Flue Gas Analyzer
Filter
Showing 31–60 of 245 results
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3000Plus |
| Measurement Principle | Microflow NDIR (SO₂/NO/CO), NDIR (CO₂), Electrochemical Detection (O₂) |
| Measured Gases | SO₂, NO, CO, CO₂, O₂ |
| Range | SO₂/NO: 0–200 ppm |
| CO | 500–5000 ppm |
| CO₂/O₂ | 0–25% vol |
| Accuracy | ±2% FS |
| Repeatability | <2% |
| Response Time (T90) | <25 s (NDIR) |
| Resolution | SO₂/NO: 1 ppm |
| CO | 1 ppm |
| CO₂/O₂ | 0.01% |
| Zero Drift Stability | ±2% over 7 days |
| Flow Rate | 0.7–1.2 L/min |
| Output | RS-485 / RS-232 / 4–20 mA |
| Power | 100–240 VAC, 150 W |
| Auto-Zero Function | Integrated air pump with programmable zero calibration |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3000UV |
| Measurement Principle | UV-DOAS (SO₂, NO, NO₂) |
| Measured Gases | SO₂, NO, NO₂, O₂ |
| Range | SO₂/NO/NO₂: 0–100 mg/m³ |
| O₂ | 0–25% (selectable) |
| Accuracy | ±2% F.S. |
| Repeatability | ≤2% |
| Response Time (T₉₀) | ≤30 s |
| Stability | ≤±2% F.S./24 h |
| Linearity Error | ≤±2% F.S. |
| Sample Requirements | Liquid-free, particulate filtration <1 µm |
| Operating Humidity | 5–85% RH |
| Ambient Pressure | 86–108 kPa |
| Power Supply | AC 220 V, 50 Hz |
| Max Power Consumption | 200 W |
| Communication | Dual RS-232/RS-485, Modbus RTU or customizable protocol |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3000UV |
| Measurement Principle | UV-DOAS (SO₂/NO/NO₂), Electrochemical (O₂) |
| Measurands | SO₂, NO, NO₂, O₂ |
| Range | SO₂/NO/NO₂: 0–100 mg/m³ |
| O₂ | 0–25% (selectable) |
| Accuracy | ±2% F.S. |
| Repeatability | ≤2% |
| Response Time (T90) | ≤30 s |
| Stability | ≤±2% F.S./24 h |
| Linearity Error | ≤±2% F.S. |
| Sample Requirements | Condensate-free, particulate filtration <1 µm |
| Operating Humidity | 5–85% RH |
| Ambient Pressure | 86–108 kPa |
| Communication | RS-232/RS-485 (Modbus RTU or customizable) |
| Power Supply | AC 220 V, 50 Hz |
| Max. Power Consumption | 200 W |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3006UV |
| Measurement Principle | UV DOAS |
| Measured Gases | SO₂, NO, NO₂, O₂ |
| Accuracy | ≤±1% F.S. |
| Repeatability | ≤1% |
| Response Time | T₉₀ ≤30 s at 1 L/min |
| Stability | ≤±1.5% F.S./24 h |
| Linear Error | ≤±1% F.S. |
| Sample Flow Rate | 0.7–1.2 L/min |
| Display | 7-inch color TFT touchscreen (800×480) |
| Dimensions (W×H×D) | 438×173×350 mm |
| Power Supply | 100–240 VAC, 100 W |
| Communication | Dual RS232/RS485, 4–20 mA analog output |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3050-D |
| Measurement Principle | Ceramic Zirconia Electrolyte (O₂), Derived H₂O Calculation via O₂/H₂O Correlation |
| H₂O Range | 0–40 %v/v |
| O₂ Range | 0.1–25 %v/v |
| Accuracy | ±2 %F.S. (H₂O & O₂) |
| Repeatability | ±2 % |
| Sample Temp. Limit | ≤ 180 °C |
| Output | Dual 4–20 mA, RS485 (standard), RS232 (optional), 3 x Relay Outputs |
| Power | 24 V DC, 50 W |
| Installation | Wall-mounted probe + DIN-rail instrument housing |
| Enclosure | Non-explosion-proof |
| Operating Ambient | −10 to +50 °C, <90 %RH |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Gasboard-3055 |
| Instrument Type | In-Situ Flue Gas Oxygen Analyzer |
| Measurement Range | 0–25% O₂ |
| Resolution | 0.1% O₂ |
| Accuracy | ±2% F.S. |
| Repeatability | ≤±1% F.S. |
| Response Time (T90) | <15 s |
| Stability | ±2% F.S. / 7 days |
| Operating Temperature (Flue Gas) | 0–700 °C |
| Probe Length Options | 500 / 1000 / 1500 mm (customizable) |
| Sampling Method | Flow-guided direct insertion |
| Installation | DN40 flange mount |
| Enclosure Rating | IP65 |
| Display | 128×160 color LCD |
| Output Signals | RS-485 & 4–20 mA |
| Relay Outputs | 2 channels |
| Power Supply | DC 24 V ±10%, 2 A |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Gasboard-3055 |
| Instrument Type | In-situ Flue Gas Oxygen Analyzer |
| Repeatability | ≤±1% FS |
| Response Time | T90 < 15 s |
| Stability | ±2% FS / 7 days |
| Measured Gas | O₂ |
| Measurement Range | 0–25% vol |
| Resolution | 0.1% vol |
| Accuracy | ±2% FS |
| Sampling Method | Direct-insertion, flow-guided probe |
| Operating Temperature | 0–700 °C |
| Enclosure Rating | IP65 |
| Output Signals | RS-485 & 4–20 mA |
| Power Supply | DC 24 V ±10%, 2 A |
| Probe Length Options | 500 / 1000 / 1500 mm (customizable) |
| Display | 128×160 color LCD |
| Alarm Outputs | 2 relay channels |
| Calibration | Field-calibratable with ambient air or certified O₂ standard gas |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3100 |
| Measurement Principle | NDIR (CO/CO₂/CH₄/C₂H₂/C₂H₄/CnHm), TCD (H₂), ECD (O₂) |
| Measurement Range | CO/CO₂/CH₄/H₂: (0–100)%, O₂: (0–25)%, C₂H₂/C₂H₄/CnHm: (0–10)% (optional) |
| Accuracy | ±1% FS (CO/CO₂/CH₄/C₂H₂/C₂H₄/CnHm), ±2% FS (O₂/H₂) |
| Repeatability | ≤1% |
| Response Time (T90) | <15 s (NDIR) |
| Flow Rate | 0.7–1.2 L/min |
| Inlet Pressure | 2–50 kPa |
| Resolution | 0.01% |
| Output | RS-485/RS-232, 4–20 mA |
| Power Supply | 100–240 VAC, 100 W |
| Display | LCD |
| Thermal Value Units | kcal/m³ & MJ/m³ (switchable) |
| Auto-Zero | Built-in air pump |
| Diagnostics | Real-time sensor health monitoring |
| Sample Requirements | Dust-free, moisture-free, oil-free gas |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Gasboard-3201Plus |
| Instrument Type | Portable Flue Gas Analyzer |
| Measurement Accuracy | ±0.2% FS (O₂, CO₂) |
| Response Time | T₉₀ < 30 s (O₂, SO₂, CO₂), T₉₀ < 40 s (CO, NO), T₆₀ < 30 s (SO₂) |
| Measured Gases | O₂, CO, NO, SO₂, CO₂ |
| Gas Detection Principle | Electrochemical (O₂, CO, NO, SO₂), NDIR (CO₂) |
| Operating Temperature | –5 °C to +45 °C |
| Display | 5.5-inch HD touchscreen (720 × 1280 px) |
| Battery | Rechargeable Li-ion, 3.7 V / 6400 mAh |
| Data Storage | Internal memory for 2000 measurement sets |
| Connectivity | Bluetooth 5.0 for mobile app and wireless printer |
| Compliance | Designed to support EPA Method 6C, ISO 12039, EN 15267-3, and GLP-compliant data logging with timestamped audit trail |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3400P |
| Measurement Principle | NDIR for CO/CO₂ |
| Measured Parameters | CO (0–5000 ppm), CO₂ (0–25 % vol), O₂ (0–21 % vol), flue gas temperature (0–1200 °C) |
| Accuracy | CO/CO₂: ±1% FS |
| O₂ | ±2% FS |
| temperature | ±3 °C or ±1% of reading |
| Repeatability | ≤1% |
| Response Time (T90) | ≤15 s (NDIR) |
| Resolution | O₂: 0.01% vol |
| CO | 1 ppm |
| CO₂ | 0.01% vol |
| temperature | 0.1 °C |
| Operating Temperature | 0–50 °C |
| Relative Humidity | 5–85% RH |
| Battery Life | >10 h (rechargeable Li-ion) |
| Communication | RS-232 / RS-485 |
| Expandable Sensors | SO₂, NO, NO₂ |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3600UV |
| Measurement Principle | UV-DOAS |
| Measured Gases | SO₂, NO, NO₂ |
| Range | 0–500 mg/m³ (each) |
| Accuracy | ≤±2% F.S. |
| Repeatability | ≤1% |
| Response Time | ≤30 sec @ T90 |
| Detection Limit | 0.01 mg/m³ (SO₂/NO/NO₂) |
| Sample Method | Hot-Wet Extraction |
| Optical Path | Multi-reflection long-path cell |
| Light Source | Pulsed Xenon Lamp |
| Measurement Chamber Temp. | 120–190 °C (adjustable) |
| Zero Drift | ≤2% F.S./24 h |
| Span Drift | ≤2% F.S./24 h |
| Communication | RS-232 / RS-485 |
| Power Supply | 220 VAC / 50 Hz |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3800P |
| Instrument Type | Portable Flue Gas Analyzer |
| Measurement Accuracy | ±2% F.S. (SO₂, NO, CO, CO₂, O₂) |
| Repeatability | ≤2% |
| Response Time | T₉₀ < 15 s (NDIR) |
| Measured Gases | SO₂, NO, CO, CO₂, O₂ |
| Detection Principle | NDIR (SO₂/NO/CO/CO₂), Electrochemical (O₂) |
| Temperature Range | 0–800 °C |
| Flow Velocity Range | 3–40 m/s |
| Sample Flow Rate | 0.7–1.2 L/min |
| Inlet Pressure | 2–50 kPa |
| Power Supply | 100–240 VAC, 150 W |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3800Plus |
| Instrument Type | Portable Flue Gas Analyzer |
| Measurement Accuracy | ≤2% F.S. |
| Repeatability | ≤2% |
| Response Time | ≤30 s |
| Stability | ≤2% F.S./24 h |
| Measured Gases | SO₂, NO, CO, CO₂, O₂ |
| Measurement Principles | Micro-flow NDIR (SO₂/NO/CO), Broadband NDIR (CO₂), Electrochemical Detection (O₂) |
| Sample Flow Rate | 0.7–1.2 L/min |
| Dimensions | 275 × 470 × 175 mm |
| Weight | 7.5 kg |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Display | LCD |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-3800UV |
| Instrument Type | Portable Flue Gas Analyzer |
| Measurement Accuracy | ±2% F.S. |
| Repeatability | ≤2% |
| Response Time | T90 < 15 s |
| Stability | ≤2% F.S./24 h |
| Measured Gases | SO₂, NO, CO, CO₂, O₂ |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | Gasboard-9050 |
| Instrument Type | Continuous Emission Monitoring System (CEMS) |
| Response Time | T90 < 60 s (NDIR) |
| Measured Gases | SO₂, NO, CO, CO₂, O₂ |
| Measurement Principle | NDIR for SO₂/NO/CO/CO₂ |
| Range | SO₂/NO: 0–200 ppm |
| CO/CO₂/O₂ | 0–25 % vol |
| Accuracy | ±2 % FS |
| Resolution | SO₂/NO/CO/CO₂: 1 ppm |
| O₂ | 0.01 % vol |
| Repeatability | ±2 % FS |
| Operating Temperature Influence | ±5 % FS (5–35 °C) |
| Interference Gas Effect | ±5 % FS |
| Power Supply Variation Effect | ±2 % FS (±10 % AC voltage) |
| Optimal Sample Flow Rate | 0.7–1.2 L/min |
| Inlet Pressure Range | 2–50 kPa |
| Electrical Interface | RS-485 / RS-232 / 4–20 mA analog output |
| Power Supply | AC 220 V, 50 Hz |
| Built-in Features | Auto-diagnostic function, air zero calibration pump, automatic sampling, purging, and calibration sequences |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-9050GHG |
| Measurement Principle | NDIR (CH₄/CO₂/CO/N₂O), Electrochemical (O₂) |
| Measurands | CH₄, CO₂, CO, N₂O, O₂ |
| Accuracy | ≤±1% F.S. (CH₄/CO₂/CO/N₂O), ≤±2% F.S. (O₂) |
| Repeatability | ≤±1% F.S. |
| Response Time (T90) | <25 s |
| Detection Limits | CH₄/CO/N₂O: 0–1000 ppm |
| CO₂/O₂ | 0–25% vol |
| Resolution | CH₄/CO/N₂O: 1 ppm |
| CO₂/O₂ | 0.01% vol |
| Flue Gas Temp. Range | 0–300 °C |
| Heated Line & Probe Temp. | 120–180 °C |
| Protection Rating | IP54 |
| Dimensions (L×W×H) | 800 × 760 × 1800 mm |
| Ambient Temp. | −20 to +50 °C |
| Humidity | <95% RH (non-condensing) |
| Power Supply | 220 V AC ±10%, >3000 W |
| Compressed Air Requirement | 0.4–0.8 MPa, oil-free, dust-free, moisture-free |
| Max. Air Consumption | 2.2 m³/h |
| Avg. | 0.45 m³/h |
| Max. Sample Flow | 2 L/min |
| Avg. | 1.5 L/min |
| Communication Interfaces | RS-485, RS-232, 4–20 mA, Ethernet |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-9070 |
| Measurement Principle | UV-DOAS |
| Measured Gases | SO₂, NO, NH₃ |
| Measurement Range (SO₂) | 0–1000 mg/m³ (desulfurization inlet), 0–50 mg/m³ (emission stack) |
| Measurement Range (NO) | 0–100 mg/m³ (inlet), 0–50 mg/m³ (emission) |
| Measurement Range (NH₃) | 0–20 mg/m³ (both inlet & outlet) |
| Accuracy | ≤ ±2% F.S. |
| Repeatability | ≤ 1% |
| Response Time (T₉₀) | ≤ 60 s |
| Resolution | 0.1 ppm |
| Operating Ambient Temperature | 0–50 °C |
| Power Supply | 220 V AC, 800 W |
| Purge Air Pressure | 0.4–0.8 MPa |
| Analog Outputs | 4 × 4–20 mA |
| Digital Outputs | 8 × relay |
| Communication Interfaces | RS485, RS232 |
| Origin | Switzerland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CLD 60 Series |
| Pricing | Available Upon Request |
| Brand | ecom |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | ecom-AK |
| Instrument Type | Dedicated Burner Control Unit Diagnostic Analyzer |
| Detectable Units | Automatic identification and diagnostics of common burner management systems (e.g., Siemens Desigo, Honeywell UDC, SAACKE SAB, Weishaupt W-FM, Danfoss VLT, etc.) |
| Communication Interfaces | USB data cable (for PC connection), Bluetooth 4.0 (for wireless transmission to ecom-J2KNpro control panel), RS232 (for integration with ecom-EN3 and ecom-D analyzers) |
| Display | Integrated monochrome LCD (128 × 64 pixels), backlight enabled |
| Data Logging | Internal memory stores up to 1,000 diagnostic events with timestamps |
| Physical Dimensions (W × H × D) | 88 × 41 × 32 mm |
| Weight | 322 g |
| Operating Temperature Range | 0 °C to +50 °C |
| IP Rating | IP42 |
| Power Supply | Rechargeable Li-ion battery (7.4 V, 1,200 mAh), runtime ≥ 12 h continuous operation |
| Compliance | CE marked, RoHS compliant, EMC Directive 2014/30/EU, EN 61326-1:2013 |
| Brand | Ecom (Czech Republic) |
|---|---|
| Origin | Germany |
| Model | ecom-CL2 |
| Instrument Type | Portable Flue Gas Analyzer |
| Standard Sensors | O₂ (electrochemical, long-life), CO (electrochemical, long-life, overload-protected) |
| Built-in Thermal Printer | Yes |
| Condensate Monitoring | Electronic cold trap detection |
| Housing | Anodized aluminum, wall-mountable & desktop-ready |
| Dimensions (closed) | 340 × 230 × 95 mm |
| Dimensions (open) | 340 × 350 × 180 mm |
| Weight | ~3.0 kg (complete system, no accessories) |
| Optional Sensors/Modules | NO (electrochemical), differential pressure probe, low-power Bluetooth module, ambient temperature sensor (with cable), manual soot sampling kit, 260 mm ambient temperature probe, dedicated sampling probe |
| Brand | Ecom |
|---|---|
| Origin | Germany |
| Model | ecom-B |
| Instrument Type | Portable Flue Gas Analyzer |
| Sensor Options | O₂, CO, NO (up to 3 electrochemical sensors) |
| Dimensions (unit only) | 200 × 125 × 70 mm |
| Dimensions (with carrying case) | 250 × 180 × 80 mm |
| Weight (unit only) | ~1.5 kg |
| Weight (with case) | ~2.0 kg |
| Housing | Anodized aluminum alloy |
| Power | Rechargeable Li-ion battery (long-life) |
| CO Sensor | Overload protection integrated |
| Accessories | Magnetic-coupled carrying case with rear-mounted neodymium magnets |
| Brand | Ecom (Czech Republic) |
|---|---|
| Origin | Germany |
| Model | ecom-D |
| Instrument Type | Portable Flue Gas Analyzer |
| Dimensions | ~220 × 125 × 85 mm |
| Weight | ~2 kg (including sampling system) |
| Housing | Anodized aluminum with integrated permanent magnet |
| Power | Rechargeable high-capacity battery |
| Display & Interface | Backlit LCD screen and tactile keypad |
| Connectivity | Integrated Bluetooth |
| Calibration | Automatic zero calibration on startup |
| CO Sensor Overload Protection | Yes, maintains continuity of other gas measurements |
| Standard Sampling System | Includes probe, fixed cone, and gas tubing |
| Optional Sensors (up to 6 total) | CH₄ (NDIR, 0–100%), H₂S (electrochemical, 0–1000 ppm or 0–5000 ppm), NOₓ (with 3.5 m or 5 m heated tube), O₂ (paramagnetic or electrochemical, reference O₂ adjustable down to 5%), temperature sensors (contact, surface, differential), pressure compensation, condensate level monitoring, Peltier gas cooler, ambient temperature sensor |
| Units | ppm, mg/m³, mg/kWh, % vol |
| Gas Pipeline Pressure Compensation | Automatic |
| Temperature Measurement Range | Configurable per probe type (e.g., flue exit vs. return flow) |
| Sampling Probe Options | 250–1500 mm standard |
| Brand | Ecom (Czech Republic) |
|---|---|
| Origin | Germany |
| Model | ecom-EN3 |
| Instrument Type | Portable Flue Gas Analyzer |
| Gas Sensors (up to 6) | O₂, CO, NO, NO₂, SO₂, CO₂ (NDIR) or CH₄ (NDIR), H₂S (electrochemical, 0–1000 ppm or 0–5000 ppm) |
| Temperature Measurement | Flue gas & ambient |
| Data Units | ppm, mg/m³, mg/kWh |
| Pump Flow Rate | up to 1.7 L/min |
| Dimensions | ~400 × 275 × 205 mm |
| Weight | ~7 kg (including probe assembly) |
| Optional Features | Peltier cooler with condensate detection, integrated 58 mm thermal printer, Bluetooth, SD card logging, iOS/Android app, automatic smoke opacity (DIN 51418-2), differential pressure flow measurement, auto-calibration, particulate filters for solid fuels |
| Compliance | Designed for EN 15267, EN 14181, VDI 3862, and applicable EU emission monitoring directives |
| Brand | ECOM (Czech Republic) |
|---|---|
| Origin | Germany |
| Model | ECOM-LSG |
| Instrument Type | Portable Gas Leak Detector |
| Detection Target | Methane (CH₄) |
| Measurement Range | 0–0.5% vol CH₄ |
| Response Time | <2 s |
| Operating Temperature | –5 °C to +40 °C |
| Sensor | Electrochemical or catalytic bead (field-replaceable) with temperature compensation |
| Display | 20×7 mm backlit LCD |
| Audio Alert | Configurable (on/off/headphone output) |
| Power Supply | 2×AAA batteries (standard or rechargeable kit optional) |
| Dimensions (W×H×D) | 155×35×22 mm |
| Probe | Flexible, 355 mm length |
| Weight | ~200 g |
| Accessories (Optional) | Rechargeable battery kit (batteries + charger), carrying case, headphone |
| Brand | Ecom (Czech Republic) |
|---|---|
| Origin | Germany |
| Model | EN3Tech |
| Type | Portable Flue Gas Analyzer |
| Detection Method | UV Absorption Spectroscopy + Electrochemical Sensors |
| Measured Gases | NO, NO₂, NOₓ, SO₂, CO |
| Compliance | CE, RoHS, EN 15267-3 (for portable emission monitoring systems), ISO 12039, ISO 10849, EPA Method 6C (UV for SO₂), EPA Method 7E (UV for NOₓ) |
| Operating Temperature Range | –10 °C to +50 °C |
| Sample Flow Rate | Adjustable up to 1.2 L/min |
| Dew Point Control | Peltier-cooled condenser with automatic condensate removal |
| Display | Backlit color graphical LCD with tactile keypad |
| Data Output | Integrated thermal printer + microSD card logging (up to 32 GB) |
| Optional Heated Sampling System | Up to 10 m heated line (0–500 °C), probe lengths 300–1500 mm, 3-channel anti-adsorption NOₓ line (2.7 m, PTFE-lined, 0–1100 °C thermocouple) |
| Origin | Austria |
|---|---|
| Type | Portable Flue Gas Analyzer |
| Model | GA-21plus |
| Measurement Accuracy | ≤±5% FS |
| Repeatability | ≤2% |
| Response Time | ≤90 s |
| Stability | ≤5% over 8 h |
| Power Supply | Rechargeable battery (4 h operation) or AC adapter |
| Communication Interface | RS232C |
| Data Storage | Internal memory for 1024 measurement records (10 databases), plus 30 printable reports |
| Display | Backlit graphical LCD with real-time multi-parameter visualization |
| Printer | Integrated 57 mm thermal dot-matrix printer |
| Brand | ecom (Czech Republic) |
|---|---|
| Origin | Germany |
| Model | J2KNpro |
| Instrument Type | Portable Flue Gas Analyzer |
| Sensor Capacity | Up to 9 sensors |
| Measurable Gas Components | Up to 11 |
| Detection Technologies | Electrochemical (EC), Non-Dispersive Infrared (NDIR), Ultraviolet (UV), Chemiluminescence Detection (CLD), Photoacoustic Spectroscopy (PAS), and Paramagnetic Oxygen (PEL) |
| Dimensions (Main Unit) | 510 × 330 × 250 mm |
| Dimensions (with Heated Sampling System) | 510 × 650 × 250 mm |
| Weight (Main Unit) | ~14 kg |
| Weight (with Heated Sampling System) | ~23 kg |
| Operating Ambient Temperature Range | 0–40 °C (auto-heating/cooling) |
| Condensation Management | Dual-stage Peltier cooler with electronic condensate level monitoring and automatic drainage |
| Gas Flow Rate | Up to 2.6 L/min (digital flow display) |
| CO Auto-Cut-off & Purge Function | Yes |
| Pre-Shutdown Fresh Air Purge | Yes |
| Intermittent Measurement Mode | Programmable (up to multi-day duration) |
| Data Output Units | ppm, mg/m³, mg/kWh, % vol |
| Pressure Compensation | Automatic |
| Calibration | Onboard one-touch calibration (full-system calibration performed in climate-controlled chamber) |
| Integrated Thermal Printer | Yes |
| Connectivity Options | Wi-Fi, Bluetooth, Ethernet, Radio Remote Control (868.135 MHz, CMIIT ID: 2011DJ0261 / 2011DJ0262) |
| Software | Free PC software + iOS/Android apps |
| Compliance | Designed for EN 15267, EN 14181, ISO 12039, ISO 10849, EPA Method 6C, EPA Method 7E, and applicable EU emission monitoring directives |
| Key | Brand: ECOM (Czech Republic) |
|---|---|
| Origin | Germany (assembled/quality-controlled) |
| Model | ecom-UNO / ecom-DP |
| Type | Portable differential pressure meters for flue gas and combustion system diagnostics |
| Measurement Range (ecom-UNO) | ±200 hPa |
| Resolution (ecom-UNO) | 0.01 hPa |
| Accuracy (ecom-UNO) | ±1% of reading |
| Overload Limit (ecom-UNO) | 300 hPa |
| Measurement Ranges (ecom-DP) | 0–7 kPa (high-res mode), 0–150 kPa (broad-range mode) |
| Resolution (ecom-DP) | 0.01 kPa (at ≤7 kPa), 0.1 kPa (at ≤150 kPa) |
| Accuracy (ecom-DP) | ±3% of reading |
| Power Supply | 2× AA 1.5 V (ecom-UNO), 3× AA 1.5 V (ecom-DP) |
| Dimensions (ecom-UNO) | 106 × 64 × 28 mm |
| Weight (ecom-UNO, incl. batteries) | ~150 g |
| Dimensions (ecom-DP) | 170 × 75 × 35 mm |
| Weight (ecom-DP, incl. batteries) | ~300 g |
| Display | Backlit graphical LCD (ecom-DP only) |
| Units | hPa, mmH₂O, PSI, mmHg (ecom-UNO) |
| Additional Functions | Min/Max hold, data hold, adjustable damping, programmable test routines (e.g., TRGI-compliant tightness testing), on-board logging (ecom-DP), PC software support (ecom-DP Logger) |
| Brand | Ecom (Czech Republic) |
|---|---|
| Origin | Germany |
| Model | ecom-ST (CEMS) |
| Instrument Type | Portable Flue Gas Analyzer |
| Measurement Range | O₂, CO (H₂-compensated), optional CO₂, THC (IR), NO/NO₂, SO₂ |
| Sampling Flow Rate | 2.6 L/min |
| Cooling | Peltier-based gas cooler with condensate level sensing and automatic drainage |
| Communication | Modbus RTU, RS458 |
| Power Supply | 100–240 VAC |
| Enclosure Rating | IP52 (customizable to higher ingress protection) |
| Mounting | Wall-mounted |
| Calibration | 100% sensor calibration performed in controlled environmental chamber |
| Compliance | CE-marked |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | ET5101 |
| Price Range | USD 7,000–14,000 |
| Instrument Type | Continuous Emission Monitoring System (CEMS) Compliant Portable Analyzer |
| Indication Error | ±0.2% FS |
| Repeatability | <2% RSD |
| Response Time | ≤15 s (T90) |
| Stability | <5% drift over 8 h |
| Measured Parameters | Particulate Matter (PM) concentration via gravimetric filtration + Flue Gas composition (O₂, SO₂, NO, NO₂, CO, CO₂) |