| Brand | Aerodyne |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Type | Online Analytical System |
| Measurement Principle | Tunable Infrared Laser Direct Absorption Spectroscopy (TILDAS) |
| Response Time | 1 s (10 Hz acquisition rate) |
| Repeatability | ±0.2‰ for δ¹³C(CH₄), ±1.5‰ for δ¹⁴N¹⁵N¹⁶O, ±0.03 ppb for N₂O (100 s avg), ±0.05 ppb for CH₄ (100 s avg), ±0.03 ppm for CO₂ (100 s avg), ±0.03‰ for δ¹⁸O(CO₂), ±0.03‰ for δ¹⁸O(H₂O), ±0.1‰ for δHDO (100 s avg) |
| Measured Species & Isotopologues | CH₄, δ¹³C(CH₄), N₂O, δ¹⁵N¹⁴N¹⁶O, δ¹⁴N¹⁵N¹⁶O, δ¹⁴N¹⁴N¹⁸O, CO₂, δ¹³C(CO₂), δ¹⁸O(CO₂), H₂O, δ¹⁸O(H₂O), δHDO |
| Brand | Aerodyne |
|---|---|
| Origin | USA |
| Model | Aerodyne TILDAS Series (Configurable Dual-Laser Platform) |
| Principle | Mid-Infrared Tunable Diode Laser Direct Absorption Spectroscopy (TILDAS) |
| Type | Continuous Online Analyzer |
| Response Time | ≤1 s (10 Hz measurement capability) |
| Detection Limits | Sub-ppt (1σ, 1 s) for CO, CO₂, CH₄, C₂H₄, HCHO, CHOOH, COS, SO₂, NO, N₂O, NO₂, NH₃, HONO, HNO₃, HOD, ¹³C-CO₂, ¹⁸O-CO₂, ¹⁷O-CO₂, ¹⁵N¹⁴N¹⁶O (δ¹⁵Nα), ¹⁴N¹⁵N¹⁶O (δ¹⁵Nβ) |
| Optical Path Length | 76 m or 210 m (Astigmatic Multipass Cell) |
| Multi-Platform Deployment | Fixed-site, eddy covariance towers, automated soil flux chambers, mobile platforms (vehicle, aircraft, marine vessel) |
| Brand | Aerodyne |
|---|---|
| Origin | USA |
| Model | Aerodyne TILDAS-CNW |
| Detection Principle | Tunable Infrared Laser Direct Absorption Spectroscopy (TILDAS) |
| Configuration | Online Continuous Analyzer |
| Response Time | <1 s (up to 10 Hz measurement frequency) |
| Repeatability | CH₄, δ¹³C(CH₄), N₂O, δ¹⁵N¹⁴N¹⁶O, δ¹⁴N¹⁵N¹⁶O, δ¹⁸O(N₂O), CO₂, δ¹³C(CO₂), δ¹⁸O(CO₂), H₂O, δ¹⁸O(H₂O), δHDO |
| Measurement Range | CH₄: 2–20 ppm |
| N₂O | 0.3–100 ppm |
| CO₂ | 300–1000 ppm or 0.1–0.3 µmol/mol |
| H₂O | 0–4% |
| Precision (1 s / 100 s) | CH₄: 0.2 / 0.05 ppb |
| δ¹³C(CH₄) | 1.0 / 0.2 ‰ |
| N₂O | 0.03 / 0.01 ppb |
| δ¹⁴N¹⁵N¹⁶O | 6.0 / 1.5 ‰ |
| δ¹⁵N¹⁴N¹⁶O | 9.0 / 2.3 ‰ |
| δ¹⁸O(N₂O) | 12.0 / 3.0 ‰ |
| CO₂ | 0.1 / 0.03 ppm |
| δ¹³C(CO₂) | 0.1 / 0.03 ‰ |
| δ¹⁸O(CO₂) | 0.1 / 0.03 ‰ |
| H₂O | 10 / 5 ppm |
| δ¹⁸O(H₂O) | 0.1 / 0.03 ‰ |
| δHDO | 0.3 / 0.1 ‰ |
| Operating Temperature | 10–35 °C |
| Humidity Range | 5–95 % RH (non-condensing) |
| Sampling Flow Rate | 0–20 SLPM |
| Data Interfaces | RS232, USB, Ethernet |
| Dimensions | 530 × 660 × 710 mm (W×D×H) |
| Weight | 72 kg |
| Power | 500 W, 120/240 VAC, 50/60 Hz |
| Brand | Aerodyne |
|---|---|
| Origin | USA |
| Model | TILDAS-CO2/CH4/N2O |
| Detection Principle | Tunable Infrared Laser Direct Absorption Spectroscopy (TILDAS) |
| Configuration | Online, Closed-Path |
| Response Time | ≤1 s (selectable 1–10 Hz) |
| Precision (1 s) | CO₂: 100 ppb, CH₄: 0.1 ppb, N₂O: 0.03 ppb, H₂O: 10 ppm, δ¹³C-CO₂: 0.1‰, δ¹⁸O-CO₂: 0.03‰ |
| Measurement Range | CO₂: 0–5000 ppm, CH₄/N₂O: 0–10 000 ppb, H₂O: 0–5000 ppm, δ¹³C/δ¹⁸O: ±0.5‰ |
| Effective Optical Path Length | 210 m (Astigmatic Multipass Cell) |
| Detection Limit | Sub-ppt for key trace gases |
| Compliance | Designed for GLP/GMP-aligned operation |
| Brand | AeroNose |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Portable |
| Measurement Range | 0.1 ppb – 100 ppm |
| Detection Limit | ±1% of reading @ 100 ppb – 100 ppm |
| Response Time | 40 sec @ 500 ppb |
| Zero Drift Compensation | Automatic dual-channel switching |
| Resolution | 1% of Full Scale (F.S.) |
| Analog Output Options | 4–20 mA / 0–1 VDC / 1–5 VDC (selectable) |
| Data Update Interval | 0.1 sec – 25,500 min (configurable) |
| Sampling Flow Rate | 1.0–1.5 L/min (integrated pump) |
| Operating Temperature | 0–40 °C |
| Power Supply | DC 12 V, 1.5 A max. |
| Weight | 1.5 kg (including ozone scrubber and particulate filter) |
| Communication Interface | USB (for real-time temperature, pressure, and concentration logging) |
| Alarm Outputs | LED indicators for particle filter status, light source health, ozone scrubber saturation, and calibration due date |
| Brand | AeroNose |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HT8500 |
| Detection Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) with Quantum Cascade Laser (QCL) |
| Target Gas | Nitrous Oxide (N₂O) |
| Measurement Range | 0–5000 ppb |
| Precision | <0.5 ppb (@ 0.1 s integration time, @ 330 ppb, under standard temperature and pressure) |
| Optical Path | Open-path, non-contact |
| Compliance | Designed for field-deployable environmental monitoring per ISO 14064-1, EPA Method TO-15 (principle alignment), and EU Directive 2008/50/EC ambient air quality assessment frameworks |
| Brand | AeroNose |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | HT8600 |
| Pricing | Available upon Request |
| Measurement Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Target Gas & Range | CH₄: 0–15,000 ppb |
| Precision | <5 ppb (@0.1 s integration time, 2000 ppb CH₄, standard temperature & pressure) |
| Response Time (T₉₀) | <15 s |
| Detection Method | Real-time spectral absorption peak integration for trace gas concentration retrieval |
| Application Domain | Environmental monitoring, agricultural emissions assessment, industrial fugitive emission control |
| Brand | AeroNose |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | HT8600P |
| Measurement Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Detection Gases & Ranges | CH₄: 0–15,000 ppb |
| H₂O | 0–30,000 ppm |
| Precision | CH₄: ±5 ppb (@0.1 s averaging, 2000 ppb reference, STP conditions) |
| H₂O | ±20 ppm (@0.1 s averaging, 10,000 ppm reference, STP conditions) |
| Response Time | <15 s |
| Data Integration Method | Real-time spectral absorption peak integration for trace gas concentration retrieval |
| Brand | AeroNose |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | HT8700 |
| Instrument Type | Online Continuous Monitor |
| Technology | Quantum Cascade Laser Absorption Spectroscopy (QCLAS) |
| Optical Path | Open-Path, Non-Contact |
| Deployment | Field-Deployable, Grid-Independent, Mobile-Platform Compatible |
| Compliance | Designed for EPA Method Complementarity, ISO 14644-1 Cleanroom Ambient Monitoring Support, GLP-Traceable Data Logging |
| Brand | AeroNose |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | HT8800 Series |
| Price | USD 280,000 (FOB) |
| Measurement Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) in Mid-Infrared Region |
| Target Gases | CO₂, CH₄, N₂O, H₂O |
| Detection Limits | CO₂: ±0.5 ppm (at 400 ppm) |
| CH₄ | ±3 ppb (at 2 ppm), ±0.5 ppb for HT8840 variant |
| N₂O | ±0.5 ppb (at 330 ppb), ±0.7 ppb for HT8820 variant |
| H₂O | ±10 ppm (at 10,000 ppm) |
| Measurement Ranges | CO₂: 0–5000 ppm |
| CH₄ | 0–15 ppm |
| N₂O | 0–6 ppm |
| H₂O | 0–30,000 ppm |
| Response Time (T₉₀) | ≤30 s |
| Operating Temperature | −10 °C to +45 °C |
| Storage Temperature | −25 °C to +50 °C |
| Relative Humidity | <95% RH, non-condensing |
| Atmospheric Pressure Range | 70–110 kPa |
| Dimensions | 50 cm × 36 cm × 18 cm |
| Weight | <15 kg |
| Power Supply | 12 VDC / 10 A |
| Steady-State Power Consumption | <70 W |
| Data Storage | Integrated SD card or external data logger |
| Interface | RS232 serial port |
| Software Platform | Windows-based configuration and analysis suite |
| Brand | AeroNose |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HT8810 |
| Price | USD 140,000 (approx.) |
| Measurement Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) in Mid-Infrared Region |
| Target Gases | CO₂, H₂O |
| CO₂ Range | 0–5000 ppm |
| H₂O Range | 0–30000 ppm |
| CO₂ Accuracy | ±0.5 ppm @ 400 ppm |
| H₂O Accuracy | ±10 ppm @ 10000 ppm |
| Response Time (T₉₀) | <15 s |
| Operating Temperature | −10 °C to +45 °C |
| Storage Temperature | −25 °C to +50 °C |
| Relative Humidity | <95% RH, non-condensing |
| Atmospheric Pressure | 70–110 kPa |
| Dimensions | 50 cm × 36 cm × 18 cm |
| Weight | <15 kg |
| Power Supply | 12 VDC / 10 A |
| Steady-State Power Consumption | <70 W |
| Data Storage | Integrated SD card or external DAQ system |
| Communication Interface | RS232 serial port |
| Software Platform | Windows-based configuration and analysis suite |
| Brand | AeroNose |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer | AeroNose (OEM/ODM Producer) |
| Model | HT8820 |
| Detection Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) in Mid-Infrared Band |
| Target Gases | CH₄ (0–15 ppm), N₂O (0–6 ppm) |
| Precision | CH₄: ±3 ppb (at 2 ppm), N₂O: ±0.7 ppb (at 330 ppb) |
| Response Time | <15 s |
| Operating Temperature | −10 °C to +45 °C |
| Storage Temperature | −25 °C to +50 °C |
| Humidity | <95% RH (non-condensing) |
| Pressure Range | 70–110 kPa |
| Dimensions | 50 cm × 36 cm × 18 cm |
| Weight | <15 kg |
| Power Supply | 12 VDC / 10 A |
| Power Consumption | <70 W (steady-state) |
| Data Storage | Integrated SD card or external DAQ system |
| Interface | RS232 serial port |
| Software | Windows-based configuration & acquisition suite |
| Brand | AeroNose |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer | AeroNose (OEM/ODM Capable) |
| Model | HT8830 |
| Technology Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) in Mid-Infrared Region |
| Detection Gases & Ranges | CO₂: 0–5000 ppm |
| N₂O | 0–6 ppm |
| H₂O | 0–30000 ppm |
| Accuracy | CO₂: ±0.5 ppm @ 400 ppm |
| N₂O | ±0.5 ppb @ 330 ppb |
| H₂O | ±10 ppm @ 10000 ppm |
| Response Time | <15 s |
| Operating Temperature | −10 °C to +45 °C |
| Storage Temperature | −25 °C to +50 °C |
| Relative Humidity | <95% RH (non-condensing) |
| Atmospheric Pressure Range | 70–110 kPa |
| Dimensions | 50 cm × 36 cm × 18 cm |
| Weight | <15 kg |
| Power Supply | 12 VDC / 10 A |
| Power Consumption | <70 W (steady-state) |
| Data Storage | Integrated SD card or external DAQ system |
| Communication Interface | RS232 serial port |
| User Interface | Windows-based control and visualization software |
| Brand | AeroNose |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer | AeroNose (OEM/ODM Producer) |
| Model | HT8840 |
| Measurement Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Detected Gases & Ranges | CO₂: 0–5000 ppm |
| CH₄ | 0–15 ppm |
| H₂O | 0–30000 ppm |
| Accuracy | CO₂: ±0.5 ppm (at 400 ppm) |
| CH₄ | ±0.5 ppb (at 2 ppm) |
| H₂O | ±10 ppm (at 10000 ppm) |
| Response Time | ≤30 s |
| Operating Temperature | −10 °C to +45 °C |
| Storage Temperature | −25 °C to +50 °C |
| Relative Humidity | <95% RH, non-condensing |
| Atmospheric Pressure Range | 70–110 kPa |
| Dimensions | 50 cm × 36 cm × 18 cm |
| Weight | <15 kg |
| Power Supply | 12 VDC / 10 A |
| Power Consumption | <70 W (steady-state) |
| Data Storage | Integrated SD card or external DAQ system |
| Communication Interface | RS232 serial port |
| User Interface | Windows-based control software |
| Brand | AeroNose |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | HT8850 |
| Price | USD 140,000 (approx.) |
| Measurement Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) in Mid-Infrared Region |
| Target Gases | CO₂, CH₄, N₂O, H₂O |
| Detection Limits | CO₂: ±0.5 ppm (at 400 ppm) |
| CH₄ | ±3 ppb (at 2 ppm) |
| N₂O | ±0.5 ppb (at 330 ppb) |
| H₂O | ±10 ppm (at 10,000 ppm) |
| Measurement Ranges | CO₂: 0–5000 ppm |
| CH₄ | 0–15 ppm |
| N₂O | 0–6 ppm |
| H₂O | 0–30,000 ppm |
| Response Time | <30 s (t₉₀) |
| Operating Temperature | −10 °C to +45 °C |
| Storage Temperature | −25 °C to +50 °C |
| Relative Humidity | <95% RH (non-condensing) |
| Atmospheric Pressure Range | 70–110 kPa |
| Dimensions | 50 cm × 36 cm × 18 cm |
| Weight | <15 kg |
| Power Supply | 12 VDC / 10 A |
| Power Consumption | <70 W (steady-state) |
| Data Storage | Integrated SD card or external DAQ system |
| Communication Interface | RS-232 serial port |
| User Interface | Windows-based configuration and visualization software |
| Brand | Aeroqual |
|---|---|
| Origin | New Zealand |
| Instrument Type | Portable |
| Measurement Range (Low) | 0–0.5 ppm |
| Detection Limit (Low) | 1 ppb |
| Response Time (Low) | < 95 s |
| Measurement Range (High) | 0–10.00 ppm |
| Resolution (High) | 0.01 ppm |
| Response Time (High) | < 35 s |
| Leakage Probe Range | 0–50.00 ppm (up to 100 ppm) |
| Resolution (Leak) | 0.01 ppm |
| Response Time (Leak) | < 10 s |
| Sensor Technology | GSS (Gas Sensitive Semiconductor) with Built-in Compensation Algorithm |
| Operating Environment | –5 to 50 °C, 5–95% RH (non-condensing) |
| Sampling Method | Active pump-assisted aspiration |
| Optional Multi-gas Modules | VOC, CO, NH₃ |
| Brand | AeroQual |
|---|---|
| Model | AQM 60 |
| Measurement Principle | Electrochemical & Metal Oxide Semiconductor (MOS) Sensor Array |
| Gas Parameters | O₃, NO₂, CO, SO₂, CO₂, VOCs |
| Particulate Monitoring | PM₁₀ (optional PM₂.₅) |
| Meteorological Parameters | Temperature, Relative Humidity, Wind Speed, Wind Direction, Noise |
| Data Logging Interval | Configurable down to 2-minute sampling |
| Communication Interfaces | GSM/GPRS/UMTS modem, Ethernet (LAN/WLAN), RS232 |
| Calibration Traceability | NIST-traceable gas standards |
| Enclosure Rating | IP65-rated weatherproof housing |
| Onboard Storage | Internal flash memory (≥16 GB) |
| Power Supply | 12–24 V DC or solar-compatible |
| Brand | Aeroqual |
|---|---|
| Origin | New Zealand |
| Model | AQM65 |
| Particle Detection | PM1, PM2.5, PM10, TSP (via turbidimetric & optical counting methods) |
| Gaseous Pollutants | O₃, NO₂, CO, SO₂, NOₓ, H₂S, CO₂, VOC (ppb–ppm range), CH₄ |
| Measurement Accuracy | ±(1–5 µg/m³ or 1–3% of reading, depending on parameter) |
| Detection Limits | 0.1–10 ppb (gases), 1 µg/m³ (PM) |
| Data Logging | 32 GB internal storage (>5 years at 1-min intervals) |
| Communication | Wi-Fi, Ethernet (LAN), optional 3G/4G cellular |
| Environmental Rating | IP65 |
| Operating Temperature | −35 °C to +50 °C |
| Power Supply | 90–264 VAC, 47–63 Hz (AQM65) |
| Dimensions | 1310 × 510 × 280 mm (AQM65), 483 × 330 × 187 mm (AQS1) |
| Weight | <30 kg (AQM65), <13 kg (AQS1) |
| Brand | Aeroqual |
|---|---|
| Origin | New Zealand |
| Model | AQS 1 |
| Particle Detection | PM₁, PM₂.₅, PM₁₀, TSP (via turbidimetric & optical counting) |
| Gaseous Pollutants | O₃, NO₂, CO, SO₂, NOₓ, H₂S, CO₂, VOC (ppb–ppm range), CH₄ |
| Detection Principle | Nephelometric turbidity (670 nm laser with sheath air), electrochemical (gases), and metal oxide semiconductor (VOC/CH₄) |
| Data Logging | Up to 32 GB internal storage (>5 years at 1-min intervals) |
| Environmental Rating | IP65 |
| Operating Temperature | −35 °C to +50 °C |
| Power Supply | 100–260 VAC (31.3 W typical) or 12 VDC (34.3 W, optional) |
| Dimensions | 483 × 330 × 187 mm (H×W×D) |
| Weight | <13 kg |
| Brand | Aeroqual |
|---|---|
| Origin | New Zealand |
| Model | DusT Sentry |
| Particle Measurement Principle | Optical Particle Counting (OPC) via Right-Angle Laser Scattering |
| Measured Parameters | TSP, PM₁₀, PM₂.₅, PM₁ |
| Optional Integrated Gases | VOCs, NO₂, O₃ |
| Sampling Flow Rate | 1.0 LPM |
| Detection Limit | <1 µg/m³ |
| Accuracy | ±(5 µg/m³ + 15% of reading) |
| Resolution | 0.1 µg/m³ |
| Data Logging Interval | 1 min to 24 h |
| Operating Temperature | −10 °C to +45 °C |
| Power Supply | 100–260 VAC (24.7 W) or 12 VDC (27.2 W) |
| Enclosure | IP65-rated GRP cabinet with aluminum solar radiation shield |
| Weight | <13 kg |
| Dimensions | 483 H × 330 W × 187 D mm (incl. shield & mounting hardware) |
| Data Storage | 32 GB SSD (≥5 years at 1-min intervals) |
| Certified | MCERTS-approved for precision and repeatability |
| Comms | Wi-Fi, Ethernet, optional HSPA 3G cellular modem |
| Software | Aeroqual Connect (browser-based local configuration), Aeroqual Cloud (secure encrypted remote data access, diagnostics, calibration logging, alarm management) |
| Brand | Aeroqual |
|---|---|
| Origin | New Zealand |
| Model | S300/S500 |
| Measurement Units | ppm, mg/m³, % RH, °C/°F |
| Display Functions | Current, Min/Max/Avg Values |
| Sampling | Active fan-assisted, interchangeable sensor heads |
| Calibration | Zero and span calibration supported |
| Temperature Range | −40 °C to 124 °C |
| Humidity Range | 0–100% RH (non-condensing) |
| Operating Temp. | 0–40 °C |
| Storage | −5 °C to 45 °C, 0–95% RH |
| Enclosure | PC/ABS, IP20 / NEMA 1 |
| Dimensions (w/sensor head) | 195 × 122 × 54 mm |
| Weight | <460 g (<16 oz) with battery & sensor |
| Power | Rechargeable 12 VDC Li-ion (2700 mAh) |
| Analog Output | 0–5 V |
| Digital Interface | RS-232 to USB |
| Data Logging Capacity | Up to 8,188 records |
| Clock | Real-time timestamping |
| Compliance | FCC Part 15 |
| EN 50082-1 | 1997 |
| EN 50081-1 | 1992 |
| Optional Accessories | Industrial protective housing, wall mount, IP41 remote sensor kit, carry case, humidity/temperature probe |
| Brand | Aeroqual |
|---|---|
| Origin | New Zealand |
| Model | Series 500 |
| Instrument Type | Portable |
| Detectable Gases | CO, CO₂, NO, H₂S, O₃ |
| Response Time | ≤120 s (T90, gas-dependent) |
| Measurement Accuracy | ±0.5–10% of reading + offset (gas- and sensor-specific) |
| Measurement Range | 0.001–10,000 ppm (gas-dependent) |
| Data Logging Capacity | 8,188 records (including 2,706 temperature/humidity entries) |
| Power | Rechargeable 12 V DC Li-ion battery (2.7 Ah), ~8 h operation |
| Dimensions (with sensor head) | 195 × 122 × 54 mm |
| Weight (with battery & sensor head) | <460 g |
| IP Rating | IP20 / NEMA 1 |
| Operating Environment | 5–45 °C, 0–95% RH (non-condensing) |
| Compliance | FCC Part 15, EN 50082-1:1997, EN 50081-1:1992 |
| Brand | Aeroqual |
|---|---|
| Origin | New Zealand |
| Model | AEROQUAL Series 500 |
| Sensor Compatibility | Interchangeable modular sensor heads (sold separately) |
| Power | Rechargeable 12 V DC Li-ion battery (2700 mAh, ~8 h runtime) |
| Data Logging | 8,188 total readings (including up to 2,706 temperature/humidity records) |
| Communication | USB (RS-232 via adapter), 0–5 V analog output |
| Environmental Rating | IP20 / NEMA 1 |
| Dimensions | 195 × 122 × 54 mm (with sensor head) |
| Weight | <460 g (<16 oz) |
| Operating Range | 5–45 °C, 0–95 %RH (non-condensing) |
| Certifications | FCC Part 15, EN 50082-1:1997, EN 50081-1:1992 |
| Origin | Netherlands |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | AET Extension Tube |
| Pricing | Upon Request |
| Brand | AFRISO |
|---|---|
| Origin | Germany |
| Model | BL100 |
| Instrument Type | Portable Flue Gas Analyzer |
| Measured Gases | O₂, CO |
| O₂ Range | 0–21.0 vol.% |
| CO Range | 0–20,000 ppm |
| O₂ Accuracy | ±0.2 vol.% of reading |
| CO Accuracy | ±5 ppm (≤100 ppm), ±5% of reading (100–2000 ppm) |
| Repeatability | ±2% |
| Response Time (T90) | <3 s (temperature), <30 s (CO), <20 s (O₂) |
| Stability | ±2% over 8 h |
| Display | 2.8" TFT color screen |
| Data Storage | 4 GB micro-SD/HC card |
| Battery | Li-ion, 3.6 V / 1800 mAh, up to 10 h operation |
| Dimensions (H×W×D) | 215 × 70 × 40 mm |
| Weight | ~500 g (incl. magnetic protective case) |
| IP Rating | IP42 (EN 60529) |
| Operating Temperature | −5 to +40 °C |
| Storage Temperature | −20 to +50 °C |
| Brand | AFRISO |
|---|---|
| Model | E30X |
| Type | Portable Flue Gas Analyzer |
| Sensor Technology | Electrochemical (O₂, CO, NO, NO₂, SO₂, H₂S, etc.) |
| Display | 4.3" TFT Color Screen with Chinese/English UI |
| Data Storage | MicroSD card (up to 16 GB) |
| Battery Life | Up to 12 h (Li-ion, rechargeable during operation) |
| Auto-Calibration | Built-in zero and span check |
| Response Time | <20 s (T90) |
| Accuracy | CO measurement ±2 ppm (low-range), NOₗₒw ≤2 ppm error |
| Compliance | EN 50379-1/-2, DIN EN 15545, CE marked |
| Connectivity | Bluetooth 4.2, USB-C, QR code export |
| Operating Temperature | 0–40 °C |
| Dimensions | 230 × 120 × 65 mm |
| Weight | 1.2 kg |
| Magnetic Mount | Integrated rear magnet for hands-free mounting |
| Brand | AFRISO |
|---|---|
| Origin | Germany (Manufactured under German engineering standards, assembled/quality-controlled in Beijing) |
| Manufacturer Type | OEM/ODM Producer |
| Model | M60X |
| Compliance | EN 50379-1/-2, TÜV-certified |
| Sensor Lifespan | ≥5 years (O₂, CO/H₂, SO₂low, NO, NO₂, NOₓ) |
| Response time (T90) | O₂ <20 s |
| O₂ range | 0–21 vol.% (±0.2 vol.%) |
| CO (H₂-compensated) | 0–20,000 ppm (±5 ppm up to 50 ppm, ±5% of reading above) |
| COhigh | 0–4.0 vol.% (40,000 ppm) |
| SO₂ | 0–5,000 ppm |
| NO | 0–5,000 ppm |
| NO₂ | 0–500 ppm |
| NOₓ (calculated) | 0–5,500 ppm |
| CO₂ (NDIR) | 0–max theoretical (fuel-dependent) |
| Flue gas temperature | 0–1000 °C (±1 °C up to 300 °C, ±1% above) |
| Ambient temperature | −20–+200 °C |
| Differential pressure | ±150 hPa |
| Flow velocity | 0.5–70 m/s |
| Display | 3.5″ TFT color (240 × 320 px) |
| Data logging | Internal + optional microSD/SDHC (up to 32 GB) |
| Battery | Li-ion 3.6 V / 2900 mAh (≥12 h operation, chargeable during measurement) |
| Dimensions | 220 × 90 × 53 mm (incl. magnetic protective sleeve) |
| Weight | ~685 g |
| Enclosure | IP42 (EN 60529) |
| Interface | IR, Bluetooth 4.2, USB Mini-B |
| Accessories | 290 mm 600 °C probe, 2.4 m heated sampling hose, dual-stage KFP condensate filter with integrated thermocouple, ambient temp probe, magnetic sleeve, carry case, charger/USB cable, EN 50379 certificate, factory calibration certificate, user manual |
| Brand | AFRISO |
|---|---|
| Origin | Germany |
| Instrument Type | Portable Flue Gas Analyzer |
| Model | M60X20 |
| Accuracy (SO₂/NO/NO₂) | ±10 ppm (0–200 ppm), ±5% of reading (>200 ppm) |
| Accuracy (CO) | ±5 ppm (0–50 ppm), ±5% of reading (>50 ppm) |
| Repeatability | ±2% |
| Response Time (T90) | ≤45 s (SO₂), ≤30 s (NO, CO), ≤60 s (NO₂, COhigh) |
| Stability | ±0.1% of full scale over 8 hours |
| Measured Gases | O₂, CO (H₂-compensated), COhigh, NO, SO₂, NO₂, CO₂ (IR), calculated λ, CO₂, η-efficiency, flue gas loss, dew point, ΔT |
| IP Rating | IP42 |
| Operating Temperature | 5–40 °C |
| Weight | 685 g (with magnetic protective case) |
| Brand | AFRISO |
|---|---|
| Origin | Germany (manufactured under AFRISO engineering specifications |
| Model | STM225 |
| Instrument Type | Portable Laser-Based Dust Monitor |
| Measurement Principle | Dual-Beam Laser Light Scattering |
| Dust Range | 0–300 mg/m³ |
| Resolution | 0.1 mg/m³ |
| Accuracy (Indicated Error) | ±0.5% FS |
| Repeatability | ±0.2% FS |
| Response Time (T90) | ≤0.1 s |
| Drift (1-h Stability) | <±0.5% FS over 1 h |
| Operating Temperature | –5 to +40 °C |
| Storage Temperature | –20 to +50 °C |
| Display | 5.7" color TFT touchscreen |
| Power Supply | AC 230 V, 50 Hz |
| Communication | Bluetooth 4.2, USB 2.0 |
| Enclosure Rating | IP40 |
| Dimensions (W×H×D) | 190 × 275 × 330 mm |
| Weight | 7.5 kg |
| Compliance | Designed to support ISO 16940, EN 13284-1, and ASTM D6216 measurement protocols for particulate matter in industrial flue gases |
| Brand | AFRISO |
|---|---|
| Model | STM225 |
| Type | Portable dust monitor |
| Measurement principle | Dual-beam laser scattering |
| Dust concentration range | 0–300 mg/m³ |
| Resolution | 0.1 mg/m³ |
| Accuracy (indicated error) | ±0.50 mg/m³ |
| Repeatability | ±0.2 mg/m³ |
| Response time | 0.10 s |
| Stability | ±1% over 1 h |
| Operating temperature | −5 to 40 °C |
| Storage temperature | −20 to +50 °C |
| Dimensions (W×H×D) | 190 × 275 × 330 mm |
| Weight | ~7.5 kg |
| Ingress protection | IP40 |
| Display | 5.7" color touchscreen |
| Power supply | AC 230 V, 50 Hz |
| Communication interfaces | Bluetooth, USB |