDIR (Non-Dispersive Infrared) CO₂ Detection |
| Measurement Range | 0–1 ppm to 0–20,000 ppm (auto-ranging) |
| Cycle Time | Minimum 4 minutes per analysis |
| Carrier Gas | High-Purity Nitrogen (≥99.99%, 250–300 kPa) |
| Power Supply | 90–260 V AC, 50/60 Hz, 6 A |
| Power Consumption | 200 W (at operating temperature) |
| Operating Environment | 0–40 °C, ≤90% RH, Indoor Installation Only |
| Calibration | Auto-zero & span calibration |
| Sample Handling | Integrated high-speed rotary homogenizer |
| Internal Cleaning | Scheduled distilled-water flush of fluidic pathways |
| Interface | Full-color capacitive touchscreen |
| Communication | MODBUS RTU over RS-232/RS-485, 4–20 mA analog output, digital I/O |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | TOC-L |
| Instrument Type | Laboratory TOC Analyzer |
| Oxidation Method | High-Temperature Catalytic Combustion Oxidation (680 °C) |
| Measurement Range | 4 μg/L to 30,000 mg/L |
| Detection Principle | CO₂ quantification via Non-Dispersive Infrared (NDIR) detection after catalytic combustion |
| Power Savings | Up to 36% vs. prior generation (8 h/day, 5 days/week) |
| Footprint Reduction | Width reduced from ~440 mm to 340 mm |
| Brand | Shimadzu |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic |
| Model | TP-4110 |
| Measurement Parameter | Total Phosphorus (TP) |
| Instrument Type | Online Analyzer |
| Measurement Principle | Potassium Persulfate UV Oxidation–Molybdenum Blue Spectrophotometry |
| Detection Range | 0–0.5 / 1 / 2 / 5 / 10 / 20 / 50 / 100 mg P/L |
| Measurement Cycle | 60 min |
| Sample Pretreatment | High-speed rotary homogenizer + automatic backwash filtration using tap water |
| Automatic Cleaning | Distilled water flush at user-defined intervals |
| Power Supply | 220 V ±10 V, 50/60 Hz, ≤300 VA |
| Operating Temperature | 1–40 °C |
| Relative Humidity | ≤90 % RH (non-condensing) |
| Installation | Indoor only |
| Compliance | Designed for continuous compliance monitoring per China’s HJ 353–2019, HJ 354–2019, and HJ 355–2019 standards for online water quality analyzers |