Flue Gas Analyzer
Filter
Showing 1–30 of 78 results
| Brand | ABB |
|---|---|
| Origin | Canada |
| Model | MBGAS-3000 |
| Instrument Type | Multi-component FTIR Flue Gas Analyzer |
| Measurement Principle | Fourier Transform Infrared Spectroscopy |
| Max. Simultaneous Components | 25 |
| Accuracy (Relative Error) | ≤4% FS |
| Repeatability | ≤2% RSD |
| Response Time (T90) | ≤80 s |
| Long-term Stability (7-day drift) | ≤4% FS |
| Operating Mode | Hot/Wet Sampling |
| Detection of Water-Soluble Gases | HCl, HF, NH₃, SO₂, NO, NO₂, CO, CO₂, CH₄, N₂O, etc. |
| Brand | ABB |
|---|---|
| Origin | Canada |
| Model | MBGAS-3000 |
| Instrument Type | Multi-component FTIR Flue Gas Analyzer |
| Measurement Principle | Fourier Transform Infrared Spectroscopy |
| Max. Simultaneous Components | 25 |
| Accuracy (Linearity & Span Error) | ≤ ±3% of full scale |
| Repeatability | ≤ 2% RSD |
| Response Time (T90) | ≤ 90 s |
| Long-term Stability (7-day drift) | ≤ 3% of full scale |
| Operating Mode | Hot/Wet Sampling |
| Optical Resolution | ≤ 0.5 cm⁻¹ |
| Laser Source Lifetime | ≥ 10 years |
| Compliance | Designed for EN 15267-3, EN 14181, ISO 12039, and US EPA Methods 320 & OTM-12 |
| Brand | ADEV |
|---|---|
| Model | GAS600R |
| Type | Portable Flue Gas / Fuel Gas Calorific Value Analyzer |
| Measurement Principle | NDIR (CO, CO₂, CH₄, CₙHₘ), TCD (H₂), Electrochemical (O₂) |
| Accuracy | ≤±1% FS (NDIR sensors), ≤±2% FS (TCD & electrochemical sensors) |
| Repeatability | ≤1% |
| Response Time (T90) | <10 s (NDIR), <15 s (full system) |
| Stability | ±2% over 8 h |
| Detection Range | CO: 0–75%, CO₂: 0–25%, CH₄: 0–40%, H₂: 0–75%, O₂: 0–25%, CₙHₘ: 0–5% |
| Resolution | 0.01% for all gases |
| Operating Pressure | −10 MPa to +15 MPa |
| Sample Temperature | 80–150 °C |
| Sample Flow Rate | 0.3–1.0 L/min |
| Inlet Pressure | 2–50 kPa |
| Power Supply | Internal rechargeable Li-ion battery (12.6 V external charger) |
| Outputs | RS-232 digital, 4–20 mA analog |
| Sample Requirements | Dust-free, dry, oil-free |
| Compliance | Designed for industrial process gas monitoring per ISO 14687, ASTM D1826, and EN 15403 principles |
| Brand | AFRISO |
|---|---|
| Origin | Germany |
| Model | BL100 |
| Instrument Type | Portable Flue Gas Analyzer |
| Measured Gases | O₂, CO |
| O₂ Range | 0–21.0 vol.% |
| CO Range | 0–20,000 ppm |
| O₂ Accuracy | ±0.2 vol.% of reading |
| CO Accuracy | ±5 ppm (≤100 ppm), ±5% of reading (100–2000 ppm) |
| Repeatability | ±2% |
| Response Time (T90) | <3 s (temperature), <30 s (CO), <20 s (O₂) |
| Stability | ±2% over 8 h |
| Display | 2.8" TFT color screen |
| Data Storage | 4 GB micro-SD/HC card |
| Battery | Li-ion, 3.6 V / 1800 mAh, up to 10 h operation |
| Dimensions (H×W×D) | 215 × 70 × 40 mm |
| Weight | ~500 g (incl. magnetic protective case) |
| IP Rating | IP42 (EN 60529) |
| Operating Temperature | −5 to +40 °C |
| Storage Temperature | −20 to +50 °C |
| Brand | AFRISO |
|---|---|
| Model | E30X |
| Type | Portable Flue Gas Analyzer |
| Sensor Technology | Electrochemical (O₂, CO, NO, NO₂, SO₂, H₂S, etc.) |
| Display | 4.3" TFT Color Screen with Chinese/English UI |
| Data Storage | MicroSD card (up to 16 GB) |
| Battery Life | Up to 12 h (Li-ion, rechargeable during operation) |
| Auto-Calibration | Built-in zero and span check |
| Response Time | <20 s (T90) |
| Accuracy | CO measurement ±2 ppm (low-range), NOₗₒw ≤2 ppm error |
| Compliance | EN 50379-1/-2, DIN EN 15545, CE marked |
| Connectivity | Bluetooth 4.2, USB-C, QR code export |
| Operating Temperature | 0–40 °C |
| Dimensions | 230 × 120 × 65 mm |
| Weight | 1.2 kg |
| Magnetic Mount | Integrated rear magnet for hands-free mounting |
| Brand | AFRISO |
|---|---|
| Origin | Germany (Manufactured under German engineering standards, assembled/quality-controlled in Beijing) |
| Manufacturer Type | OEM/ODM Producer |
| Model | M60X |
| Compliance | EN 50379-1/-2, TÜV-certified |
| Sensor Lifespan | ≥5 years (O₂, CO/H₂, SO₂low, NO, NO₂, NOₓ) |
| Response time (T90) | O₂ <20 s |
| O₂ range | 0–21 vol.% (±0.2 vol.%) |
| CO (H₂-compensated) | 0–20,000 ppm (±5 ppm up to 50 ppm, ±5% of reading above) |
| COhigh | 0–4.0 vol.% (40,000 ppm) |
| SO₂ | 0–5,000 ppm |
| NO | 0–5,000 ppm |
| NO₂ | 0–500 ppm |
| NOₓ (calculated) | 0–5,500 ppm |
| CO₂ (NDIR) | 0–max theoretical (fuel-dependent) |
| Flue gas temperature | 0–1000 °C (±1 °C up to 300 °C, ±1% above) |
| Ambient temperature | −20–+200 °C |
| Differential pressure | ±150 hPa |
| Flow velocity | 0.5–70 m/s |
| Display | 3.5″ TFT color (240 × 320 px) |
| Data logging | Internal + optional microSD/SDHC (up to 32 GB) |
| Battery | Li-ion 3.6 V / 2900 mAh (≥12 h operation, chargeable during measurement) |
| Dimensions | 220 × 90 × 53 mm (incl. magnetic protective sleeve) |
| Weight | ~685 g |
| Enclosure | IP42 (EN 60529) |
| Interface | IR, Bluetooth 4.2, USB Mini-B |
| Accessories | 290 mm 600 °C probe, 2.4 m heated sampling hose, dual-stage KFP condensate filter with integrated thermocouple, ambient temp probe, magnetic sleeve, carry case, charger/USB cable, EN 50379 certificate, factory calibration certificate, user manual |
| Brand | AFRISO |
|---|---|
| Origin | Germany |
| Instrument Type | Portable Flue Gas Analyzer |
| Model | M60X20 |
| Accuracy (SO₂/NO/NO₂) | ±10 ppm (0–200 ppm), ±5% of reading (>200 ppm) |
| Accuracy (CO) | ±5 ppm (0–50 ppm), ±5% of reading (>50 ppm) |
| Repeatability | ±2% |
| Response Time (T90) | ≤45 s (SO₂), ≤30 s (NO, CO), ≤60 s (NO₂, COhigh) |
| Stability | ±0.1% of full scale over 8 hours |
| Measured Gases | O₂, CO (H₂-compensated), COhigh, NO, SO₂, NO₂, CO₂ (IR), calculated λ, CO₂, η-efficiency, flue gas loss, dew point, ΔT |
| IP Rating | IP42 |
| Operating Temperature | 5–40 °C |
| Weight | 685 g (with magnetic protective case) |
| Brand | AFRISO |
|---|---|
| Origin | Germany (manufactured under AFRISO engineering specifications |
| Model | STM225 |
| Instrument Type | Portable Laser-Based Dust Monitor |
| Measurement Principle | Dual-Beam Laser Light Scattering |
| Dust Range | 0–300 mg/m³ |
| Resolution | 0.1 mg/m³ |
| Accuracy (Indicated Error) | ±0.5% FS |
| Repeatability | ±0.2% FS |
| Response Time (T90) | ≤0.1 s |
| Drift (1-h Stability) | <±0.5% FS over 1 h |
| Operating Temperature | –5 to +40 °C |
| Storage Temperature | –20 to +50 °C |
| Display | 5.7" color TFT touchscreen |
| Power Supply | AC 230 V, 50 Hz |
| Communication | Bluetooth 4.2, USB 2.0 |
| Enclosure Rating | IP40 |
| Dimensions (W×H×D) | 190 × 275 × 330 mm |
| Weight | 7.5 kg |
| Compliance | Designed to support ISO 16940, EN 13284-1, and ASTM D6216 measurement protocols for particulate matter in industrial flue gases |
| Brand | AFRISO |
|---|---|
| Model | STM225 |
| Type | Portable dust monitor |
| Measurement principle | Dual-beam laser scattering |
| Dust concentration range | 0–300 mg/m³ |
| Resolution | 0.1 mg/m³ |
| Accuracy (indicated error) | ±0.50 mg/m³ |
| Repeatability | ±0.2 mg/m³ |
| Response time | 0.10 s |
| Stability | ±1% over 1 h |
| Operating temperature | −5 to 40 °C |
| Storage temperature | −20 to +50 °C |
| Dimensions (W×H×D) | 190 × 275 × 330 mm |
| Weight | ~7.5 kg |
| Ingress protection | IP40 |
| Display | 5.7" color touchscreen |
| Power supply | AC 230 V, 50 Hz |
| Communication interfaces | Bluetooth, USB |
| Brand | AFRISO |
|---|---|
| Model | STM225 |
| Type | Portable dust monitor |
| Measurement Principle | Dual-beam laser scattering |
| Dust Range | 0–300 mg/m³ |
| Resolution | 0.1 mg/m³ |
| Accuracy (Indication Error) | ±0.5% FS |
| Repeatability | ±0.2% FS |
| Response Time | ≤0.10 s |
| Drift Stability | <1% over 1 h |
| Operating Temperature | –5 to 40 °C |
| Storage Temperature | –20 to +50 °C |
| Dimensions (W×H×D) | 190 × 275 × 330 mm |
| Weight | ~7.5 kg |
| IP Rating | IP40 |
| Display | 5.7" color TFT touchscreen |
| Power Supply | AC 230 V, 50 Hz |
| Communication | Bluetooth 4.2, USB |
| O₂ Range (with M60) | 0–21 vol.% |
| CO/H₂ Range (with M60) | 0–4000 ppm |
| COhigh Range (with M60) | 0–20,000 ppm |
| Brand | AFRISO |
|---|---|
| Origin | Germany (manufactured under AFRISO engineering specifications |
| Model | STM225 |
| Instrument Type | Portable flue gas particulate monitor |
| Measurement Principle | Dual-beam laser scattering (90° and forward-angle detection) |
| Dust Concentration Range | 0–300 mg/m³ |
| Resolution | 0.1 mg/m³ |
| Accuracy (Indication Error) | ±0.5% FS |
| Repeatability | ±0.2% FS |
| Response Time (T90) | ≤0.1 s |
| Drift (1 h) | <±1% FS |
| Operating Temperature | −5 to +40 °C |
| Storage Temperature | −20 to +50 °C |
| Dimensions (W×H×D) | 190 × 275 × 330 mm |
| Weight | ~7.5 kg |
| Ingress Protection | IP40 |
| Display | 5.7″ color TFT touchscreen |
| Power Supply | AC 230 V, 50 Hz |
| Communication | Bluetooth 5.0, USB 2.0 |
| Compliance | EN 15267-3 (QAL1 certified per EU Directive 2010/75/EU), ASTM D6216, ISO 12141, applicable to continuous emission monitoring systems (CEMS) auxiliary particulate verification |
| Brand | AMAE |
|---|---|
| Model | EM-3040 |
| Type | Portable Flue Gas Analyzer |
| Measurement Principle | UV Differential Optical Absorption Spectroscopy (UV-DOAS) |
| Measurable Gases | SO₂, NO, O₂, CO, NO₂, CO₂ |
| Operating Temperature Range | -10 °C to 50 °C |
| Display | 8-inch TFT LCD, 800×600 resolution, 900 cd/m² brightness, 3-level adjustable backlight |
| Weight | ≈5 kg |
| Compliance | HJ/T 397–2007, JJG 968–2002, DB37/T 2641–2015, DB37/T 2704–2015, DB37/T 2705–2015, GB/T 16157–1996 |
| Brand | Ankersmid |
|---|---|
| Origin | Belgium |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Ankersmid |
| Price Range | USD 1,400 – 7,000 (est.) |
| Instrument Type | Continuous Emission Monitoring System (CEMS) Preconditioning Unit |
| Measurement Accuracy | ±1% FS |
| Repeatability | ≤1% RSD |
| Response Time | ≤1 s (T90) |
| Drift Stability | ≤2% over 1 h |
| Measured Medium | Flue Gas (including CO, CO₂, SO₂, NOₓ, O₂, HCl, HF, NH₃, hydrocarbons, particulates, moisture) |
| Brand | AnronX |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | ARX-C200 / ARX-G310 |
| Instrument Type | Continuous Emission Monitoring System (CEMS) |
| Measurement Accuracy | ±2% of Full Scale (F.S.) |
| Response Time | ≤ 200 s |
| Measured Parameters | SO₂, NO, NO₂, O₂, Particulate Matter (PM), Flue Gas Temperature, Static Pressure, Flow Velocity, Relative Humidity |
| Brand | AnronX |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ARX-C200H |
| Instrument Type | Continuous Emission Monitoring System (CEMS) |
| Measurement Accuracy | ±2% F.S. |
| Response Time | ≤120 s |
| Measured Parameters | SO₂, NO, NO₂, O₂, NH₃, Particulate Matter (PM), Temperature, Pressure, Flue Gas Velocity, Relative Humidity |
| Brand | AnronX |
|---|---|
| Origin | Jiangsu, China |
| Model | LFS800 |
| Measurement Principle | Laser Forward Scattering |
| Sample Type | Wet Flue Gas |
| Measured Parameter | Particulate Matter (PM) |
| Range | 0–5 mg/m³ (Low Range), Dual-Range Auto-Switching |
| Detection Limit | 0.01 mg/m³ |
| Accuracy | ±10% (Gravimetric Reference Method) |
| Isokinetic Sampling Flow Rate | Up to 200 L/min |
| Heating | Full-Path Heated Sampling Line |
| Calibration | Automated Zero and Span Calibration |
| Display | Integrated LED Interface |
| Output | Analog 4–20 mA + Digital RS485/Modbus RTU |
| Compliance | Designed for China’s HJ 75–2017 & HJ 76–2017 CEMS Technical Specifications |
| Brand | AnronX |
|---|---|
| Origin | Jiangsu, China |
| Model | LSS2014 |
| Measurement Principle | Laser Backscatter (90°–180° detection geometry) |
| Measurand | Particulate Matter (PM) in Flue Gas |
| Range | 0–20 mg/m³ (Ultra-Low Mode), Dual-Range Operation Supported |
| LOD | 0.05 mg/m³ |
| Installation Type | In-Situ, Non-Extractive |
| Gas Condition Requirement | Dry, Non-Condensing Flue Gas |
| Compliance Context | Designed for continuous emission monitoring systems (CEMS) per Chinese HJ 76-2017 and compatible with international flue gas monitoring frameworks (e.g., EN 15267, ISO 12141, US EPA Method 9 and Performance Specification PS-11) |
| Brand | Artium |
|---|---|
| Origin | USA |
| Model | LII 300 |
| Measurement Principle | Laser-Induced Incandescence (LII) |
| Measured Parameter | Soot Mass Concentration, Primary Particle Diameter, Specific Surface Area |
| Detection Limit | <1.0 ppt (<2 µg/m³) |
| Upper Range | 10 ppm (20 g/m³) |
| Dynamic Range | >1,000,000:1 |
| Accuracy | ±2% of reading |
| Repeatability | ±2% |
| Stability | ±2% |
| Response Time | <100 ms |
| Soot Primary Particle Size Range | 10–100 nm |
| Specific Surface Area Resolution | Derived from LII signal ratio and calibration traceable to NIST standards |
| Compliance | Designed for ASTM D6551, ISO 8573-4, and EPA Method 9-compatible particulate characterization workflows |
| Software | Real-time acquisition with timestamped raw signal, background-subtracted incandescence decay, and dual-wavelength LII ratio processing |
| Brand | BCC |
|---|---|
| Origin | Hebei, China |
| Model | BKS-3000 |
| Instrument Type | Flue Gas CEMS |
| Accuracy | ≤±1% FS/24h |
| Repeatability | ≤±1% FS/24h |
| Response Time | ≤10 s |
| Stability (Zero/Scale Drift) | ≤±1% FS/24h (gaseous), negligible drift (particulate) |
| Measured Parameters | SO₂, NOₓ (NO, NO₂, N₂O), CO, CO₂, SO₃, CH₄, O₂, HCl, NH₃, HF, H₂S, H₂O, particulate matter (PM) |
| Detection Methods | Non-Dispersive Infrared (NDIR), Tunable Diode Laser Absorption Spectroscopy (TDLAS), UV Differential Optical Absorption Spectroscopy (UV-DOAS), Electrochemical (O₂), Optical Scattering (PM) |
| Output Interfaces | RS232, RS485, 4–20 mA, Ethernet, 4G/5G cellular |
| Brand | BCC |
|---|---|
| Origin | Hebei, China |
| Model | KPV-2000 |
| Instrument Type | Continuous Emission Monitoring System (CEMS) |
| Measurement Parameters | Temperature, Pressure, Velocity |
| Temperature Range | 0–500 °C (customizable up to 1100 °C) |
| Pressure Range | −8 to +8 kPa |
| Velocity Range | 5–40 m/s |
| Measurement Methods | Pt100 resistance thermometer (temperature), piezoresistive pressure transducer (pressure), Pitot tube differential pressure method (velocity) |
| Accuracy | ±2% relative error |
| Power Consumption | < 0.04 kVA |
| Output Signal | 4–20 mA analog |
| Environmental Rating | Rated for continuous operation at ambient housing temperatures up to 1100 °C |
| Additional Feature | Integrated automatic purge system |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3000UV |
| Measurement Principle | UV-Differential Optical Absorption Spectroscopy (UV-DOAS) for SO₂/NO/NO₂ |
| Measurement Range | SO₂/NO/NO₂: 0–100 mg/m³ |
| O₂ | 0–25% (selectable) |
| Accuracy | ±2% F.S. |
| Repeatability | ≤2% |
| Response Time (T90) | ≤30 s |
| Stability | ≤±2% F.S./24 h |
| Linearity Error | ≤±2% F.S. |
| Sample Requirements | Condensate-free, particulate filtration <1 µm |
| Operating Humidity | 5–85% RH |
| Ambient Pressure | 86–108 kPa |
| Communication | Dual RS-232/RS-485 ports, Modbus RTU protocol (customizable) |
| Power Supply | AC 220 V, 50 Hz |
| Max Power Consumption | 200 W |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Model | Gasboard-3000UV |
| Measurement Principle | UV-Differential Optical Absorption Spectroscopy (UV-DOAS) for SO₂, NO, NO₂ |
| Measurement Range | SO₂/NO/NO₂: 0–100 mg/m³ |
| O₂ | 0–25% (selectable) |
| Accuracy | ±2% F.S. |
| Repeatability | ≤2% |
| Response Time (T₉₀) | ≤30 s |
| Stability | ≤±2% F.S./24 h |
| Linearity Error | ≤±2% F.S. |
| Sample Requirements | Liquid-free, particulate filtered (<1 µm) |
| Operating Humidity | 5–85% RH |
| Ambient Pressure | 86–108 kPa |
| Communication | Dual RS-232/RS-485, Modbus RTU protocol (customizable) |
| Power Supply | AC 220 V, 50 Hz |
| Max Power Consumption | 200 W |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-2520 |
| Detection Gases | O₂, CO, CO₂, H₂S, CH₄, C₂H₂, HF |
| Measurement Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Response Time | <30 s |
| Accuracy | ±1–2% F.S. (gas-dependent) |
| Resolution | 1 ppm (O₂, CO, H₂S, etc.), 0.01% (CO₂), 0.1 ppm (HF) |
| Operating Temperature | −10 to 50 °C |
| Humidity Range | 0–98% RH (non-condensing) |
| Power Supply | 12 V ±10% |
| Output Interface | RS-232 / RS-485 |
| Constant-Temperature Control | 50 °C ±0.5 °C |
| Dimensions (L×W×H) | 278 × 90 × 70 mm |
| Weight | ~1.2 kg |
| Compliance | Designed for industrial emission monitoring per ISO 14064-1 and EN 15267-3 pre-certification requirements |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Gasboard-3000 |
| Instrument Type | Multi-Component Flue Gas Analyzer |
| Measurement Accuracy | SO₂, NO, CO: ±1 ppm |
| CO₂, O₂ | ±0.01% |
| Repeatability | ≤1% for SO₂, NO, CO, CO₂, O₂ |
| Response Time (T90) | <10 s (NDIR) |
| Stability | SO₂, NO, CO, CO₂: ≤±1% FS |
| O₂ | ≤±2% FS |
| Measured Gases | SO₂, NO, CO, CO₂, O₂ |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3000 |
| Measurement Principle | NDIR (SO₂/NO/CO/CO₂), Electrochemical (O₂) |
| Measurement Range | SO₂/NO: 0–2000 ppm |
| CO | 0–10000 ppm |
| CO₂/O₂ | 0–25% vol |
| Accuracy | SO₂/NO/CO/CO₂: ±1% FS |
| O₂ | ±2% FS |
| Resolution | SO₂/NO/CO: 1 ppm |
| CO₂/O₂ | 0.01% vol |
| Repeatability | ≤1% |
| Response Time (T₉₀) | <20 s (NDIR) |
| Zero Drift Stability | SO₂/NO/CO/CO₂: ≤±1% FS |
| O₂ | ≤±2% FS |
| Sample Flow Rate | 0.7–1.2 L/min |
| Inlet Pressure | 2–50 kPa |
| Sample Requirements | Dust-free, moisture-free, oil-free |
| Output Interfaces | RS-485, RS-232, 4–20 mA |
| Power Supply | AC 220 V, 50 Hz |
| Display | LCD with built-in diagnostics and auto-zero function using integrated air pump |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3000 |
| Measured Gases | SO₂, NO, CO, CO₂, O₂ |
| Measurement Principle | NDIR (SO₂/NO/CO/CO₂), Electrochemical Detection (O₂) |
| Range | SO₂/NO: 0–2000 ppm |
| CO | 0–10,000 ppm |
| CO₂/O₂ | 0–25% vol |
| Accuracy | SO₂/NO/CO/CO₂: ±1% FS |
| O₂ | ±2% FS |
| Resolution | SO₂/NO/CO: 1 ppm |
| CO₂/O₂ | 0.01% |
| Repeatability | ≤1% |
| Response Time (T90) | <10 s (NDIR) |
| Zero Drift Stability | SO₂/NO/CO/CO₂: ≤±1% FS |
| O₂ | ≤±2% FS |
| Sample Flow Rate | 0.7–1.2 L/min |
| Inlet Pressure | 2–50 kPa |
| Sample Requirements | Dust-free, moisture-free, oil-free |
| Output Interfaces | RS-485, RS-232, 4–20 mA |
| Power Supply | AC 220 V, 50 Hz |
| Display | LCD with self-diagnostic interface |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | Gasboard-3000 |
| Instrument Type | Multi-Gas Continuous Emission Monitoring (CEM) Analyzer |
| Measurement Accuracy | SO₂, NO, CO: ±1 ppm |
| CO₂, O₂ | ±0.01% |
| Repeatability | ≤1% for SO₂, NO, CO, CO₂, O₂ |
| Response Time | T₉₀ < 10 s (NDIR channels) |
| Stability | SO₂, NO, CO, CO₂: ≤±1% FS |
| O₂ | ≤±2% FS |
| Measured Gases | SO₂, NO, CO, CO₂, O₂ |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | Gasboard-3000GHG |
| Instrument Type | Multi-Gas Flue Gas Analyzer |
| Repeatability | ≤±1% FS |
| Response Time (T90) | <25 s |
| Measured Gases | CO₂, CH₄, N₂O, CO, O₂ |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3000P |
| Instrument Type | Portable Flue Gas Analyzer |
| Measured Gases | CO, CO₂, O₂, SO₂, NO, Flue Gas Temperature |
| Measurement Principle | NDIR (CO, CO₂), Electrochemical (O₂, SO₂, NO), K-type Thermocouple (Temperature) |
| Range | CO/NO: 0–2000 ppm |
| SO₂ | 0–5000 ppm |
| CO₂/O₂ | 0–25% vol |
| Accuracy | ±2% F.S. (all gases), ±3°C (temperature) |
| Repeatability | ≤2% |
| Response Time (T90) | <20 s (NDIR) |
| Resolution | SO₂/NO/CO: 1 ppm |
| CO₂/O₂ | 0.01% vol |
| Optimal Flow Rate | 0.7–1.2 L/min |
| Power | Rechargeable Li-ion battery, 12.6 V external charger |
| Communication | RS485 / RS232 |
| Features | Integrated temperature-compensated sampling probe, auto-diagnostic function, built-in imported sampling pump, data logging with query/delete capability |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3000P |
| Instrument Type | Portable Flue Gas Analyzer |
| Measurement Range | CO/NO: 0–2000 ppm |
| SO₂ | 0–5000 ppm |
| CO₂/O₂ | 0–25% vol |
| Accuracy | ±2% F.S. for CO/CO₂/SO₂/NO/O₂ |
| Repeatability | ≤2% |
| Response Time (T90) | <20 s (NDIR channels) |
| Detection Parameters | SO₂, NO, CO, CO₂, O₂, flue gas temperature |
| Measurement Principles | NDIR for CO/CO₂ |
| Resolution | 1 ppm for SO₂/NO/CO |
| Optimal Sampling Flow Rate | 0.7–1.2 L/min |
| Power Supply | Internal rechargeable Li-ion battery |
| Communication Interfaces | RS485, RS232 |