Fiber Optic Spectrometer
Filter
Showing 61–90 of 206 results
| Brand | Hamamatsu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | PMA-12 Series |
| Spectral Range | 200 nm to 950 nm |
| Detector Type | Back-Thinned CCD Linear Array |
| Optical Design | Czerny-Turner |
| F-number | f/4 |
| Spectral Resolution | < 2 nm (verified with Hg/Ar emission lines) |
| Pixel Count | 1024 channels |
| Pixel Size | 24 µm |
| Active Sensor Area | 2.928 mm |
| Cooling Temperature | −15 °C |
| Read Noise | 16 electrons (rms) |
| Dark Current | 75 electrons/scan (at −15 °C, 20 ms integration) |
| Integration Time | 19 ms to 64 s |
| A/D Resolution | 16-bit |
| Input Fiber | Bundled fiber, φ1 mm core, φ12 mm stainless-steel sheath, 1.5 m length |
| Fiber Coupling | SMA 905 connector |
| Trigger Interface | TTL-compatible, high-impedance input |
| Data Interface | USB 2.0 |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Brand | Hamamatsu |
|---|---|
| Origin | Japan |
| Manufacturer | Hamamatsu Photonics K.K. |
| Model | C10494-01 |
| Spectral Range | 200 nm to 950 nm |
| Detector Type | BT-CCD linear array sensor |
| Optical Resolution | 3 nm (FWHM) |
| Pixel Count | 2048 ch |
| Pixel Size | 12 µm × 972 µm |
| Read Noise | 100 electrons |
| Dark Current | 100 electrons/scan (at 25 °C, 100 µs integration) |
| Integration Time | 100 µs to 1 s |
| A/D Resolution | 12 bit |
| Optical Design | Czerny-Turner |
| f-number | f/4 |
| Fiber Type | Quartz optical fiber |
| Fiber Length | 1.5 m |
| Interface | Camera Link / USB 2.0 |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Brand | Hamamatsu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | RC Series |
| Spectral Range | 640–1050 nm |
| Detector Type | InGaAs-enhanced CMOS linear image sensor |
| Optical Resolution (FWHM, max) | 8 nm |
| Pixel Count | 256 pixels |
| Cooling | Uncooled |
| Operating Temperature | 25 °C (typ.) |
| Interface | Analog video output (composite CVBS) |
| Stray Light | <0.1% (typ., at 650 nm relative to peak) |
| Brand | Hamamatsu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | TG Series |
| Spectral Range | 900–1700 nm |
| Detector | InGaAs linear array |
| Pixel Count | 512 pixels |
| Spectral Resolution (FWHM, max) | 7 nm |
| A/D Resolution | 16 bits |
| Cooling | Uncooled |
| Interface | USB 2.0 |
| Power Supply | Bus-powered via USB |
| Brand | Hamamatsu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model Series | TM / RC / TG / MS |
| Detector Type | InGaAs |
| Spectral Range | 200–2550 nm (model-dependent) |
| Optical Resolution (FWHM) | 1–20 nm (model-dependent) |
| Cooling | Thermoelectric (TE) or uncooled |
| Dynamic Range | >5,000:1 (typical, model- and integration-time-dependent) |
| Signal-to-Noise Ratio | Up to 10,000:1 (peak, with TE cooling and optimal integration) |
| Stray Light | <0.05% (typical, at 600 nm relative to peak) |
| Brand | Hamamatsu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model Series | TM Series |
| Spectral Range | 320–1000 nm (Visible to Near-Infrared) |
| Detector Type | Back-Illuminated CCD |
| Spectral Resolution (FWHM, max) | 1 nm |
| A/D Conversion | 16-bit |
| Interface | USB 1.1 |
| Pixel Count | 2048 |
| Operating Temperature | 25 °C (typ.) |
| Cooling | Uncooled |
| Dynamic Range | >5000:1 (typ.) |
| Signal-to-Noise Ratio | >450:1 (at full well, 1 s integration) |
| Stray Light | <0.05% (600 nm, relative to peak) |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | EV 2.0 |
| Detector Type | CCD |
| Spectral Range | 200–1050 nm |
| Dynamic Range | >3000:1 |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | VS7000+ |
| Detector Type | Back-Illuminated CCD |
| Spectral Range | 200 nm – 1050 nm |
| Spectral Resolution (UV-Vis) | 2.7 nm @ 75 µm slit, 2048-pixel array |
| Numerical Aperture | f/2.8 |
| Stray Light Suppression | ≤ 0.08% (max) |
| Dynamic Range | 7000:1 |
| Quantum Efficiency | >65% at 250 nm, >70% at 650 nm, >55% at 850 nm |
| Readout Speed | up to 223 spectra/s (ultra-fast mode, zero exposure) |
| A/D Conversion | 16-bit, 500 kHz |
| Dark Current | 2.8 counts/ms @ 20°C |
| Read Noise | ≤45 e⁻ (sensitive mode), ≤90 e⁻ (high full-well mode) |
| Linearity Error (factory corrected) | <0.4% (sensitive mode), <0.8% (high full-well mode) |
| On-board Linearization & Wavelength Calibration | Yes |
| Interface | USB 2.0 |
| Optical Design | Monolithic aberration-corrected Czerny–Turner with Type-4 flat-field concave holographic grating |
| Compliance | CE, RoHS, ISO 9001-manufactured |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | OEM Customizable Spectrometer |
| Price | Upon Request |
| Spectral Range | 190–2100 nm |
| Optical Resolution | 10–1 nm (FWHM, configurable per design) |
| Focal Length | 20–140 mm |
| Detector Options | Single-channel PMT, Linear/2D CCD, CMOS, InGaAs, NMOS, PDA arrays |
| Optical Design | Monolithic Czerny–Turner or Crossed-beam configuration with Aberration-Corrected (Type-4) holographic grating |
| Compliance | Designed for integration into ISO/IEC 17025-accredited analytical systems, compatible with FDA 21 CFR Part 11–ready software environments |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model Series | VS20 |
| Resolution | ≤6.5 nm (with 50 µm slit) |
| Stray Light | <0.25% @ 260 nm, <0.1% @ 400 nm, <0.2% @ 600 nm |
| Brand | IdeaOptics |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | BLAZE |
| Spectral Range | 200–1100 nm |
| Resolution | Up to 0.06 nm (with 3600 l/mm grating) |
| Signal-to-Noise Ratio | 400:1 (at saturation) |
| Dynamic Range | 4500:1 |
| Stray Light | 0.05–1% (grating-dependent) |
| Minimum Integration Time | 9 µs |
| Trigger Delay | <1 µs |
| Trigger Jitter | <1 ns |
| Wavelength Drift | ≤0.05 pixel/°C (20–40 °C operating range) |
| Data Throughput | up to 2000 spectra/s (buffered mode) |
| Interface | Gigabit Ethernet |
| Brand | IdeaOptics |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | E820 |
| Pricing | Available Upon Request |
| Spectral Range | 365–960 nm |
| Detector Type | CCD |
| Resolution | High Resolution |
| Sensitivity | 130 photons/count at 400 nm |
| Signal-to-Noise Ratio | 400:1 (at saturation) |
| Dynamic Range | 2 × 10⁸ (system) |
| 3000 | 1 (single acquisition) |
| Stray Light | 0.2% @ 600 nm |
| Brand | IdeaOptics |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | FX2000 |
| Spectral Range | 200–1100 nm |
| Detector Type | UV-enhanced CCD |
| Optical Resolution | 0.22–7.67 nm (FWHM, configurable via slit and grating selection) |
| Sensitivity | 130 photons/count @ 400 nm |
| Signal-to-Noise Ratio (SNR) | 400:1 (full well, 1 s integration) |
| Dynamic Range | 3000:1 (typical, single acquisition) |
| Stray Light | ≤0.2% @ 600 nm |
| Optical Design | Symmetric, non-crossed Czerny-Turner with 72.5 mm focal length |
| Grating | Imported Richardson double-blazed holographic grating |
| Brand | IdeaOptics |
|---|---|
| Model | FX4000 |
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Spectral Range | 200–1100 nm |
| Detector Type | CCD |
| Signal-to-Noise Ratio | >400:1 (at saturation) |
| Dynamic Range | >3000:1 |
| Optical Resolution | Up to 0.17 nm (FWHM) |
| Grating | Dual-blazed holographic grating |
| Integration Time Adjustment Speed | <1 ms |
| Compliance | CE, RoHS |
| Interface | USB 2.0, TTL trigger support |
| Brand | IdeaOptics |
|---|---|
| Model | NIR Series |
| Detector | Hamamatsu InGaAs linear array |
| Spectral Range | 900–2500 nm |
| Spectral Resolution | 3.2 nm (FWHM) |
| Wavelength Accuracy | ±0.5 nm |
| Pixel Count | 512 |
| Dynamic Range | 7500:1 (typ.) |
| SNR | 15,000:1 (with deep TEC cooling) |
| Integration Time | 1 ms to 60 s |
| Cooling | Two-stage thermoelectric (TEC) to –25 °C |
| Optical Interface | SMA 905 fiber coupling |
| Compliance | CE, RoHS, ISO 9001 manufacturing environment |
| Brand | IdeaOptics |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | Yes |
| Country of Origin | China |
| Model | NOVA |
| Spectral Range | 200–1100 nm (customizable) |
| Detector Type | Back-Illuminated CCD |
| Sensitivity | High |
| Signal-to-Noise Ratio (SNR) | 1,000:1 (at saturation) |
| Dynamic Range | 10,000:1 |
| Brand | IdeaOptics |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | PG2000 |
| Spectral Range | 200–1100 nm |
| Detector Type | CCD |
| Optical Resolution (FWHM) | 0.13–7.05 nm |
| Signal-to-Noise Ratio | 400:1 |
| Dynamic Range | 3000:1 |
| Stray Light | 0.1% @ 600 nm |
| Brand | IdeaOptics |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic (China) |
| Model | PG2000-Pro |
| Price | Upon Request |
| Spectral Range | 200–1100 nm |
| Detector Type | Back-Illuminated CCD |
| Optical Resolution (FWHM) | 0.18–7.05 nm |
| Brand | IdeaOptics |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | PG4000 |
| Spectral Range | 200–1100 nm |
| Detector Type | CCD |
| Optical Resolution (FWHM) | 0.10–4.88 nm |
| System Sensitivity | 2 × 10⁸ |
| Single-Scan Dynamic Range | 1300:1 |
| Signal-to-Noise Ratio (SNR) | >400:1 (at saturation) |
| Overall Dynamic Range | >3000:1 |
| Stray Light | <0.1% (measured at 600 nm) |
| Brand | IdeaOptics |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | SINO |
| Optical Resolution (FWHM) | Up to 0.3 nm (dependent on grating and slit selection) |
| Detector Options | CMOS or CCD |
| Slit Width Options | 10–200 µm |
| Pixel Count | 4096 pixels |
| Maximum Acquisition Rate | 2000 frames per second (fps) |
| Physical Dimensions | 92 × 66 × 34 mm³ |
| Focal Length | 42 mm |
| Thermal Drift Stability | ~0.15 pixel/°C |
| Brand | IdeaOptics |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | ZURO |
| Detector Type | CCD |
| Spectral Range | 200–980 nm |
| Optical Resolution | 0.77 nm (FWHM) |
| Signal-to-Noise Ratio | 1000:1 (typical), up to 3000:1 in nonlinear region |
| Dynamic Range | 25,000:1 |
| Brand | INSION |
|---|---|
| Origin | Germany |
| Model | UV-VIS Miniature Spectrometer |
| Spectral Range | 330 nm – 1050 nm |
| Optical Resolution (FWHM) | 8–10 nm |
| Signal-to-Noise Ratio | >5000:1 |
| Integration Time | 1 ms – 40,000 ms |
| Detector | Hamamatsu 256-pixel linear CMOS array |
| Slit Width | 50 µm |
| Wavelength Repeatability | <0.1 nm |
| Interface | Micro-USB + SMA905 fiber connector |
| Dimensions | 69 mm × 40 mm × 13.6 mm |
| Compliance | CE, RoHS |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | UV/VIS/NIR-Spectrometer |
| Spectral Range | 350–850 nm |
| Detector Type | CMOS-based Monolithic Optical Chip |
| Resolution | <10 nm (typ. 8.5 nm) |
| Sensitivity | >65 E12 cts·nm/W·s (typ. 110 E12 cts·nm/W·s) |
| Signal-to-Noise Ratio | ≥5000 at T<sub>integration</sub> = 2 ms |
| Dynamic Range | 900–1700 nm |
| Stray Light | 3.5 nm/pixel |
| Operating Temperature | 0–45 °C |
| Storage Temperature | −40–60 °C |
| Slit Dimensions | 60 µm × 300 µm |
| Interface | USB Type-B, RS232 |
| Power Supply | 5 V DC, ripple <50 mV |
| Max. Power Consumption | 7.5 W |
| Dimensions (L×W×H) | 108 × 76.6 × 21.5 mm³ |
| Weight | 130 g |
| Brand | INSION |
|---|---|
| Origin | Germany |
| Model | UV2NIR+ |
| Spectral Range | 330–1700 nm |
| Resolution | 10 nm (UV/VIS), 16 nm (NIR) FWHM |
| Sensitivity | 80 E12 cts·nm/W·s (UV/VIS), 150 E12 cts·nm/W·s (NIR) |
| SNR | ≥ 5000 at T<sub>integration</sub> = 2 ms |
| Dynamic Range | 900–1700 nm |
| Stray Light | 3.5 nm/pixel |
| Dimensions | 165 × 60 × 36 mm |
| Detector | Dual-channel Hamamatsu S11639 (UV/VIS) + InGaAs linear array (NIR) |
| Optical Architecture | Monolithic planar waveguide with integrated cavity optics |
| Calibration Stability | Lifetime calibration-free operation |
| Compliance | RoHS, CE, ISO 9001 manufacturing environment |
| Brand | IXFiber (distributed by Auniontech) |
|---|---|
| Origin | France |
| Type | Radiation-Hardened Specialty Fiber |
| Model | IXfiber_Rad_Hard_Fiber |
| Spectral Range | 800–1700 nm (optimized for InGaAs detection) |
| Detector Compatibility | InGaAs-based spectrometers |
| Resolution | Up to 7680 pixels (system-dependent) |
| Sensitivity | High (typical responsivity >1.0 A/W at 1550 nm) |
| Signal-to-Noise Ratio | >80 dB (full-well, cooled operation) |
| Dynamic Range | >68 dB (typical, 16-bit digitization) |
| Stray Light Rejection | <−67 dB (optimized grating + fiber coupling design) |
| Origin | Germany |
|---|---|
| Manufacturer Type | Distributor |
| Import Status | Imported |
| Model | RU 60 |
| Spectral Range | 200–1000 nm |
| Detector | CMOS |
| Optical Resolution | < 4.5 nm (with 50 µm slit) |
| Sensitivity | 4 × 10¹⁵ counts/W·s @ 250 nm |
| Signal-to-Noise Ratio | 3000:1 |
| Dynamic Range | 10,000:1 |
| Stray Light | < 0.1 % (GG495 filter, measured at λ = 420 nm / 600 nm) |
| Brand | Jingfei |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM/ODM) |
| Detector Type | CCD-based Fiber Optic Spectrometer |
| Model | FLA Series |
| Compliance | CE-marked for laboratory and industrial use |
| Optical Configuration | Transmission-mode absorbance measurement with optional cuvette or flow-cell integration |
| Spectral Range | 200–1100 nm (configurable per FLA submodel) |
| Optical Resolution | ≤1.5 nm FWHM (typical, dependent on slit and grating selection) |
| Integration Time | 1 ms – 65 s |
| Data Output | USB 2.0 / UART / TTL-compatible digital interface |
| Brand | Jingfei |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | FLA Series |
| Pricing | Available Upon Request |
| Brand | Jingfei Technology |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM/ODM Producer |
| Model | FLA2000 |
| Spectral Range | 200–1100 nm |
| Detector | Hamamatsu CMOS Linear Array (2048 pixels) |
| Optical Resolution | 1.0 nm FWHM |
| Slit Width | 70 µm (standard, customizable) |
| Signal-to-Noise Ratio | 750:1 |
| Dynamic Range | 500,000 |
| Stray Light | < 0.1% |
| Linearity | > 99.8% |
| Sensitivity | 1300 V/(lx·s) |
| Interface | USB 2.0, RS-232, RS-485 |
| Dimensions | 80 × 63 × 34 mm |
| Weight | 320 g |
| Brand | Jingfei Technology |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM/ODM Producer |
| Model | FLA3000 |
| Spectral Range | 200–1100 nm |
| Detector | Hamamatsu CMOS Linear Array |
| Optical Resolution (FWHM) | 0.8 nm |
| Sensitivity | 2600 V/(lx·s) |
| Signal-to-Noise Ratio | 500:1 |
| Dynamic Range | 150,000 |
| Stray Light | <0.1% |
| Pixel Count | 1024 |
| Slit Width | 70 µm (standard, optional) |
| Linearity | >99.8% |
| Interface | USB 2.0, RS-232, RS-485 |
| Dimensions | 128 × 72 × 40 mm |
| Weight | 500 g |