Fiber Optic Spectrometer
Filter
Showing 1–30 of 80 results
| Brand | Advanced Fiber Tools |
|---|---|
| Origin | Germany |
| Detector Type | CMOS |
| Spectral Range | 1500–2600 nm |
| Resolution | 2300 |
| Sensitivity | 2000 |
| Core Material | Low-OH Fused Silica |
| Cladding Material | Fluorinated Fused Silica |
| Coating Options | Acrylate (−40°C to +85°C), Silicone (−40°C to +180°C), Polyimide (−190°C to +385°C) |
| Numerical Aperture | 0.22 ± 0.02 |
| Core/Clad Ratio | 1.1, 1.2, or 1.4 |
| Biocompatibility | ISO 10993-compliant |
| Sterilization Compatibility | ETO, Steam, Electron Beam, Gamma |
| Radiation & Laser Damage Resistance | Yes |
| Brand | ALS |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | SEC2020 |
| Spectral Range | 200–1025 nm |
| Detector Type | Custom CMOS Array (Optimized for UV-VIS-NIR) |
| Optical Resolution (FWHM) | 1.3 nm |
| Sensitivity Range | 200–1025 nm |
| Signal-to-Noise Ratio | 1000:1 (at full integration time, 60 s) |
| Dynamic Range | 7.5 × 10⁹ (system-level, 16-bit digitization with multi-exposure synthesis) |
| Stray Light | < 0.09% at 500 nm |
| Brand | Anritsu |
|---|---|
| Origin | Japan |
| Model | MS9740B |
| Wavelength Range | 600–1750 nm |
| Wavelength Accuracy | ±20 pm (1520–1620 nm, RBW 0.03–0.2 nm) / ±100 pm (1520–1620 nm, RBW 0.5/1.0 nm) |
| Wavelength Resolution (RBW) | 0.03 / 0.05 / 0.07 / 0.1 / 0.2 / 0.5 / 1.0 nm (3 dB bandwidth) |
| Dynamic Range | ≥60 dB at 0.4 nm offset from peak |
| Minimum RBW | 30 pm |
| Scan Speed | ≤0.2 s for 5 nm span (RBW 0.1 nm, VBW 10 kHz) |
| Max Input Power | +23 dBm (with optical attenuator enabled) |
| Fiber Compatibility | SMF-28 (9/125 µm, ITU-T G.652), 50/125 µm GI fiber |
| Connector Options | Interchangeable FC, SC, ST, DIN, LC |
| Storage Capacity | Up to 1,000 files or 10,000 spectra |
| Interfaces | Ethernet (standard), GPIB (optional) |
| Dimensions | 426 × 177 × 350 mm (W×H×D, excluding protrusions) |
| Weight | ≤15.0 kg (excluding options) |
| Power Consumption | ≤75 VA |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Model | Cora 5001 |
| Detector Type | CMOS |
| Laser Class | Class 1 |
| Safety Interlock | Integrated shutter-based activation (laser only active when sample chamber is fully closed) |
| Optical Architecture | Monolithic aluminum optical bench, no moving parts |
| Focus Mechanism | Motorized auto-focus with real-time signal optimization |
| Excitation Options | Dual-wavelength “Dual-Core Raman” configuration available (e.g., 785 nm and 1064 nm) |
| Sample Compatibility | Solids (tablets, films, crystals), liquids (in vials of circular/square/rectangular cross-section), powders, pastes |
| Accessories | Magnetic sample holders, universal vial adapters, solid-sample stage with quick-lock positioning |
| Compliance | IEC 60825-1:2014 (Class 1 laser product), CE marked, RoHS compliant |
| Software | Cora Suite v3.x with spectral library matching (≥10,000 reference spectra), GLP-compliant audit trail, FDA 21 CFR Part 11 optional module |
| Brand | ART Photonics |
|---|---|
| Origin | Germany |
| Model | FORO-L-3/5-F10 |
| Spectral Range | 3–5 µm |
| Lens Material | ZnSe |
| Lens Type | Plano-Convex |
| Focal Length | 10 mm |
| Numerical Aperture | 0.35 |
| Outer Diameter | 25 mm |
| Thread | M24×1 |
| Housing | Anodized Aluminum (Black) |
| AR Coating | Optimized for 3–5 µm |
| Compatible Connectors | SMA, FC/PC |
| Weight | ~45 g |
| Brand | ART Photonics |
|---|---|
| Origin | Germany |
| Model | CIR Fiber 1.5–6 µm |
| Spectral Range | 0.18–1.2 µm (UV-VIS) |
| Detector Type | CCD |
| Resolution | 30 |
| Sensitivity | 400 |
| Signal-to-Noise Ratio | 1001 |
| Core Diameter Options | 200–1500 µm |
| Numerical Aperture | 0.22 ± 0.02 (25° full acceptance angle) |
| Operating Temperature | −40 °C to +600 °C (copper-coated variant) |
| Connector Types | HP-SMA, D-80 |
| Cable Lengths | 1.5 m, 3.0 m (custom lengths from 5 cm to 50 m) |
| Cladding Material | Fluorine-doped fused silica |
| Core Material | High-OH⁻ or Low-OH⁻ fused silica |
| Jacketing Options | Nylon, Tefzel, acrylic, aluminum, copper |
| Protective Sheathing | PVC-coated stainless steel coil, silicone-coated stainless steel bend protection |
| Brand | ART Photonics |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PIR Fiber |
| Spectral Range | 3–17 µm |
| Brand | ASD |
|---|---|
| Origin | UK |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Hi-Res NG |
| Spectral Range | 350–2500 nm |
| Detector | InGaAs (SWIR 1 & 2), Si Array (VNIR) |
| Resolution | 3 nm @ 700 nm |
| Sensitivity | 3 nm @ 700 nm |
| SNR | VNIR: 1.0 × 10⁻⁹ W/cm²/nm/sr @ 700 nm |
| SWIR 1 | 8.0 × 10⁻⁹ W/cm²/nm/sr @ 1400 nm |
| SWIR 2 | 8.0 × 10⁻⁹ W/cm²/nm/sr @ 2100 nm |
| Dynamic Range | 16-bit |
| Stray Light | VNIR: 0.02% |
| SWIR 1 & 2 | 0.01% |
| Sampling Interval | 1.4 nm (350–1000 nm) |
| Scan Time | 100 ms |
| Wavelength Repeatability | ±0.1 nm |
| Wavelength Accuracy | ±0.5 nm |
| Max Radiance | VNIR: 2× solar |
| SWIR | 10× solar |
| Channels | 2151 |
| FOV | 25° (standard 1.5 m fiber optic cable) |
| Calibration Traceability | NIST-traceable reflectance, radiance, and irradiance (radiometric calibration optional) |
| Weight | 5.44 kg |
| Warranty | 12 months comprehensive coverage including technical support |
| Brand | ASD |
|---|---|
| Origin | USA |
| Model | FieldSpec 4 Hi-Res NG |
| Spectral Range | 350–2500 nm |
| Detector Configuration | Si (350–1000 nm), TE-cooled InGaAs (1001–1800 nm), TE-cooled InGaAs (1801–2500 nm) |
| Spectral Resolution | 3 nm @ 700 nm, 6 nm @ 1400 nm & 2100 nm |
| Sampling Interval | 1.4 nm (350–1000 nm), 1.1 nm (1001–2500 nm) |
| Stray Light | <0.02% (VNIR), <0.01% (SWIR 1 & 2) |
| Wavelength Accuracy | ±0.5 nm |
| Wavelength Repeatability | ±0.1 nm |
| Integration Time | 100 ms typical |
| NEΔL (VNIR) | 1.0 × 10⁻⁹ W/cm²/nm/sr @ 700 nm |
| NEΔL (SWIR 1) | 8.0 × 10⁻⁹ W/cm²/nm/sr @ 1400 nm |
| NEΔL (SWIR 2) | 8.0 × 10⁻⁹ W/cm²/nm/sr @ 2100 nm |
| Radiance Dynamic Range | Up to 2× solar (VNIR), 10× solar (SWIR) |
| Calibration Traceability | NIST-traceable radiometric, reflectance, irradiance, and colorimetric calibrations available |
| Fiber Input | 1.5 m, 25° FOV (lens options available) |
| Channels | 2151 spectral bands |
| Weight | 5.44 kg |
| Warranty | 12 months comprehensive coverage with technical support |
| Brand | ASD |
|---|---|
| Origin | USA |
| Model | FieldSpec® 4 HI-RES |
| Detector Type | PDA |
| Wavelength Range | 300–2500 nm |
| Spectral Resolution | 3 nm @ 700 nm, 8 nm @ 1400/2100 nm |
| Scan Time | 100 ms |
| SNR | VNIR: 1.0 × 10⁻⁹ W/cm²/nm/sr @ 700 nm, SWIR1: 1.4 × 10⁻⁹ W/cm²/nm/sr @ 1400 nm, SWIR2: 2.2 × 10⁻⁹ W/cm²/nm/sr @ 2100 nm |
| Stray Light | VNIR: 0.02%, SWIR1/2: 0.01% |
| Wavelength Accuracy | ±0.5 nm |
| Wavelength Repeatability | ±0.1 nm |
| Number of Channels | 2151 |
| Communication | 10/100 Base-T Ethernet, IEEE 802.11g Wi-Fi |
| Dimensions (H×W×D) | 12.7 × 36.8 × 29.2 cm |
| Weight | 5.44 kg (battery included: +1.2 kg) |
| Battery Life | 6 h (NiMH, 12 V, 9 Ah) |
| Operating Temperature | 0–40 °C |
| Storage Temperature | −15–45 °C |
| Power Input | 90–240 VAC, 50/60 Hz or 12 VDC, 5 A |
| Certifications | CE (EN61010-1:2001), EU Directives 2006/95/EC & 2004/108/EC, NIST-traceable calibration, WEEE compliant |
| Brand | ASD |
|---|---|
| Origin | USA |
| Model | FieldSpec® HandHeld 2™ |
| Detector Type | PDA |
| Wavelength Range | 325–1075 nm |
| Wavelength Accuracy | ±1 nm |
| Spectral Resolution | <3.0 nm @ 700 nm |
| NEdL | 5×10⁻⁹ W/cm²/nm/sr @ 700 nm |
| FOV | 25° |
| Integration Time | 8.5 ms (min, adjustable) |
| Memory Capacity | Up to 2000 spectra |
| Display | 2.7″ tilting color LCD |
| Power | 4×AA batteries (rechargeable or alkaline) or 5 V / 1.5 A AC/DC adapter |
| Battery Life | up to 5 h (Li-ion), 2.5 h (NiMH), ~1.5 h (alkaline) |
| Dimensions (H×W×D) | 90 × 140 × 215 mm |
| Weight | 1.2 kg (incl. batteries) |
| Operating Temperature | 0–40 °C |
| Mounting | 1/4″-20 tripod thread |
| Software | RS3™, ViewSpecPro™, HH2 Sync Interface |
| Brand | ASD |
|---|---|
| Origin | USA |
| Model | LabSpec 4 Hi-Res |
| Wavelength Range | 350–2500 nm |
| Spectral Resolution | 6 nm @ 1400/2100 nm (Hi-Res) / 10 nm @ 1400/2100 nm (Standard) |
| Scan Time | 100 ms |
| SNR | VNIR 9000:1 @ 700 nm, SWIR1 9000:1 @ 1400 nm, SWIR2 4000:1 @ 2100 nm |
| Detector Configuration | 512-pixel Si array (350–1000 nm) + dual TE-cooled InGaAs arrays (1000–1800 nm & 1800–2500 nm) |
| Certifications | CE (EN 61010-1:2001), EU Directive 2006/95/EC & 2004/108/EC, NIST-traceable calibration |
| Software Compatibility | Indico® Pro, GRAMS (Thermo Scientific), The Unscrambler® (Camo) |
| Connectivity | 10/100Base-T Ethernet, IEEE 802.11g Wi-Fi (up to 300 m line-of-sight) |
| Power | 12 VDC NiMH battery (6 h typical operation), AC/DC adapter (90–240 VAC, 50/60 Hz) |
| Dimensions | 12.7 × 35.6 × 29.2 cm |
| Weight | 5.2 kg (with battery) |
| Brand | ASD |
|---|---|
| Origin | USA |
| Model | TerraSpec 4 Hi-Res |
| Wavelength Range | 350–2500 nm |
| Spectral Resolution | 3 nm @ 700 nm, 6 nm @ 1400/2100 nm |
| Scan Speed | 100 ms |
| SNR | VNIR 9000:1 @ 700 nm, SWIR1 9000:1 @ 1400 nm, SWIR2 4000:1 @ 2100 nm |
| Stray Light | VNIR 5000:1 (0.02%), NIR 10000:1 (0.01%) |
| Wavelength Repeatability | ±0.1 nm |
| Wavelength Accuracy | ±0.5 nm |
| Detector | 512-pixel Si array (350–1000 nm), TE-cooled InGaAs gradient-index arrays (1001–1800 nm & 1801–2500 nm) |
| Interface | 10/100 Base-T Ethernet, 802.11g Wi-Fi |
| Dimensions (H×W×D) | 12.7 × 36.8 × 29.2 cm |
| Weight | 5.44 kg (instrument), +1.2 kg (battery) |
| Battery Life | ~6 h (standalone) |
| Operating Temperature | 0–40 °C |
| Storage Temperature | −15–45 °C |
| Power Input | 90–240 VAC / 50–60 Hz or 12 VDC / 60 W |
| Brand | ASD |
|---|---|
| Origin | USA |
| Model | TerraSpec 4 Hi-Res |
| Spectral Range | 350–2500 nm |
| Detector | InGaAs |
| Resolution | 3 nm @ 700 nm |
| Sensitivity | 75 photons/count |
| SNR | VNIR 9000:1 @ 700 nm |
| SWIR1 9000 | 1 @ 1400 nm |
| SWIR2 4000 | 1 @ 2100 nm |
| Dynamic Range | 7.5×10⁹ |
| Stray Light | VNIR 5000:1 (0.02%) |
| NIR 10000 | 1 (0.01%) |
| Brand | Avantes |
|---|---|
| Origin | Netherlands |
| Model | AvaSolar |
| Spectral Range | 300–2500 nm |
| Detector Type | Back-illuminated CCD & InGaAs array |
| Spectral Resolution | 0.5–20 nm (model-dependent) |
| Optical Dynamic Range | 3800:1 |
| Signal-to-Noise Ratio | 450:1 to 5000:1 (wavelength-dependent) |
| Stray Light | <0.3% to <0.5% |
| Wavelength Accuracy | ±0.3 nm (UV-VIS), ±1.5–3.0 nm (NIR-SWIR) |
| Pixel Resolution | 2048-pixel CCD (14 × 500 µm) / 256-pixel TE-cooled InGaAs |
| Integration Time | 2 µs – 20 s |
| Linearity | >99% (nonlinear calibration applied) |
| Calibration Traceability | NIM (National Institute of Metrology, China), U = 8.0% (k=2) |
| Brand | Avantes |
|---|---|
| Origin | Netherlands |
| Model | AvaSpec-HS2048XL-EVO |
| Spectral Range | 200–1160 nm |
| Detector | Back-Illuminated CCD (2048 pixels) |
| Resolution (FWHM) | 1–20 nm (configuration-dependent) |
| Sensitivity | 1,250,000 counts/µW·ms |
| Signal-to-Noise Ratio | 525:1 |
| Stray Light | < 1% |
| Dynamic Range | 200–1160 nm |
| Numerical Aperture | 0.22 |
| Focal Length | 37.5 mm |
| Integration Time | 2 µs – 600 s |
| A/D Conversion | 16-bit, 1 MHz |
| Interface | USB 3.0 (5 Gbps) / Gigabit Ethernet (1 Gbps) |
| Data Acquisition Rate | 2.44 ms per scan (with on-board averaging) |
| Digital I/O | HD-26 connector with 2 analog inputs, 2 analog outputs, 3 digital inputs, 12 digital outputs, trigger & sync support |
| Power Supply | USB-powered (700 mA) or external 12 VDC (360 mA) |
| Dimensions & Weight | 175 × 165 × 85 mm, 1.95 kg |
| Brand | Avantes |
|---|---|
| Origin | Netherlands |
| Model | AvaSpec-HSC1024x58TEC-EVO |
| Spectral Range | 200–1160 nm |
| Detector | Back-Illuminated CCD |
| Resolution (FWHM) | 0.2–7 nm (configurable) |
| Sensitivity | 445,000 counts/µW per ms integration time |
| Signal-to-Noise Ratio | 1200:1 |
| Dynamic Range | 40,000 |
| Stray Light | 0.5% |
| Optical Platform | Symmetrical Czerny-Turner, f = 100 mm, NA = 0.13 |
| Cooling | Single-stage thermoelectric (TEC) |
| ADC | 16-bit, 250 kHz |
| Integration Time | 5.2 ms – 60 min |
| Interfaces | USB 3.0 (5 Gbps), Gigabit Ethernet (1 Gbps), HD-26 I/O connector |
| Dimensions | 185 × 161 × 185 mm |
| Weight | 3500 g |
| Brand | Avantes |
|---|---|
| Origin | Netherlands |
| Model | AvaSpec-NIR-Mini |
| Spectral Range | 900–1750 nm |
| Detector | InGaAs (256-pixel array) |
| Optical Resolution | 6 nm (typical, slit- and grating-dependent) |
| Sensitivity (HS mode) | 665,000 counts/µW/ms (integrated over 1000–1750 nm) |
| Signal-to-Noise Ratio (HS) | 1900:1 |
| Dynamic Range (HS) | 4750:1 |
| Stray Light | <1% |
| A/D Converter | 16-bit, 500 kHz |
| Integration Time (HS) | 10 µs – 300 ms |
| Interface | USB 2.0 (480 Mbps), fiber-coupled input, 50 cm integrated cable |
| Dimensions | 95 × 68 × 20 mm |
| Weight | 185 g |
| Operating Temperature | 0–55 °C |
| Software Compatibility | AvaSoft v8+, Windows/Linux DLL support |
| Brand | Avantes |
|---|---|
| Origin | Netherlands |
| Model | AvaSpec-ULS2048CL-EVO |
| Spectral Range | 200–1100 nm |
| Detector | CMOS linear array (2048 pixels) |
| Optical Resolution (FWHM) | 0.06–20 nm (configuration-dependent) |
| Sensitivity | 375,000 counts/µW per ms integration time |
| Signal-to-Noise Ratio | 300:1 |
| Dynamic Range | 4000:1 |
| Stray Light | 0.19–1.0% (grating-dependent) |
| AD Converter | 16-bit, 6 MHz |
| Integration Time | 9 µs – 59 s |
| Interface | USB 3.0 (5 Gbps) / Gigabit Ethernet (1 Gbps) |
| Sampling Speed | 0.38 ms/spectrum (USB3), 1.0 ms/spectrum (Ethernet) |
| I/O | HD-26 connector with 2 analog in/out, 13 digital I/O, trigger/sync/laser control |
| Power | USB 3.0 (500 mA) or 12 VDC (300 mA) |
| Dimensions & Weight | 177 × 127 × 44.5 mm, 1135 g |
| Brand | Avantes |
|---|---|
| Origin | Netherlands |
| Model | AvaSpec-ULS2048x64-EVO |
| Spectral Range | 200–1160 nm |
| Detector | Back-Illuminated CCD (2048 × 64 pixels, 0.89 mm height) |
| Optical Resolution | 0.09–20 nm (configuration-dependent) |
| Sensitivity | 650,000 counts/µW per millisecond |
| Signal-to-Noise Ratio | 450:1 |
| Stray Light | <1% |
| AD Converter | 16-bit, 1.33 MHz |
| Integration Time | 2.4 ms – 25 s |
| Read Noise | 7.5 counts RMS |
| Data Transfer Rate | 2.44 ms/scan (USB 3.0) |
| Interface | USB 3.0 (5 Gbps), Gigabit Ethernet (1 Gbps), HD-26 digital I/O |
| Power | USB-powered (885 mA) or 12 VDC (420 mA) |
| Dimensions & Weight | 175 × 127 × 44.5 mm, 1180 g |
| Brand | Avantes |
|---|---|
| Origin | Netherlands |
| Model | AvaSpec-ULS2048x64TEC-EVO |
| Spectral Range | 200–1160 nm |
| Detector | Back-Illuminated CCD (2048 × 64 pixels) |
| Resolution (FWHM) | 0.09–20 nm (configurable via slit width & grating) |
| Sensitivity | 300,000 counts/µW per ms integration time |
| Signal-to-Noise Ratio | 550:1 |
| Stray Light | <1% |
| Dark Noise Reduction | 2–3× via thermoelectric cooling |
| Cooling Delta | −35 °C relative to ambient |
| Integration Time | 9.7 ms – 500 s |
| A/D Converter | 16-bit, 500 kHz |
| Interface | USB 2.0 (480 Mbps) / RS-232 (115.2 kbps) |
| Optical Design | Symmetric Czerny-Turner, 75 mm focal length |
| Power Supply | 5 VDC, 3.0 A (instrument) |
| Dimensions & Weight | 250 × 179 × 144 mm, 3.6 kg |
| Brand | Avantes |
|---|---|
| Origin | Netherlands |
| Model | NEXOS™ Series |
| Spectral Range | 190–1100 nm |
| Detector Type | CMOS |
| Signal-to-Noise Ratio | 375:1 (NEXOS™, 2K) / 365:1 (PNEXOS™, 4K) |
| Dynamic Range | 4500 |
| Stray Light | 0.1–1% |
| Communication Interfaces | USB (NEXOS™), RS232/SPI (NEXOS™ Link), Optical Bench Only (NEXOS™ Bench Only) |
| Optical Design | Symmetric Czerny-Turner |
| Pixel Options | 2048 or 4096 |
| Slit Options | Configurable slit widths |
| Brand | Avantes |
|---|---|
| Origin | Netherlands |
| Model | VARIUS™ Series |
| Spectral Range | 190–1100 nm |
| Detector Type | CMOS |
| Signal-to-Noise Ratio | 375:1 (VARIUS™ 2K) / 365:1 (VARIUS™ 4K) |
| Dynamic Range | 4500 |
| Stray Light | 0.1–1% |
| Brand | Avenir |
|---|---|
| Origin | Germany |
| Model | Aris |
| Spectral Range | 185–970 nm, 185–550 nm, 185–420 nm, 350–840 nm, 510–1020 nm |
| Detector Type | CCD |
| Optical Resolution (FWHM) | 0.33–1.40 nm |
| Signal-to-Noise Ratio | 350:1 or 600:1 |
| Dynamic Range | 1900:1 or 5000:1 |
| Stray Light | < 0.08 % |
| Optical Design | Symmetric Czerny-Turner with 50 mm focal length |
| Numerical Aperture | 0.16 |
| Input Slit | User-replaceable 20 µm (standard) |
| Interface | USB 2.0 Full Speed (Type-C), optional UART/SPI/I²C |
| ADC | 16-bit, 2 MHz |
| Power | 5 V via USB or auxiliary connector (4.4–5.5 V), ≤ 70 mA |
| Dimensions | 67.0 × 74.0 × 19.0 mm |
| Weight | 122 g |
| Operating Temperature | –20 to +60 °C |
| Storage Temperature | –40 to +70 °C |
| Compliance | EU EMC Directive 2014/30/EU, RoHS, REACH SVHC, U.S. Conflict Minerals Act |
| Brand | Avenir |
|---|---|
| Origin | Germany |
| Type | Fiber Optic Spectrometer |
| Model | ARIS Compact |
| Spectral Range | UV–VIS–NIR (configurable) |
| Optical Resolution (FWHM, typical) | 0.33–1.10 nm |
| Detector Options | Toshiba TCD1304DG (3648 px) or Hamamatsu S11639-01 (2048 px) |
| Integration Time | 3 µs – 35 min (TCD1304DG) |
| Stray Light Suppression | < 0.01% @ 600 nm |
| SNR | 350:1 (TCD1304DG), 600:1 (S11639-01) |
| Dynamic Range | 1900:1 (TCD1304DG), 5000:1 (S11639-01) |
| Pixel Readout Rate | 1 MHz / 2 MHz |
| Trigger Jitter | ≤10 µs |
| Slit | User-replaceable 20 µm default (optional slits available) |
| Brand | Avenir |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Aris |
| Price | Upon Request |
| Spectral Range | 185–970 nm, 185–550 nm, 185–420 nm, 350–840 nm, 510–1020 nm |
| Detector | CCD |
| Optical Resolution (FWHM) | 0.33–1.40 nm |
| Signal-to-Noise Ratio | 350:1 or 600:1 |
| Dynamic Range | 1900:1 or 5000:1 |
| Stray Light | < 0.08 % |
| Brand | Avenir |
|---|---|
| Origin | Germany |
| Type | Fiber Optic Spectrometer |
| Model | Aris Miniature Spectrometer |
| Spectral Range | 185–970 nm, 185–550 nm, 185–420 nm, 350–840 nm, 510–1020 nm |
| Detector | CCD/CMOS |
| Resolution (FWHM) | 0.33–1.40 nm (typ.) |
| Signal-to-Noise Ratio | 350 or 600 (max., unaveraged) |
| Dynamic Range | 1900:1 or 5000:1 (single-pixel, unaveraged) |
| Stray Light | < 0.08 % |
| Optical Design | Symmetrical Czerny-Turner |
| Focal Length | 50 mm |
| Numerical Aperture | 0.16 |
| Input Slit | User-replaceable, default 20 µm |
| A/D Converter | 16-bit, 2 MHz |
| Interface | USB 2.0 Full-Speed, UART |
| Dimensions | 67.0 × 74.0 × 19.0 mm |
| Weight | 122 g |
| Operating Temperature | −20 to +60 °C |
| Storage Temperature | −40 to +70 °C |
| Humidity | 0–90% RH (non-condensing) |
| Brand | Avenir |
|---|---|
| Origin | Germany |
| Detector Type | CCD |
| Spectral Range | 350–840 nm |
| Resolution (FWHM) | 0.65 nm (typ.), 0.80 nm (max.) |
| Signal-to-Noise Ratio | 350 (Toshiba TCD1304DG), 600 (Hamamatsu S11639-01) |
| Dynamic Range | 1900:1 (Toshiba), 5000:1 (Hamamatsu) |
| Stray Light | < 0.08 % |
| Optical Design | Symmetric Czerny-Turner, f = 50 mm, NA = 0.16 |
| Input Slit | User-replaceable 20 µm (standard) |
| Interface | USB 2.0 Full-Speed (Type-C), SMA fiber port |
| Dimensions | 67.0 × 74.0 × 19.0 mm |
| Weight | 122 g |
| Operating Temperature | −20 to +60 °C |
| Compliance | EU EMC Directive 2014/30/EU, RoHS, REACH SVHC, U.S. Conflict Minerals Act |
| Brand | Avenir |
|---|---|
| Origin | Germany |
| Model | NYLIS |
| Spectral Range | 185–970 nm, 185–550 nm, 185–420 nm, 350–840 nm, 510–1020 nm |
| Detector Type | CMOS (Hamamatsu S13496) |
| Resolution (FWHM) | down to 0.05 nm |
| Spectral Sampling | 4096 pixels |
| Slit Width (standard) | 10 µm |
| Stray Light | < 0.1% |
| Dynamic Range | 5500:1 (typ.), 1900:1 to 5000:1 (configurable) |
| Signal-to-Noise Ratio | 350–600 (typ. 550, unaveraged) |
| Optical Design | Symmetric Czerny-Turner |
| Focal Length | 120 mm |
| Numerical Aperture | 0.07 |
| Interface | USB 2.0 Full-Speed (Type-C), UART, optional SPI/I²C |
| Power Supply | 4.4–5.5 V DC (via USB or Aux), ≤70 mA |
| Dimensions | 67.0 × 150.0 × 19.0 mm |
| Weight | 178 g |
| Brand | Avenir |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | NYLIS |
| Spectral Range | 185–970 nm, 185–550 nm, 185–420 nm, 350–840 nm, 510–1020 nm |
| Detector Type | CMOS (Hamamatsu S13496) |
| Optical Resolution (FWHM) | 0.05–1.40 nm (configurable) |
| Sensitivity | 0.05 nm resolution mode |
| Signal-to-Noise Ratio | 350 or 600 (typ.), up to 550 (spec.) |
| dynamic range | 1900:1 or 5000:1 (spec.) |
| Stray Light | < 0.08 % |
| Focal Length | 120 mm |
| Slit Width (standard) | 10 µm |
| Pixel Count | 4096 |
| A/D Converter | 16-bit, 2 MHz |
| Interface | USB 2.0 Full-Speed (Type-C), UART, optional SPI/I²C |
| Dimensions | 67.0 × 150.0 × 19.0 mm |
| Weight | 178 g |