Fiber Optic Spectrometer
Filter
Showing 31–60 of 203 results
| Brand | Avantes |
|---|---|
| Origin | Netherlands |
| Model | AvaSpec-ULS4096CL-EVO |
| Spectral Range | 200–1100 nm |
| Detector | CMOS |
| Optical Resolution (FWHM) | 0.05–20 nm (configuration-dependent) |
| Sensitivity | 261,000 counts/µW per ms integration time |
| Signal-to-Noise Ratio | 300:1 |
| Dynamic Integration Time Range | 9 µs – 40 s |
| Stray Light | 0.19–1.0% (grating-dependent) |
| AD Converter | 16-bit, 6 MHz |
| Interface | USB 3.0 (5 Gbps), Gigabit Ethernet (1 Gbps) |
| Data Transfer Speed | 0.75 ms/scan (USB 3.0), 1.9 ms/scan (Ethernet) |
| Optical Design | Symmetrical Czerny-Turner, 75 mm focal length |
| Dimensions | 177 × 127 × 44.5 mm |
| Weight | 1135 g |
| Brand | Avantes |
|---|---|
| Origin | Netherlands |
| Model | AvaSR-96 |
| Detector | InGaAs |
| Spectral Range | 350–2500 nm |
| Resolution | 1.5 nm @ 350–1100 nm |
| Sampling Interval | 0.6 nm (VIS) / 6 nm (NIR-SWIR) |
| Wavelength Accuracy | ±0.3 nm (VIS) / ±3 nm (NIR-SWIR) |
| Wavelength Repeatability | ±0.1 nm over ±10 °C |
| Detector | Back-thinned CCD (2048 px) + TE-cooled InGaAs array (256 px) |
| Integration Time | 0.01–100 ms |
| Communication | Wireless (Wi-Fi/Bluetooth) |
| Operating Temp. | 0–40 °C |
| Dimensions | 310 × 270 × 135 mm |
| Weight | 5.2 kg |
| Brand | Avantes |
|---|---|
| Origin | Netherlands |
| Model | AvaSun Spectroradiometer |
| Spectral Range | 200–1100 nm |
| Detector Type | Back-Illuminated CCD (2048 pixels, 14 × 500 µm) |
| Optical Resolution | 0.09–20 nm (configurable, 1.5 nm typical @ 200–1100 nm) |
| Spectral Sampling Interval | 0.6 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ±0.1 nm over ±10 °C |
| Sensitivity | 460,000 counts/nW |
| Signal-to-Noise Ratio | 525:1 |
| Dynamic Range | 13,700 |
| Stray Light | <0.5% |
| Integration Time | 2 µs – 20 s |
| Linearity | >99% |
| Communication Interface | Wireless (Wi-Fi/Bluetooth) |
| Operating Temperature | 0–40 °C |
| Storage Temperature | −15–55 °C |
| Dimensions & Weight | 275 × 140 × 85 mm, 2 kg |
| Brand | Avantes |
|---|---|
| Origin | Netherlands |
| Model | NEXOS™ Series |
| Spectral Range | 190–1100 nm |
| Detector Type | CMOS |
| Signal-to-Noise Ratio | 375:1 (NEXOS™, 2K) / 365:1 (PNEXOS™, 4K) |
| Dynamic Range | 4500 |
| Stray Light | 0.1–1% |
| Communication Interfaces | USB (NEXOS™), RS232/SPI (NEXOS™ Link), Optical Bench Only (NEXOS™ Bench Only) |
| Optical Design | Symmetric Czerny-Turner |
| Pixel Options | 2048 or 4096 |
| Slit Options | Configurable slit widths |
| Brand | Avantes |
|---|---|
| Origin | Netherlands |
| Model | VARIUS™ Series |
| Spectral Range | 190–1100 nm |
| Detector Type | CMOS |
| Signal-to-Noise Ratio | 375:1 (VARIUS™ 2K) / 365:1 (VARIUS™ 4K) |
| Dynamic Range | 4500 |
| Stray Light | 0.1–1% |
| Brand | Avenir |
|---|---|
| Origin | Germany |
| Model | Aris |
| Spectral Range | 185–970 nm, 185–550 nm, 185–420 nm, 350–840 nm, 510–1020 nm |
| Detector Type | CCD |
| Optical Resolution (FWHM) | 0.33–1.40 nm |
| Signal-to-Noise Ratio | 350:1 or 600:1 |
| Dynamic Range | 1900:1 or 5000:1 |
| Stray Light | < 0.08 % |
| Optical Design | Symmetric Czerny-Turner with 50 mm focal length |
| Numerical Aperture | 0.16 |
| Input Slit | User-replaceable 20 µm (standard) |
| Interface | USB 2.0 Full Speed (Type-C), optional UART/SPI/I²C |
| ADC | 16-bit, 2 MHz |
| Power | 5 V via USB or auxiliary connector (4.4–5.5 V), ≤ 70 mA |
| Dimensions | 67.0 × 74.0 × 19.0 mm |
| Weight | 122 g |
| Operating Temperature | –20 to +60 °C |
| Storage Temperature | –40 to +70 °C |
| Compliance | EU EMC Directive 2014/30/EU, RoHS, REACH SVHC, U.S. Conflict Minerals Act |
| Brand | Avenir |
|---|---|
| Origin | Germany |
| Type | Fiber Optic Spectrometer |
| Model | ARIS Compact |
| Spectral Range | UV–VIS–NIR (configurable) |
| Optical Resolution (FWHM, typical) | 0.33–1.10 nm |
| Detector Options | Toshiba TCD1304DG (3648 px) or Hamamatsu S11639-01 (2048 px) |
| Integration Time | 3 µs – 35 min (TCD1304DG) |
| Stray Light Suppression | < 0.01% @ 600 nm |
| SNR | 350:1 (TCD1304DG), 600:1 (S11639-01) |
| Dynamic Range | 1900:1 (TCD1304DG), 5000:1 (S11639-01) |
| Pixel Readout Rate | 1 MHz / 2 MHz |
| Trigger Jitter | ≤10 µs |
| Slit | User-replaceable 20 µm default (optional slits available) |
| Brand | Avenir |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Aris |
| Price | Upon Request |
| Spectral Range | 185–970 nm, 185–550 nm, 185–420 nm, 350–840 nm, 510–1020 nm |
| Detector | CCD |
| Optical Resolution (FWHM) | 0.33–1.40 nm |
| Signal-to-Noise Ratio | 350:1 or 600:1 |
| Dynamic Range | 1900:1 or 5000:1 |
| Stray Light | < 0.08 % |
| Brand | Avenir |
|---|---|
| Origin | Germany |
| Type | Fiber Optic Spectrometer |
| Model | Aris Miniature Spectrometer |
| Spectral Range | 185–970 nm, 185–550 nm, 185–420 nm, 350–840 nm, 510–1020 nm |
| Detector | CCD/CMOS |
| Resolution (FWHM) | 0.33–1.40 nm (typ.) |
| Signal-to-Noise Ratio | 350 or 600 (max., unaveraged) |
| Dynamic Range | 1900:1 or 5000:1 (single-pixel, unaveraged) |
| Stray Light | < 0.08 % |
| Optical Design | Symmetrical Czerny-Turner |
| Focal Length | 50 mm |
| Numerical Aperture | 0.16 |
| Input Slit | User-replaceable, default 20 µm |
| A/D Converter | 16-bit, 2 MHz |
| Interface | USB 2.0 Full-Speed, UART |
| Dimensions | 67.0 × 74.0 × 19.0 mm |
| Weight | 122 g |
| Operating Temperature | −20 to +60 °C |
| Storage Temperature | −40 to +70 °C |
| Humidity | 0–90% RH (non-condensing) |
| Brand | Avenir |
|---|---|
| Origin | Germany |
| Detector Type | CCD |
| Spectral Range | 350–840 nm |
| Resolution (FWHM) | 0.65 nm (typ.), 0.80 nm (max.) |
| Signal-to-Noise Ratio | 350 (Toshiba TCD1304DG), 600 (Hamamatsu S11639-01) |
| Dynamic Range | 1900:1 (Toshiba), 5000:1 (Hamamatsu) |
| Stray Light | < 0.08 % |
| Optical Design | Symmetric Czerny-Turner, f = 50 mm, NA = 0.16 |
| Input Slit | User-replaceable 20 µm (standard) |
| Interface | USB 2.0 Full-Speed (Type-C), SMA fiber port |
| Dimensions | 67.0 × 74.0 × 19.0 mm |
| Weight | 122 g |
| Operating Temperature | −20 to +60 °C |
| Compliance | EU EMC Directive 2014/30/EU, RoHS, REACH SVHC, U.S. Conflict Minerals Act |
| Brand | Avenir |
|---|---|
| Origin | Germany |
| Model | NYLIS |
| Spectral Range | 185–970 nm, 185–550 nm, 185–420 nm, 350–840 nm, 510–1020 nm |
| Detector Type | CMOS (Hamamatsu S13496) |
| Resolution (FWHM) | down to 0.05 nm |
| Spectral Sampling | 4096 pixels |
| Slit Width (standard) | 10 µm |
| Stray Light | < 0.1% |
| Dynamic Range | 5500:1 (typ.), 1900:1 to 5000:1 (configurable) |
| Signal-to-Noise Ratio | 350–600 (typ. 550, unaveraged) |
| Optical Design | Symmetric Czerny-Turner |
| Focal Length | 120 mm |
| Numerical Aperture | 0.07 |
| Interface | USB 2.0 Full-Speed (Type-C), UART, optional SPI/I²C |
| Power Supply | 4.4–5.5 V DC (via USB or Aux), ≤70 mA |
| Dimensions | 67.0 × 150.0 × 19.0 mm |
| Weight | 178 g |
| Brand | Avenir |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | NYLIS |
| Spectral Range | 185–970 nm, 185–550 nm, 185–420 nm, 350–840 nm, 510–1020 nm |
| Detector Type | CMOS (Hamamatsu S13496) |
| Optical Resolution (FWHM) | 0.05–1.40 nm (configurable) |
| Sensitivity | 0.05 nm resolution mode |
| Signal-to-Noise Ratio | 350 or 600 (typ.), up to 550 (spec.) |
| dynamic range | 1900:1 or 5000:1 (spec.) |
| Stray Light | < 0.08 % |
| Focal Length | 120 mm |
| Slit Width (standard) | 10 µm |
| Pixel Count | 4096 |
| A/D Converter | 16-bit, 2 MHz |
| Interface | USB 2.0 Full-Speed (Type-C), UART, optional SPI/I²C |
| Dimensions | 67.0 × 150.0 × 19.0 mm |
| Weight | 178 g |
| Brand | Avenir |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | Aris |
| Spectral Range | 185–970 nm, 185–550 nm, 185–420 nm, 350–840 nm, 510–1020 nm |
| Detector Type | CCD |
| Resolution (FWHM) | 0.33–1.40 nm |
| Signal-to-Noise Ratio | 350 or 600 (max, unaveraged) |
| Dynamic Range | 1900:1 or 5000:1 |
| Stray Light | < 0.08 % |
| Brand | Avenir |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Aris |
| Spectral Range | 185–970 nm, 185–550 nm, 185–420 nm, 350–840 nm, 510–1020 nm |
| Detector Type | CCD |
| Optical Resolution (FWHM) | 0.33–1.40 nm |
| Signal-to-Noise Ratio | 350 or 600 (max, unaveraged) |
| Dynamic Range | 1900:1 or 5000:1 |
| Stray Light | < 0.08 % |
| Brand | Avenir |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | ARIS |
| Spectral Range | 185–970 nm, 185–550 nm, 185–420 nm, 350–840 nm, 510–1020 nm |
| Detector Type | CCD |
| Optical Resolution (FWHM) | 0.33–1.40 nm |
| Signal-to-Noise Ratio | 350 or 600 (max, unaveraged) |
| Dynamic Range | 1900:1 or 5000:1 |
| Stray Light | < 0.08 % |
| Brand | Avenir |
|---|---|
| Origin | Germany |
| Model | Sie na |
| Spectral Range | 900–1700 nm, 800–1900 nm, 900–2100 nm |
| Detector Type | InGaAs CCD Array |
| Optical Resolution (FWHM) | 8 nm (typ.), up to 15 nm (max.) |
| Signal-to-Noise Ratio | 1000 (unaveraged) |
| Dynamic Range | 12,000:1 |
| Stray Light | < 0.08 % |
| Entrance Slit | 20 µm (user-replaceable) |
| Interface | USB 2.0 Full-Speed, UART, optional SPI/I²C |
| Power Supply | 5 V DC (4.4–5.5 V), ≤ 60 mW |
| Dimensions | 52.0 × 57.0 × 17.0 mm |
| Weight | 80 g |
| Operating Temperature | –20 °C to +60 °C |
| Compliance | EU EMC Directive 2014/30/EU, RoHS, REACH SVHC, U.S. Conflict Minerals Law |
| Brand | Avenir |
|---|---|
| Origin | Germany |
| Model | Siena |
| Spectral Range | 900–1700 nm, 800–1900 nm, 900–2100 nm |
| Detector Type | InGaAs CCD Linear Array |
| Optical Resolution (FWHM) | 8–15 nm (configurable) |
| Signal-to-Noise Ratio | 1000 (max, unaveraged) |
| Dynamic Range | 12,000:1 |
| Stray Light | < 0.08 % |
| Brand | Avenir |
|---|---|
| Origin | Germany |
| Model | Siena |
| Spectral Range | 900–1700 nm, 800–1900 nm, 900–2100 nm |
| Detector Type | InGaAs CCD Array |
| Optical Resolution (FWHM) | 8–15 nm (configurable) |
| Signal-to-Noise Ratio | 1000 (max, unaveraged) |
| Dynamic Range | 12,000:1 |
| Stray Light | < 0.08 % |
| Brand | Avenir |
|---|---|
| Origin | Germany |
| Detector Type | InGaAs Linear Array (Non-Cooled) |
| Spectral Range | 900–1700 nm / 800–1900 nm / 900–2100 nm |
| Resolution (FWHM) | 8–15 nm (configurable) |
| Signal-to-Noise Ratio | 1000 (max, unaveraged) |
| Dynamic Range | 12,000:1 |
| Stray Light | < 0.08 % |
| Entrance Slit | User-Replaceable (default 20 µm) |
| Optical Design | Symmetric Czerny-Turner, f = 30 mm, NA = 0.19 |
| Interface | USB 2.0 Full-Speed (Type-C), UART, optional SPI/I²C |
| Power | 5 V DC (4.4–5.5 V), ≤60 mW |
| Dimensions | 52.0 × 57.0 × 17.0 mm |
| Weight | 80 g |
| Operating Temperature | −20 to +60 °C |
| Compliance | EU EMC Directive 2014/30/EU, RoHS, REACH SVHC, U.S. Conflict Minerals Act |
| Brand | Avenir |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Siena |
| Spectral Range | 900–1700 nm, 800–1900 nm, 900–2100 nm |
| Detector Type | CCD |
| Optical Resolution (FWHM) | 8 nm |
| Signal-to-Noise Ratio | 1000 |
| Dynamic Range | 12,000:1 |
| Stray Light | < 0.08 % |
| Brand | B&W Tek |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | BTC665N |
| Pricing | Upon Request |
| Spectral Range | 532–1100 nm |
| Detector | Back-Illuminated CCD |
| Optical Resolution (FWHM) | 0.16–0.37 nm |
| Sensitivity | 75 photons/count @ 400 nm |
| Dynamic Range | 50,000 (typical) |
| Stray Light | <0.08% @ 600 nm |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BlueSpecCube |
| Price Range | USD 1,400 – 4,200 (FOB) |
| Spectral Range | 300–1000 nm |
| Detector | Back-Illuminated CMOS Linear Array |
| Optical Resolution | < 4.5 nm (FWHM, with 50 µm slit) |
| Sensitivity | 5 × 10¹⁶ counts/W·s @ 300 nm |
| Signal-to-Noise Ratio | 3000:1 (full well, 1 s integration) |
| Dynamic Range | 10,000:1 (typical, single acquisition) |
| Stray Light | < 0.1 % (600 nm, relative to peak) |
| Brand | BWTEK |
|---|---|
| Origin | USA |
| Model | Quest X |
| Spectral Range | 200–1100 nm (typical configuration) |
| Detector | Sony ILX511B linear CCD |
| Cooling | Thermoelectric (TE) temperature stabilization |
| Interface | USB 3.0 |
| Max Acquisition Rate | 140 spectra/sec (6.3 ms integration time) |
| Stray Light | <0.05% @ 600 nm |
| Trigger Latency | 95 ns |
| Gate Jitter | ±20 ns |
| Onboard Processing | Averaging & smoothing algorithms |
| Optical Design | Non-crossed Czerny-Turner |
| Brand | Spectral Evolution |
|---|---|
| Model | EZ-ID |
| Origin | USA |
| Instrument Type | Fiber Optic Spectrometer Software Platform |
| Compatible Hardware | All Spectral Evolution oreX-Series and Full-Range Field & Lab Spectrometers |
| Spectral Library Support | USGS, SpecMIN, GeoSPEC High Resolution (optional), Custom Library Builder |
| File Format Compatibility | ASD (.asd), ENVI, ASCII, CSV |
| Spectral Range Support | 350–2500 nm (dependent on connected spectrometer) |
| Algorithm Suite | Correlation Coefficient, Spectral Angle Mapper (SAM), Euclidean Distance, Feature Band Matching |
| Compliance | GLP-compliant metadata logging, FDA 21 CFR Part 11–ready audit trail (with optional secure user authentication module) |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | PG2000-Pro |
| Price Range | USD 4,200 – 7,000 |
| Spectral Range | 185–1100 nm |
| Detector | Back-Illuminated FFT-CCD (Hamamatsu S10420) |
| Optical Resolution (FWHM) | 0.13–7.05 nm (configurable via grating/slit) |
| Quantum Efficiency | 75% peak, 65% @ 250 nm |
| Sensitivity | 6.5 V/e⁻ |
| Signal-to-Noise Ratio | 500:1 (at full well, 1 s integration) |
| Dynamic Range | 50,000:1 (system), 5,000:1 (single acquisition) |
| Stray Light | < 0.1% @ 600 nm |
| Pixel Array | 2048 × 64 |
| A/D Conversion | 16-bit, 500 kHz |
| Integration Time | 11 ms – 8 s |
| Weight | 1.0 kg |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | NOVA |
| Price Range | USD 7,000–14,000 |
| Spectral Range | 185–1100 nm |
| Detector Type | Back-Illuminated FFT-CCD |
| Optical Resolution | 0.14–7.7 nm (FWHM) |
| Sensitivity | High Quantum Efficiency (QE >95% peak, 85% @ 250 nm) |
| Signal-to-Noise Ratio (SNR) | 1000:1 (single-pixel, full-well, 1 s integration) |
| Dynamic Range | 10,000:1 |
| Stray Light | <0.85% @ 600 nm |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | FOFI-3 |
| Pricing | Available Upon Request |
| Brand | Hamamatsu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | C10988MA-01 |
| Spectral Range | 340–750 nm |
| Detector Type | CMOS Image Sensor |
| Optical Resolution (FWHM, max) | 14 nm |
| Pixel Count | 256 pixels |
| Stray Light | ≤ –25 dB (max) |
| Dimensions | 27.6 × 13.0 × 16.8 mm |
| Weight | 9 g |
| Operating Temperature | 25 °C (typ.) |
| Brand | Hamamatsu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | C11482GA |
| Spectral Range | 900–1700 nm |
| Detector Type | InGaAs linear array |
| Pixel Count | 512 pixels |
| Spectral Resolution (FWHM, max) | 7 nm |
| A/D Resolution | 16 bits |
| Cooling | Uncooled |
| Interface | USB 2.0 |
| Grating Type | Quartz transmission grating |
| Power Supply | Bus-powered via USB |
| Wavelength Calibration | Factory-stored in onboard memory |
| Dimensions | Compact housing (exact mm dimensions available in datasheet) |
| Brand | Hamamatsu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | OPAL-Luxe C16736-01 |
| Spectral Range | 200–900 nm |
| Optical Resolution | ≤0.9 nm (typ. 0.85 nm) |
| Dynamic Range | 2,500,000:1 |