Environmental Monitoring Instruments
Filter
Showing 2131–2160 of 9029 results
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | QCD |
| Pricing | Available Upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Model | RC-1000/2000 |
| Pricing | Available Upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM/ODM Producer |
| Country of Origin | China |
| Model | SG-100 |
| Pricing | Available Upon Request |
| Brand | FPI (Focus Photonics Inc.) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | TOFMS-100 |
| Detection Principle | Single-Photon Ionization Time-of-Flight Mass Spectrometry (SPI-TOFMS) |
| Instrument Type | Continuous Online Analyzer |
| Configuration | Integrated VOC Monitoring System with GIS-enabled Mobile Deployment Capability |
| Detection Range | 0.1 ppb – 1000 ppm (v/v) |
| Mass Resolution | >800 (FWHM at m/z 92) |
| Accuracy | < ±1% Full Scale (0–500 ppb) |
| Response Time | ≤1 s (T90) |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer | FPI (Hangzhou) Co., Ltd. |
| Model | TOX-2000 |
| Dimensions | 0.60 m × 0.55 m × 1.00 m (L×W×H) |
| Weight | 60 kg |
| Power Supply | 220 V ±10%, 50 Hz ±1% |
| Operating Temperature | 10–30 °C ambient |
| Water Temperature | 0–40 °C (non-freezing) |
| Response Time | <5 min |
| Detectable Toxic Substances | >5,000 compounds including heavy metals, pesticides, herbicides, biocides, and industrial chemicals |
| Sensitivity (EC₅₀) | HgCl₂ < 0.2 mg/L |
| Repeatability | RSD < 5% |
| Bacterial Cartridge Lifespan | 30 days |
| Data Logging Interval | Configurable down to 1 s |
| Output Signals | 4–20 mA analog |
| Toxicity Classification Levels | 5-tier scale (Low, Moderate, High, Severe, Extreme) |
| Compliance | ISO 11348-3 (Vibrio fischeri luminescence inhibition test) |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | TPN-2000 |
| Instrument Type | Online Analyzer |
| Measurement Principle | High-Temperature/High-Pressure Alkaline Potassium Persulfate Digestion + UV Spectrophotometry |
| Measurement Range | 0–0.5 / 0–2 / 0–5 mg/L (selectable) |
| Accuracy | ±10% of reading |
| Detection Limit | 0.005 mg/L |
| Compliance | HJ 636–2012 |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | V-1000 |
| Instrument Category | Meteorological Visibility Sensor |
| Measurement Principle | Infrared Forward Scatter at 42° |
| Range | 10–30,000 m |
| Operating Environment | All-weather, including fog, rain, snow, and freezing conditions |
| Power Consumption | Low-power design for remote deployment |
| Calibration Option | Compatible with FPI Model 28678 Field Calibration Kit |
| Enclosure | Integrated Heated Housing to Prevent Condensation and Ice Accumulation |
| Airflow Management | Aerodynamically Optimized Sensor Geometry to Minimize Flow Disturbance |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | VOC-3000 |
| Pricing | Upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | WAGA |
| Configuration | Online Continuous Monitoring System |
| Measurement Principle | Wet-Chemical Extraction Coupled with Ion Chromatography (IC) |
| Instrument Type | Online Multicomponent Aerosol Ion Analyzer |
| Compliance | Designed for ambient air quality monitoring per Chinese HJ 653–2013 and compatible with ISO 12884, EN 14902, and US EPA OTM-33A method frameworks |
| Brand | FPI (Fortune Photonics Instrumentation) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM/ODM) |
| Model | WCS-3000 |
| Power Supply | 220 V AC |
| Operating Temperature | 5–45 °C |
| Relative Humidity | 0–95 % RH (non-condensing) |
| Enclosure Rating | IP65 |
| Impact Resistance | IK08 |
| Display | 7" TFT LCD touchscreen (800 × 480 resolution, LED backlight, 154 × 86 mm visible area) |
| Communication | RS485, Modbus RTU protocol |
| Data Storage | ≥1 year local history (timestamped, non-volatile) |
| Dimensions | 235 × 185 × 117 mm (W × H × D) |
| Housing Material | Flame-retardant polycarbonate (UL94-V0 certified) |
| Analog Outputs | None |
| Relay Outputs | None |
| Digital I/O | RS485 only |
| Expandable Probes | Optional integration of phycocyanin (blue-green algae), chlorophyll-a, and UV-absorbance-based COD estimation sensors |
| Brand | FPI (Focus Photonics Inc.) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | WPR-Series |
| Laser Source | Not applicable (UHF/VHF passive radar principle) |
| Detector | Coherent pulsed Doppler receiver with 16-bit A/D sampling |
| Operating Frequency Band | UHF (915 MHz) or VHF (50 MHz typical, configurable) |
| Maximum Detection Altitude | Up to 12 km (dependent on frequency band and atmospheric conditions) |
| Pulse Repetition Frequency (PRF) | Configurable, typically 100–2,000 Hz |
| Measurement Parameters | Horizontal wind vector (u/v), vertical velocity (w), virtual temperature gradient, refractivity structure parameter (Cn²) |
| Compliance | Designed per MIL-STD-810G environmental ruggedization |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | WIZ Probe |
| Instrument Type | Online Water Quality Analyzer |
| Deployment Method | Buoy-Mounted In-Situ Monitoring System |
| Measurement Principle | Wet-Chemical Spectrophotometry (UV-Vis) + Fluorescence (for NH₃-N) |
| Configurable Parameters | NH₃-N, PO₄-P, NO₃⁻+NO₂⁻-N, NO₂⁻-N (standard) |
| Power Supply | Integrated Solar/Battery System via WIZbuoy Platform |
| Data Logging & Remote Access | WIZlog Data Logger with Cellular/GPRS or LoRaWAN Connectivity |
| Compliance Framework | Designed for ISO 5667 series (water sampling), ASTM D3370 (in-situ sampling), and compatible with EPA Method 353.2 (nitrate/nitrite), EPA 365.1 (phosphate), EPA 350.1 (ammonia), and EU WFD (Water Framework Directive) monitoring requirements |
| Key | Brand: FPI (Focus Photonics Inc.) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | FPI-PSA |
| Pricing | Available Upon Request |
| Origin | Italy |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FS-200 |
| Instrument Type | Portable |
| Detectable Gases | H₂, NH₃, SF₆ |
| Response Time | T90 ≤ 5 s |
| Measurement Accuracy | ±1% of Full Scale |
| Measurement Ranges | ppm to 100% volume |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | FT648 |
| Pricing | Available Upon Request |
| Sensitivity | 3.3 Bq/m³ (radon, 95% confidence level) |
| Intrinsic Error | <30% (typical) |
| Background Count Rate | ≤25 cph |
| Power Supply | Sampling Pump Battery: 18 V Ni–Cd |
| Main Unit Battery | 12 V Ni–Cd |
| Operating Temperature | 0–40 °C |
| Detector | Ø65 mm ZnS(Ag) Scintillation Detector |
| Sampling Pump Flow Rate | 30–40 L/min |
| Decay Chamber Volume | 14.8 L |
| Dimensions | Ø170 mm × 800 mm |
| Weight | 18 kg |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | FUC |
| Instrument Type | Portable Water Color Comparator |
| Color Standard | Forel-Ule Scale |
| Number of Color Grades | 21 |
| Color Range | Deep Blue → Yellow-Green → Brownish-Tan (uniform chromatic progression) |
| Vial Material | Optical-grade transparent borosilicate glass |
| Vial Marking | Laser-etched numeric identifiers (1–21) |
| Housing | Anodized aluminum case with shock-absorbing closed-cell foam lining |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FG-3000 |
| Pricing | Available Upon Request |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ZRE |
| Instrument Type | Continuous Emission Monitoring System (CEMS) |
| Indication Error | ±1% FS |
| Repeatability | ≤1% FS |
| Response Time (T90) | ≤1 s |
| Stability (24 h) | ≤1% FS |
| Brand | Fulit |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | FLV 600 |
| Detection Principle | Flame Ionization Detection (FID) |
| Instrument Type | Online Analyzer |
| Configuration | Multi-component VOCs Analyzer |
| Brand | Fumi |
|---|---|
| Origin | Shanghai, China |
| Model | COD-1 |
| Instrument Type | Laboratory Benchtop Analyzer |
| Sample Capacity | 100 positions |
| Digestion Temperature | 165 °C ±0.1 °C |
| Digestion Time | 15 min (configurable) |
| Cooling Endpoint | 60 °C (pre-mix) and 20 °C (pre-measurement) |
| Optical Wavelengths | 440 nm, 600 nm, 680 nm |
| Spectral Bandwidth | ≤10 nm |
| Absorbance Range | 0–3 A |
| Digestion Tube Dimensions | 16 mm × 100 mm (standard), optional 16 mm × 120 mm |
| Operating Environment | 10–30 °C |
| Power Supply | 220 V, 50 Hz |
| Power Consumption | 1280 W |
| Dimensions (W×D×H) | 940 mm × 680 mm × 885 mm |
| Weight | 80 kg |
| Remote Control | Yes |
| LIMS Integration | Network-enabled output |
| Mobile App Support | Yes |
| Built-in Imaging System | Yes |
| Compliance Standard | HJ/T 399–2007 |
| Brand | PRI-ECO |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | G-Flask |
| Pricing | Available Upon Request |
| Origin | Austria |
|---|---|
| Type | Imported Instrument |
| Model | GA-60 |
| Sensor Configuration | Standard 5 electrochemical sensors + optional IR sensors (CO₂, CH₄, N₂O) and additional electrochemical sensors (H₂S, H₂) |
| Flow Rate | 1.63 L/min (Bacharach-compliant) |
| Data Storage | 256 MB (~1 million records) |
| Display | 320 × 240 pixel backlit LCD |
| Printer | 57 mm thermal dot-matrix with graphics |
| Power | Rechargeable 12 V / 2.2 Ah lead-acid battery (10 h charge, ~6 h operation) or 110/220 V AC, 50–60 Hz |
| Dimensions | 500 × 410 × 180 mm |
| Weight | 9.5 kg |
| Operating Temperature | 10–50 °C |
| Storage Temperature | −20–55 °C |
| Humidity | 5–90 % RH (non-condensing) |
| Pressure Resolution | 1 Pa (differential), 0.1 hPa (ambient, optional) |
| Temperature Channels | Up to 8 (4 thermocouples + 4 thermistors, optional) |
| Origin | Austria |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GA-m |
| Pricing | Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GA-S |
| Pricing | Upon Request |
| Brand | CASP |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GA2202 |
| Detection Gases | Methane (CH₄), Ethane (C₂H₆) |
| Detection Principle | Mid-Infrared Absorption + Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Response Time | <1 s |
| Measurement Speed | Up to 60 km/h mobile survey |
| Dual-Gas Simultaneous Quantification | Yes |
| Operating Temperature Control | Active Thermostatic Stabilization |
| Measurement Range | Wide-range configurable for urban ambient monitoring, station boundary monitoring, and landfill/anaerobic digester plume tracking |
| Data Security & Support | Fully domestic R&D and manufacturing, local service network |
| Brand | GAINWAY |
|---|---|
| Model | GW-2081 |
| Origin | Hubei, China |
| Instrument Type | Online CEMS |
| Detection Target | Multi-component gases (CO₂, CH₄, N₂O, CO, O₂) |
| Measurement Ranges | 0–50 ppm (N₂O), 0–1000 ppm (CH₄), 0–20% (CO₂) |
| Response Time | <60 s |
| Flow Rate | 800 mL/min (standard), up to 3000 mL/min (dust-free) |
| Operating Temperature | 15–35 °C |
| Dimensions | 800 mm × 850 mm × 2000 mm (L×W×H) |
| Weight | 125 kg |
| Max Power Consumption | 1200 W |
| Zero Drift (24 h) | ≤0.10% FS (CO₂), ≤1 ppm (CH₄), ≤0.2 ppm (N₂O) |
| Span Drift (24 h) | ±1% FS |
| Flow Velocity Range | 0–40 m/s |
| Temperature Range | 0–300 °C |
| Humidity Range | 0–40% RH |
| Detection Principle | Gas Filter Correlation (GFC) + Long-Path Absorption Cell (L-Cell) for CH₄/N₂O |
| [Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | GXH-3010/3011BF |
| Measurement Principle | Non-Dispersive Infrared (NDIR) |
| Sampling Method | Built-in Diaphragm Pump |
| CO Range | 0–50.0 ppm |
| CO₂ Range | 0–0.500% (customizable up to 0–100.0%) |
| CO Resolution | 0.1 ppm |
| CO₂ Resolution | 0.001% |
| Linearity | ≤ ±2% F.S. |
| Repeatability | ≤ 1% F.S. |
| Zero Drift | ≤ ±2% F.S./4 h |
| Span Drift | ≤ ±2% F.S./4 h |
| Response Time | CO ≤ 30 s |
| Flow Rate | ≤ 1.5 L/min |
| Data Storage | Up to 5000 records |
| Display Units | CO (ppm / mg/m³), CO₂ (% vol / mg/m³) |
| Power Supply | AC 220 V or rechargeable Li-ion battery |
| Dimensions | 270 × 230 × 90 mm |
| Weight | ≤ 3.5 kg |
| Interface | RS232 with proprietary data transfer software |
| Warm-up Time | ≤ 30 min |
| Compliance | GB/T 18204.23–2000, GB/T 9801–1988, GB/T 18204.24–2000, JJG 635–1999 |
| Optional Modules | O₂ sensor, temperature & humidity probe |
| Expandability | Configurable for 24-hour continuous monitoring with daily average calculation] |
| [Origin | Jiangsu, China |
|---|---|
| Power Supply | AC 220 V ±10 V, 50 Hz / DC 9 V (8×AA Ni-Cd/Ni-MH rechargeable batteries) |
| Flow Range | 0–1.5 L/min (gas channel), 5–30 L/min (dust channel) |
| Maximum Vacuum | 23.5 kPa (gas), 15 kPa (dust) |
| Flow Accuracy | ±2.5% |
| Timing Precision | ±0.01% |
| Stability | ≤5% |
| Noise Level | <80 dB(A) |
| Operating Temperature | –5 to 40 °C |
| Dimensions | 220 × 135 × 150 mm |
| Weight | 2.9 kg |
| Battery Runtime | 4–8 h (continuous or intermittent) |
| Charging Current | 500 mA |
| Charging Time | ~12 h] |
