Environmental Test Chamber
Filter
Showing 151–180 of 2009 results
| Brand | OEM / Custom-Branded |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Pricing | USD 2,650 (FOB ex-factory, subject to configuration and certification requirements) |
| Brand | BenAng |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | BA-ZW-A |
| Price | USD 4,750 (FOB Shanghai) |
| Temperature Range | Ambient +20°C to +70°C |
| Temperature Uniformity | ±0.5°C |
| Humidity Range | Up to 95% RH |
| Chamber Dimensions (W×D×H) | 1170 mm × 450 mm × 500 mm |
| UV Lamp Wavelength | 280–315 nm (UV-B) |
| Sample-to-Lamp Distance | 90–100 mm |
| Heating & Humidification | Electric Steam Generator |
| Control System | Imported Digital Touch Panel Controller |
| Compliance | GB/T 5170.9–2017 |
| Brand | OEM / Custom Brand |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Pricing | USD 11,200 (FOB) |
| Compliance | GB/T 2423.1–2022, GB/T 2423.2–2022, GB/T 2423.22–2022, GJB 150.3–2009, GJB 150.4–2009, GJB 150.5–2009, IEC 60068-2-14 (Test N), MIL-STD-810H Method 503.6 |
| Refrigeration System | Dual-stage cascade refrigeration with imported semi-hermetic compressors (Germany), water-cooled condenser requiring external cooling tower (10 m³/h flow rate) |
| Brand | OEM / Custom Brand |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Pricing | USD 11,200 (FOB) |
| Compliance | GB/T 2423.1, GB/T 2423.2, GB/T 2423.22, GJB 150.5, IEC 60068-2-14, QC/T 17, EIA-364-32 |
| Refrigeration System | Dual-stage cascade refrigeration with imported German semi-hermetic compressors |
| Cooling Method | Water-cooled (external cooling tower required: 10 m³/h capacity) |
| Temperature Transition Rate | ≥10 °C/min (typical, basket transfer mode) |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model Series | KB PRO / KBF / KBF PRO with ICH or ICH-LQC Illumination Modules |
| Temperature Range (No Humidity Control) | +18°C to +32°C |
| Temperature & Humidity Range (KBF Series) | +20°C to +50°C / 20–50% RH |
| Extended Temp/Humidity Range (KBF PRO Series) | +10°C to +50°C / 10–80% RH |
| Compliance | ICH Q1B Option 2 (Visible Light) and UV Supplement via Fluorescent Lamps |
| Illumination Types | LED (visible spectrum) + T8 Fluorescent (UV-A/UV-B) |
| Optional Light Dose Control (LQC) | Yes |
| Chamber Volumes | 260 L, 470 L, 720 L |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Chamber Volumes | 260 L, 470 L, 720 L, 1060 L, 1600 L |
| Temperature Range (KB PRO) | 0 °C to +50 °C (no humidity control) |
| Temperature Range (KBF) | 10 °C to +50 °C, Humidity Range: 10–50 % RH |
| Temperature Range (KBF PRO) | 10 °C to +50 °C, Humidity Range: 10–90 % RH |
| LED System | 16 modular strips, each with independently controllable warm white (3000 K), cool white (6500 K), and deep red (660 nm) channels |
| PAR Irradiance | Up to 1000 µmol·m⁻²·s⁻¹ (simulating full sunlight) |
| Control Interface | Touch-enabled external controller with programmable light recipes, twilight simulation, and fresh-air exchange mode |
| Compliance | Designed per IEC 61000-6-3 (EMC), EN 61010-1 (safety), and compatible with GLP/GMP documentation workflows |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | KB PRO Series |
| Temperature Range | –20 °C to +100 °C |
| Temp. Uniformity at 37 °C | ±0.2 K |
| Temp. Stability at 37 °C | ±0.1 K |
| Max. Heat Compensation at 37 °C | 450–1000 W |
| Recovery Time (30 s door opening, 37 °C) | 2–6 min |
| Internal Volume | 127–1610 L |
| Power Supply | 208–240 V, 50/60 Hz |
| Rated Power | 1.0–1.8 kW |
| Net Weight | 135–443 kg |
| Noise Level (25 °C) | 46–52 dB(A) |
| Refrigerant | R-290 |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | KBF PRO |
| Temperature Range | −20 to 100 °C |
| Humidity Range | 10–98 % RH |
| Temp. Uniformity (25 °C / 60 % RH) | ±0.2 K (KBF PRO 130 & 260), ±0.3 K (KBF PRO 470–1600) |
| Temp. Stability (25 °C / 60 % RH) | ±0.1 K |
| Humidity Stability (25 °C / 60 % RH) | ±1 % RH |
| Recovery Time (25 °C / 60 % RH, 30 s door open) | 1 min |
| Recovery Time (40 °C / 75 % RH, 30 s door open) | 3–5 min |
| Internal Volume | 127–1610 L |
| Power Consumption | 1.6–1.9 kW |
| Refrigerant | R-290 (eco-friendly hydrocarbon) |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | KBF Series |
| Type | Benchtop Environmental Test Chamber |
| Temperature Range | 0–70 °C |
| Humidity Range | 10–80 % RH |
| Temp. Uniformity (25 °C / 60 % RH) | ±0.1–0.4 K |
| Humidity Stability (25 °C / 60 % RH) | ±1.5 % RH |
| Recovery Time (25 °C / 60 % RH, 30 s door open) | 1–3 min |
| Power Consumption | 1.3–1.7 kW |
| Internal Volume | 127–1610 L |
| Refrigerant | R-600a |
| Compliance | DIN 12880, ICH Q1–Q5, GLP/GMP-ready |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model Series | M, MK, MKT |
| Application Scope | Thermal Stress Testing, Stability & Durability Evaluation, Material Aging (per EN 60811-1-2 / IEC 60811-1-2) |
| Compliance | ISO 17025-accredited laboratory use, GLP/GMP-compatible operation, FDA 21 CFR Part 11-ready software options available |
| Cooling Method | Dual-circuit refrigeration with cascade system (for MKT series down to –70 °C) |
| Temperature Range | –70 °C to +180 °C (MKT), –40 °C to +180 °C (MK), –20 °C to +180 °C (M) |
| Uniformity | ±0.3 °C (at 100 °C, load-free) |
| Control System | BINDER CTC Advanced Touchscreen Controller with programmable ramp/soak profiles, real-time data logging, and Ethernet interface |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | MK Series |
| Temperature Range | –40 °C to +180 °C |
| Internal Volume | 56–1020 L |
| Temperature Uniformity | ±0.1 K to ±2.0 K (depends on setpoint) |
| Temperature Stability | ±0.1 K to ±0.5 K (depends on setpoint) |
| Heating Rate (IEC 60068-3-5) | up to 5.5 K/min |
| Cooling Rate (IEC 60068-3-5) | up to 4.5 K/min |
| Refrigerant | R-452A (non-ozone-depleting) |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model Series | MKF / MK / MKT |
| Internal Volume Options | 53 L, 115 L, 240 L, 400 L, 720 L |
| Temperature Range | MK/MKF: −40 °C to +180 °C |
| MKT | −70 °C to +180 °C |
| M-Series | +5 °C above ambient to +300 °C |
| Humidity Range (MKF only) | 10–98 % rH |
| Control System | MB1 4-channel touchscreen controller (25 programs × 100 segments) |
| Cooling Technology | DCT® Direct Cooling Technology |
| Preconditioning Chamber | APT-Line® |
| Air Circulation | Digitally adjustable high-power turbine |
| Compliance | DIN EN 60068-3-5, IEC 60068-3-6, ISO 16750-4, ASTM D4329, USP <1151> (environmental stress testing), GLP-compliant data logging via APT-COM software |
| Interface | RS422 for APT-COM v3.x integration |
| Insulation | High-efficiency vacuum-insulated door & polyurethane foam walls |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | MKFT |
| Temperature Range | –70 °C to +180 °C |
| Humidity Range | 10–98 % RH |
| Temperature Uniformity | ±0.1–2.0 K (depending on setpoint and chamber size) |
| Temperature Fluctuation | ±0.1–0.5 K |
| Humidity Fluctuation | ≤±2.5 % RH |
| Heating Rate (IEC 60068-3-5) | up to 5.5 K/min |
| Cooling Rate (IEC 60068-3-5) | up to 4.2 K/min |
| Internal Volumes | 115 L / 228 L / 734 L |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | MKFT115 / MKFT240 / MKFT720 |
| Temperature Range | –70 °C to +180 °C |
| Humidity Range | 10 % RH to 98 % RH |
| Internal Volume | 115 L / 228 L / 734 L |
| Refrigerant | R-452A |
| Humidity Control | Capacitive Sensor + Steam Humidification |
| Controller | MCS Touchscreen with Real-Time & Segment Programming |
| Data Logging | Integrated Internal Recorder + USB Export |
| Compliance | DIN 12880, IEC 60068-3-5, IEC 60068-3-6, MIL-STD-810G (climate profiles), GLP/GMP-ready audit trail support via optional software |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | MKT |
| Temperature Range | -70 °C to +180 °C |
| Compliance | DIN 12880 Class 2 Temperature Safety Device, IEC 60068, MIL-STD-810 |
| Humidity Control | Capacitive Hygrometer + Steam Humidification (MKT models) |
| Refrigerant | R-452A |
| Controller | MCS Touchscreen with Real-Time Clock, Ramp Function, Internal Data Logger |
| Interface | Ethernet, USB, 230 V Socket on Right Side |
| Safety | Optical & Acoustic Fault Diagnostics, Heated Viewing Window with LED Lighting, Silicone-Sealed Access Ports (50 mm for MKT 115/240 |
| Castors | 4, 2 with Brakes |
| Internal Volume | 115 L / 228 L / 734 L (MKT 115 / MKT 240 / MKT 720) |
| Net Weight | 305 kg / 380 kg / 610 kg |
| Brand | Blue M |
|---|---|
| Origin | USA |
| Model | SVO |
| Temperature Range | -70°C to +180°C |
| Max Operating Temperature | +150°C (standard), up to +200°C (optional) |
| Temperature Uniformity | ±1.0°C |
| Temperature Stability | ±0.5°C |
| Temperature Deviation | ±1.0°C |
| Pressure Range | Ambient (760 Torr) down to 0.169 Torr (equivalent to ~200,000 ft altitude) |
| Internal Chamber Dimensions (W×H×D) | 1016 mm × 2057 mm × 2007 mm to 1626 mm × 2616 mm × 2515 mm |
| Heating Method | Immersed electric heater with thermal fluid circulation |
| Vacuum Control | Auto-regulated solenoid valves for precise altitude simulation |
| Controller | Synergy Quattro touchscreen (320×240 color LCD), PID with auto-tuning, dual-channel capability, real-time clock, USB/RS-232/Ethernet (10/100) connectivity |
| Compliance | Designed for ASTM D573, D865, ISO 188, USP <121>, and GLP/GMP-relevant data integrity requirements (audit trail, user access control, electronic signatures via optional software modules) |
| Brand | Blue M |
|---|---|
| Origin | USA |
| Model | WSP |
| Temperature Range | -70°C to 180°C |
| Temperature Uniformity | ±1.0°C |
| Temperature Fluctuation | ±0.5°C |
| Temperature Deviation | ±1.0°C |
| Heating Rate | Ambient to 180°C |
| Chamber Dimensions (W×H×D) | 1016 mm × 2057 mm × 2007 mm – 1626 mm × 2616 mm × 2515 mm |
| Cold Zone Range | -75°C to 0°C |
| Hot Zone Range | +85°C to +215°C |
| Internal Chamber Volume per Zone | 2.1 ft³ (≈59.5 L) |
| Transfer Time | ≤10 s |
| Cooling Medium | Liquid Nitrogen (LN₂) |
| Purge Gas | Dry Nitrogen |
| Defrost Heater | Integrated in Cold Zone |
| Compliance | MIL-STD-202F Method 107G (Conditions A, B, C, F), MIL-STD-883 Method 1010.7 (Conditions A, B, C, F) |
| Key | Brand: Boante |
|---|---|
| Model Range | BAT80/150/250/360/460/600-HSW |
| Origin | Hubei, China |
| Temperature Range | 4–60 °C |
| Temp. Uniformity | ±0.5 °C (within chamber) |
| Temp. Stability | ±0.1 °C |
| Humidity Range | 30–90 %RH (at 15–45 °C ambient operating range) |
| Humidity Control Accuracy | ±1 %RH |
| Humidity Fluctuation | ±3 %RH |
| Display | 7-inch capacitive touchscreen |
| Control Algorithm | Adaptive PID |
| Sensor | PT100 platinum resistance thermometer |
| Cooling System | DC inverter-driven refrigeration |
| Air Circulation | Axial-flow micro-circulation fan system |
| Chamber Material | Mirror-finish stainless steel interior with radius-corner design |
| Safety Protections | Compressor overheat, fan overheat, overtemperature, high-pressure cutoff, overload protection |
| Optional Interfaces | RS485, USB, thermal printer output, remote monitoring capability |
| Brand | Boante |
|---|---|
| Origin | Hubei, China |
| Model | BAT80HS-GA |
| Instrument Type | Vertical Chamber |
| Temperature Range | −70 °C to +150 °C (selectable variants: −60 °C, −40 °C, −20 °C, 0–100 °C) |
| Humidity Range | 20–98 %RH |
| Temperature Uniformity | ≤ ±1.5 °C (at same horizontal plane) |
| Temperature Fluctuation | ≤ ±0.5 °C (high-temp segment), ≤ ±1.0 °C (low-temp segment) |
| Humidity Fluctuation | ±3 %RH |
| Heating Rate | ≥2–3 °C/min (non-linear, no-load, ambient to max temp) |
| Internal Dimensions | 400 × 400 × 500 mm (W × D × H) |
| External Dimensions | 950 × 870 × 1650 mm (W × D × H) |
| Brand | C&W |
|---|---|
| Origin | Netherlands |
| Model | CW Series Cyclic Corrosion Test Chamber |
| External Dimensions (L×W×H) | 1000×600×645 mm to 2750×1220×1630 mm |
| Internal Dimensions (L×W×H¹×H²) | 600×450×375×565 mm to 2000×1000×850×1175 mm |
| Power Supply | Single-phase or three-phase 380 V, 50/60 Hz |
| Compressed Air Requirement | Oil-free, dry, clean air |
| Humidity Range | 15% to 98% RH (controlled) |
| Temperature Control | Integrated refrigeration compressor system (continuous or standby operation) |
| Optional Features | Deionizer & sediment filter (recommended for water with >50 mg/L TDS), low-water-level alarm, external salt fog collection vessel, condensate-controlled fog generation, variable ventilation, ergonomic control panel, GRP composite enclosure with chemical/thermal resistance, pneumatic lid support, modular sample mounting fixtures |
| Brand | C&W |
|---|---|
| Origin | Netherlands |
| Model | CW1001–CW1020 Series |
| Internal Volume | 100 L to 2000 L |
| External Dimensions (L×W×H) | 1000×600×645 mm to 2750×1220×1630 mm |
| Internal Dimensions (L×W×H¹×H²) | 600×450×375×565 mm to 2000×1000×850×1175 mm |
| Power Supply | 13–32 A, Single- or Three-Phase 230/380 V, 50/60 Hz |
| Compressed Air Requirement | Oil-free, dry, filtered |
| Pressure | 2–4 bar (30–60 psi) for spray generation |
| Temperature Range | 30–80 °C (chamber), ±1 °C accuracy |
| Saturated Air Tower | 65 °C ±1 °C, NiCr heating element with overheat protection and auto-refill humidifier |
| Salt Solution Reservoir | 114 L mobile external tank, integrated filtration, ~14 days continuous operation |
| Control System | Microprocessor-based, 7 programmable test methods, cycle timer with remaining count, spray/dry/purge sequencing |
| Optional | Low-level alarm, ergonomic control panel, GRP corrosion-resistant chamber body, insulated apex lid with gas spring support |
| Compliance | Designed to meet ASTM B117, ISO 9227, JIS Z2241, DIN 50021 requirements |
| Brand | C&W |
|---|---|
| Origin | Netherlands |
| Model | CW1001 |
| Spray Method | Direct Air-Atomized Nozzle |
| Fog Output Rate | 1–2 mL/h |
| Nozzle Operating Pressure | 8.44 kg/cm² (≈120 psi) |
| Fog Collection Rate | 1–2 mL per 80 cm² per hour |
| Temperature Range | Ambient to 55 °C |
| Compliance | ASTM B117, ISO 9227, EN ISO 7253, DIN 50021, JIS Z 2371, SAE J2334, Ford CETP, GMW 14872, VW PV1210, BMW GS 90031, Renault D17 2025, etc. |
| Key | Temperature Range: −40 °C to +150 °C (optional −120 °C) |
|---|---|
| Humidity Range | 30–98% RH (optional 5–98% RH) |
| Temperature Resolution | 0.01 °C |
| Humidity Resolution | 0.1% RH |
| Temperature Uniformity | ±0.5 °C |
| Temperature Deviation | ≤±2 °C |
| Humidity Deviation | ≤±2.5% RH |
| Heating Rate | 2.0–3.0 °C/min |
| Cooling Rate | 0.7–1.0 °C/min |
| Control System | TEMI880 Color LCD Touchscreen Controller |
| Power Supply | 380 V ±5%, 50 Hz, 3P+N+G |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Temperature Range | +5°C to 55°C |
| Humidity Range | 85–95% RH |
| Temperature Uniformity | ≤ ±2°C |
| Temperature Fluctuation | ≤ ±0.5°C |
| Salt Spray Deposition Rate | 1–2 mL / 80 cm²·h |
| Spray Modes | Continuous or Cyclic |
| Test Timing Range | 1–999 (s/min/h) adjustable |
| Chamber Volume Options | 60 L / 90 L / 120 L |
| Heating Power | 1.3–1.8 kW |
| Saturation Tank Temperature | Up to 63°C |
| Compliance Standards | ASTM B117, ISO 9227, GB/T 2423.17, GB/T 2423.18, GB/T 2423.26 |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 28,000 (FOB) |
| Acceleration Range | 30–400,000 m/s² |
| Number of Test Stations | 4–64 |
| Max. Specimen Height | 200–300 mm |
| Specimen Mounting Radius | 200–1000 mm |
| Test Axes | X, Y, Z (sequential or independent orientation) |
| Startup Time | ≤3–5 min |
| Continuous Operation Duration | 30–60 min |
| Power Supply | AC 380 V, 1.5–6.5 kVA |
| Dimensions (L×W×H) | 924×910×1242 mm to 1953×470×993 mm |
| Weight | 1000–2300 kg |
| Slip Ring Configuration | 15-channel, 500 V / 5 A |
| Compliance | MIL-STD-202F, MIL-STD-810F, MIL-STD-883C, GJB 150, GJB 360, GB/T 2423, IEC 60068-2-27 |
| Brand | Charm Sciences |
|---|---|
| Origin | USA |
| Model | ROSA Portable Mycotoxin Detection Kit |
| Certification | USDA-GIPSA & FGIS Approved |
| Detection Targets | Aflatoxin, Deoxynivalenol (DON), Zearalenone (ZEN), T-2/HT-2 Toxins, Ochratoxin A (OTA), Fumonisins |
| Sample-to-Result Time | ≤5 min |
| Format | Lateral Flow Immunoassay (LFIA) |
| Regulatory Alignment | Compliant with AOAC Official Methods, ISO 17025–accredited workflows, USP <1033>, FDA 21 CFR Part 11 (when paired with ROSA Connect software) |
| Consumables Included | Pre-calibrated test cassettes, extraction buffers, centrifuge tubes, pipette tips, portable vortex mixer, digital balance (0.01 g resolution), mini-centrifuge (up to 10,000 rpm), sample grinders, and field-grade PPE kit |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 4,100 (FOB) |
| Chamber Dimensions | Ø400 mm × L600 mm (Cylindrical) |
| External Dimensions | 900 × 700 × 1600 mm (W×D×H) |
| Inner Chamber Material | 3 mm SUS316 Stainless Steel |
| Outer Casing | Optional SUS304 Stainless Steel or Powder-Coated Steel |
| Insulation | Mineral Wool + Rigid Polyurethane Foam (≥80 mm thickness) |
| Steam Generator | Titanium Heating Element |
| Control System | Delta DOP-107SV Color Touchscreen PLC with PT100 Sensors |
| Humidity & Saturation Temperature Control | Microprocessor-Based PID Algorithm |
| Pressure Indication | Analog Bourdon-Tube Pressure Gauge (0–3.0 bar) |
| Water Supply | Manual Inlet Valve with Auto-Replenishment Function (Continuous Operation Enabled) |
| Compliance | GB/T 10586–1989, GB/T 2423.3–1993 (IEC 60068-2-3), MIL-STD-810D Method 502.2, GJB 150.9–1986, GB/T 2423.34–1986, MIL-STD-883C Method 1004.2 |
| Brand | COFOMEGRA |
|---|---|
| Origin | Italy |
| Model | CORROSIONBOX |
| Chamber Capacity | 450 L / 1000 L |
| Internal Dimensions (W×D×H) | 800×700×800 mm / 1100×800×1100 mm |
| External Dimensions (W×D×H) | 1320×720×1450 mm / 1640×820×1750 mm |
| Weight | 260 kg / 465 kg |
| Salt Solution Reservoir Capacity | 110 L / 260 L |
| Construction Material | 10 mm thick polypropylene (PP) |
| Chamber Insulation | Double-wall insulated |
| Temperature Range (Salt Fog Mode) | 35°C ± 2°C (standard) |
| Temperature Range (Condensation Mode) | 40°C ± 1°C |
| 雾化方� | �: Compressed air-driven saturated mist generation via central nozzle and diffusion tower |
| Heating System | Immersed heating elements with PID-controlled uniformity |
| Drainage | Integrated floor-level sump with gravity drainage |
| Compliance | Designed to meet ASTM B117, ISO 9227, JIS Z2201, DIN 50021 requirements |
| Brand | COFOMEGRA |
|---|---|
| Origin | Italy |
| Model | SOLARBOX Xe/R.H. |
| Chamber Volume | 40 L (SOLARBOX 1500e) / 75 L (SOLARBOX 3000e) |
| Temperature Range | 35–100 °C |
| Humidity Control | Optional Relative Humidity Monitoring |
| Irradiance Control | Continuous, Closed-Loop via Integrated Radiometer |
| UV Cut-off Filters | 280 nm, 300 nm, 310 nm, and IR-reducing filter |
| Sample Capacity | ≥120 pcs (15 × 30 mm) for 1500e |
| Programmable Cycles | Up to 15 multi-step programs |
| Interface | RS232-C for data logging and remote control |
| Compliance | ASTM G155, ISO 4892-2, ISO 11341, SAE J2527, DIN 75220, UNI EN 13523-13 |